ریکو آفشیو Ricoh Aficio 1060

ایرادات ریکو براساس کد می باشد. شرکت کپی ایران در نظر دارد تمامی سرویس مانوئلها و رفع ایرادات را در اختیار شما عزیزان قرار دهد.

 

 

 

101    Exposure Lamp Error
At trigger on, the lamp was not detected on(copyir.com )    • Exposure lamp defective
• Lamp regulator defective
• Lamp regulator harness damaged, disconnected
• Dirty standard white plate
• Scanner mirror dirty or out of position
• Lens dirty, out of position
• SBU board defective
120    Scanner home position error 1
The scanner HP sensor does not detect the on condition during initialization or copying(copyir.com )    • BCU, SDRB (Scanner Driver Board) defective
• Scanner motor defective
• Harness between BCU, SDRB, scanner motor disconnected(copyir.com )
• Scanner HP sensor defective(copyir.com )
• Harness between scanner HP sensor and BCU disconnected(copyir.com )
• Scanner wire, timing belt, pulley, carriage installed incorrectly(copyir.com )
121    Scanner home position error 2
The scanner HP sensor does not detect the off condition during initialization or copying(copyir.com )    • BCU, SDRB (Scanner Driver Board) defective
• Scanner motor defective
• Harness between BCU, SDRB, scanner motor disconnected
• Scanner HP sensor defective
• Harness between scanner HP sensor and BCU disconnected
• Scanner wire, timing belt, pulley, carriage installed incorrectly(copyir.com )
122    Scanner home position error 3
The scanner home position sensor does not detect the on condition during original scanning(copyir.com )    • BCU, SDRB (Scanner Driver Board) defective
• Scanner motor defective
• Harness between BCU, SDRB, scanner motor disconnected
• Scanner HP sensor defective
• Harness between scanner HP sensor and BCU disconnected
• Scanner wire, timing belt, pulley, carriage installed incorrectly
123    Scanner home position error 4
The scanner home position sensor does not detect the off condition during original scanning(copyir.com )    • BCU, SDRB (Scanner Driver Board) defective
• Scanner motor defective
• Harness between BCU, SDRB, scanner motor disconnected
• Scanner HP sensor defective
• Harness between scanner HP sensor and BCU disconnected
• Scanner wire, timing belt, pulley, carriage installed incorrectly(copyir.com )
143    SBU auto adjust error
Automatic adjustment of the SBU fails when the machine is switched on(copyir.com )    • Exposure lamp defective
• Exposure lamp regulator defective
• Harness between exposure lamp and lamp regulator is disconnected
• White plate installed incorrectly or is dirty
• Scanning mirrors of the exposure unit are dirty or out of position
• SBU board defective
• VIB board defective(copyir.com )
• Harness between SBU, VIB disconnected
• Harness between VIB, BCU disconnected
144    SBU transmission error
After the SBU switches on, the BCU detects one of the following conditions on the SBU:
• 1 s after power on, the SYDI signal does not go high, even after 1 retry(copyir.com )
• 1 s after power on, the SYDI signal goes high, but the SBU ID could not be read after 3 attempts(copyir.com )    • SBU defective
• VIB defective
• Harness (40-pin shielded) between the SBU, VIB is disconnected
• Harness (shielded cable) between the VIB, BCU is disconnected
165    Copy data security unit error B828
The copy data security option is installed by not operating correctly(copyir.com )    • Copy data security card corrupted
• The board is not installed or the board is defective
• IPU board defective
181    CIS lamp abnormal
After the CIS lamp trigger goes on, the CIS lamp is not detected on(copyir.com ) Detecting the lamp on or off determines the peak white level value for shading correction(copyir.com ) (If the peak level is determined to be below a certain level, the CIS lamp is judged to be off(copyir.com ))    • CIS lamp defective
• CIS power supply board defective
• CIS lamp regulator defective
• Harness between lamp and lamp regulator is disconnected(copyir.com )
• Harness between CIS, ADF is disconnected
• CIS exposure glass dirty(copyir.com )
• White roller dirty or installed incorrectly
• CIS unit defective
183    CIS auto adjust error
Automatic adjustment of the CIS unit failed(copyir.com )    • CIS unit defective
• CIS exposure glass dirty
• White roller dirty or installed incorrectly
184    CIS transmission error
When the CIS is powered on, the ADF detects one of the following abnormal conditions on the CIS unit:
• The SOUT signal does not go high within 1 s after power on(copyir.com )
• The SOUT signal goes high within 1 s after power on, but the SBU ID cannot be read after 3 attempts(copyir.com )    • CIS unit defective
• Harness between the CIS, ADF is disconnected
202    Polygon mirror motor error 1: Timeout at ON
The polygon mirror motor unit did not enter “Ready” status within 20 sec(copyir.com ) after the motor was turned on, or within 20 sec(copyir.com ) after the speed of rotation was changed(copyir.com )    • The polygon mirror motor PCB connector is loose, broken, or defective
• Polygon mirror motor PCB defective
• Polygon mirror motor defective
• IPU defective
203    Polygon mirror motor error 2: Timeout at OFF
The polygon mirror motor did not leave “Ready” within 3 sec(copyir.com ) after the motor was switched off(copyir.com ) (The XSCRDY signal did not go HIGH (inactive) within 3 sec(copyir.com ))    • The polygon mirror motor PCB connector is loose, broken, or defective
• Polygon mirror motor PCB defective
• Polygon mirror motor defective
• IPU defective
204    Polygon mirror motor error 3: XSCRDY signal error
The polygon mirror motor “Ready” signal went inactive (HIGH) while the motor was operating at normal speed, even though the motor was neither switched off nor was there a request for a change in speed(copyir.com )    • Electrical oise interference on the line with the motor signals
• Polygon mirror motor PCB connector loose, broken, defective
• Polygon mirror motor PCB defective
• Polygon mirror motor defective
205    Polygon mirror motor error 4: Unstable timeout
The “Ready” signal (XSCRDY) was detected as unstable for more than 20 sec(copyir.com ) while the polygon mirror motor was operating at normal speed(copyir.com )    • Electrical noise on the line with the motor signals
• Polygon mirror motor PCB connector loose, broken, defective
• Polygon mirror motor PCB defective
• IPU defective
220    Laser synchronization detection error
The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed(copyir.com ) Note: The unit polls for the signal every 50 ms(copyir.com ) This SC is issued after the 10th attempt fails to detect the signal(copyir.com )    • Laser synchronization board connector loose, broken, defective
• Laser synchronization detection board is not installed correctly (out of alignment)
• Laser synchronization board defective • IPU defective
300    Charge corona output error
The feedback voltage from the charge corona unit is detected too high 9 times    • Charge corona power pack defective
• Charge corona harness disconnected
• Poor charge corona unit connection
303    Charge corona grid leak
When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times(copyir.com )    • Charge corona power pack defective
• Charge corona harness disconnected • Poor charge corona unit connection
304    Charge grid circuit open
When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times(copyir.com ) This feedback voltage is used to update PWM for output control(copyir.com )    • Charge corona unit defective or disconnected
• Charge corona harness defective
• Charge corona power pack is defective(copyir.com )
305    Charge corona wire cleaner error 1
The charge cleaner pad does not arrive at the home position:
• Motor locked within 4 s after switching on, or does not lock within 30 s(copyir.com )
• Motor locked within 10 s after reversing, or does not lock within 30 s(copyir.com )    • Charge corona wire cleaner motor defective
• Motor driver defective
306    Charge corona wire cleaner error 2
Charge coronal motor is disconnected(copyir.com ) (The current at the charge corona motor is detected less than 83 mA(copyir.com ))    • Charge corona wire cleaner motor connector is defective, connected
310    Potential sensor calibration error 1
During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum(copyir.com )    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defecti
311    Potential sensor calibration error 2
During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum(copyir.com )    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
312    Potential sensor calibration error 3
During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage)(copyir.com ) -or- When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800±10 + VL + 130V)    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
• Charge corona unit worn out, dirty
314    Potential sensor calibration error 4
During drum potential sensor calibration when adjusting the drum potential (VH) for LD power adjustment, the first time the VH pattern is made, the drum potential sensor detects that VH is more than 500V: VH > |–500 + VL + 130| V    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• LD defective
315    Potential sensor calibration error 5
During drum potential sensor calibration, when –100V is applied to the drum, the output value is out of the prescribed range    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defectiv
316    Potential sensor calibration error 6
During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range(copyir.com )    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
317    Potential sensor calibration error 7
During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V(copyir.com ) (VL is the potential after exposing a white pattern(copyir.com ))    • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Charge corona power pack defective
• Development power pack defective
321    F-GATE error
The laser writing signal (F-GATE) for the IPU does not go LOW within 60 s(copyir.com )    • BICU board defective
• PCI bus between controller board, BICU board defective
322    Laser synchronization detector error
After the polygon motor reaches standard rotation speed and the LD unit fires for 500 ms, the laser synchronization detector does not generate a signal    • Harness between detector and I/F disconnected or damaged
• Detector is installed incorrectly
• Detector board is defective
• IPU board defective
335    Polygon mirror motor error 1
The ready signal does not go low within 20 s after the polygon mirror motor turns on or changes speed(copyir.com )    • Harness between I/F and polygon motor disconnected or defective
• Polygon motor or polygon motor driver defective
• IPU board defective
336    Polygon mirror motor error 2
The ready signal does not go high within 20 s after the polygonal mirror motor turns off(copyir.com )    • Harness between I/F and polygon motor disconnected or defective
• Polygon motor or polygon motor driver defective
• IPU board defective
337    Polygonal mirror motor error 3
The XSCRDY signal goes high while the polygon mirror motor turns on, even though there was no request to either turn off the motor or change the motor speed(copyir.com )    • Noise on the line where the polygon ready signal (XSCRDY) is transmitted(copyir.com )
• Harness between the polygon motor and I/F disconnected or defective(copyir.com )
• Polygon motor or polygon motor driver defective
338    Polygonal mirror motor error 4
While the polygon motor is rotating, the XSCRDY signal goes high during exposure    • Noise on the linef where the polygon ready signal (XSCRDY) is transmitted(copyir.com )
• Harness between the polygon motor and I/F disconnected or defective(copyir.com )
• Polygon motor or polygon motor driver defective
• IPU board defective
340    TD sensor output error
TD sensor output voltage (Vt), measured during each copy cycle, is detected 10 times at one of the following levels: Vt = 0(copyir.com )5 volts or lower Vt = 4(copyir.com )0 volts or higher    • TD sensor defective
• TD sensor harness disconnected
• TD sensor connector disconnected or defective
• IOB defective
• Toner bottle motor defective Note: When the TD sensor is defective, the toner supply is controlled using pixel count and the ID sensor(copyir.com )
341    TD sensor adjustment error 1
During the TD sensor auto adjustment, the TD sensor output voltage (Vt) is 2(copyir.com )5 volts or higher even though the control voltage is set to the minimum value (PWM = 0)(copyir.com ) When this error occurs, SP2-906-1 reads 0(copyir.com )00V(copyir.com ) Note: This SC is released only after correct adjustment of the TD sensor has been achieved(copyir.com ) Switching the machine off and on will cancel the SC display, but does not release ID sensor toner supply(copyir.com )    • TD sensor defective
• TD sensor harness disconnected
• TD sensor connector disconnected or defective
• IOB defective
• Toner bottle motor defective Note: When the TD sensor is defective, the toner supply is controlled using pixel count and the ID sensor(copyir.com )
342    TD sensor adjustment error 2
During the TD sensor auto adjustment, the TD sensor output voltage (Vt) does not enter the target range (3(copyir.com )0 ± 0(copyir.com )1V) within 20 s(copyir.com ) When this error occurs, the display of SP2-906-1 reads 0(copyir.com )00V(copyir.com ) Note: This SC is released only after correct adjustment of the TD sensor has been achieved(copyir.com ) Switching the machine off and on will cancel the SC display, but does not release ID sensor toner supply(copyir.com )    • TD sensor defective
• TD sensor harness disconnected
• TD sensor connector disconnected or defective
• IOB defective
345    Development output abnormal
The high voltage applied to the development unit is detected 10 times higher than the upper limit (45%) of PWM(copyir.com )    • Development power pack defective
• Development bias leak due to poor connection, defective connector
350    ID sensor error 1
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern(copyir.com ) Vsp (copyir.com ) 2(copyir.com )5V Vsg < 2(copyir.com )5 Vsp = 0V Vsg = 0    • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
351    ID sensor error 2
The ID sensor output voltage is 5(copyir.com )0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern(copyir.com )    • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective • IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
352    ID sensor error 3
For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2(copyir.com )5V or the pattern edge is not detected within 800 ms(copyir.com )    • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
353    ID sensor error 4
One of the following ID sensor output voltages is detected at ID sensor initialization(copyir.com ) (copyir.com ) Vsg < 4(copyir.com )0V when the maximum PWM input (255) is applied to the ID sensor(copyir.com ) (copyir.com ) Vsg (copyir.com ) 4(copyir.com )0V when the minimum PWM input (0) is applied to the ID sensor(copyir.com )    • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
354    ID sensor error 5
Vsg falls out of the adjustment target (4(copyir.com )0 ± 0(copyir.com )2V) during Vsg checking    • ID sensor defective
• ID sensor harness disconnected
• ID sensor connector defective
• IOB defective
• ID sensor pattern not written correctly
• Incorrect image density
• Charge power pack defective
• ID sensor dirty
355    ID sensor error 6
The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of –70V to –400V(copyir.com )    • Potential sensor defective
• Potential sensor harness defective
• Potential sensor disconnected
• IOB defective
• OPC unit connector defective
• Charge corona power pack defective
• Charge corona wire dirty, broken
401    Transfer output abnormal
When the transfer is output, the feedback voltage remains higher than 4V for 60 ms(copyir.com )    • Transfer power pack defective
• Transfer current terminal, transfer power pack disconnected, damaged connector
402    Transfer output abnormal release detection
When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM(copyir.com )    • Transfer power pack defective
• Transfer unit harness disconnected
• Transfer connector loose, defective
430    Quenching lamp error
At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than –400V, the prescribed value(copyir.com )    • Quenching lamp defective
• Quenching lamp harness disconnected
• Quenching lamp connector loose,
defective
440    Main motor lock
The main motor lock signal remains low for 2 seconds while the main motor is on(copyir.com )    • Drive mechanism overloaded
• Motor driver board defective
441    Development motor lock
The development motor lock signal remains high for 2 seconds while the development motor is on(copyir.com )    • Drive mechanism overloaded due to toner clumping in the wasted toner path
• Motor driver board defective
490    Main fan error
The main fan motor lock signal goes high for 5 s while the fan is on(copyir.com )    • Fan motor overloaded due to obstruction
• Fan connector disconnected
495    Toner recycling unit error
Encoder pulse does not change for 3 s after the main motor switches on(copyir.com )    • Waste toner transport has stopped due to motor overload
• Toner end sensor detective, disconnected
496    Toner collection bottle errorThe toner collection bottle set switch remains off when the front door is closed(copyir.com )    • No toner collection bottle set
• Poor connection of the switch connector
497    Toner collection motor error
The toner collection motor connector set signal remains off for 1 s(copyir.com )    • Toner pump motor defective
• Motor connector loose, disconnected
501    Tray 1 lift malfunction
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(copyir.com )
• When the tray lowers, the tray lift sensor does not go off within 1(copyir.com )5 sec(copyir.com )
• Tray overload detected when the tray is set(copyir.com )
• The lower limit sensor of the LCT does not detect the lower limit within 10 sec(copyir.com )    • Tray lift motor defective, disconnected
• Paper or other obstacle trapped between tray and motor
• Pick-up solenoid disconnected, blocked by an obstacle
• Too much paper loaded in tray Note (B246)
• At first, the machine displays a message asking the operator to reset the tray(copyir.com )
• This SC will not display until the operator has pulled the tray out and pushed it in 3 times(copyir.com )
• If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(copyir.com )
502    Tray 2 lift malfunction
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(copyir.com )
• When the tray lowers, the tray lift sensor does not go off within 1(copyir.com )5 sec(copyir.com )
• Tray overload detected when the tray is set(copyir.com )    • Tray lift motor defective or disconnected
• Paper or other obstacle trapped between tray and motor
• Pick-up solenoid disconnected or blocked by an obstacle
• Too much paper loaded in tray Note (B246)
• At first, the machine displays a message asking the operator to reset the tray(copyir.com )
• This SC will not display until the operator has pulled the tray out and pushed it in 3 times(copyir.com )
• If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(copyir.com )
503    Tray 3 lift malfunction
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(copyir.com )
• When the tray lowers, the tray lift sensor does not go off within 1(copyir.com )5 sec(copyir.com )
• Tray overload detected when the tray is set(copyir.com )    • Tray lift motor defective or disconnected
• Paper or other obstacle trapped between tray and motor
• Pick-up solenoid disconnected or blocked by an obstacle
• Too much paper loaded in tray Note (B246)
• At first, the machine displays a message asking the operator to reset the tray(copyir.com )
• This SC will not display until the operator has pulled the tray out and pushed it in 3 times(copyir.com )
• If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(copyir.com )
504    Tray 4 lift malfunction
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(copyir.com )
• When the tray lowers, the tray lift sensor does not go off within 1(copyir.com )5 sec(copyir.com )
• Tray overload detected when the tray is set    • Tray lift motor defective or disconnected
• Paper or other obstacle trapped between tray and motor
• Pick-up solenoid disconnected or blocked by an obstacle
• Too much paper loaded in tray Note (B246)
• At first, the machine displays a message asking the operator to reset the tray(copyir.com )
• This SC will not display until the operator has pulled the tray out and pushed it in 3 times(copyir.com )
• If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(copyir.com )
507    LCT feed motor malfunction
One of the following conditions is detected:
• The LD signal from the feed motor is detected abnormal for 50 ms after the motor switches on(copyir.com )
• At power on, the motor is detected loose or disconnected    • Feed motor defective
• Feed motor connector disconnected
• Obstacle interfering with mechanical movement of motor(copyir.com )
510    LCT tray malfunction
One of the following conditions is detected:
• When the bottom plate is lifted, the upper limit sensor does not come on for 18 s(copyir.com )
• When the bottom plate is lowered, the lower limit sensor does not come on for 18 s(copyir.com )
• After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on(copyir.com )
• The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2(copyir.com )5 s, and a message prompts user to reset paper(copyir.com )    • Tray lift motor defective or connector disconnected
• Lift sensor defective or disconnected
• Pick-up solenoid defective or disconnected
• Paper end sensor defective
515    Tandem rear fence motor error
One of the conditions is detected:
• The return sensor does not switch on within 10 sec(copyir.com ) after the rear fence motor switches on(copyir.com )
• The HP sensor does not switch on 10 sec(copyir.com ) after the rear fence motor switches on(copyir.com )
• The HP sensor and return sensor switch on at the same time(copyir.com )    • Rear fence motor defective or poor connection
• Paper or other obstacle interfering with operation of the sensors
• Paper or other obstacle trapped between tray and motor
• Motor mechanical overload due to obstruction
• Return sensor or HP sensor defective or dirty Note (B246)
• This problem will not issue the SC code on the operation panel(copyir.com )
• The machine will prompt the operator to reset tray by opening and closing it(copyir.com )
• If the problem persists, the machine will display again and the tray cannot be used(copyir.com )
520    Duplex jogger motor error 1
When the jogger fence moves to the home position, the jogger HP sensor does not turn on even if the jogger fence motor has moved the jogger fence 153(copyir.com )5 mm    • Paper or other obstacle has jammed mechanism
• Sensor connector disconnected or defective
• Sensor defective
521    Duplex jogger motor error 2
When the jogger fence moves from the home position, the jogger fence HP sensor does not turn off even if the jogger motor has moved the jogger fence 153(copyir.com )5 mm(copyir.com )    • Paper or other obstacle has jammed mechanism
• Sensor connector disconnected or defective
• Sensor defective
531    Fusing exit motor error
The PLL lock signal was low for 2 seconds during motor operation(copyir.com )    • Motor lock caused by physical overload
• Motor drive PCB defective
541    Fusing thermistor open
The fusing temperature detected by the center thermistor was below 0°C for 7 sec(copyir.com )    • Thermistor open
• Thermistor connector defective
• Thermistor damaged, or out of position
• Fusing temperature –15% less than the standard input voltage
542    Fusing temperature warm-up error
One of the following occurred:
• After power on, or after closing the front door, the hot roller does not reach the 100°C control temperature within 25 s(copyir.com )
• 5 sec(copyir.com ) after temperature rise started, temperature remained below 21°C after 5 samplings(copyir.com )
• Fusing unit did not attain reload temperature within 48 sec(copyir.com ) of the start of fusing temperature control(copyir.com )    • Fusing lamp disconnected
• Thermistor warped, out of position
• Thermostat not operating
543    Fusing lamp overheat error 1 (software)
Central thermistor detected a temperature of 240°C at the center of the hot roller(copyir.com ) Fusing temperature control software error    • PSU defective
• IOB defective
• BICU defective
544    Fusing lamp overheat error 1 (hardware)
The central thermistor or an end thermistor detected a temperature of 250°C on the hot roller(copyir.com )    • PSU defective
• IOB defective
• BICU defective
545    Fusing lamp overheat error 2
After hot roller reaches warmup temperature, the fusing lamps remained on at full capacity for 11 samplings (1(copyir.com )8 sec(copyir.com ) duration) while the hot roller was not rotating(copyir.com )    • Thermistor damaged, or out of position
• Fusing lamp disconnected
547    Zero cross signal malfunction
One of the following conditions is detected 10 times:
• When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz(copyir.com )
• The interval between one zero cross signal and the next is 7(copyir.com )5 ms or shorter 3 times consecutively for 500 ms(copyir.com )    • Noise on the ac power line
550    Fusing Web End
Web end detected 5 times within 500 ms and web motor continues to rotate 40 s(copyir.com ) If web end is detected for another 500 ms, then the SC is logged(copyir.com )    • Web end (requires replacement)
• Web end sensor defective Note: After replacing the web with a new one, reset SP1902 001 to “0” to release SC550(copyir.com )
551    Fusing thermistor error 1
The end thermistor (contact type) was less than 0C (32F) for more than 7 seconds(copyir.com )    • Thermistor disconnected
• Thermistor connector defective
552    Fusing thermistor error 2
The end thermistor (contact type) could not detect:
• 100°C 25 seconds after the start of the warmup cycle(copyir.com )
• A change in temperature more than than 16 degrees for 5 seconds(copyir.com )
• The reload temperature with 56 seconds after the start of the fusing temperature control cycle(copyir.com )    • Fusing lamp disconnected
• Thermistor bent, damaged
• Thermistor position incorrect
553    Fusing thermistor error 3
The end thermistor (contact type) was at 240°C (464°F) for more than 1 second(copyir.com ) The temperature is read 10 times every sec(copyir.com ) (at 0(copyir.com )1 sec(copyir.com ) intervals)(copyir.com )    • PSU defective
• IOB control board defective
• BICU control board defective
555    Fusing lamp error
After the start of the warmup cycle, a fusing lamp was at full power for 1(copyir.com )8 seconds but the hot roller did not turn(copyir.com )    • Thermistor bent, out of position
• Fusing lamp disconnected
• Circuit breaker opened
557    Zero cross signal error
High frequency noise was detected on the power line(copyir.com )    • No action required(copyir.com ) The SC code is logged and the operation of the machine is not affected(copyir.com )
559    Fusing jam: 3 counts
At the fusing exit sensor the paper was detected late for three pulse counts (lag error), and SP1159 was on(copyir.com )    This SC only occurs if SP1159 is on, and a jam occurred in the fusing unit for three consecutive sheets of paper(copyir.com ) Remove the paper that is jammed in the fusing unit(copyir.com ) Then make sure that the fusing unit is clean and has no obstacles in the paper feed path(copyir.com )
569    Fusing pressure release motor error
During copying, the HP sensor could not detect the actuator, tried again 3 times and could not detect(copyir.com )    • Motor lock because of too much load
• Motor driver defective
• HP sensor defective, disconnected, connector defective, harness damaged
590    Toner collection motor error
The toner collection motor sensor output does not change for 3 seconds while the toner collection motor is on(copyir.com )    • Motor lock due to obstruction
• Motor driver board defective
• Motor connection loose, defective
• Toner collection motor sensor disconnected, sensor defective
• Rotational transmission shaft (o6 x 30) missing
599    1-bin Exit Motor Error (Japan Only)
The transport lock sensor output does not change within 300 ms after the motor switches on(copyir.com )    • Motor overload
• Motor driver defective
610    BICU – ADF communication/timeout abnormal
After 1 data frame is sent to the ADF, an ACK signal is not received within 100 ms, and is not received after 3 retries(copyir.com )    • Serial line connection unstable
• External noise on the line
611    BICU – ADF communication/break reception abnormal
During communication a break (Low) signal was received from the ADF(copyir.com )    • Serial line connection unstable
• Harness disconnected or defective
612    BICU – ADF communication/command abnormal
A command that cannot be executed was sent from the main machine to the ADF(copyir.com )    • A software error, result of an abnormal procedure(copyir.com )
620    BICU – ADF communication/timeout error
After 1 data frame is sent to the finisher MBX, an ACK signal is not received within 100 ms, and is not received after 3 retries(copyir.com )    • Serial line connection unstable
• External noise on the line
621    BICU – Finisher communication/break error
During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher(copyir.com )    • Serial line connection unstable
• External noise on the line
623    BICU – Tray 1~4 communication/timeout error
After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries(copyir.com )    • Serial line connection unstable
• External noise on the line
624    BICU – Tray 1~4 communication/break reception error
During communication with the finisher trays, the BICU received a break (Low) signal(copyir.com )    • Serial line connection unstable
• External noise on the line
626    BICU – LCT communication/timeout error
After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries(copyir.com )    • Serial line connection unstable
• External noise on the line
627    BICU – LCT communication/break reception error
During communication with the LCT, the BICU received a break (Low) signal(copyir.com )    • Serial line connection unstable
• External noise on the line
650    NRS Modem Communication Error
One of the following factors could be the cause of this error:
• In the User Tools, check the settings for the dial-up user name and dial up password(copyir.com )
• Modem has been disconnected(copyir.com )
• Modem board disconnected    Check the following for a machine that is using Cumin (NRS modem):
• An error was returned during the dialup connection
• A network was detected at startup
• At startup the machine detected that the NIB was disabled, or did not detect a modem board
651    Illegal Remote Service Dial-up
An expected error occurred when Cumin-M dialed up the NRS Center    • Software bug
• No action is required because only the count is logged
670    Engine startup error
The machine engine, controlled by the BICU (Base Image Control Unit), was operating incorrectly when the machine was switched on or returned to normal operation from the energy save mode(copyir.com )    • Check the connections between BICU and controller
• BICU defective
• Controller board defective
• PSU defective
672    Controller startup error
• After power on, the line between the controller and the operation panel did not open for normal operation(copyir.com )
• After normal startup, communication with the controller stopped(copyir.com )    • Controller stalled
• Controller installed incorrectly
• Controller board defective
• Operation panel harness disconnected or defective
700    ADF original pick-up error 1
Pick-up roller HP sensor signal does not change after the pick-up motor has turned on(copyir.com )    • Pick-up roller HP sensor defective
• Pick-up motor defective
• Timing belt slipping, out of position
• ADF main board defective
701    ADF bottom plate motor error
• Bottom plate position sensor does not detect the plate after the bottom plate lift motor switches on to lift the plate(copyir.com )
• Bottom plate HP sensor does not detect the plate after the bottom plate motor reverses to lower the plate(copyir.com )    • Bottom plate position sensor defective
• Bottom plate HP sensor defective
• Bottom plate motor defective
• ADF main board defective
720    Finisher transport motor error
The encoder pulse of the finisher transport motor does not change state (high/low) within 600 ms and does not change after 2 retries(copyir.com )    • Finisher transport motor defective
• Transport motor harness disconnected, or defective
• Finisher main board defective
721    Finisher jogger motor error
• The finisher jogger HP sensor remains de-activated for more 1,000 pulses when returning to home position(copyir.com )
• The finisher jogger HP sensor remains activated for more than 1,000 pulses when moving away from home position    • Jogger HP sensor defective
• Jogger mechanism overload
• Jogger motor defective (not rotating)
• Finisher main board defective
• Harness disconnected or defective
723    Feed-Out Belt Motor (B478)
The pawl of the feed-out belt did not return to the home position during the prescribed time after 2 attempts to detect    • Stack feed-out belt HP sensor loose, broken, defective
• Feed-out belt motor defective
• Finisher control board defective
724    Finisher staple hammer motor error (B478)
The staple hammer motor did not return to the home position within the prescribed time (340 ms)(copyir.com )    • Staple hammer HP sensor loose, broken, defective
• Electrical overload on the stapler drive PCB elect
• Staple hammer motor defective
• Finisher main board defective
725    Finisher stack feed-out motor error B140
The stack feed-out belt HP sensor does not activate within the prescribed number of pulses after the stack feed-out motor turns on and does not activate after 2 retries(copyir.com )    • Stack feed-out HP sensor defective
• Harness disconnected or defective
• Stack feed-out motor defective
• Finisher main board defective
• Motor overload
725    Exit guide motor B246
The status of the exit guide sensor did not change at the prescribed time during operation of the exit guide(copyir.com )    • Exit guide open sensor loose, broken, defective(copyir.com )
• Exit guide motor defective
• Finisher main board defective
726    Finisher upper tray lift motor error B140
The paper height sensor does not activate within the prescribed time after the upper tray lift motor turns on, or the sensor remains on after the motor reverses to lower the tray(copyir.com )    • Upper tray paper height sensor defective
• Sensor harness disconnected, defective
• Tray lift motor defective
• Finisher main board defective
• Tray lift motor overload
726    Front shift jogger motor error (B703) B246
The sides fences do not retract within the prescribed time after the shift jogger motor switches on(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Shift jogger motor disconnected, defective
• Shift jogger motor overloaded due to obstruction
• Shift jogger HP sensor disconnected, defective
727    Finisher stapler rotation motor error B140
The stapler motor switches on but the motor does not return to the home position within the prescribed number of pulses(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )    • Stapler rotation motor defective
• Poor stapler rotation motor connection
• Stapler rotation sensor defective
• Finisher main board defective
• Rotation motor overload
727    Rear shift jogger motor (B703) B246
The side fences do not retract within the prescribed time after the shift jogger motor switches on(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Motor harness disconnected, loose, defective
• Motor defective
• Motor overload
• HP defective
728    Shift jogger retraction motor error (B703) B246
The side fences do not retract within the prescribed time after the retraction motor switches on(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Motor harness disconnected, loose, defective
• Motor defective
• Motor overload
• HP defective
729    Finisher punch motor error
The punch HP sensor does not activate within the prescribed time after the punch motor turns on(copyir.com )    • Punch HP sensor defective
• Sensor harness disconnected, defective
• Punch motor defective
• Finisher main board defective
• Poor punch motor overload
730    Finisher stapler movement motor error B140
The stapler HP sensor does activate within the prescribed time after the stapler motor turns on and moves the stapler away from home position(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )    • Stapler HP sensor defective
• Sensor harness disconnected, defective
• Stapler movement motor defective
• Finisher main board defective
• Stapler movement motor overload
730    Finisher Tray 1 shift motor error B246
The shift roller HP sensor of the upper tray does not activate within the prescribed time after the shift tray starts to move toward or away from the home position(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code    • Shift tray HP sensor of the upper tray disconnected, defective
• Shift tray motor of the upper tray is disconnected, defective
• Shift tray motor of the upper tray overloaded due to obstruction
732    Finisher shift roller motor error
The shift roller HP sensor does not activate within the prescribed time after the shift roller motor turns on(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )    • Shift roller HP sensor defective
• Sensor harness disconnected, defective
• Shift roller motor defective
• Finisher main board defective
• Shift roller motor overload
733    Finisher lower tray lift motor error
After the lift motor switches on to lift the tray, paper height sensor 2 does not detect the top of the paper stack, or after the motor reverses to lower the stack the top of the stack remains detected (the status of paper height sensor 1 does not change)(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )    • Paper height sensor 1 or 2 defective
• Sensor harness disconnected, defective
• Tray lift motor defective
• Finisher main board defective
• Tray lift motor overload
735    Finisher pre-stack motor error
• The pre-stack motor starts but does not return to the home position within 400 pulses(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )
• Motor does not return to the home position within 280 pulses immediately before or after prestacking(copyir.com ) After 2 counts, the SC is logged as a jam(copyir.com )    • Jogger HP sensor defective
• Sensor harnesses disconnected, defective
• Pre-stack motor defective
• Finisher main board defective
• Pre-stack motor overload
736    Finisher paper exit guide plate motor error
The paper exit guide plate motor starts but the paper exit guide plate HP sensor does not activate within 750 ms(copyir.com ) After 2 counts, the SC is logged as a jam    • Guide plate HP sensor defective
• Sensor harness disconnected, defective
• Paper exit guide plate motor defective
• Finisher main board defective
• Guide plate motor overload
737    Trimmed staple waste hopper full
The hopper that holds the waste from staple trimming is full(copyir.com )    • Staple waste hopper full
• Staple waste sensor defective
738    Finisher pressure plate motor error
The pressure plate motor switches on but does not return to the home position within the prescribed time after 2 counts    • HP sensor defective
• Harness disconnected, defective
• Motor defective
• Finisher main board defective
• Motor overload
739    Finisher folder plate motor error
The folder plate motor turns on but the plate does not return to the home position within the prescribed time for 2 counts    • Plate HP sensor defective
• Harness disconnected, defective
• Folder plate motor defective
• Finisher main board defective
• Folder plate motor overload
740    Finisher front saddle-stitch stapler motor error B140
Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts(copyir.com )(copyir.com )    • HP sensor defective
• Harness disconnected, defective
• Stapler motor defective
• Finisher main board defective
• Stapler motor overload
740    Finisher corner stapler motor error B246
The stapler motor does not switch off within the prescribed time after operating(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Staple jam
• Number of sheets in the stack exceeds the limit for stapling
• Stapler motor disconnected, defective
741    Finisher rear saddle-stitch stapler motor error B140
Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts(copyir.com )(copyir.com )    • HP sensor defective
• Harness disconnected, defective
• Stapler motor defective
• Finisher main board defective
• Stapler motor overload
741    Finisher corner stapler rotation motor error B246
The stapler does not return to its home position within the specified time after stapling(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Stapler rotation motor disconnected, defective
• Stapler rotation motor overloaded due to obstruction
• Stapler rotation HP sensor disconnected, defective
742    Finisher jogger side fence motor error B140
The jogger motor turns on but the side fences to not return to the home position within 340 pulses for 2 counts(copyir.com )    • HP sensors defective
• Harness disconnected, defective
• Motor defective
• Finisher main board defective
• Motor overload
762    Finisher pressure plate motor error
Pressure plate motor operating but the plate is not detected at the home position within the specified time(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Pressure plate HP sensor disconnected, defective
• Pressure plate motor disconnected, defective
• Pressure plate motor overloaded due to obstruction
763    Punch movement motor error
Occurs during operation of the punch unit(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code    • Motor harness disconnected, loose, defective
• Motor defective
764    Paper position sensor slide motor error
Occurs during operation of the punch unit(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Motor harness disconnected, loose, defective
• Motor defective
765    Folding unit bottom fence lift motor
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code    • Motor harness disconnected, loose, defective
• Motor defective
766    Clamp roller retraction motor error
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code    • Motor harness disconnected, loose, defective
• Motor defective
767    Stack junction gate motor error
Occurs during operation of the punch unit(copyir.com ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(copyir.com )    • Motor harness disconnected, loose, defective
• Motor overload
• Motor defective
770    Cover interposer tray bottom plate motor error
• After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s)(copyir.com )
• After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate    • Bottom plate position sensor, disconnected, defective
• Bottom plate HP sensor disconnected, defective
780    Z-Fold feed motor error
The feed motor does not attain the prescribed speed within the specified time(copyir.com )    • Feed motor disconnected, defective
• Feed motor overloaded due to obstruction
• Feed motor lock
781    Z-Fold lower stopper motor
The lower stopper motor does not attain the prescribed speed within the specified time(copyir.com )    • Lower stopper motor disconnected, defective
• Lower stopper motor overloaded due to obstruction
• Lower stopper HP sensor disconnected, defec
782    Z-Fold upper stopper motor
The upper stopper was not detected at the home position after the motor remained on long enough to move it 128(copyir.com )7 mm(copyir.com )    • Upper stopper motor disconnected, defective
• Upper stopper motor overloaded due to obstruction
• Upper stopper HP sensor disconnected, defective
784    Z-fold timing unit fold timing sensor adjustment error
The A/D (Digital/Analog) input value did not change even after the D/A (Digital/Analog) output value changed(copyir.com )    • Fold timing sensor connector loose, broken, defective
• Fold timing sensor defective
• Fold timing sensor, mylar covered with paper dust
• Mylar disconnected
785    Z-fold leading edge sensor adjustment error
The A/D input value did not change even after the D/A output value changed    • Leading edge sensor connector loose, broken, defective
• Leading edge sensor defective
• Leading edge sensor, mylar covered with paper dust
• Mylar disconnected
786    Z-fold EEPROM error
The write operation to the Z-folding EEPROM failed after 2 attempts    • EEPROM defective
790    Finisher staple trimming hopper full
The staple waste hopper is full of cut staples    • If the hopper is full, empty the hopper
• If the hopper is not full, the hopper full sensor is disconnected, defective
817    Monitor Error
This is a file detection and electronic file signature check error when the boot loader attempts to read the selfdiagnostic module, system kernel, or root system files from the OS Flash ROM, or the items on the SD card in the controller slot are false or corrupted(copyir.com )    • OS Flash ROM data defective; change the controller firmware
• SD card data defective; use another SD card
818    Watchdog error
While the system program is running, a bus hold or interrupt program goes into an endless loop, preventing any other programs from executing(copyir.com )    • System program defective; switch off/on, or change the controller firmware if the problem cannot be solved
• Controller board defective
• Controller option malfunction
819    Fatal kernel error
Due to a control error, a RAM overflow occurred during system processing(copyir.com ) One of the following messages was displayed on the operation panel(copyir.com )    • System program defective
• Controller board defective
• Optional board defective
• Replace controller firmware
821    Self-diagnostic error 2: ASIC
The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate(copyir.com )
822    Self-diagnostic error 3: HDD
824    Self-diagnostic error 4: NVRAM
NVRAM device does not exist, NVRAM device is damaged, NVRAM socket damaged    • NVRAM defective
• Controller board defective
• NVRAM backup battery exhausted
• NVRAM socket damaged
826    Self-diagnostic error 6: NVRAM (option NVRAM)
828    Self-diagnostic error 7: ROM
• Measuring the CRC for the boot monitor and operating system program results in an error(copyir.com )
• A check of the CRC value for ROMFS of the entire ROM area results in an error    • Software defective
• Controller board defective
• ROM defective
833    Self-diagnostic error 8: Engine I/F ASIC
834    Self-diagnostic error 9: Optional Memory RAM DIMM
850    Net I/F error
• Duplicate IP addresses(copyir.com )
• Illegal IP address(copyir.com )
• Driver unstable and cannot be used on the network(copyir.com )    • IP address setting incorrect
• NIB (PHY) board defective
• Controller board defective
851    IEEE 1394 I/F error
Driver setting incorrect and cannot be used by the 1394 I/F(copyir.com )    • NIB (PHY), LINK module defective; change the Interface Board
• Controller board defective
853    Wireless LAN Error 1
During machine start-up, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802(copyir.com )11b or Bluetooth)(copyir.com )    • Wireless LAN card missing (was removed)
854    Wireless LAN Error 2
During machine operation, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802(copyir.com )11b or Bluetooth)(copyir.com )    • Wireless LAN card missing (was removed)
855    Wireless LAN error 3
An error was detected on the wireless LAN card (802(copyir.com )11b or Bluetooth)(copyir.com )    • Wireless LAN card defective
• Wireless LAN card connection incorrect
856    Wireless LAN error 4
An error was detected on the wireless LAN card (802(copyir.com )11b or Bluetooth)(copyir.com )    • Wireless LAN card defective
• PCI connector (to the mother board) loose
857    USB I/F Error
The USB driver is not stable and caused an error(copyir.com )    • Bad USB card connection
• Replace the controller board
860    HDD startup error at main power on
• HDD is connected but a driver error is detected(copyir.com )
• The driver does not respond with the status of the HDD within 30 s(copyir.com )    • HDD is not initialized
• Level data is corrupted
• HDD is defective
861    HDD re-try failure
At power on with the HDD detected, power supply to the HDD is interrupted, after the HDD is awakened from the sleep mode, the HDD is not ready within 30 s(copyir.com )    • Harness between HDD and board disconnected, defective
• HDD power connector disconnected
• HDD defective
• Controller board defective
863    HDD data read failure
The data written to the HDD cannot be read normally, due to bad sectors generated during operation    • HDD defective
Note: If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM, and the next time the HDD is accessed, these bad sectors will not be accessed for read/write operation(copyir.com )
864    HDD data CRC error
During HDD operation, the HDD cannot respond to an CRC error query(copyir.com ) Data transfer did not execute normally while data was being written to the HDD(copyir.com )    • HDD defective
865    HDD access error
HDD responded to an error during operation for a condition other than those for SC863, 864(copyir.com )    • HDD defective
866    SC card error 1: Confirmation
The machine detects an electronic license error in the application on the SD card in the controller slot immediately after the machine is turned on(copyir.com ) The program on the SD card contains electronic confirmation license data(copyir.com ) If the program does not contain this license data, or if the result of the check shows that the license data in the program on the SD card is incorrect, then the checked program cannot execute and this SC code is displayed(copyir.com )    • Program missing from the SD card
• Download the correct program for the machine to the SD card
867    SD card error 2: SD card removed
The SD card in the boot slot when the machine was turned on was removed while the machine was on(copyir.com )    • Insert the SD card, then turn the machine off and on(copyir.com )
868    SD card error 3: SC card access
An error occurred while an SD card was used(copyir.com )    • SD card not inserted correctly
• SD card defective
• Controller board defective
Note: If you want to try to reformat the SC card, use SD Formatter Ver 1(copyir.com )1
870    Address book data error
Address book data on the hard disk was detected as abnormal when it was accessed from either the operation panel or the network(copyir.com ) The address book data cannot be read from the HDD or SD card where it is stored, or the data read from the media is defective(copyir.com )    • Software defective(copyir.com ) Turn the machine off/on(copyir.com ) If this is not the solution for the problem, then replace the controller firmware(copyir.com )
• HDD defective(copyir.com )
873    HDD mail send data error
An error was detected on the HDD immediately after the machine was turned on, or power was turned off while the machine used the HDD(copyir.com )    • Do SP5832-007 (Format HDD – Mail TX Data) to initialize the HDD(copyir.com )
• Replace the HDD
874    Delete All error 1: HDD
A data error was detected for the HDD/NVRAM after the Delete All option was used(copyir.com ) Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card(copyir.com )    • Turn the main switch off/on and try the operation again(copyir.com )
• Install the Data Overwrite Security Unit again(copyir.com ) For more, see section “1(copyir.com ) Installation”(copyir.com )
• HDD defective
875    Delete All error 2: Data area
An error occurred while the machine deleted data from the HDD(copyir.com ) Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card(copyir.com )    • Turn the main switch off/on and try the operation again(copyir.com )
880    File Format Converter (MLB) error
A request to get access to the MLB was not answered within the specified time(copyir.com )    • MLB defective, replace the MLB
900    Electrical total counter error
The total counter contains something that is not a number(copyir.com )    • NVRAM incorrect type
• NVRAM defective
• NVRAM data scrambled
• Unexpected error from external source
901    Mechanical total counter error
The mechanical counter is not connected(copyir.com )    • Mechanical total counter defective
• Mechanical total counter connector not connected
910 (copyir.com )(copyir.com )(copyir.com ) 914    External Controller Error
The external controller alerted the machine about an error(copyir.com )    • Please refer to the instructions for the external controller(copyir.com )
919    External Controller Error 6
While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected(copyir.com )    • Power outage at the EFI controller
• EFI controller was rebooted
• Connection to EFI controller loo
920    Printer error 1
An internal application error was detected and operation cannot continue(copyir.com )    • Software defective; turn the machine off/on, or change the controller firmware
• Insufficient memory
921    Printer error 2
When the application started, the necessary font was not on the SD card(copyir.com )    • Font not on the SC card
925    NetFile Function Error
• The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue(copyir.com )
• The HDDs are defective and they cannot be debugged or partitioned, so the Scan Router functions (delivery of received faxes, document capture, etc(copyir.com )), Fabric services, and other network functions cannot be used(copyir.com )( HDD status codes displayed on the debug console are described below(copyir.com ))    • HDD defective
• Power supply to machine cut occurred while writing data to HDD
• Software error
• Please refer to the detailed descriptions below for recovery procedures(copyir.com )
953    Scanner image setting error
The settings required for image processing using the scanner are not sent from the IPU(copyir.com )    • Software defective
954    Printer image setting error
The settings required for image processing using the printer controller are not sent from the IPU(copyir.com )    • Software defective
955    Memory setting error
The settings that are required for image processing using the memory are not sent from the IPU(copyir.com )    • Software defective
964    Printer ready error
The print ready signal is not generated for more than 17 seconds after the IPU received the print start signal(copyir.com )    • Software defective
984    Print image data transfer error
After a data transfer begins from the controller to the engine via the PCI bus, the transfer does not end within 15 s(copyir.com )    • Controller (SIMAC) board defective
• BICU defective
• BICU – controller disconnected
985    Scanned image data transmission error
After a data transfer begins from the engine to the controller via the PCI bus, the transfer does not end within 3 s(copyir.com )    • Controller (SIMAC) board defective
• BICU defective
• BICU – controller disconnected
986    Software error 1
The write parameter received by the write module at the beginning of the setting table is NULL    • Controller (SIMAC) board defective
• BICU defective
• BICU – controller disconnected
990    Software error 2
The software performs an unexpected function and the program cannot continue(copyir.com )    • Software defective, re-boot
991    Software error 3
The software performs an unexpected function and the program cannot continue(copyir.com ) However, unlike SC990, recovery processing allows the program to continue(copyir.com )    Software defective, re-boot
992    Software error 4: Undefined
An error not controlled by the system occurred (the error does not come under any other SC code)(copyir.com )    • Software defective
• Turn the machine power off and on(copyir.com ) The machine cannot be used until this error is cleared(copyir.com )
994    Operation Panel Management Records Exceeded
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware(copyir.com ) This can occur if there if there are too many application screens open on the operation panel(copyir.com )    • No action required because this SC does not interfere with operation of the machine
997    Cannot select application function
An application does not start after the user pushed the correct key on the operation panel(copyir.com )    • Software bug
• A RAM or DIMM option necessary for the application is not installed or not installed correctly(copyir.com )
998    Application cannot start
Register processing does not operate for an application within 60 s after the machine power is turned on(copyir.com ) No applications not start correctly, and all end abnormally(copyir.com )    • Software bug
• A RAM or DIMM option necessary for the application is not installed or not installed correctly

 

 

 

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید