ریکو آفشیو Ricoh Aficio 1035P

ایرادات ریکو براساس کد می باشد. شرکت کپی ایران در نظر دارد تمامی سرویس مانوئلها و رفع ایرادات را در اختیار شما عزیزان قرار دهد.

 

101    Exposure lamp error
• The standard white level was not detected properly when scanning the white plate ( کپی ایران )     • Exposure lamp defective • Lamp stabilizer defective • Exposure lamp connector defective • Standard white plate dirty • Scanner mirror or scanner lens out of position or dirty • SBU defective
120    Scanner home position error 1
• The scanner home position sensor does not detect the on condition during initialization or copying ( کپی ایران )     • SIB or scanner drive motor defective • Scanner motor defective • Harness between SIB and scanner drive motor disconnected • Harness between SIB and scanner drive motor power source disconnected • Scanner HP sensor defective • Harness between SIB and HP sensor disconnected • Scanner wire, timing belt, pulley, or carriage defective
121    Scanner home position error 2
• The scanner home position sensor does not detect the off condition during initialization or copying ( کپی ایران )     • SIB or scanner motor drive board defective • Scanner motor defective • Harness between SIB and scanner drive motor disconnected • Harness between SIB and scanner drive motor power source disconnected • Scanner HP sensor defective • Harness between SIB and scanner HP sensor disconnected • Scanner wire, timing belt, pulley, or carriage defective
130    SBU defective
• Within 1 second after power on, the SOUT signal does not go high, or within 1 second after power on the SOUT signal goes high, but the SBU ID could not be read after two attempts ( کپی ایران )     • SBU defective • BICU defective • Harness between SBU and BICU disconnected or damaged
131    F-Gate asserts during shading
• F-Gate was asserted by the DF during shading ( کپی ایران )     • While scanning at the DF, a software setting procedure caused an error ( کپی ایران )  You must reboot the machine ( کپی ایران )
302    Charge roller current leak
A charge roller current leak signal was detected ( کپی ایران )     • Charge roller damaged • High voltage supply board defective • PCU harness defective or disconnected
304    Charge roller current correction error
• The charge roller bias correction is performed twice even if the maximum charge roller bias (-2000V) is applied to the roller ( کپی ایران )     • ID sensor defective
320    Polygon motor error
• The polygon motor does not reach its operating speed within 25 seconds after the polygon motor on signal, or the lock signal is still activated for more than 2 seconds after the polygon motor off signal ( کپی ایران )     • Cable at the polygon mirror motor disconnected or defective • Polygon motor or polygon motor driver defective • Polygon motor drive pulse not output correctly • LOCK signal could not be detected
321    F-Gate error: No laser writing signal
• The laser writing signal (F-GATE) does not go to LOW for more than 30 seconds after the copy paper reaches the registration sensor ( کپی ایران )     • BICU board defective • PCI harness between the controller board and the BICU defective or disconnected
322    1st laser synchronization error
• The 1st laser synchronization signal cannot be detected by the main scan synchronization detector board even if the laser diodes are activated ( کپی ایران )     • Poor cable connection between the laser synchronization detector board and the LD unit ( کپی ایران )  • Laser synchronization detector board out of position and angle of reflection not correct • Laser synchronization detector board defective • LD unit defective
323    LD drive current too high
• The LD drive board applies more than 100 mA to the LD ( کپی ایران )     • LD unit defective (not enough power, due to aging) • Poor connection between the LD unit and the BICU board • BICU defective
326    2nd laser synchronization error
The 2nd laser synchronization signal cannot be detected by the main scan synchronization detector board even if the laser diodes are activated ( کپی ایران )     • Poor connection between the laser synchronization detector board and the LD unit ( کپی ایران )  • Laser synchronization detector board out of position • Laser synchronization detector board defective • LD unit defective
327    LD unit home position error 1
The LD unit home position sensor does not detect an on condition when the LD unit moves to its home position ( کپی ایران )     • HP sensor/harness defective • LD unit home position sensor defective • LD positioning motor harness defective • LD unit movement blocked because of incorrect connector routing
328    LD unit home position error 2
The LD unit home position sensor does not detect an off condition when the LD unit moves from its home position ( کپی ایران )     • HP sensor/harness defective • LD positioning/harness motor defective • LD unit movement blocked because of incorrect connector routing
329    LD unit beam pitch adjusted incorrectly
The LD unit HP sensor does not detect the ON condition while changing the LD unit position for correcting the LD position or changing the dpi ( کپی ایران )     • After initialization of the SP modes, SP2-109-3 or SP2-109-4 was not executed ( کپی ایران )  • The harness is blocking the LD drive (PCB), preventing adjustment of the pitch
350    ID sensor pattern test error
• One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern ( کپی ایران )  1) Vsp >=2 ( کپی ایران ) 5V 2) Vsg <= 2 ( کپی ایران ) 5V 3) Vsp = 0V 4) Vsg = 0V    • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • High voltage supply board defective • ID sensor dirty • Defect at ID sensor pattern writing area of the drum
351    ID sensor Vsg test error
When the ID sensor was checked, the ID sensor output voltage was 5 ( کپی ایران ) 0V while the PWM signal input to the ID sensor was 0 ( کپی ایران )     • ID sensor defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Scanning system defective • High voltage supply board defective • ID sensor dirty • Defect at the ID sensor pattern writing area of the drum
352    ID sensor, pattern edge detect error
The ID sensor pattern edge voltage is detected to be not 2 ( کپی ایران ) 5V twice consecutively during an 800 ms interval ( کپی ایران )     • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • High voltage supply board defective • Dirty ID sensor • Defect at the ID sensor pattern writing area of the drum
353    ID sensor, LED current abnormal at initialization
• One of the following ID sensor output voltages is detected at ID sensor initialization ( کپی ایران )  1) Vsg < 4 ( کپی ایران ) 0V when the maximum PWM input (255) is applied to the ID sensor ( کپی ایران )  2) Vsg >= 4 ( کپی ایران ) 0V when the minimum PWM input (0) is applied to the ID sensor ( کپی ایران )     • ID sensor defective • ID sensor harness defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Exposure system defective • High voltage supply board defective • Dirty ID sensor
354    ID sensor timeout abnormal at adjustment
Vsg falls out of the adjustment target (4 ( کپی ایران ) 0 +- 0 ( کپی ایران ) 2V) at the start of Vsg checking after 20 seconds    • ID sensor defective • ID sensor harness defective • ID sensor connector defective • I/O board (IOB) defective • Exposure system defective • Poor ID sensor connector connection • High voltage supply board defective • Dirty ID sensor
390    TD sensor error: Test value abnormal
The TD sensor output voltage is less than 0 ( کپی ایران ) 5V or more than 5 ( کپی ایران ) 0V after 10 consecutive times during copying ( کپی ایران )     • TD sensor defective • TD sensor not connected or connector damaged • Poor connection between the TD sensor and the I/O board (IOB) • I/O board (IOB) defective • Toner supply defective
391    TD sensor error: Auto adjust error
During automatic adjustment of the TD sensor, output voltage is less than 1 ( کپی ایران ) 8V or more than 4 ( کپی ایران ) 8V during TD sensor initial setting ( کپی ایران )     • TD sensor abnormal • TD sensor disconnected • Poor TD sensor connection • I/O board (IOB) defective • Toner supply defective
395    Development output abnormal
A development bias leak signal is detected ( کپی ایران )  High voltage output to the development unit exceeded the upper limit (65%) for 60 ms ( کپی ایران )     • High voltage supply board defective • Poor connection at the development bias terminal • Poor connection at the high voltage supply board
401    Transfer roller leak detected
A transfer roller current leak signal is detected ( کپی ایران )     • High voltage supply board defective • Poor cable connection or defective cable • Transfer connector defective
402    Transfer roller open error
The transfer roller current feedback signal is not detected ( کپی ایران )     • High voltage supply board defective • Transfer connector cable defective • Transfer connector defective • Poor PCU connection
403    Transfer belt position sensor error
The transfer belt position sensor does not activate even if the transfer belt contact clutch has been switched on twice and rotated once ( کپی ایران )     • Main motor/drive malfunction • Transfer belt contact clutch defective • Transfer belt position sensor defective • Harness disconnected
405    Transfer belt error
The transfer belt does not move away from the drum during ID sensor pattern checking ( کپی ایران )     • Main motor/drive malfunction • Transfer belt position sensor defective • Poor transfer belt position sensor connection • Transfer belt contact clutch defective
440    Main motor lock
A main motor lock signal is not detected within 2 seconds after the main motor turns on ( کپی ایران )     • Too much load on the drive mechanism • Main motor defective
490    Exhaust fan motor lock
An exhaust fan motor lock signal is not detected within 5 seconds after the exhaust fan motor turns on    • Too much load on the drive mechanism • Exhaust fan motor defective or a loose object is interfering with the fan • Poor fan motor connector connection
492    Cooling fan motor lock
A cooling fan motor lock signal is not detected within 5 seconds after the cooling fan motor turns on ( کپی ایران )     • Too much load on the drive mechanism • Cooling fan motor defective or a loose object is interfering with the fan • Poor fan motor connector connection
501    1st tray lift malfunction
The paper height sensor is not activated after the tray lift motor has been on for 10 seconds ( کپی ایران )  If the main power switch is turned on when the paper is already at the feed height, the paper height position is detected again ( کپی ایران )  At this time, the paper height sensor should de-activate within 5 seconds after the paper bottom plate starts to drop ( کپی ایران )  If it does not deactivate within 5 s four times consecutively, a message will prompt the user to reset Tray 1 ( کپی ایران )  After two attempts to release the error by re-setting the paper tray, if this does not solve the problem then this SC is displayed ( کپی ایران )     • Lift motor malfunction or disconnected • Height sensor abnormal, or connector loose • Loose paper or object between the tray and motor • Pick-up arm malfunction
502    2nd tray lift malfunction
The paper height sensor is not activated after the tray lift motor has been on for 10 seconds ( کپی ایران )  If the main power switch is turned on when the paper is already at the feed height, the paper height position is detected again ( کپی ایران )  At this time, the paper height sensor should de-activate within 5 seconds after the paper bottom plate starts to drop ( کپی ایران )  If it does not deactivate within 5 s four times consecutively, a message will prompt the user to reset Tray 2 ( کپی ایران )  After two attempts to re-set the paper tray, if this does not solve the problem then this SC is displayed ( کپی ایران )     • Lift motor abnormal or disconnected • Height sensor defective or disconnected • Loose paper or object between the tray and motor • Pick-up arm malfunction
503    3rd tray lift malfunction (optional paper tray unit)
The paper height sensor is not activated after the tray lift motor has been on for 13 seconds ( کپی ایران )  If the main power switch is turned on when the paper is already at the feed height, the paper height position is detected again ( کپی ایران )  At this time, the paper height sensor should de-activate within 5 seconds after the paper bottom plate starts to drop ( کپی ایران )  If it does not deactivate within 5 s four times consecutively, the tray lift motor halts ( کپی ایران )  After two attempts to re-set the paper tray, if this does not solve the problem, then this SC is displayed and tray control halts ( کپی ایران )     • Tray lift motor defective or disconnected • Height sensor defective or disconnected
504    4th tray lift malfunction (optional paper tray unit)
The paper height sensor is not activated after the tray lift motor has been on for 13 seconds ( کپی ایران )  If the main power switch is turned on when the paper is already at the feed height, the paper height position is detected again ( کپی ایران )  At this time, the paper height sensor should de-activate within 5 seconds after the paper bottom plate starts to drop ( کپی ایران )  If it does not deactivate within 5 s four times consecutively, the tray lift motor halts ( کپی ایران )  After two attempts to re-set the paper tray, if this does not solve the problem, then this SC is displayed and tray control halts ( کپی ایران )     • Tray lift motor defective or disconnected • Height sensor defective or disconnected
506    Paper tray unit main motor lock (optional paper tray)
A main motor lock signal is detected for more than 50 ms during rotation ( کپی ایران )     • Paper tray unit main motor defective • Paper tray unit main motor connection loose • Too much load on the drive mechanism
507    LCT main motor lock (optional LCT)
A main motor lock signal is detected for more than 50 ms during rotation ( کپی ایران )     • LCT main motor defective • Paper tray unit main motor connection loose • Too much load on the drive mechanism
510    LCT tray malfunction
1) The LCT lift sensor does not activate for more than 18 seconds after the LCT lift motor turned on ( کپی ایران )  2) The LCT lower limit sensor does not activate for more than 18 seconds after the LCT lift motor turned on ( کپی ایران )  3) The LCT lift sensor is already activated when the LCT lift motor turns on ( کپی ایران )  4) After the paper end sensor is actuated while the tray is raising, the upper limit sensor is not actuated within 5 s ( کپی ایران )  A message is displayed to remind the user to set the paper and tray control halts ( کپی ایران )  Resetting the display is done by opening and closing the LCT door ( کپی ایران )  5) The 4) state has been detected 3 times in succession ( کپی ایران )     • LCT lift motor defective or disconnected ( کپی ایران )  • Upper limit sensor defective or disconnected • Pick-up solenoid defective or disconnected • Paper end sensor defective
541    Fusing thermistor open
The fusing temperature detected by the thermistor was below 7C (44 ( کپی ایران ) 6F) for 5 seconds, or 2 seconds after reaching 45C (113F) the temperature does not reach an additional 15C (59F) after checking five times at 0 ( کپی ایران ) 1 intervals ( کپی ایران )     • Fusing thermistor disconnected • Fusing thermistor connector defective • Fusing thermistor damaged or warped • Fusing temperature œ15% less than the standard input voltage
542    Fusing temperature warm-up error
The fusing temperature does not reach the fusing standby temperature of 45C (113F) within 9 seconds [for the B003/B006 (35 cpm)]/14 seconds [for the B004/B007 (45 cpm)] after switching on the main power or closing the front cover, or 40 seconds after reaching 50C the fusing roller does not reach warm-up temperature ( کپی ایران )     • Fusing lamp defective • Poor fusing unit connector • Thermistor warped or broken • Thermostat has tripped • BICU defective • Power supply board defective
543    Fusing overheat error (software detection)
A fusing temperature of over 230C (446F) is detected for 5 seconds by the fusing thermistors at the center or at either end of the fusing roller ( کپی ایران )     • Power supply unit defective • I/O board (IOB) defective • BICU defective • Fusing thermistor defective
544    Fusing overheat error (hardware circuit detection)
The dual monitoring circuitry of the BICU detects extremely high temperature and tripped the relay circuit off ( کپی ایران )     • Power supply unit defective • I/O board (IOB) defective • BICU defective • Fusing thermistor defective
545    Fusing lamp remains on
After warm-up the fusing lamp remains at full power for 10 seconds without the hot roller rotating ( کپی ایران )     • Thermistor is out of position ( کپی ایران )
546    Fusing ready temperature unstable
The fusing temperature is fluctuating ( کپی ایران )     • Thermistor connection loose • Fusing unit connector loose
547    Zero cross signal malfunction
The applied power supply ac frequency was detected at over 66Hz or below 45Hz, and the zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on ( کپی ایران )     • Power supply board defective • Noise on the ac power line
548    Fusing unit installation error
The machine cannot detect the fusing unit when the front cover and right cover are closed ( کپی ایران )     • Fusing unit is not installed • Fusing unit connection loose
599    1-bin tray motor lock (optional 1-bin tray unit)
A 1-bin tray motor lock signal is not detected for more than 300 ms during rotation ( کپی ایران )     • 1-bin tray motor locked from overload • 1-bin tray motor defective • 1-bin tray motor connection loose
601    Communication error between BICU and scanner unit
Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line ( کپی ایران )     • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
610    Communication timeout error between BICU and ADF
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF ( کپی ایران )     • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective
611    Communication break error between BICU and ADF
The BICU receives a break signal from the ADF main board ( کپی ایران )     • Serial line connecting BICU and ADF unstable • External noise • ADF main board defective • BICU board defective
612    Communication command error between BICU and ADF
The BICU sends a command to the ADF main board that it cannot execute ( کپی ایران )     • Abnormal operation performed by software
620    Communication timeout error between BICU and finisher or mailbox
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the finisher or mailbox ( کپی ایران )     • Serial line connecting BICU and finisher unstable • External noise • BICU board and finisher main board connection defective or loose • Finisher main board defective • BICU board defective
621    Communication timeout error between BICU and finisher or mailbox
A break (low) signal was received from the finisher or the mailbox ( کپی ایران )     • Serial line connecting BICU and finisher unstable • External noise
623    Communication timeout error between BICU and paper tray unit
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the paper tray unit ( کپی ایران )     • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray main board connection defective or loose • Paper tray main board defective • BICU board defective
624    Communication break error between BICU and paper tray unit
The BICU cannot communicate with the paper tray unit normally as a result of receiving a break signal ( کپی ایران )     • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and LCT main board connection defective or loose • Optional paper feed unit interface board defective • BICU board defective
626    Communication timeout error between BICU and LCT
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the LCT ( کپی ایران )     • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
627    Communication break error between BICU and LCT
The BICU cannot communicate with the LCT unit normally as a result of receiving a break signal ( کپی ایران )     • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
630    SC630 Communication failure with CSS (RSS)
The communication from the copier was detected as abnormal at the CSS center ( کپی ایران )  This error occurs when the acknowledge signal from the LADP does not complete normally ( کپی ایران )     • Occurred with a SC call, CC call, Supply Management call, User call, or CE call ( کپی ایران )  • Timeout while no response from the LADP, and signal on the RS-485 line between PI and LADP is abnormal ( کپی ایران )
640    BICU control data transfer sumcheck error
A sampling of control data sent from the BICU to the controller reveals a sumcheck error ( کپی ایران )  Only the logging count is performed ( کپی ایران )     • Controller board defective • External noise • BICU board defective
641    BICU control data transfer abnormal
A sampling of the control data sent from the BICU reveals an abnormality ( کپی ایران )     • Controller board defective • External noise • BICU board defective
670    Engine response error
After powering on the machine, a response is not received from the engine within the specified time ( کپی ایران )     • BICU installed incorrectly • BICU defective • Controller board defective
672    Controller-to-operation panel communication error at startup
After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup ( کپی ایران )     • Controller stall • Controller board installed incorrectly • Controller board defective • Operation panel connector loose or defective
690    GAVD block I2C bus error    • I2C bus on BICU defective
691    GAVD FCI block I2C bus error    • I2C bus on BICU defective
692    CDIC GAVD block I2C bus error    • I2C bus on BICU defective
700    ARDF original pick-up malfunction
After the pick-up motor is turned on, the original stopper HP sensor is not detected ( کپی ایران )     • Original stopper HP sensor (output abnormal) • Pick-up motor defective (not rotating) • Timing belt out of position • ADF main board defective
701    ARDF original pick-up/paper lift mechanism malfunction
The original pick-up HP sensor does not activate three times consecutively after the pick-up motor has turned on ( کپی ایران )     • Original pick-up HP sensor defective ( کپی ایران )  • Pick-up motor defective • ADF main board defective
722    Finisher jogger motor error
The finisher jogger HP sensor does not return to the home position, or move out of the home position, within the specified time ( کپی ایران )     • Jogger HP sensor defective • Jogger motor defective
724    Finisher staple hammer motor error
Stapling does not finish within 600 ms after the staple hammer motor turned on ( کپی ایران )     • Staple jam • Stapler overload caused by trying to staple too many sheets • Staple hammer motor defective
725    Finisher stack feed-out motor error
The stack feed-out belt HP sensor does not activate within a certain time after the stack feed-out motor turned on ( کپی ایران )     • Stack feed-out HP sensor defective • Stack feed-out motor overload • Stack feed-out motor defective
726    Finisher shift tray 1 lift motor error
Tray shift does not finish within the specified time after the shift motor turned on, or the stack height sensor does not activate within the specified time after the shift tray lift motor turned on ( کپی ایران )     • Shift motor defective or overloaded • Shift tray lift motor defective or overloaded
727    Finisher stapler rotation motor error
Stapler rotation does not finish within the specified time after the staple rotation motor turned on, or the stapler does not return to its home position within the specified time after stapling finished ( کپی ایران )     • Stapler rotation motor defective or overloaded • Stapler rotation motor connection loose or connector defective
729    Finisher punch motor error
After the punch motor is turned on, the punch HP sensor does not activate within the specified time ( کپی ایران )     • Punch motor defective or overloaded • Punch HP sensor defective • Punch motor connection loose or connector defective
730    Finisher stapler positioning motor error
After the stapler motor is turned on, the stapler does not return to its home position within the specified time, or the stapler HP sensor does not activate within the specified time after the stapler motor is turned on ( کپی ایران )     • Stapler positioning motor defective or overloaded • Stapler HP sensor defective • Stapler positioning motor connection loose or connector defective
731    Finisher exit guide open/close motor error
After the finisher exit guide open/close motor is turned on, the open/close sensor does not activate within the specified time ( کپی ایران )     • Finisher exit guide open/close motor defective • Open/close sensor defective
732    Finisher upper tray shift motor error
The upper tray shift motor does not stop within the specified time ( کپی ایران )     • Upper tray shift motor defective or overloaded • Upper tray shift sensor defective
733    Finisher lower tray lift motor error
The stack height sensor does not activate within a certain time period after the lower tray lift motor turned on ( کپی ایران )     • Lower tray lift motor defective or overloaded • Upper stack height sensor defective • Lower tray lower limit sensor defective
734    Finisher lower tray shift motor error
The lower tray shift motor driving the lower tray does not stop within the specified time ( کپی ایران )     • Lower tray shift motor defective or overloaded • Lower tray shift sensor defective
800    Startup without video output end error (K)
Video transfer to the engine is started, but a video transmission end command was not issued by the engine within the specified time ( کپی ایران )     • Control board defective
804    Startup without video input end (K)
A video transmission was requested from the scanner, but a video transmission end command was not issued by the scanner within the specified time ( کپی ایران )     • Control board defective
819    Kernel mismatch error
Software bug    • Software application error
820    Self-Diagnostic Error: CPU
The central processing unit returned an error during the self-diagnostic test ( کپی ایران )     • Controller board defective • Software defective
821    Self-Diagnostic Error: ASIC
The ASIC returned an error during the self-diagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range ( کپی ایران )     • Controller board defective
822    Self-Diagnostic Error: HDD
The hard disk drive returned an error during the self-diagnostic test ( کپی ایران )     • HDD defective • HDD connector defective • Controller board defective
823    Self-diagnostic Error: NIB
The network interface board returned an error during the self-diagnostic test ( کپی ایران )     • Network interface board defective • Controller board defective
824    Self-diagnostic Error: NVRAM
The resident non-volatile RAM returned an error during the self-diagnostic test ( کپی ایران )     • NVRAM damaged or abnormal • Backup battery has discharged • NVRAM socket damaged
826    Self-diagnostic Error: NVRAM/Optional NVRAM
The NVRAM or optional NVRAM returned an error during the self-diagnostic test ( کپی ایران )     • NVRAM defective
827    Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test ( کپی ایران )     • Memory malfunction
828    Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test ( کپی ایران )     • Controller board defective • Firmware defective
829    Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test ( کپی ایران )     • RAM DIMM defective • Controller board defective
835    Self-Diagnostic Error: Parallel Interface
Loopback test error ( کپی ایران )     • Loopback connector not detected • IEEE1284 connector defective • Controller board defective
836    Self-diagnostic Error: Resident Font ROM
The resident font ROM returned an error during the self-diagnostic test ( کپی ایران )     • Font ROM defective
837    Self-diagnostic Error: Optional Font ROM
The optional font ROM returned an error during the self-diagnostic test ( کپی ایران )     • Font ROM defective
838    Self-diagnostic Error: Clock Generator
Verify error occurred when setting data was read from the clock generator via the I2C bus ( کپی ایران )     • Clock generator abnormal • I2C bus abnormal • CPU port for the I2C bus abnormal
850    Network I/F Abnormal    • NIB defective • Controller board defective
851    IEEE 1394 I/F Abnormal    • IEEE1384 interface board defective • Controller board defective
860    Startup without HD connection at main power on
The hard disk connection is not detected ( کپی ایران )     • Cable between HDC and HD loose or defective • HD power connector loose or defective • HD defective • HDC defective
861    Startup without HD detection at power key on
The hard disk connection is not detected ( کپی ایران )     • Cable between HDC and HD loose or defective • HD power connector loose or defective • HD defective • HDC defective
862    Maximum number of bad sectors detected on HD
Up to 101 bad sectors have appeared in the area on the hard disk where image data is archived, and the hard disk may require replacement ( کپی ایران )     • SC863 returned while reading data from the HD and the number of registered bad sectors reached 101 ( کپی ایران )
863    Startup without HD data lead
Data stored on the hard disk is not read correctly ( کپی ایران )     • A bad sector occurred during operation of the HD
864    HD data CRC error
During operation of the HD, the HD responded with a CRC error ( کپی ایران )     • Data transfer was abnormal in the data read from the HD ( کپی ایران )
865    HD access error
The hard disk detected an error ( کپی ایران )     • Error detected other that the bad sectors error (SC863) or the CRC error (SC864)
900    Electronic total counter error
The value of the total counter has already exceeded 9,999,999    • NVRAM defective
901    SC901 Mechanical total count error
The IO board cannot receive the mechanical total count data ( کپی ایران )     • Mechanical total counter defective
951    F-gate error at write request
After the IPU receives an F-gate signal, it receives another F-gate signal ( کپی ایران )     • Software defective • BICU defective
953    Scanner setting error
The IPU does not respond with the scanner setting signal required to start scanning processing ( کپی ایران )     • Software defective
954    Printer setting error
The IPU does not respond with the settings that are required to start image processing by the printer ( کپی ایران )     • Software defective
955    Memory setting error
The IPU does not respond with the settings that are required to start image processing using the memory ( کپی ایران )     • Software defective
964    Printer ready error
The printer ready signal is not generated within 17 seconds after the IPU received the print start signal ( کپی ایران )     • Software defective
984    Print image data transfer error
The image transfer from the controller to the engine via the PCI bus does not end within 15 s after starting ( کپی ایران )     • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective
985    Scanner image data transfer error
The image transfer from the engine to the controller via the PCI bus does not end within 3 s after starting ( کپی ایران )     • Controller board defective • BICU defective • Connectors between BICU and controller loose or defective • SIB defective
986    Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module ( کپی ایران )     • Software defective
990    Software performance error
The software attempted to perform an unexpected operation ( کپی ایران )     • Software defective • Internal parameter incorrect • Insufficient working memory • When this SC occurs, the file name, address, and data will be stored in NVRAM ( کپی ایران )  This information can be checked by using SP7-403 ( کپی ایران )  Note the above data and the situation in which this SC occurs ( کپی ایران )  Then report the data and conditions to your technical control center ( کپی ایران )
991    Software continuity error
The software attempted to perform and unexpected operation ( کپی ایران )  However, unlike SC990, the object of the error is continuity of the software ( کپی ایران )     • Software bug • Internal parameter incorrect • Insufficient working memory
996    FCU board error
FCU board is connected but not ready ( کپی ایران )     • FCU board defective and requires replacement • Firmware incorrect
997    Application function selection error
The application selected by a key press on operation panel does not start or ends abnormally ( کپی ایران )     • Software defective • An option required by the application (RAM, DIMM, board) is not installed
998    Application start error
After power on the application does not start within 60 s ( کپی ایران )  (All applications neither start nor end normally ( کپی ایران ) )    • Software defective • An option required by the application (RAM, DIMM, board) is not installed
999    Program download error
The download (program, print data, language data) from the IC card does not execute normally ( کپی ایران )     • Board installed incorrectly • BICU defective • IC card defective • NVRAM defective • Loss of power during downloading • Important Notes About SC999 • Primarily intended for operating in the download mode, logging is not performed with SC999 ( کپی ایران )  • If the machine loses power while downloading, or if for some other reason the download does not end normally, this could damage the controller board or the PCB targeted for the download and prevent subsequent downloading ( کپی ایران )  If this problem occurs, the damaged PCB must be replaced ( کپی ایران )