کانون پلاس +Canon iR105
E000-0000 The temperature of the fixing assembly is abnormally high copyir.com
When the main power switch is turned on, the reading of the main thermistor does not reach 70 deg C within 3 min 30 sec copyir.com – Check if the main thermistor is mounted properly and also check if there is no contamination copyir.com – Replace the main thermistor copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E000-0010 The temperature of the fixing assembly is abnormally high copyir.com
The power is turned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E001-0001 The over-rising in temperature of the fixing assembly is detected copyir.com
The hardware port detects a fault copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E001-0002 The over-rising in temperature of the fixing assembly is detected copyir.com
Either the main thermistor or the sub thermistor detects 230 deg C or higher for 2 sec copyir.com – Check if the main thermistor and the sub thermistor are mounted properly copyir.com – Replace the main thermistor or the sub thermistor copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E001-0003 The over-rising in temperature of the fixing assembly is detected copyir.com
The reading of the main thermistor is higher than that of the sub thermistor by 50 deg C or more for 1 sec copyir.com Check if the main thermistor and the sub thermistor are mounted properly copyir.com – Replace the main thermistor copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E001-0004 The over-rising in temperature of the fixing assembly is detected copyir.com
The reading of the main thermistor is lower than that of the sub thermistor by 50 deg C or more for 1 sec copyir.com – Check if the main thermistor is mounted properly copyir.com – Replace the main thermistor copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E001-0010 The over-rising in temperature of the fixing assembly is detected copyir.com
The power is turned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E002-0000 The rise in temperature of the fixing assembly is faulty copyir.com
The reading of the main thermistor (TH1فتوکپی کانون does not reach 100 deg C 2 min 30 sec after it has exceeded 70 deg C copyir.com – Check if the connector (J505فتوکپی کانون of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly copyir.com – Check the wiring between the thermistor and the DC controller copyir.com -Check if the main thermistor is mounted properly and also check if there is no contamination copyir.com – Replace the main thermistor copyir.com – Replace the fixing heater copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E002-0001 The rise in temperature of the fixing assembly is faulty copyir.com
The reading of the main thermistor does not reach 150 deg C within 2 min 30 sec after it has exceeded 100 deg C copyir.com – Check if the connector (J505فتوکپی کانون of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly copyir.com – Check the wiring between the thermistor and the DC controller copyir.com -Check if the main thermistor is mounted properly and also check if there is no contamination copyir.com – Replace the main thermistor copyir.com – Replace the fixing heater copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E002-0010 The rise in temperature of the fixing assembly is faulty copyir.com
The power has been turned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E003-0000 The fixing temperature is too low after a standby state copyir.com
The reading of the main thermistor is 70 deg C or lower for 2 sec or more after it has reached 100 deg C copyir.com – Check if the connector (J505فتوکپی کانون of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly copyir.com – Check the wiring between the thermistor and the DC controller copyir.com -Check if the main thermistor is mounted properly and also check if there is no contamination copyir.com – Replace the main thermistor copyir.com – Replace the fixing heater copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E003-0010 The fixing temperature is too low after a standby state copyir.com
The power has been turned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E004-0000 The fixing assembly is faulty copyir.com
The SSR used to drive the fixing heater has a short circuit (detection by hardware circuitryفتوکپی کانون copyir.com – Replace the AC driver PCB copyir.com – Replace the DC controller PCB copyir.com Caution You will have to clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E005-0000 The absence of the fixing web is detected copyir.com
The length of the fixing web that has been taken up is more than a specific value and the fixing web length sensor (PS7فتوکپی کانون has detected the absence of the web for 5 sec or more copyir.com – Check the position of the fixing web detection lever copyir.com – Replace the fixing web copyir.com – Replace the fixing web length sensor copyir.com – Replace the DC controller PCB copyir.com Caution After replacing the fixing web, you will have to clear the two web counters in service mode (COPIER>COUNTER>MISC>FIX-WEB and COPIER>COUNTER>DRBL-1>FIX-WEBفتوکپی کانون copyir.com
E005-0010 The absence of the fixing web is detected copyir.com
The power is turned off and then on without clearing the error copyir.com – Reset the counters of the two webs to zero in service mode (COPIER>COUNTER>MISC>FIX-WEB, COPIER>COUNTER>DRBL-1>FIX-WEBفتوکپی کانون
E010-0000 The rotation of the main motor is faulty copyir.com
No clock pulse arrive for 2 sec or more after the main motor drive signal (MMFGفتوکپی کانون has been generated copyir.com – Check if the connecter (J611, J612فتوکپی کانون of the main motor is mounted properly copyir.com – Check if the connector (J1720فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the main motor copyir.com – Replace the relay PCB copyir.com – Replace the DC controller PCB copyir.com
E012-0000 The rotation of the drum motor is faulty copyir.com
No clock pulse arrives for 2 sec or more after the drum motor drive signal (DMFGفتوکپی کانون has been generated copyir.com – Check if the connector (J1720فتوکپی کانون of the relay PCB is mounted properly copyir.com – Check if the connector (J512فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Check if the connecter (J601, J602فتوکپی کانون of the drum motor is mounted properly copyir.com – Replace the drum motor copyir.com – Replace the DC controller PCB copyir.com
E013-0000 The lock of the waste toner feed screw is detected copyir.com
The waste toner feed screw fails to rotate normally, and the switch MSW2 is pressed multiple times within a specific period of time copyir.com – Re-mount the waste toner pipe copyir.com – Replace the waste toner pipe copyir.com – Replace the waste toner clog detecting switch copyir.com – Replace the DC controller PCB copyir.com Caution You will have to clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E013-0010 The lock of the waste toner feed screw is detected copyir.com
The power is tuned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E014-0000 The rotation of the fixing motor is faulty copyir.com
The motor clock signal is not detected for 2 sec or more after the fixing motor drive signal has been generated copyir.com – Check if the connecter (J651, J652فتوکپی کانون of the fixing motor is mounted properly copyir.com – Replace the fixing motor copyir.com – Replace the relay PCB copyir.com – Replace the DC controller PCB copyir.com
E015-0000 The rotation of the pickup motor is faulty copyir.com
The motor lock signal is not detected for 2 sec or more after the pickup motor drive signal has been generated copyir.com – Check if the connecter (J621, J622فتوکپی کانون of the pickup motor is mounted properly copyir.com – Replace the pickup motor copyir.com – Replace the relay PCB copyir.com – Replace the DC controller PCB copyir.com
E019-0000 The waste toner case is full, or the waste toner case full sensor is faulty copyir.com
More than a specific number of pages are printed without disposing of the waste toner after the waste toner case has been found to be full copyir.com – Dispose the waste toner in the case copyir.com – Check the operation of the base plate of waste toner case copyir.com – Check if the connector (J514فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the waste toner full sensor copyir.com – Replace the DC controller PCB copyir.com
E020-0000 The difficulty providing toner inside the hopper developing assemblies is detected copyir.com
Although the developing assembly is supplied with toner, the absence of toner inside it is detected for 3 sec or more copyir.com – Replace the magnet roller drive clutch copyir.com – Replace the toner feed motor (M18فتوکپی کانون copyir.com – Replace the toner sensor copyir.com Caution You will have to clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E020-0010 The difficulty providing toner inside the hopper developing assemblies is detected copyir.com
The power is turned off and then on without clearing the error copyir.com – Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERRفتوکپی کانون copyir.com
E025-0000 The toner feed motor inside the hopper is faulty copyir.com
The DC controller PCB detects an overcurrent flowing to the toner feed motor (M6فتوکپی کانون inside the cartridge for 10 sec or more twice copyir.com (In response to the first detection, it indicates the message “Shake the Toner Case, and Set copyir.com”فتوکپی کانون – Check if the connector (J512فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the toner feed motor (M6فتوکپی کانون copyir.com
E032-0000 The counter of the copy data controller or the NE controller is faulty copyir.com
The copy data controller or the NE controller are disconnected after they have once been connected copyir.com – Check if the connecter of the main controller PCB is mounted properly copyir.com – Replace the main controller PCB copyir.com – Replace the copy data controller or the NE controller copyir.com
E043-0000 The rotation of the side paper deck main motor is faulty copyir.com
The PLL lock signal (DMPLKفتوکپی کانون does not arrive for 2 sec or more after the side paper deck main motor drive signal has been generated copyir.com – Check if the connecter (J101, J106فتوکپی کانون of the side deck driver PCB is mounted properly copyir.com – Replace the side deck main motor copyir.com – Replace the side deck driver PCB copyir.com – Replace the DC controller PCB copyir.com
E051-0001 There is an error in the detection of the horizontal registration home position copyir.com
Departure from home position is not detected within 5 sec during a horizontal registration home position search copyir.com – Replace the horizontal registration sensor copyir.com – Replace the horizontal registration motor copyir.com – Check if the manual feed tray open/closed detecting switch is mounted properly copyir.com – Replace the stackless feed driver PCB copyir.com – Replace the DC controller PCB copyir.com
E051-0002 There is an error in the detection of the horizontal registration home position copyir.com
Home position is not detected within 5 sec during a horizontal registration home position search copyir.com – Replace the horizontal registration sensor copyir.com – Replace the horizontal registration motor copyir.com – Check if the manual feed tray open/closed detecting switch is mounted properly copyir.com – Replace the stackless feed driver PCB copyir.com – Replace the DC controller PCB copyir.com
E051-0003 There is an error in the detection of the horizontal registration home position copyir.com
The horizontal registration detection movement for the preceding sheet does not end within 5 sec at the start of a horizontal registration search during printing copyir.com – Replace the horizontal registration sensor copyir.com – Replace the horizontal registration motor copyir.com – Check if the manual feed tray open/closed detecting switch is mounted properly copyir.com – Replace the stackless feed driver PCB copyir.com – Replace the DC controller PCB copyir.com?
E065-0000 There is an error in the high-voltage output to the transfer charging assembly copyir.com
An error (leakageفتوکپی کانون is detected in the high-voltage output to the primary charging assembly copyir.com – Check if the primary charging assembly is mounted properly and also check if there is no contamination copyir.com – Check if the connector (T601, J723, J730فتوکپی کانون of the HV-DC PCB is mounted properly and also check the wiring copyir.com – Replace the HV-DC PCB copyir.com
E067-0000 There is an error in the high-voltage output copyir.com
An error is detected in two or more of the following at the same time: the primary high voltage, pre-transfer high voltage, transfer high voltage, and separation high voltage copyir.com Or, an error (leakageفتوکپی کانون in the high-voltage output to the separation charging assembly is detected copyir.com – Check if the primary charging assembly, pretransfer charging assembly, transfer charging assembly and separation charging assembly are mounted properly copyir.com – Check if the connector (J722, J723, J730فتوکپی کانون of the HV-DC PCB is mounted properly and also check the wiring copyir.com – Replace the HV-DC PCB copyir.com – Replace the HV-AC PCB copyir.com
E068-0000 There is an error in the high-voltage output to the separation charging assembly copyir.com
An error (leakageفتوکپی کانون to the high-voltage output to the separation charging assembly is detected copyir.com – Check if the transfer charging assembly and separation charging assembly are mounted properly copyir.com – Check if the connector (J722, J723, J730, J734فتوکپی کانون of the HV-DC PCB and the connector (J741, J742فتوکپی کانون of the HV-AC PCB are mounted properly copyir.com – Replace the HV-AC PCB copyir.com – Replace the separation charging assembly copyir.com – Replace the pre-transfer charging assembly copyir.com
E069-0000 There is an error in the high-voltage output to the transfer charging assembly copyir.com
An error (leakageفتوکپی کانون is detected in the high-voltage output to the transfer charging assembly copyir.com – Check if the transfer charging assembly and separation charging assembly are mounted properly copyir.com – Check if the connector (T701, J723, J730فتوکپی کانون of the HV-DC PCB is mounted properly and also check the wiring copyir.com – Replace the HV-DC PCB copyir.com – Replace the pre-transfer charging assembly copyir.com
E100-0000 The BD PCB is faulty copyir.com
The BD signal does not arrive within 1 sec after the laser drive signal has been generated copyir.com Or, the BD signal does not arrive for 1 sec or more while the laser remains ON copyir.com – Check if the BD PCB, laser driver PCB and DC controller are connected properly copyir.com – Replace the BD PCB copyir.com – Replace the laser scanner unit copyir.com – Replace the DC controller PCB copyir.com
E110-0000 The rotation of the laser scanner motor is faulty copyir.com
The constant speed rotation signal (LM-RDYفتوکپی کانون does not arrive for 20 sec or more after the laser scanner motor (M4فتوکپی کانون drive signal has been generated copyir.com – Check if the connector (J762فتوکپی کانون of the laser scanner motor driver PCB is mounted properly copyir.com – Check if the connector (J503فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the laser scanner unit copyir.com – Replace the DC controller PCB copyir.com
E111-0000 The rotation of the laser motor cooling fan is faulty copyir.com
The lock signal arrives for 5 sec or more although the laser motor cooling fan (FM1فتوکپی کانون is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the laser motor cooling fan copyir.com – Check if the connector (J503فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the laser motor cooling fan copyir.com – Replace the DC controller PCB copyir.com
E121-0001 The rotation of the laser cooling fan (1/2فتوکپی کانون is faulty copyir.com
The lock signal arrives for 5 sec or more although the laser cooling fan 1 (FM3فتوکپی کانون is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the laser cooling fan 1 copyir.com – Check if the connector (J503فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the laser cooling fan 1 copyir.com – Replace the DC controller PCB copyir.com
E121-0002 The rotation of the laser cooling fan (1/2فتوکپی کانون is faulty copyir.com
The lock signal arrives for 5 sec or more although the laser cooling fan 2 (FM5فتوکپی کانون is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the laser cooling fan 2 copyir.com – Check if the connector (J503فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the laser cooling fan 2 copyir.com – Replace the DC controller PCB copyir.com
E202-0000 There is an error in the detection of the scanner home position copyir.com
Scanner home position cannot be detected within a specific period of time after the power switch is turned on or the Start key is pressed copyir.com Caution No code will be indicated copyir.com The keys will be locked copyir.com You can check the code in service mode (COPIER>DISPLAY>ERRفتوکپی کانون copyir.com – Check if the scanner motor is connected properly, and replace the scanner motor if necessary copyir.com – Check if the connector (J1720فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the scanner home position sensor copyir.com – Replace the reader controller PCB copyir.com
E204-0000 There is an error in the detection of the image leading edge signal copyir.com
During forward movement in fixed reading mode or during a home position search, the image leading signal does not occur; or, in stream reading mode, the image leading edge signal does not arrive from the ADF controller PCB copyir.com Caution No code will be indicated copyir.com The keys will be locked copyir.com You can check the code in service mode (COPIER>DISPLAY>ERRفتوکپی کانون copyir.com – Check if the scanner motor is connected properly, and replace the scanner motor if necessary copyir.com – Replace the scanner image leading edge sensor copyir.com – Replace the reader controller PCB copyir.com
E211-0000 The rise in temperature of the scanning lamp heater is faulty copyir.com
While the power is ON, the ambient temperature of the scanning lamp does not exceed 10 deg C 2 min after the florescent heater has gone ON; or, after the power is turned on, the reading of the ambient temperature of the scanning lamp is 0 deg C or lower copyir.com – Check if the connecter (J852, J853فتوکپی کانون of the light control PCB is mounted properly copyir.com – Replace the scanning lamp heater copyir.com – Replace the light control PCB copyir.com – Replace the reader controller PCB copyir.com
E215-0000 The rise in temperature of the scanning lamp heater is faulty copyir.com
While the scanning lamp is OFF, the reading of the ambient temperature is 170 deg C or higher copyir.com – Check if the connecter (J852, J853فتوکپی کانون of the light control PCB is mounted properly copyir.com – Replace the scanning lamp heater copyir.com – Replace the light control PCB copyir.com – Replace the reader controller PCB copyir.com
E218-0000 The scanning lamp is not mounted properly copyir.com
When the power is turned on, the absence of the scanning lamp is detected copyir.com – Check if the scannning lamp is mounted properly copyir.com – Check if the connecter (J1002, J1003فتوکپی کانون of the inverter PCB is mounted properly copyir.com – Check if the connector (J1720فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the scanning lamp copyir.com – Replace the reader controller PCB copyir.com
E219-0000 The scanning lamp life
While the scanning lamp is ON, the reading of the ambient temperature is 170 deg C or higher copyir.com – Check if the connecter (J852, J853فتوکپی کانون of the light control PCB is mounted properly copyir.com – Replace the scanning lamp heater copyir.com – Replace the light control PCB copyir.com – Replace the reader controller PCB copyir.com
E220-0000 The lighting of the scanning lamp is faulty copyir.com
The scanning lamp does not reach a specific intensity within 10 sec after it is tuned on (if the room temperature is 10 deg C or lower, within 60 secفتوکپی کانون copyir.com Or, the ON detection signal (FL-DTCTفتوکپی کانون does not go OFF within 5 sec after the scanning lamp is turned off; during shading adjustment, the ON detection signal (FL-DTCTفتوکپی کانون does not go ON within 60 sec after the scanning lamp is turned on copyir.com – Check if the connecter (J852, J853فتوکپی کانون of the light control PCB is mounted properly copyir.com – Replace the scanning lamp heater copyir.com – Replace the light control PCB copyir.com – Replace the reader controller PCB copyir.com
E222-0000 The rise in temperature of the scanning lamp heater is faulty copyir.com
During the initial activation after power-on, the reading does not reach 70 deg C within 5 min after the heater is turned on copyir.com Or, during standby or reading operation, the reading does not reach 75 deg C within 3 min after the heater is tuned on copyir.com – Check if the connecter (J852, J853فتوکپی کانون of the light control PCB is mounted properly copyir.com – Replace the scanning lamp heater copyir.com – Replace the light control PCB copyir.com – Replace the reader controller PCB copyir.com
E240-0000 The communication between the MCON and DCON is faulty copyir.com
A communication fault exists between the CPUs of the main controller PCB and the DC controller PCB copyir.com – Check the wiring between the DC controller PCB and the main controller PCB copyir.com – Replace the DC controller PCB copyir.com – Replace the main controller PCB copyir.com
E241-0000 The communication between the original orientation detection PCB and RCON is faulty copyir.com
The initial communication between the CPUs of the original orientation detection PCB and the reader controller PCB fails copyir.com – Replace the original orientation PCB copyir.com – Replace the reader controller PCB copyir.com
E241-0001 The communication between the original orientation detection PCB and RCON is faulty copyir.com
When the orientation of an original is detected, the result of detection is not communicated by the original orientation detection PCB until the next original is read copyir.com – Replace the original orientation PCB copyir.com – Replace the reader controller PCB copyir.com
E241-0002 The communication between the original orientation detection PCB and RCON is faulty copyir.com
The result of detection of the last original is not communicated 5 sec after the end of reading the last original copyir.com – Replace the original orientation PCB copyir.com – Replace the reader controller PCB copyir.com
E243-0000 The communication between the control panel PCB and MCON is faulty copyir.com
A communication fault exists between the CPUs of the control panel PCB and the main controller PCB copyir.com – Replace the control panel PCB copyir.com – Replace the main controller PCB copyir.com
E251-0000 The rotation of the inverter cooling fan is faulty copyir.com
The lock signal (FM9LCKفتوکپی کانون arrives for 5 sec or more although the inverter cooling fan (FM9فتوکپی کانون is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the inverter cooling fan copyir.com – Check if the connecter (J1110فتوکپی کانون of the reader control PCB is mounted properly copyir.com – Replace the inverter cooling fan copyir.com – Replace the reader controller PCB copyir.com
E302-0000 Shading error
During shading operation, the reader controller PCB fails to end shading processing copyir.com – Check if the connecter (J1502, J1503فتوکپی کانون of the CCD PCB is mounted properly copyir.com – Check if the connecter (J1107, J1108فتوکپی کانون of the reader control PCB is mounted properly copyir.com – Replace the CCD PCB copyir.com – Replace the reader controller PCB copyir.com
E315-0000 There is an error in image data copyir.com The reader controller PCB is faulty copyir.com The main controller PCB is faulty copyir.com
During image rotation, the encoding/ decoding has a fault copyir.com – Replace the reader controller PCB copyir.com – Replace the main controller PCB copyir.com
E320-0000 There is a time out error in the image reading processing copyir.com
While an image is being read, the image read end notice does not arrive at the reader controller PCB within 60 sec from the CCD/AP PCB copyir.com – Check if the connecter (J1502, J1503فتوکپی کانون of the CCD PCB is mounted properly copyir.com – Check if the connecter (J1107, J1108فتوکپی کانون of the reader control PCB is mounted properly copyir.com – Replace the CCD PCB copyir.com – Replace the reader controller PCB copyir.com
E400-0000 Communication error with the ADF
While the ADF is in standby, the communication between ADF and copier is interrupted for 5 sec or more copyir.com Or, when the ADF is in operation, the communication between ADF and copier is disrupted for 0 copyir.com5 sec or more copyir.com – Check if the communication cable between the ADF and copier is connected properly copyir.com – Replace the ADF controller PCB copyir.com
E402-0000 The rotation of the ADF belt motor is faulty copyir.com
The clock signal does not occur for 100 msec when the belt motor drive signal is generated copyir.com – Check if the cable between the ADF belt motor drive PCB and ADF controller PCB is connected properly copyir.com – Replace the ADF belt motor clock sensor copyir.com – Replace the ADF belt motor copyir.com – Replace the ADF belt motor drive PCB copyir.com – Replace the ADF controller PCB copyir.com
E404-0000 The rotation of the ADF delivery motor is faulty copyir.com
The clock signal does not occur for 200 msec when the delivery motor drive signal is generated copyir.com – Replace the ADF delivery motor copyir.com – Replace the ADF delivery motor clock sensor copyir.com – Replace the ADF controller PCB copyir.com
E405-0000 The rotation of the ADF separation motor is faulty copyir.com
The clock signal does not occur for 200 msec when the separation motor drive signal is generated copyir.com – Replace the ADF separation motor copyir.com – Replace the ADF separation motor clock sensor copyir.com – Replace the ADF controller PCB copyir.com
E410-0000 The rotation of the ADF pickup motor is faulty copyir.com
The pickup roller height sensor 1 (PI8فتوکپی کانون or 2 (PI9فتوکپی کانون does not generate a signal within 2 sec after the pickup motor is driven copyir.com Or, the pickup roller home position sensor (PI7فتوکپی کانون does not generate a signal within 2 sec after the pickup motor is driven copyir.com – Replace the ADF pickup motor copyir.com – Replace the ADF pickup roller height sensor 1 copyir.com – Replace the ADF pickup roller height sensor 2 copyir.com – Replace the ADF pickup roller home position sensor copyir.com – Replace the ADF controller PCB copyir.com
E412-0000 The rotation of the ADF cooling fan is faulty copyir.com
The lock signal arrives for 100 msec or more although the cooling fan is being driven copyir.com – Replace the ADF cooling fan copyir.com – Replace the ADF controller PCB copyir.com
E420-0000 The EEPROM is faulty copyir.com The ADF controller PCB is faulty copyir.com
The backup data of the EEPROM cannot be read when the connected device is tuned on copyir.com Or, the data that has been read has a fault copyir.com – Replace the ADF controller PCB copyir.com
E602 There is an error on the hard disk copyir.com
E604-0000 The image memory is faulty or is inadequate copyir.com
The memory size does not match the model copyir.com – Increase the memory copyir.com
E609-0008 There is an error on the HDD copyir.com
At startup, the HDD fails to reach a specific temperature level within a specific period of time copyir.com – Replace the HDD copyir.com – Replace the DC controller PCB copyir.com
E609-0009 There is an error on the HDD copyir.com
At time of sleep recovery, the temperature fails to reach a specific level copyir.com – Replace the HDD copyir.com – Replace the DC controller PCB copyir.com
E610 The HDD coding key is faulty copyir.com
The SRAM/PCB is faulty copyir.com The battery has become exhausted, leading to loss of SRAM contents copyir.com – Turn off and then back on the power switch to generate the key once again copyir.com – Replace the main controller PCB copyir.com
E710-0001 There is an error in the initialization of the IPC copyir.com
The IPC (IC5فتوکپی کانون on the reader controller PCB cannot be initialized when the main power supply is turned on copyir.com – Check the cable copyir.com – Replace the reader controller PCB copyir.com
E710-0002 There is an error in the initialization of the IPC copyir.com
The IPC (IC40فتوکپی کانون on the DC controller PCB cannot be initialized when the main power supply is turned on copyir.com – Check the cable copyir.com – Replace the DC controller PCB copyir.com
E710-0003 There is an error in the initialization of the IPC copyir.com
The IPC (IC1003فتوکپی کانون on the machine controller PCB cannot be initialized when the main power is turned on copyir.com – Check the cable copyir.com – Replace the main controller PCB copyir.com
E711-0001 There is an error in the IPC communication copyir.com
Data has been written to the error register of the IPC (IC5فتوکپی کانون on the reader controller PCB 4 times or more within 1 copyir.com5 sec copyir.com – Check the cable copyir.com – Replace the reader controller PCB copyir.com
E711-0002 There is an error in the IPC communication copyir.com
Data has been written to the error register of the IPC (IC40فتوکپی کانون on the DC controller PCB 4 times or more within 2 sec copyir.com – Check the cable copyir.com – Replace the DC controller PCB copyir.com
E711-0003 There is an error in the IPC communication copyir.com
Data has been written to the error register of the IPC (IC1003فتوکپی کانون on the main controller PCB 4 times or more within 2 sec copyir.com – Check the cable copyir.com – Replace the main controller PCB copyir.com
E712-0000 Communication error with the ADF
The communication IC (IPCفتوکپی کانون on the ADF controller PCB goes out of order copyir.com – Check if the communication cable between the ADF and copier is connected properly copyir.com – Replace the ADF controller PCB copyir.com
E713-0000 There is an error in the communication with the finisher copyir.com
The communications IC (IPCفتوکپی کانون on the finisher controller PCB goes out of order copyir.com – Check if the communication cable between the finisher and copier is connected properly copyir.com – Replace the finisher controller PCB copyir.com – Replace the DC controller PCB copyir.com
E717-0001 There is an error in the communication with the NE controller copyir.com
The NE controller is not connected at power on, although it was connected before the power was turned off because of an error copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E717-0002 There is an error in the communication with the NE controller copyir.com
An IPC error has occurred while the NE controller is in operation copyir.com There is an open circuit for the IPC copyir.com An error has occurred, and the IPC communication remains disabled copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E719-0001 There is a coin vendor error copyir.com
The coin vendor is not connected when the power is turned on, although it was connected before the power was turned off because of an error copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E719-0002 There is a coin vendor error copyir.com
While the coin vendor is in operation, an IPC error has occurred, IPC has developed an open circuit, or an error preventing recovery of IPC communication has occurred copyir.com An open circuit ha been detected in the line for the pickup/delivery signal copyir.com An illegal signal has been detected copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E719-0003 There is a coin vendor error copyir.com
While the unit price is being checked at startup, an error occurs in the communication with the coin vendor copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E719-0011 There is a coin vendor error copyir.com
An error has occurred at new card reader startup copyir.com The new card reader is not connected when the power is turned off, although it was connected when the power was turned off copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E719-0012 There is a coin vendor error copyir.com
An IPC error has occurred at new card reader startup copyir.com There is an IPC open circuit copyir.com An error has occurred that prevents recovery of IPC communication copyir.com Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR copyir.com
E730-1001 There is a PDL software error copyir.com
An initialization error has occurred copyir.com – Execute PDL resetting copyir.com – Turn on the power once again copyir.com
E730-100A There is a PDL software error copyir.com
An error that may be critical to the system (e copyir.comg copyir.com, failed initializationفتوکپی کانون has occurred copyir.com – Execute PDL resetting copyir.com – Turn on the power once again copyir.com
E730-9004 There is a PDL software error copyir.com
There is an error in the communication (PAIفتوکپی کانون with an external controller copyir.com – Turn on the power once main copyir.com – Check the connection of the open I/F board and the cable copyir.com – Replace the board for the external controller open I/F copyir.com – Replace the main controller PCB copyir.com
E730-9005 There is a PDL software error copyir.com
Fault in the connector of the vide cable to the external controller – Turn on the power once main copyir.com – Check the connection of the open I/F board and the cable copyir.com – Replace the board for the external controller open I/F copyir.com – Replace the main controller PCB copyir.com
E730-A006 There is a PDL software error copyir.com
The PDL board does not respond copyir.com A subbootable is faulty or absent copyir.com – Execute PDL resetting copyir.com – Turn on the power once again copyir.com – Check the connection of the UFR board copyir.com – Re-install the firmware copyir.com – Replace the main controller PCB copyir.com
E730-A007 There is a PDL software error copyir.com
There is a mismatch between the control software of the machine and the PDL control software in regard to version copyir.com – Execute PDL resetting copyir.com – Turn on the power once again copyir.com – Execute system formatting (allفتوکپی کانون , and reinstall the system copyir.com
E730-B013 There is a PDL software error copyir.com
Corruption in the font data – Turn on the power once again copyir.com – Re-install the Software copyir.com – Execute system formatting (allفتوکپی کانون , and reinstall the system copyir.com
E732-0001 There is an error in the communication with the scanner copyir.com
There is a DDI-S communication error copyir.com – Check the connector used to connected the scanner copyir.com – Check the power supply of the scanner (to see if initialization takes place at startupفتوکپی کانون copyir.com – Replace the reader controller, scanner board, or main controller PCB as necessary copyir.com
E733-0000 There is an error in the communication with the printer copyir.com
At startup, communication with the printer fails copyir.com – Check the connector used to connect to the printer copyir.com – Check the power supply of the printer (to see if initialization takes place at startupفتوکپی کانون copyir.com – Replace the DC controller or the main controller PCB copyir.com
E733-0001 There is an error in the communication with the printer copyir.com
There is a DDI-P communication error copyir.com – Check the connection with the printer copyir.com – Check the power supply of the printer (to see if initialization takes place at startupفتوکپی کانون copyir.com – Replace the DC controller or the main controller PCB copyir.com
E740-0002 There is an error on the Ethernet board copyir.com
The MAC address is illegal copyir.com – Replace the main controller PCB copyir.com
E744 There is an error in the language file/boot ROM copyir.com – Download a language file of the correct version copyir.com
E745 There is a fault on the TokenRing board – Disconnect and then connect the TokenRing board copyir.com – Replace the TokenRing board copyir.com
E746-0003 The accessories board is of the wrong type copyir.com
?At startup, a board for a different model has been detected copyir.com – Replace the UFR board of the correct type (modelفتوکپی کانون copyir.com
E748-1001 Mismatch in controller board and SDRAM size?
There is a mismatch between the control board and the SDRAM copyir.com – Check the correct combination between main controller PCB and SDRAM copyir.com
E800-0000 There is an error in the auto power-off circuit copyir.com
An open circuit is detected in the auto power-off circuit for 3 sec or more copyir.com – Turn on the power once again copyir.com – Check if the connector (J505فتوکپی کانون of theDC controller PCB is mounted properly copyir.com – Check if the connector (J1719فتوکپی کانون of the relay PCB is mounted properly copyir.com – Replace the relay PCB copyir.com – Replace the DC controller PCB copyir.com
E804-0000 There is an error in the system fan/the power supply cooling fan (1 and 2فتوکپی کانون copyir.com
The lock signal is detected for 5 sec or more although the power supply cooling fan (1 and 2فتوکپی کانون is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the power supply cooling fan (1 and 2فتوکپی کانون fan copyir.com – Check if the connector (J505فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the power supply cooling fan (1/2فتوکپی کانون copyir.com – Replace the DC controller PCB copyir.com
E804-0004 There is an error in the system fan/the power supply cooling fan (1 and 2فتوکپی کانون copyir.com
The reading of the ambient temperature of the main controller is 80 degrees or higher copyir.com – Check if there is no foreign material in the rotation assembly of the system fan copyir.com – Check if the connector (J1028فتوکپی کانون of the main controller PCB is mounted properly copyir.com – Replace the sysytem fan copyir.com – Replace the main controller PCB copyir.com Caution In the case of a fault in the system fan, the data will be indicated in the form of an alarm (0008040004; ALARM-2فتوکپی کانون copyir.com
E805-0001 The rotation of the fixing assembly heat discharging fan and separation heat discharging fan is faulty copyir.com
The lock signal is detected for 5 sec or more although the fixing assembly heat discharging fan is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the fixing assembly heat discharging fan copyir.com – Check if the connector (J503فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the fixing assembly heat discharging fan copyir.com – Replace the DC controller PCB copyir.com
E805-0002 The rotation of the fixing assembly heat discharging fan and separation heat discharging fan is faulty copyir.com
The lock signal is detected for 5 sec or more although the separation heat discharging fan is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the separation heat discharging fan copyir.com – Check if the connector (J1112فتوکپی کانون of the reader controller PCB is mounted properly copyir.com – Replace the separation heat discharging fan copyir.com – Replace the reader controller PCB copyir.com
E820-0000 The rotation of the drum fan is faulty copyir.com
The lock signal is detected for 5 sec or more although the drum fan is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the drum fan copyir.com – Check if the connector (J512فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the drum fan copyir.com – Replace the DC controller PCB copyir.com
E823-0000 The rotation of the pre-transfer charging assembly fan is faulty copyir.com
The lock signal is detected for 5 sec or more although the pre-transfer charging assembly fan is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the pre-transfer charging assembly fan copyir.com – Check if the connector (J504فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the pre-transfer charging assembly fan copyir.com – Replace the DC controller PCB copyir.com
E830-0000 The rotation of the separation fan is faulty copyir.com
The lock signal is detected for 5 sec or more although the separation cooling fan is being driven copyir.com – Check if there is no foreign material in the rotation assembly of the separation cooling fan copyir.com – Check if the connector (J509فتوکپی کانون of the DC controller PCB is mounted properly copyir.com – Replace the separation cooling fan copyir.com – Replace the DC controller PCB copyir.com