ریکو آفشیو Ricoh Aficio 1013
E000-0001 Insufficient temperature rise of fixing unit when power is turned ON
When the temperature of the fixing belt main thermistor failed to reach 50 deg C within 120 seccopyir ( copyir.com ) com after the fixing belt temperature regulation has started Check for broken or disconnected heater wirescopyir ( copyir.com ) com Checking Disconnection of the Connector in the Thermistor Wiringcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixercopyir ( copyir.com ) com Replace the IH power supply PCB and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E000-0101 Insufficient temperature rise of fixing unit when power is turned ON
When the temperature of the pressure belt main thermistor failed to reach 50 deg C within 120 seccopyir ( copyir.com ) com after the pressure belt temperature regulation has started Check for broken or disconnected heater wirescopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com Checking Disconnection of the Connector in the Thermistor Wiringcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0001 Abnormally high temperature rise of fixing unit (circuit trouble)
When the fixing belt main thermistor has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0002 Abnormally high temperature rise of fixing unit (circuit trouble)
When fixing sub-thermistor 1 has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0003 Abnormally high temperature rise of fixing unit (circuit trouble)
When fixing sub-thermistor 2 has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0101 Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure main thermistor has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0102 Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure sub-thermistor 1 has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E001-0103 Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure sub-thermistor 2 has detected a high temperature (ASIC detection) Check the connection of the connector in the thermistor wiring (wirepinching, disconnection)copyir ( copyir.com ) com Replace the fixing unitcopyir ( copyir.com ) com Replace the IH unit, halogen heater, fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0002 Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0003 Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 110 deg C within the prescribed period of time after reaching 80 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0004 Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 130 deg C within the prescribed period of time after reaching 110 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0005 Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 150 deg C within the prescribed period of time after reaching 130 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0006 Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 170 deg C within the prescribed period of time after reaching 150 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0101 Insufficient temperature rise of fixing unit
When the pressure main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E002-0102 Insufficient temperature rise of fixing unit
When the pressure main thermistor fails to reach 100 deg C within the prescribed period of time after reaching 80 deg C during warm-up Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E003-0001 Fixing unit low temperature trouble
When the fixing main thermistor has detected a temperature below 130 deg C for the prescribed period of time after standby Checking Disconnection of the Connector in the Thermistor Wiringcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
E003-0002 Fixing unit low temperature trouble
When the pressure main thermistor has detected a temperature below 50 deg C for the prescribed period of time after standby Checking Disconnection of the Connector in the Thermistor Wiringcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com Replace the fixer and AC driver PCBcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
E004-0101 Fixing unit protection circuit trouble
When there is a short-circuit detection error in the halogen heater (ASIC detection) Check the connection of the J114 jack of the AC driver PCB, and replace the AC driver PCB (triac short)copyir ( copyir.com ) com Replace the Pressure heatercopyir ( copyir.com ) com Replace the Fixing unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0201 Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0201 Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0202 Fixing unit protection circuit trouble
When the difference in temperature between the center and front of the fixing belt is higher than the rating Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0203 Fixing unit protection circuit trouble
When the difference in temperature between the center and back of the fixing belt is higher than the rating Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0204 Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the pressure belt is higher than the rating Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0205 Fixing unit protection circuit trouble
Thermistor temperature difference error (combination unknown) Replace the fixing belt unitcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E004-0301 Fixing unit protection circuit trouble
When an overcurrent has been detected in the IH power supply PCB Replace the IH power supply PCBcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com
E004-0401 Fixing unit protection circuit trouble
13 V trouble error Check the connection of the connectors of the relay PCB, the IH power supply, the fixing thermoswitch, and replace the fixing unit (fixing thermoswitch OFF), the relay PCB, and the IH power PCB (blowout of the FU261)copyir ( copyir.com ) com In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E004-0501 Fixing unit protection circuit trouble
Fixing main thermistor or fixing sub-thermistor 1 or 2 connection error Check the connections of the fixing belt unit connectorscopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com
E004-0502 Fixing unit protection circuit trouble
Pressure main thermistor or pressure sub-thermistor 1 or 2 connection error Check the connections of the pressure belt unit connectorscopyir ( copyir.com ) com Replace the pressure belt unitcopyir ( copyir.com ) com
E004-0601 Fixing unit protection circuit trouble
IH power supply ID error Check the connection of the connectors of the IH power supply PCB J1009, the DC controller PCB 2 (MAISY) J109, and the relay PCB connectorcopyir ( copyir.com ) com In the case of not being locked after turning ON the motor
E004-0701 Fixing unit protection circuit trouble
Relay OFF status error Replace the relay PCBcopyir ( copyir.com ) com
E007-0001 Fixing belt or pressure belt deviation trouble
Fixing belt deviation trouble (trouble in top belt displacement or in belt deviation sensor) Replace the fixing unitcopyir ( copyir.com ) com
E007-0002 Fixing belt or pressure belt deviation trouble
Pressure belt deviation trouble (trouble in bottom belt push-off or in belt deviation sensor) Replace the fixing unitcopyir ( copyir.com ) com
E007-0101 Fixing belt or pressure belt deviation trouble
Fixing belt home position detection error Replace the fixing belt HP sensorcopyir ( copyir.com ) com Replace the fixing deviation control motor, DC controller PCB 2 (MAISY) and fixing unitcopyir ( copyir.com ) com
E007-0102 Fixing belt or pressure belt deviation trouble
Pressure belt home position detection error Replace the pressure belt HP sensorcopyir ( copyir.com ) com Replace the pressure deviation control motor, DC controller PCB 2 (MAISY) and fixing unitcopyir ( copyir.com ) com
E007-0201 Fixing belt or pressure belt deviation trouble
Belt push-off temporary escape mode error Occurs when the belt deviation is not eliminated within 1 minute in the belt push-off temporary escape modecopyir ( copyir.com ) com
E007-9991 Fixing belt or pressure belt deviation trouble
Top belt deviation control timeout error Occurs when operation was not performed normally when COPIER > FUNCTION > FIXING > FX-UHP-S was executedcopyir ( copyir.com ) com
E007-9992 Fixing belt or pressure belt deviation trouble
Bottom belt deviation control timeout error Occurs when operation was not performed normally when COPIER > FUNCTION > FIXING > FX-LHP-S was executedcopyir ( copyir.com ) com
E008-0001 Fixing unit end-of-life detection error
Fixing unit end-of-life detection error Occurs when the fixing unit end-of-life is detected or when the belt pushoff temporary escape mode was executed but normal operation was not restoredcopyir ( copyir.com ) com
E009-0500 Pressure belt pressure release error
Pressure belt unit pressure release HP search error Replace the fixing pressure release HP sensorcopyir ( copyir.com ) com Replace the fixing pressure motorcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E009-0501 Pressure belt pressure release error
Pressure belt unit pressure release timeout error Replace the fixing pressure release HP sensorcopyir ( copyir.com ) com Replace the fixing pressure motorcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E009-0502 Pressure belt pressure release error
Pressure belt unit pressure timeout error Replace the fixing pressure release HP sensorcopyir ( copyir.com ) com Replace the fixing pressure motorcopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com
E012-0001 Drum ITB motor trouble
Drum ITB motor fails to runcopyir ( copyir.com ) com Replace the drumITB motercopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com Replace the DCDC convertercopyir ( copyir.com ) com
E012-0002 Drum ITB motor trouble
Drum ITB motor runs but then stops runningcopyir ( copyir.com ) com Replace the drumITB motercopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com Replace the DCDC convertercopyir ( copyir.com ) com
E012-0003 Drum ITB motor trouble
When the drum ITB motor fails to stop Replace the drumITB motercopyir ( copyir.com ) com Replace the DC controller PCB 2 (MAISY)copyir ( copyir.com ) com Replace the DCDC convertercopyir ( copyir.com ) com
E014-0001 Fixing motor error
Drum Unit / Faulty Connection of the Toner Receptacle Replace the drumITB motercopyir ( copyir.com ) com Replace the fixing motercopyir ( copyir.com ) comReplace the DCDC converterAi38VAjcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com
E014-0001 Fixing motor error
Drum Unit / Faulty Connection of the Toner Receptacle Replace the drumITB motercopyir ( copyir.com ) com Replace the fixing motercopyir ( copyir.com ) comReplace the DCDC converterAi38VAjcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com
E014-0002 Fixing motor error
When the lock was disengaged after the motor was locked Replace the drumITB motercopyir ( copyir.com ) com Replace the fixing motercopyir ( copyir.com ) comReplace the DCDC converterAi38VAjcopyir ( copyir.com ) com Replace the fixing belt unitcopyir ( copyir.com ) com
E020-xx20 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
ATR sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com The drum unit is not installed properly or there is trouble in the unitcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx24 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com There is trouble in the drum unitcopyir ( copyir.com ) com Replace the SALT sensor (clean it)copyir ( copyir.com ) com Check the drum unit connectionscopyir ( copyir.com ) com Replace the drum unitcopyir ( copyir.com ) com
E020-xx25 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com There is trouble in the drum unitcopyir ( copyir.com ) com Deterioration in ITBcopyir ( copyir.com ) com Replace the SALT sensor (clean the sensor window)copyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com Replace the ITB (clean it)copyir ( copyir.com ) com
E020-xx30 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
ATR sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com Incorrect setting of ATR sensor operation valuescopyir ( copyir.com ) com The drum unit is not installed properly or there is trouble in the unitcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx34 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Sample images drawn by ATR control are not createdcopyir ( copyir.com ) com SALT sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com There is trouble in the drum unitcopyir ( copyir.com ) com Deterioration in ITBcopyir ( copyir.com ) com Replace the SALT sensor (clean the sensor window)copyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com Replace the ITB (clean it)copyir ( copyir.com ) com
E020-xx35 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wire Replace the SALT sensor (clean it)copyir ( copyir.com ) com
E020-xx40 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect setting of ATR sensor operation valuescopyir ( copyir.com ) com ATR sensor trouble or a broken/disconnected wirecopyir ( copyir.com ) com The drum unit is not installed properly (the copier cannot detect the drum unit) or there is trouble in the unitcopyir ( copyir.com ) com Replace the SALT sensor (clean it)copyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx50 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density operation value which was set when the new drum unit was installed Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx60 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low) Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx70 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low) Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xx80 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Density value is extremely high for the ITB surface reflectivity when the new drum unit was installedcopyir ( copyir.com ) com SALT sensor troublecopyir ( copyir.com ) com Replace the SALT sensor (clean the sensor window)copyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com Replace the ITB (clean it)copyir ( copyir.com ) com
E020-xx81 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Density value is extremely low for the ITB surface reflectivity when the new drum unit was installedcopyir ( copyir.com ) com SALT sensor troublecopyir ( copyir.com ) com Dirty ITBcopyir ( copyir.com ) com Replace the SALT sensor (clean the sensor window)copyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com Replace the ITB (clean it)copyir ( copyir.com ) com
E020-xx83 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Trouble in detected ITB surface reflectivity rate (value is extremely high) Replace the ITB (clean it)copyir ( copyir.com ) com
E020-xxA0 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Measured value of the detected developer density is extremely lowcopyir ( copyir.com ) com Trouble in the ATR sensorcopyir ( copyir.com ) com Trouble in the drum unitcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xxB0 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio has dropped due to the drum unit end-of-lifecopyir ( copyir.com ) com Broken or disconnected wire in the ATR sensorcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xxB2 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio is extremely high compared with when the new drum unit was installedcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xxB2 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio is extremely high compared with when the new drum unit was installedcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xxC0 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Trouble in the supply of the toner from the toner cartridge to the developercopyir ( copyir.com ) com Too much toner is supplied to the developercopyir ( copyir.com ) com Broken or disconnected wire in the ATR sensorcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E020-xxD0 Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
No toner is supplied from the toner cartridge to the developercopyir ( copyir.com ) com TCRG motor fails to runcopyir ( copyir.com ) com An empty cartridge is being usedcopyir ( copyir.com ) com The toner supply port of the drum unit is damagedcopyir ( copyir.com ) com Broken or disconnected wire in the ATR sensorcopyir ( copyir.com ) com Replace the toner cartridge motorcopyir ( copyir.com ) com Replace the drum unit (check its connections)copyir ( copyir.com ) com
E032-0001 NE controller counter operation failure
When the counter function of the NE controller does not work Check the cable connectionscopyir ( copyir.com ) com
E110-0110 Laser scanner motor running trouble
Trouble in the running of the laser scanner motor for Y Replace the laser scanner (Y) and the DC controller PCB 1 (IMG)copyir ( copyir.com ) com
E110-0210 Laser scanner motor running trouble
Trouble in the running of the laser scanner motor for M Replace the laser scanner (M) and the DC controller PCB 1 (IMG)copyir ( copyir.com ) com
E110-0310 Laser scanner motor running trouble
Trouble in the running of the laser scanner motor for C Replace the laser scanner (C) and the DC controller PCB 1 (IMG)copyir ( copyir.com ) com
E110-0410 Laser scanner motor running trouble
Trouble in the running of the laser scanner motor for Bk Replace the laser scanner (Bk) and the DC controller PCB 1 (IMG)copyir ( copyir.com ) com
E193-0001 Initializing error of the image ASIC on the DC controller PCB 2 (IMG) Replace the DC controller PCB 2 (IMG)copyir ( copyir.com ) com
E202-0001 1st mirror stand HP detection trouble
The 1st mirror stand fails to move tTransparency even when it retractscopyir ( copyir.com ) com Replace the optical system HP sensor, optical system motor and reader controller PCBcopyir ( copyir.com ) com
E202-0002 1st mirror stand HP detection trouble
The 1st mirror stand fails to move from HP even when it advancescopyir ( copyir.com ) com Replace the optical system HP sensor, optical system motor and reader controller PCBcopyir ( copyir.com ) com
E225-0001 Exposure lamp lighting trouble
Light quantity of the exposure lamp has droppedcopyir ( copyir.com ) com Clean the white platecopyir ( copyir.com ) com Replace the exposure lampcopyir ( copyir.com ) com
E227-0001 Reader unit power supply error
When the 24 V port is OFF when the power is turned ONcopyir ( copyir.com ) com Disconnect and re-connect the power connectorcopyir ( copyir.com ) com Replace the power supply
E227-0002 Reader unit power supply error
When the 24 V port is OFF when a job is startedcopyir ( copyir.com ) com Disconnect and re-connect the power connectorcopyir ( copyir.com ) com Replace the power supply
E227-0003 Reader unit power supply error
When the 24 V port is OFF when a job is finishedcopyir ( copyir.com ) com Disconnect and re-connect the power connectorcopyir ( copyir.com ) com Replace the power supply
E227-0004 Reader unit power supply error
When the 24 V port is OFF during load drivecopyir ( copyir.com ) com Disconnect and re-connect the power connectorcopyir ( copyir.com ) com Replace the power supply
E240-0000 Error in communication between main controller and DC controller
Serial communication error Check the connector connectionscopyir ( copyir.com ) com Check the DC controller PCB (MAISY)copyir ( copyir.com ) com Replace the Nocopyir ( copyir.com ) com1 main controller circuitcopyir ( copyir.com ) com
E240-0002 Error in communication between main controller and DC controllerWhen the response from the DC controller does not arrive within the prescribed period of time during printing Check the connector connectionscopyir ( copyir.com ) com Check the DC controller PCB (MAISY)copyir ( copyir.com ) com Replace the Nocopyir ( copyir.com ) com1 main controller circuitcopyir ( copyir.com ) com
E248-0001 Defective EEPROM on reader controller PCB
Error when the power of the reader controller EEPROM is turned ON Replace the reader controller PCBcopyir ( copyir.com ) com
E248-0002 Defective EEPROM on reader controller PCB
Error when data is written into the reader controller EEPROM Replace the reader controller PCBcopyir ( copyir.com ) com
E248-0003 Defective EEPROM on reader controller PCB
Reader controller EEPROM check error or error when data is read after it was written Replace the reader controller PCBcopyir ( copyir.com ) com
E315-000e Image data trouble
Damaged data (trouble in memory or HDD) Software decoding error Replace the image memory (SDRAM) or HDDcopyir ( copyir.com ) com
E351-0000 Main controller PCB error
When a communication error has occurred in the main controller PCB at startup Check the connections between the main controller PCB and main controller PCB (sub)copyir ( copyir.com ) com Replace the main controller PCBcopyir ( copyir.com ) com Replace the main controller PCB (sub)copyir ( copyir.com ) com
E400-0001 Feeder communication error
Checksum error Check the connections between the ADF controller PCB and main controller PCB (sub)copyir ( copyir.com ) com Replace the ADF controller PCBcopyir ( copyir.com ) com Replace the main controller PCB (sub)copyir ( copyir.com ) com
E400-0002 Feeder communication error
Reception status error Check the connections between the ADF controller PCB and main controller PCB (sub)copyir ( copyir.com ) com Replace the ADF controller PCBcopyir ( copyir.com ) com Replace the main controller PCB (sub)copyir ( copyir.com ) com
E400-0003 Feeder communication error
Reception interrupt error Check the connections between the ADF controller PCB and main controller PCB (sub)copyir ( copyir.com ) com Replace the ADF controller PCBcopyir ( copyir.com ) com Replace the main controller PCB (sub)copyir ( copyir.com ) com
E402 Transport motor error
The transport motor (M2) fails to runcopyir ( copyir.com ) com Defective transport motor clock sensor (SR1) When the transport motor encoder pulse is not detected even when 0copyir ( copyir.com ) com3 seccopyir ( copyir.com ) com has elapsed after the signal to drive the DF transport motor was set to ON
E413-0001 Pressure motor trouble
Pressure HP sensor OPEN Replace the pressure motorcopyir ( copyir.com ) com
E413-0002 Pressure motor trouble
Pressure HP sensor CLOSE Replace the pressure motorcopyir ( copyir.com ) com
E490-0001 Wrong model error
When the feeder of another model has been detected Connect the feeder for this unitcopyir ( copyir.com ) com
E500-0001 Finisher communication error
When trouble in the prescribed number of times or in the prescribed period of time has been detected during communication between the copier itself and finisher Check the connections between the DC controller PCB and finisher controller PCBcopyir ( copyir.com ) com Replace the finisher controller PCBcopyir ( copyir.com ) com Replace the DC controller PCBcopyir ( copyir.com ) com
E503-0002 Saddle communication error
When communication with the saddle stitcher is interrupted – Check the connections between the saddle stitcher controller PCB and finisher controller PCBcopyir ( copyir.com ) com – Replace the saddle stitcher controller PCB and finisher controller PCBcopyir ( copyir.com ) com
E505-0001 Finisher backup memory error
When the checksum value calculated by the CPU differs from the checksum values of the data held inside the RAM Replace the finisher controller PCBcopyir ( copyir.com ) com
E505-0002 Finisher backup memory error
When the verify processing is not completed even after 2000 ms have elapsed during data writing Replace the finisher controller PCBcopyir ( copyir.com ) com
E514-8001 Bundling (forward rotation direction) error
When the trailing edge fails to leave the trailing edge assist home position even when the trailing edge assist motor has been driven for 3 seccopyir ( copyir.com ) com Replace the trailing edge assist motor (M109) and trailing edge assist home position sensor (PI109)copyir ( copyir.com ) com
E514-8002 Bundling (forward rotation direction) error
When the trailing edge fails to return to the trailing edge assist home position even when the trailing edge assist motor has been driven for 3 seccopyir ( copyir.com ) com Replace the trailing edge assist motor (M109) and trailing edge assist home position sensor (PI109)copyir ( copyir.com ) com
E520-0001 Offset error
When the offset HP sensor fails to turn ON even though the offset motor was driven for 1000 ms toward the HP sensor approach side while the motor was running – Check the offset HP sensor connectorscopyir ( copyir.com ) com – Check the offset motor connectorscopyir ( copyir.com ) com – Replace the offset HP sensorcopyir ( copyir.com ) com – Replace the offset motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E520-0002 Offset error
When the offset HP sensor fails to turn OFF even though the offset motor was driven for 1000 ms toward the HP sensor escape side while the motor was running – Check the offset HP sensor connectorscopyir ( copyir.com ) com – Check the offset motor connectorscopyir ( copyir.com ) com – Replace the offset HP sensorcopyir ( copyir.com ) com – Replace the offset motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E530-8001 Alignment error
When the alignment plate fails to leave the alignment plate front home position sensor position even when the alignment plate front motor was driven for 4 seccopyir ( copyir.com ) com Replace the alignment plate front motor (M103) and alignment plate front home position sensor (PI106)copyir ( copyir.com ) com
E530-8002 Alignment error
When the alignment plate fails to return to the alignment plate front home position sensor position even when the alignment plate front motor was driven for 4 seccopyir ( copyir.com ) com Replace the alignment plate front motor (M103) and alignment plate front home position sensor (PI106)copyir ( copyir.com ) com
E531-0001 Stapler error
When the stapler unit failed to leave the stapler home position even though 400 ms elapsed since the stapler operation started – Check the stapler unit connectorscopyir ( copyir.com ) com – Replace the stapler unitcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E531-0002 Stapler error
When the stapler unit left the stapler home position but then failed to reach the stapler home position even though 400 ms elapsed since the stapler operation startedcopyir ( copyir.com ) com When the unit failed to reach the stapler home position within 400 ms even after operation in the reverse directioncopyir ( copyir.com ) com – Check the stapler unit connectorscopyir ( copyir.com ) com – Replace the stapler unitcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E531-8001 Stapler error
When the stapler fails to leave the stapler home position even though the stapler motor was driven for 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com Replace the stapler motor (M111) and stapler home position detection sensor (PI50)copyir ( copyir.com ) com
E531-8002 Stapler error
When the stapler fails to return to the stapler home position even though the stapler motor was driven for 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com Replace the stapler motor (M111) and stapler home position detection sensor (PI50)copyir ( copyir.com ) com
E535-8001 Oscillation error
When the stapler fails to leave the oscillation home position even though the oscillator motor was driven for 3 seccopyir ( copyir.com ) com Replace the oscillator motor (M106) and oscillation home position sensor (PI105)copyir ( copyir.com ) com
E535-8002 Oscillation error
Occurs when the oscillation guide close switch fails to be set to ON even when the oscillator motor is run in the reverse direction for 1 seccopyir ( copyir.com ) com Replace the oscillator motor (M106) and oscillation home position sensor (PI105)copyir ( copyir.com ) com
E537-8001 Front alignment error
When the alignment plate fails to leave the alignment plate back home position sensor position even though the alignment plate back motor was driven for 4 seccopyir ( copyir.com ) com Replace the alignment plate back motor (M104) and alignment plate back home position sensor (PI107)copyir ( copyir.com ) com
E537-8002 Front alignment error
When the alignment plate fails to return to the alignment plate back home position sensor position even though the alignment plate back motor was driven for 4 seccopyir ( copyir.com ) com Replace the alignment plate back motor (M104) and alignment plate back home position sensor (PI107)copyir ( copyir.com ) com
E540-0001 Tray up/down error
When the sheet level could not be detected even though the standard tray was operated – Check the standard tray HP sensor connectorscopyir ( copyir.com ) com – Check the standard tray clock sensor connectorscopyir ( copyir.com ) com – Check the standard tray shift motor connectorscopyir ( copyir.com ) com – Replace the standard tray HP sensorcopyir ( copyir.com ) com – Replace the standard tray clock sensorcopyir ( copyir.com ) com – Replace the standard tray shift motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E540-0003 Tray up/down error
When the sensor is not reached even after 3000 ms when the standard tray was operated – Check the standard tray HP sensor connectorscopyir ( copyir.com ) com – Check the standard tray clock sensor connectorscopyir ( copyir.com ) com – Check the standard tray shift motor connectorscopyir ( copyir.com ) com – Replace the standard tray HP sensorcopyir ( copyir.com ) com – Replace the standard tray clock sensorcopyir ( copyir.com ) com – Replace the standard tray shift motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E540-0005 Tray up/down error
When the encoder clock signal of the standard tray is not detected for 2 or more times even after 300 ms when the standard tray was operated – Check the standard tray HP sensor connectorscopyir ( copyir.com ) com – Check the standard tray clock sensor connectorscopyir ( copyir.com ) com – Check the standard tray shift motor connectorscopyir ( copyir.com ) com – Replace the standard tray HP sensorcopyir ( copyir.com ) com – Replace the standard tray clock sensorcopyir ( copyir.com ) com – Replace the standard tray shift motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E540-8001 Tray up/down error
– When the tray fails to return to the home position even when the 1st tray shift motor has been driven for 20 seccopyir ( copyir.com ) com – When the tray fails to move to another area even when the 1st tray shift motor has been driven for 4 seccopyir ( copyir.com ) com – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8002 Tray up/down error
When a danger area is reached before the sheet level is detected by the 1st tray sheet level detection sensor during the sheet level detection operation – When a discontinuous area was detected during the tray operation – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8003 Tray up/down error
When the input of the clock signal could not be detected within 0copyir ( copyir.com ) com2 seccopyir ( copyir.com ) com during the operation of the 1st tray shift motor – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8004 Tray up/down error
When the input of the clock signal could not be detected within 0copyir ( copyir.com ) com2 seccopyir ( copyir.com ) com during the operation of the 1st tray shift motor – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8005 Tray up/down error
When the lock detection signal was set to OFF 150 ms after the lock detection signal was set to ON – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8006 Tray up/down error
When the lock detection signal could not be set to ON within 1 seccopyir ( copyir.com ) com after the start of the 1st tray shift motor drive – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E540-8007 Tray up/down error
When the lock detection signal fails to go OFF when the 1st tray shift motor is stopped – Check the 1st tray shift area sensor connectorscopyir ( copyir.com ) com – Replace the 1st tray shift area sensorcopyir ( copyir.com ) com – Replace the 1st tray shift motor (M107)
E542-8001 Tray shift error
When the tray fails to return to the home position even when the 2nd tray shift motor has been driven for 20 seccopyir ( copyir.com ) com – When the tray fails to move to another area even when the 2nd tray shift motor has been driven for 4 seccopyir ( copyir.com ) com – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E542-8002 Tray shift error
– When the upper limit area is reached before the sheet level is detected by the 2nd tray sheet level detection sensor 1 during a sheet level detection operation – When a discontinuous area was detected during the tray operation – When the fact that the area ahead of the 2nd tray sheet level detection sensor 2 has been reached is detected before the sheet level is detected by the 2nd tray sheet level detection sensor 2 during an escape operation – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E542-8004 Tray shift error
When the input of the clock signal could not be detected within 0copyir ( copyir.com ) com2 seccopyir ( copyir.com ) com while the 2nd tray shift motor was running – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E542-8005 Tray shift error
When the lock detection signal was set to OFF 150 ms after the lock detection signal was set to ON – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E542-8006 Tray shift error
When the lock detection signal could not be set to ON within 1 seccopyir ( copyir.com ) com after the 2nd tray shift motor started driving – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E542-8007 Tray shift error
When the lock detection signal fails to go OFF when the 2nd tray shift motor is stopped – Check the 2nd tray shift area sensor board connectorscopyir ( copyir.com ) com – Replace the 2nd tray shift area sensor boardcopyir ( copyir.com ) com – Replace the 2nd tray shift motor (M108)copyir ( copyir.com ) com
E575-0001 When the binding motor was driven for 2000 ms in the binding direction (HP sensor approach direction) during a binding motor operation but the binding HP sensor failed to turn ON – Check the binding HP sensor connectorscopyir ( copyir.com ) com – Check the binding motor connectorscopyir ( copyir.com ) com – Check the binding HP sensor connectorscopyir ( copyir.com ) com – Replace the binding motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E575-0002 When the binding motor was driven for 2000 ms in the HP sensor escape direction during a binding motor operation but the binding HP sensor failed to turn OFF – Check the binding HP sensor connectorscopyir ( copyir.com ) com – Check the binding motor connectorscopyir ( copyir.com ) com – Check the binding HP sensor connectorscopyir ( copyir.com ) com – Replace the binding motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E584-0001 Tray unit trouble
– When the tray safety switch is actuated during a tray operation (up or down) – When the tray was operated with the finger pinching prevention switch actuated – Check the tray shift motor connectorscopyir ( copyir.com ) com – Check the tray safety switch connectorscopyir ( copyir.com ) com – Replace the tray shift motorcopyir ( copyir.com ) com – Replace the finisher controller PCBcopyir ( copyir.com ) com
E584-0002 Tray unit trouble
When the shutter fails to return to the shutter home position even when the binding motor has been driven for 3 seccopyir ( copyir.com ) com – Check the shutter home position sensor connectorscopyir ( copyir.com ) com – Replace the shutter home position sensorcopyir ( copyir.com ) com – Replace the shutter open/close clutch (CL101)copyir ( copyir.com ) com – Replace the binding bottom roller clutch (CL102)copyir ( copyir.com ) com – Replace the binding motor (M102)copyir ( copyir.com ) com
E584-8001 Tray unit trouble
When the shutter fails to leave the shutter home position even when the binding motor has been driven for 3 seccopyir ( copyir.com ) com – Check the shutter home position sensor connectorscopyir ( copyir.com ) com – Replace the shutter home position sensorcopyir ( copyir.com ) com – Replace the shutter open/close clutch (CL101)copyir ( copyir.com ) com – Replace the binding bottom roller clutch (CL102)copyir ( copyir.com ) com – Replace the binding motor (M102)copyir ( copyir.com ) com
E590-8001 When the puncher cannot detect the punch home position sensor even when the punch motor is driven for 200 ms – Check the punch home position sensor (P163) and punch motor clock sensor (P162) connectorscopyir ( copyir.com ) com – Replace the punch home position sensor (P163) and punch motor clock sensor (P162) connectorscopyir ( copyir.com ) com – Replace the punch motor (M61)copyir ( copyir.com ) com
E590-8002 When the puncher cannot detect the punch home position sensor after motor drive has stopped during the initial operation of the punch motor – Check the punch home position sensor (P163) and punch motor clock sensor (P162) connectorscopyir ( copyir.com ) com – Replace the punch home position sensor (P163) and punch motor clock sensor (P162) connectorscopyir ( copyir.com ) com – Replace the punch motor (M61)copyir ( copyir.com ) com
E591-8001 When the light sensing voltage is less than 3copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of the waste full detection sensor has been set to more than 66% – Check the waste full detection sensor (LED6, PTR6) connectorscopyir ( copyir.com ) com – Replace the waste full detection sensors (LED6, PTR6)copyir ( copyir.com ) com
E591-8002 When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of the waste full detection sensor has been set to 0% – Check the waste full detection sensor (LED6, PTR6) connectorscopyir ( copyir.com ) com – Replace the waste full detection sensors (LED6, PTR6)copyir ( copyir.com ) com
E592-8001 Sheet trailing edge, side registration sensor error
When the light sensing voltage is less than 2copyir ( copyir.com ) com5 V even though the lightemitting duty ratio of the sheet trailing edge sensor has been set to more than 66% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8002 Sheet trailing edge, side registration sensor error
When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of the sheet trailing edge sensor has been set to 0% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8003 Sheet trailing edge, side registration sensor error
When the light sensing voltage is less than 2copyir ( copyir.com ) com5 V even though the lightemitting duty ratio of side registration sensor 1 (LED1, PTR1) has been set to more than 66% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8004 Sheet trailing edge, side registration sensor error
When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of side registration sensor 1 (LED1, PTR1) has been set to 0% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8005 Sheet trailing edge, side registration sensor error
When the light sensing voltage is less than 2copyir ( copyir.com ) com5 V even though the lightemitting duty ratio of side registration sensor 2 (LED2, PTR2) has been set to more than 66% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8006 Sheet trailing edge, side registration sensor error
When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of side registration sensor 2 (LED2, PTR2) has been set to 0% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8007 Sheet trailing edge, side registration sensor error
When the light sensing voltage is less than 2copyir ( copyir.com ) com5 V even though the lightemitting duty ratio of side registration sensor 3 (LED3, PTR3) has been set to more than 66% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8008 Sheet trailing edge, side registration sensor error
When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of side registration sensor 3 (LED3, PTR3) has been set to 0% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-8009 Sheet trailing edge, side registration sensor error
When the light sensing voltage is less than 2copyir ( copyir.com ) com5 V even though the lightemitting duty ratio of side registration sensor 4 (LED4, PTR4) has been set to more than 66% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E592-800A Sheet trailing edge, side registration sensor error
When the light sensing voltage is more than 2copyir ( copyir.com ) com0 V even though the lightemitting duty ratio of side registration sensor 4 (LED4, PTR4) has been set to 0% – Check the sheet trailing edge sensor (LED5, PTR5) and side registration sensor (LED1-4, PTR1-4) connectorscopyir ( copyir.com ) com – Replace the sheet trailing edge sensor (LED5, PTR5) and side registration sensors (LED1-4, PTR1-4)copyir ( copyir.com ) com
E593-8001 Side registration initializing error
When the side registration fails to leave the side registration home position sensor position even when the punch slide unit is moved 9 mm during the initial operation of the side registration motor – Check the side registration home position sensor (P161) connectorscopyir ( copyir.com ) com – Replace the side registration home position sensor (P161)copyir ( copyir.com ) com – Replace the side registration motor (M62)copyir ( copyir.com ) com
E593-8002 Side registration initializing error
When the side registration fails to return to the side registration home position sensor position even when the punch slide unit is moved 37 mm during the initial operation of the side registration motor – Check the side registration home position sensor (P161) connectorscopyir ( copyir.com ) com – Replace the side registration home position sensor (P161)copyir ( copyir.com ) com – Replace the side registration motor (M62)copyir ( copyir.com ) com
E5F0-8001 Saddle sheet positioning error
When the sheet positioning plate home position sensor fails to turn ON even when the sheet positioning plate motor is driven by 1500 pulses – Check the sheet positioning plate home position sensor (P17) connectorscopyir ( copyir.com ) com – Replace the sheet positioning plate home position sensor (P17)copyir ( copyir.com ) com – Replace the sheet positioning plate motor (M4)copyir ( copyir.com ) com
E5F0-8002 Saddle sheet positioning error
When the sheet positioning plate home position sensor fails to turn OFF even when the sheet positioning plate motor is driven by 300 pulses – Check the sheet positioning plate home position sensor (P17) connectorscopyir ( copyir.com ) com – Replace the sheet positioning plate home position sensor (P17)copyir ( copyir.com ) com – Replace the sheet positioning plate motor (M4)
E5F1-8001 Saddle sheet creasing error
When the number of detection pulses of the sheet creasing motor clock sensor has dropped below the prescribed number – Check the sheet creasing motor clock sensor (P14) and sheet creasing home position sensor (P121) connectorscopyir ( copyir.com ) com – Replace the sheet creasing motor clock sensor (P14) and sheet creasing home position sensor (P121)copyir ( copyir.com ) com – Replace the sheet creasing motor (M2)copyir ( copyir.com ) com
E5F1-8002 Saddle sheet creasing error
When the sheet creasing home position sensor status fails to change even when the sheet creasing motor is driven for 3 seccopyir ( copyir.com ) com When the sheet creasing home position sensor status fails to change even when the sheet creasing motor is driven for 3 seccopyir ( copyir.com ) com
E5F3-8001 Saddle alignment error
When the alignment plate home position sensor fails to turn ON even when the alignment motor is driven for 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com (or driven for 1copyir ( copyir.com ) com67 seccopyir ( copyir.com ) com during the initial operation) – Check the alignment plate home position sensor (P15S) connectorscopyir ( copyir.com ) com – Replace the alignment plate home position sensor (P15S)copyir ( copyir.com ) com – Replace the alignment motor (M5S)copyir ( copyir.com ) com
E5F3-8002 Saddle alignment error
When the alignment plate home position sensor fails to turn OFF even when the alignment motor is driven for 1 seccopyir ( copyir.com ) com – Check the alignment plate home position sensor (P15S) connectorscopyir ( copyir.com ) com – Replace the alignment plate home position sensor (P15S)copyir ( copyir.com ) com – Replace the alignment motor (M5S)copyir ( copyir.com ) com
E5F4-8001 Saddle rear stapler error
When the stitch operation home position sensor fails to turn OFF even when the stitch motor (rear) has been run in the forward direction for at least 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com – Check the stitch operation home position sensor (rear, MS5S) connectorscopyir ( copyir.com ) com – Replace the stitch operation home position sensor (rear, MS5S)copyir ( copyir.com ) com – Replace the stitch motor (rear, M6S)copyir ( copyir.com ) com
E5F4-8002 Saddle rear stapler error
When the stitch operation home position sensor fails to turn ON even when the stitch motor (rear) has been run in the reverse direction for at least 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com – Check the stitch operation home position sensor (rear, MS5S) connectorscopyir ( copyir.com ) com – Replace the stitch operation home position sensor (rear, MS5S)copyir ( copyir.com ) com – Replace the stitch motor (rear, M6S)copyir ( copyir.com ) com
E5F5-8001 Saddle front stapler error
When the stitch operation home position sensor fails to turn OFF even when the stitch motor (front) has been run in the forward direction for at least 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com – Check the stitch operation home position sensor (front, MS7S) connectorscopyir ( copyir.com ) com – Replace the stitch operation home position sensor (front, MS7S)copyir ( copyir.com ) com – Replace the stitch motor (front, M7S)copyir ( copyir.com ) com
E5F5-8002 Saddle front stapler error
When the stitch operation home position sensor fails to turn ON even when the stitch motor (front) has been run in the reverse direction for at least 0copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com – Check the stitch operation home position sensor (front, MS7S) connectorscopyir ( copyir.com ) com – Replace the stitch operation home position sensor (front, MS7S)copyir ( copyir.com ) com – Replace the stitch motor (front, M7S)copyir ( copyir.com ) com
E5F6-8001 Saddle sheet push plate stapler error
When the sheet push plate home position sensor fails to turn ON even when the sheet push plate motor has been run for at least 0copyir ( copyir.com ) com3 seccopyir ( copyir.com ) com – Check the sheet push plate home position sensor (P114S) connectorscopyir ( copyir.com ) com – Replace the sheet push plate home position sensor (P114S)copyir ( copyir.com ) com – Replace the sheet push plate motor (M8S)copyir ( copyir.com ) com
E5F6-8002 Saddle sheet push plate stapler error
When the sheet push plate home position sensor fails to turn OFF even when the sheet push plate motor has been run for at least 80 ms – Check the sheet push plate home position sensor (P114S) connectorscopyir ( copyir.com ) com – Replace the sheet push plate home position sensor (P114S)copyir ( copyir.com ) com – Replace the sheet push plate motor (M8S)copyir ( copyir.com ) com
E5F6-8003 Saddle sheet push plate stapler error
When the sheet push plate edge position sensor fails to turn OFF even when the sheet push plate motor has been run for at least 80 ms – Check the sheet push plate home position sensor (P114S) connectorscopyir ( copyir.com ) com – Replace the sheet push plate home position sensor (P114S)copyir ( copyir.com ) com – Replace the sheet push plate motor (M8S)copyir ( copyir.com ) com
E5F6-8004 Saddle sheet push plate stapler error
When the number of pulses detected by the sheet push plate motor clock sensor has dropped below the prescribed number – Check the sheet push plate home position sensor (P114S) connectorscopyir ( copyir.com ) com – Replace the sheet push plate home position sensor (P114S)copyir ( copyir.com ) com – Replace the sheet push plate motor (M8S)copyir ( copyir.com ) com
E5F6-8005 Saddle sheet push plate stapler error
When the sheet push plate edge position sensor fails to turn ON even when the sheet push plate motor has been run for at least 0copyir ( copyir.com ) com3 seccopyir ( copyir.com ) com – Check the sheet push plate home position sensor (P114S) connectorscopyir ( copyir.com ) com – Replace the sheet push plate home position sensor (P114S)copyir ( copyir.com ) com – Replace the sheet push plate motor (M8S)copyir ( copyir.com ) com
E5F9-8001 Saddle switch error
When the entrance door switch is in the open status even when all the covers are closed – Check the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com – Replace the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com
E5F9-8002 Saddle switch error
When the delivery door switch is in the open status even when all the covers are closed – Check the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com – Replace the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com
E5F9-8003 Saddle switch error
When the front cover close detection door switch is in the open status even when all the covers are closed – Check the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com – Replace the entrance door switch (MSW1), delivery door switch (MSW3) and front cover close detection switch (MSW101)copyir ( copyir.com ) com
E602 Hard disk trouble
E604 Defective or insufficient image memory (SDRAM) Increase the amount of the SDRAM memorycopyir ( copyir.com ) com
E609-0008 Hard disk trouble
When the HDD fails to reach the prescribed temperature within the prescribed period of time when it is started up Replace with an HDD which is guaranteed to operate at low temperaturescopyir ( copyir.com ) com
E609-0009 Hard disk trouble
When the HDD fails to reach the prescribed temperature when its operation is restored from the sleep mode Replace with an HDD which is guaranteed to operate at low temperaturescopyir ( copyir.com ) com
E610 Hard disk encryption key failure
E611-0000 Rebooting repeat error due to SRAM failure, etccopyir ( copyir.com ) com
Rebooting error when the SRAM data has been destroyed, the job information saved in the SRAM can no longer be read or when rebooting is otherwise repeated when the power is shut off and restored – Clear the SRAMcopyir ( copyir.com ) com – Clear the power shutdown guaranteed jobscopyir ( copyir.com ) com
E674 FAX board communication trouble Check the FAX board and main controller PCB connectionscopyir ( copyir.com ) com Replace the FAX boardcopyir ( copyir.com ) com Replace the main controller PCBcopyir ( copyir.com ) com
E677 External controller trouble Check the cable connectionscopyir ( copyir.com ) com Re-install the external controller system
E710-0001 IPC initializing error
When the ready status fails to be established within 3 seccopyir ( copyir.com ) com after the IPC chip started up Check the cable connectionscopyir ( copyir.com ) com
E711-0001 IPC communication error
When error occurrence was set 4 or more times in the error register of the IPC chip within 1copyir ( copyir.com ) com5 seccopyir ( copyir.com ) com Check the cable connectionscopyir ( copyir.com ) com Replace the ADF controller PCBcopyir ( copyir.com ) com Replace the reader controller PCBcopyir ( copyir.com ) com
E712-0000 ADF/reader communication error
When communication between the reader and ADF was interrupted and 5 or more seccopyir ( copyir.com ) com have elapsed without communication having been restored Check the connector connections between the reader and ADFcopyir ( copyir.com ) com
E713-0004 Finisher/printer communication error
When communication between the finisher and copier was interrupted Check the cable connectionscopyir ( copyir.com ) com Replace the finisher controller PCBcopyir ( copyir.com ) com Replace the DC controller PCBcopyir ( copyir.com ) com
E716-0000 Cassette pedestal/printer communication error
When trouble occurs in the data communicationcopyir ( copyir.com ) com When the DC controller or cassette pedestal controller PCB is defective Check the cable connectionscopyir ( copyir.com ) com Replace the pedestal PCBcopyir ( copyir.com ) com Replace the DC controller PCBcopyir ( copyir.com ) com
E717-0001 Error in communication with NE controller
When the NE controller which was connected before the power was turned OFF could not be recognized when the power was turned back ON Check the cable connections
E717-0002 Error in communication with NE controller
When the IPC has a broken or disconnected wire or when an error has occurred where IPC communication cannot be recovered In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERRcopyir ( copyir.com ) com
E719-0001 Error in communication with coin vendor/card reader
When the coin vendor which was connected before the power was turned OFF could not be recognized when the power was turned back ON Check the cable connectionscopyir ( copyir.com ) com
E719-0002 Error in communication with coin vendor/card reader
– When a wire in the IPC cable connected with the coin vendor is broken or disconnected or when an error has occurred where IPC communication cannot be recovered – When a broken or disconnected wire in the sheet feed/delivery signal line was detected – When an illegal connection has been detected (when Tx and Rx of IPC have been short-circuited) In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
E719-0011 Error in communication with coin vendor/card reader
When the card reader which was connected before the power was turned OFF could not be recognized when the power was turned back ON In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
E719-0012 Error in communication with coin vendor/card reader
When a wire in the IPC cable connected with the card reader is broken or disconnected or when an error has occurred where IPC communication cannot be recovered In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR
E730 PDL error Turn the main power OFF and back ONcopyir ( copyir.com ) com Check the OPEN interface board and cable connectionscopyir ( copyir.com ) com Replace the external controllercopyir ( copyir.com ) com Replace the OPEN interface boardcopyir ( copyir.com ) com Replace the main controller PCBcopyir ( copyir.com ) com
E731 UFR PCB error Check the UFR PCB connectionscopyir ( copyir.com ) com Replace the UFR PCBcopyir ( copyir.com ) com Replace the main controller PCBcopyir ( copyir.com ) com
E732-0001 Reader communication error
DDI-S communication error Check the connections between the reader controller PCB and main controller PCBcopyir ( copyir.com ) com Check the power supply of the readercopyir ( copyir.com ) com
E733-0000 Printer communication error
When the printer cannot be detected at startup Check the connections between the DC controller PCB and main controller PCBcopyir ( copyir.com ) com Check the power supply of the printercopyir ( copyir.com ) com
E733-0001 Printer communication error
DDI-P communication error Check the connections between the DC controller PCB and main controller PCBcopyir ( copyir.com ) com Check the power supply of the printercopyir ( copyir.com ) com
E740-0002 Ethernet board trouble
When an illegal MAC address was detected at startup Replace the Ethernet board*copyir ( copyir.com ) com Replace the main controller PCB (sub: LAN-bar)
E740-003 Ethernet board trouble
When an illegal network ID was detected at startup Replace the Ethernet board*copyir ( copyir.com ) com Replace the main controller PCB (sub: LAN-bar)
E743-0000 DDI communication error
When the reader controller PCB has detected trouble in communication between the main controller PCB and reader controller PCB Disconnect and re-connect the reader communication cable connector, or replace the reader controller PCBcopyir ( copyir.com ) com Replace the main controller PCBcopyir ( copyir.com ) com
E744 Language file/BootROM error Upgrade the language file versioncopyir ( copyir.com ) com
E747 Main controller PCB error Turn the main power OFF and back ONcopyir ( copyir.com ) com Replace the main controller PCB (main)copyir ( copyir.com ) com Disconnect and re-connect the main controller PCB (sub R)
E748 Main controller PCB error Disconnect and re-connect the main controller PCBs (sub SJ, PE or R) or replacecopyir ( copyir.com ) com Disconnect and re-connect the OPEN interface PCB or replacecopyir ( copyir.com ) com Replace the main controller PCB (main)copyir ( copyir.com ) com
E749-0001 Instruction to restart accompanying change in product configuration
When the existing BootROM has been replaced with the BootROM of a different kind (when a PDL option was installed, etccopyir ( copyir.com ) com) Reset by turning the main power OFF and back ONcopyir ( copyir.com ) com
E749-1001 Instruction to restart accompanying change in product configuration
Error where SDRAM memory as high as 1 GB remains although the controller board version is an old one Check the combination of the main controller PCB and SDRAMcopyir ( copyir.com ) com
E751-00Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Trouble in the drum unit connections (trouble at the printer side) Check the drum unit connections or replace the unitcopyir ( copyir.com ) com
E751-01Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Write error in the memory inside the drum unit Check the drum unit connections or replace the unitcopyir ( copyir.com ) com
E751-02Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Data error in the memory inside the drum unit Check the drum unit connections or replace the unitcopyir ( copyir.com ) com
E751-03Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Write error in the memory inside the drum unit (when the number of retries has exceeded the rating) Check the drum unit connections or replace the unitcopyir ( copyir.com ) com
E751-10Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Trouble in the toner cartridge connections (trouble at the printer side) Check the toner cartridge connections or replace the cartridgecopyir ( copyir.com ) com
E751-11Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Write error in the memory inside the toner cartridge Check the toner cartridge connections or replace the cartridgecopyir ( copyir.com ) com
E751-12Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Data error in the memory inside the toner cartridge Check the toner cartridge connections or replace the cartridgecopyir ( copyir.com ) com
E751-13Xx Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Write error in the memory inside the toner cartridge (when the number of retries has exceeded the rating) Check the toner cartridge connections or replace the cartridgecopyir ( copyir.com ) com
E804-0000 Controller fan error
When a shutdown of the power supply fan has been detected Check the power supply fan connections or replace the fancopyir ( copyir.com ) com
E804-0004 Controller fan error
When a shutdown of the controller fan has been detected Check the controller fan connections or replace the fancopyir ( copyir.com ) com
E805-0001 Fan error
When a shutdown of the fixing heat exhaust fan has been detected Check the fixing heat exhaust fan connections or replace the fancopyir ( copyir.com ) com
E805-0002 Fan error
When a shutdown of the cleaner fan has been detected Check the cleaner fan connections or replace the fancopyir ( copyir.com ) com
E805-0003 Fan error
When a shutdown of the IH power supply fan has been detected Check the IH power supply fan connections or replace the fancopyir ( copyir.com ) com
جهت اطلاع از انواع مدلهاوقیمت دستگاههای فتوکپی رنگی لطفا کلیک کنید
جهت اطلاع از انواع مدلهاوقیمت دستگاههای فتوکپی رومیزی لطفا کلیک کنید
جهت اطلاع از انواع مدلهاوقیمت دستگاههای فتوکپی متوسط لطفا کلیک کنید
جهت اطلاع از انواع مدلهاوقیمت دستگاههای ریسو گراف لطفا کلیک کنید
جهت اطلاع از انواع مدلها وقیمت دستگاههای پلاتر لطفا کلیک کنید
جهت اطلاع از انواع مدلها وقیمت دستگاههای فتوکپی تکثیر لطفا کلیک کنید