C0104    Tray 3/4 feeder transportation motor failure to turn
• The lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M25 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M25 for proper drive coupling and correct as necessary   copyir.com 3 M25 operation check PFTDB CN12PFTDB-6 (LOCK) V-12   copyir.com 4 Change M25   copyir.com 5 Change PFTDB   copyir.com 6 Change PRCB   copyir.com
C0105    Tray 3/4 feeder transportation motor turning at abnormal timing
• The lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M25 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M25 for proper drive coupling and correct as necessary   copyir.com 3 M25 operation check PFTDB CN12PFTDB-6 (LOCK) V-12   copyir.com 4 Change M25   copyir.com 5 Change PFTDB   copyir.com 6 Change PRCB   copyir.com
C0202    Tray 1 feeder up/down abnormality
• The tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started   copyir.com    1 Check the M6 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M6 for proper drive coupling and correct as necessary   copyir.com 3 PS6 I/O check, sensor check PFTDB CN4PFTDB-3 (ON) P-4   copyir.com 4 M6 operation check PFTDB CN18PFTDB-9 (ON) V-3   copyir.com 5 Change M6   copyir.com 6 Change PFTDB   copyir.com 7 Change PRCB   copyir.com
C0204    Tray 2 feeder up/down abnormality
• The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started   copyir.com    1 Check the M8 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M8 for proper drive coupling and correct as necessary   copyir.com 3 PS14 I/O check, sensor check PFTDB CN8BPFTDB-10 (ON) P-7   copyir.com 4 M8 operation check PFTDB CN6PFTDB-9 (ON) V-4   copyir.com 5 Change M8   copyir.com 6 Change PFTDB   copyir.com 7 Change PRCB   copyir.com
C0206    Tray 3 feeder up/down abnormality
• The tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started   copyir.com    1 Check the M23 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M23 for proper drive coupling and correct as necessary   copyir.com 3 PS22 I/O check, sensor check PFTDB CN10BPFTDB-6 (ON) V-6   copyir.com 4 M23 operation check PFTDB CN11PFTDB-4 (ON) V-9   copyir.com 5 Change M23   copyir.com 6 Change PFTDB   copyir.com 7 Change PRCB   copyir.com
C0208    Tray 4 feeder up/down abnormality
• The tray 4 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started   copyir.com    1 Check the M24 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M24 for proper drive coupling and correct as necessary   copyir.com 3 PS27 I/O check, sensor check PFTDB CN9BPFTDB-6 (ON) V-8   copyir.com 4 M24 operation check PFTDB CN11PFTDB-2 (ON) V-9   copyir.com 5 Change M23   copyir.com 6 Change PFTDB   copyir.com 7 Change PRCB   copyir.com
C0211    Manual feed up/down abnormality
• The bypass paper limit sensor (PS35) or bypass paper lower sensor (PS36) is not blocked even after the lapse of a given period of time after the manual feed tray up-and-down motion has been started   copyir.com    1 Check the M28 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M28 for proper drive coupling and correct as necessary   copyir.com 3 PS35 I/O check, sensor check PFTDB CN26BPFTDB<B>-10 (ON) P-12   copyir.com 4 PS36 I/O check, sensor check PFTDB CN9BPFTDB<A>-11 (ON) P-11   copyir.com 5 M28 operation check PFTDB CN26PFTDB<B>-11,12 P-12   copyir.com 6 Change M28   copyir.com 7 Change PFTDB   copyir.com
C0216    LCT up/down abnormality
C0301    Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM1 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM1 operation check PRCB CN11PRCB-3 (REM) PRCB CN11PRCB-5 (LOCK) K-3   copyir.com 4 Change FM1   copyir.com 5 Change PRCB   copyir.com
C0351    Paper cooling fan trouble
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM13 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM13 operation check PRCB CN10PRCB-4 (REM) PRCB CN10PRCB-6 (LOCK) K-6   copyir.com 4 Change FM13   copyir.com 5 Change PRCB   copyir.com
C1004    FNS communication error
C1008    RU communication error
C1101    Shift roller motor drive failure
C1102    Tray ascent/descent drive failure
C1103    Aligning plate drive failure
C1104    Paper exit roller drive failure
C1105    Paper exit drive failure
C1106    Stapler movement drive failure
C1107    Stapler clincher rotation drive failure
C1108    Stapler rotation motor drive failure
C1109    Stapler F unit drive failure
C1110    Stapler R unit drive failure
C1111    Stapler F unit clincher drive failure
C1112    Stapler R unit clincher drive failure
C1113    Saddle stitching stopper motor drive failure
C1114    Stapler side guide motor drive failure
C1115    Folding knife motor drive failure
C1116    Folding transfer motor drive failure
C1124    Sheet feeder up/down drive (lower)
C1125    Sheet feeder up/down drive (upper)
C1126    Sheet feeder transportation drive
C1127    Punch kit movement motor drive failure
C1132    Output OP punch driving motor malfunction
C1137    Gate motor drive failure
C1182    Shift motor mechanism failure
C1183    Finishing option elevator drive malfunction
C1190    Finishing option aligning bar moving mechanism malfunction 1
C1191    Finishing option aligning bar moving mechanism malfunction 2
C11A0    Paper holding drive failure
C11A1    Finishing option exit roller pressure/retraction failure
C11A2    Saddle exit roller pressure/retraction failure
C11A3    Shutter drive failure
C11A4    Saddle exit motor failure
C11A5    Saddle in & out guide motor failure
C11A6    Saddle layable guide drive failure
C11B0    Finishing option stapler unit CD drive failure
C11B2    Finishing option stapling mechanism malfunction 1
C11B5    Side staple 1 drive failure
C11B6    Side staple 2 drive failure
C11C0    Punch motor malfunction
C11D0    Crease motor drive failure
C11E0    Route switch malfunction
C1301    Finishing option cooling fan motor failure
C1402    FNS non-volatile memory failure
C2101    PC charge cleaning malfunction
• During backward movement of the cleaner, the charging cleaner home sensor is not blocked after a predetermined period of time has elapsed   copyir.com    1 Check the imaging unit/K for proper connection and correct as necessary   copyir.com 2 Check the M15 connector for proper connection and correct as necessary   copyir.com 3 PS43 I/O check, sensor check PRCB CN8PRCB-8 (ON) C-12   copyir.com 4 PS44 I/O check, sensor check PRCB CN8PRCB-11 (ON) C-13   copyir.com 5 M15 operation check PRCB CN8PRCB-3 to 4 C-12   copyir.com 6 Change imaging unit /K   copyir.com 7 Change M15   copyir.com 8 Change PRCB   copyir.com
C2151    Secondary transfer roller pressure welding alienation
• The pressure welding alienation sensor doesn’t turn OFF (retracting) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is retracting   copyir.com • The pressure welding alienation sensor doesn’t turn ON (pressuring) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is pressuring   copyir.com    1 Check the M3 connector for proper connection and correct as necessary   copyir.com 2 PS50 I/O check, sensor check PRCB CN36PRCB-9 (ON) K-4   copyir.com 3 M3 operation check PRCB CN11PRCB-1 (REM) K-3   copyir.com 4 Change M3   copyir.com 5 Change PRCB   copyir.com
C2152    Transfer belt pressure welding alienation
• At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations   copyir.com See the table below   copyir.com • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations   copyir.com See the table below   copyir.com Operation Position Sensor status (K: Color) • Color and K retraction – K pressure • Color and K pressure – K pressure ON (not blocked) :OFF (blocked) pressure • Color and K retraction – Color and K pressure • K pressure – Color and K pressure Color and K pressure ON (not blocked):ON (not blocked) • K pressure – Color and K retraction • Color and K pressure -Color and K Color and K retraction OFF (blocked): OFF (blocked)    1 Check the M21 connector for proper connection and correct as necessary   copyir.com 2 PS51 I/O check, sensor check PRCB CN11PRCB-12 (ON) K-2   copyir.com 3 PS52 I/O check, sensor check PRCB CN11PRCB-15 (ON) K-2   copyir.com 4 M21 operation check PRCB CN17PRCB-1 to 4 K-2   copyir.com 5 Change M21   copyir.com 6 Change MFPB   copyir.com
C2160    PC charge (C) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed   copyir.com Then the trouble code corresponding to the IU color is displayed   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV1 connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV1   copyir.com 6 Change PRCB   copyir.com
C2161    PC charge (M) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed   copyir.com Then the trouble code corresponding to the IU color is displayed   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV1 connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV1   copyir.com 6 Change PRCB   copyir.com
C2162    PC charge (Y) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed   copyir.com Then the trouble code corresponding to the IU color is displayed   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV1 connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV1   copyir.com 6 Change PRCB   copyir.com
C2163    PC charge (K) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed   copyir.com Then the trouble code corresponding to the IU color is displayed   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV1 connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV1   copyir.com 6 Change PRCB   copyir.com
C2164    PC charge malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed   copyir.com Then the trouble code corresponding to the IU color is displayed   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV1 connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV1   copyir.com 6 Change PRCB   copyir.com
C2204    Waste toner agitating motor’s failure to turn
• The waste toner agitating motor lock sensor continues to be blocked or unblocked for a predetermined period of time when the motor is turning   copyir.com    1 Change the waste toner box   copyir.com 2 Check the M20 connector for proper connection and correct as necessary   copyir.com 3 Check the connector of motor for proper drive coupling and correct as necessary   copyir.com 4 M20 operation check PRCB CN15PRCB-11 to 14 C-12   copyir.com 5 Change M20   copyir.com 6 Change PRCB   copyir.com
C2253    Color PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M16 connector for proper connection and correct as necessary   copyir.com 2 Check the M16 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M16 operation check PRCB CN12PRCB-9 (REM) PRCB CN12PRCB-12 (LOCK) K-9   copyir.com 5 Change M16   copyir.com 6 Change PRCB   copyir.com
C2254    Color PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M16 connector for proper connection and correct as necessary   copyir.com 2 Check the M16 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M16 operation check PRCB CN12PRCB-9 (REM) PRCB CN12PRCB-12 (LOCK) K-9   copyir.com 5 Change M16   copyir.com 6 Change PRCB   copyir.com
C2255    Color developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M17 connector for proper connection and correct as necessary   copyir.com 2 Check the M17 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M17 operation check PRCB CN12PRCB-14 (REM) PRCB CN12PRCB-17 (LOCK) K-8   copyir.com 5 Change M17   copyir.com 6 Change PRCB   copyir.com
C2256    Color developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M17 connector for proper connection and correct as necessary   copyir.com 2 Check the M17 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M17 operation check PRCB CN12PRCB-14 (REM) PRCB CN12PRCB-17 (LOCK) K-8   copyir.com 5 Change M17   copyir.com 6 Change PRCB   copyir.com
C2257    Cleaner motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M38 connector for proper connection and correct as necessary   copyir.com 2 Check the M38 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M38 operation check PRCB CN13PRCB-11 (LOCK) K-10 to 11   copyir.com 5 Change M38   copyir.com 6 Change PRCB   copyir.com
C2258    Cleaner motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M38 connector for proper connection and correct as necessary   copyir.com 2 Check the M38 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M38 operation check PRCB CN13PRCB-11 (LOCK) K-10 to 11   copyir.com 5 Change M38   copyir.com 6 Change PRCB   copyir.com
C2259    K developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M19 connector for proper connection and correct as necessary   copyir.com 2 Check the M19 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M19 operation check PRCB CN12PRCB-2 (REM) PRCB CN12PRCB-5 (LOCK) K-9   copyir.com 5 Change M19   copyir.com 6 Change PRCB   copyir.com
C225A    K developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M19 connector for proper connection and correct as necessary   copyir.com 2 Check the M19 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M19 operation check PRCB CN12PRCB-2 (REM) PRCB CN12PRCB-5 (LOCK) K-9   copyir.com 5 Change M19   copyir.com 6 Change PRCB   copyir.com
C225B    K PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M18 connector for proper connection and correct as necessary   copyir.com 2 Check the M18 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M18 operation check PRCB CN13PRCB-15 (REM) PRCB CN13PRCB-18 (LOCK) K-10   copyir.com 5 Change M18   copyir.com 6 Change PRCB   copyir.com
C225C    K PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M18 connector for proper connection and correct as necessary   copyir.com 2 Check the M18 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M18 operation check PRCB CN13PRCB-15 (REM) PRCB CN13PRCB-18 (LOCK) K-10   copyir.com 5 Change M18   copyir.com 6 Change PRCB   copyir.com
C2351    K toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the FM8 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM8 operation check PRCB CN10PRCB-10 (REM) PRCB CN10PRCB-12 (LOCK) K-5   copyir.com 4 Change FM8   copyir.com 5 Change PRCB   copyir.com
C2352    Color toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the FM7 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM7 operation check PRCB CN10PRCB-7 (REM) PRCB CN10PRCB-9 (LOCK) K-5   copyir.com 4 Change FM7   copyir.com 5 Change PRCB   copyir.com
C2353    IU cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the FM15 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM15 operation check REYB PH CN5REYB PH-1 (REM) REYB PH CN5REYB PH-3 (LOCK) B-7   copyir.com 4 Change FM15   copyir.com 5 Change REYB/PH   copyir.com 6 Change PRCB   copyir.com
C2354    Rear side cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the FM16 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM16 operation check PRCB CN26PRCB-2 (REM) PRCB CN26PRCB-3 (LOCK) C-16   copyir.com 4 Change FM16   copyir.com 5 Change PRCB   copyir.com
C2451    Release new transfer belt unit
• A new installation is not detected when a new transfer cleaner unit (image transfer belt unit) is installed   copyir.com    1 Reinstall unit   copyir.com 2 Check there is a short circuit in the fuse of the transfer belt unit   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change PRCB   copyir.com
C2551    Abnormally low toner density detected cyan TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper   copyir.com    1 Perform image troubleshooting procedure if image density is low   copyir.com 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 Reinstall imaging unit   copyir.com 4 Reinstall toner cartridge   copyir.com 5 M9, M10, M11 operation check (At this time, IU must be non-installation   copyir.com) M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 6 M13, M14 operation check M13: PRCB CN17PRCB-5 to 8 M14: PRCB CN17PRCB-9 to 12 K-1   copyir.com 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them   copyir.com 8 Change imaging unit   copyir.com 9 Change PRCB   copyir.com
C2552    Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing unit which is determined by Toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively   copyir.com    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Reinstall toner cartridge   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com 6 Change sub hopper unit   copyir.com
C2553    Abnormally low toner density detected magenta TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper   copyir.com    1 Perform image troubleshooting procedure if image density is low   copyir.com 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 Reinstall imaging unit   copyir.com 4 Reinstall toner cartridge   copyir.com 5 M9, M10, M11 operation check (At this time, IU must be non-installation   copyir.com) M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 6 M13, M14 operation check M13: PRCB CN17PRCB-5 to 8 M14: PRCB CN17PRCB-9 to 12 K-1   copyir.com 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them   copyir.com 8 Change imaging unit   copyir.com 9 Change PRCB   copyir.com
C2554    Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively   copyir.com    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Reinstall toner cartridge   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com 6 Change sub hopper unit   copyir.com
C2555    Abnormally low toner density detected yellow TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper   copyir.com    1 Perform image troubleshooting procedure if image density is low   copyir.com 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 Reinstall imaging unit   copyir.com 4 Reinstall toner cartridge   copyir.com 5 M9, M10, M11 operation check (At this time, IU must be non-installation   copyir.com) M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 6 M13, M14 operation check M13: PRCB CN17PRCB-5 to 8 M14: PRCB CN17PRCB-9 to 12 K-1   copyir.com 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them   copyir.com 8 Change imaging unit   copyir.com 9 Change PRCB   copyir.com
C2556    Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively   copyir.com    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Reinstall toner cartridge   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com 6 Change sub hopper unit   copyir.com
C2557    Abnormally low toner density detected black TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper   copyir.com    1 Perform image troubleshooting procedure if image density is low   copyir.com 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M12 operation check (At this time, IU must be non-installation   copyir.com) PRCB CN16PRCB-13 to 16 C-22 4 M14 operation check PRCB CN17PRCB-9 to 12 K-1   copyir.com 5 Reinstall imaging unit   copyir.com 6 Reinstall toner cartridge   copyir.com 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them   copyir.com 8 Change imaging unit /K   copyir.com 9 Change PRCB   copyir.com
C2558    Abnormally high toner density detected black TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively   copyir.com    1 Correct the TCR connection on the underside of the imaging unit if faulty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Reinstall toner cartridge   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com 6 Change sub hopper unit   copyir.com
C2559    Cyan TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value   copyir.com    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 M9, M10, M11 operation check M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 3 Reinstall imaging unit   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C255A    Magenta TCR sensor adjustment failure    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 M9, M10, M11 operation check M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 3 Reinstall imaging unit   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C255B    Yellow TCR sensor adjustment failure    1 Clean the TCR sensor window on the underside of the imaging unit if dirty   copyir.com 2 M9, M10, M11 operation check M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23   copyir.com 3 Reinstall imaging unit   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C255C    Black TCR sensor adjustment failure    1 Clean or correct each contact of the imaging unit if faulty   copyir.com 2 M12 operation check PRCB CN16PRCB-13 to 16 C-22   copyir.com 3 Reinstall imaging unit /K   copyir.com 4 Change imaging unit /K   copyir.com 5 Change PRCB   copyir.com
C2650    Main backup media access error
• Contact the responsible people of KMBT before taking some countermeasures   copyir.com    1 Check the connector (CN23PRCB) on PRCB, the connector (CN1SV ERB) on SV ERB, and the harness between the boards for proper connection and correct as necessary   copyir.com 2 Change PRCB 1   copyir.com Turn OFF the main power switch and replace the current PRCB with a new one   copyir.com (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model   copyir.com) 2   copyir.com Update the PRCB firmware   copyir.com 3   copyir.com After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started   copyir.com Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected   copyir.com 4   copyir.com When the trouble cannot be solved, reinstall the removed PRCB to the original board   copyir.com NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SV ERB   copyir.com 3 Change SV ERB 1   copyir.com Replace the current SV ERB with a new one   copyir.com 2   copyir.com Turn ON the main power switch and check to see that warm-up is started   copyir.com (One minute is spent to prepare the new SV ERB for use   copyir.com During the period, the control panel backlight stays off   copyir.com) Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected   copyir.com 3   copyir.com Make the specified readjustments   copyir.com 4 If the above actions do not solve the problem, contact KMBT   copyir.com
C2651    EEPROM access error (IU C)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2652    EEPROM access error (IU M)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2653    EEPROM access error (IU Y)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2654    EEPROM access error (IU K)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty   copyir.com 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2A01    EEPROM access error (TC C)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Check that CN29 harness on PRCB has a ferrite core   copyir.com If not, attach the ferrite core to the harness   copyir.com 6 Change PRCB   copyir.com
C2A02    EEPROM access error (TC M)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Check that CN29 harness on PRCB has a ferrite core   copyir.com If not, attach the ferrite core to the harness   copyir.com 6 Change PRCB   copyir.com
C2A03    EEPROM access error (TC Y)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Check that CN29 harness on PRCB has a ferrite core   copyir.com If not, attach the ferrite core to the harness   copyir.com 6 Change PRCB   copyir.com
C2A04    EEPROM access error (TC K)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com • The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Check that CN29 harness on PRCB has a ferrite core   copyir.com If not, attach the ferrite core to the harness   copyir.com 6 Change PRCB   copyir.com
C3101    Fusing roller separation failure
• With the fusing roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure retraction motor started rotating   copyir.com • With the fusing roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure retraction motor started rotating   copyir.com • With the pressure roller being pressed, the pressure home sensor did not turn ON (pressed) even after the fusing retraction position sensor counted up the specified number of pulse after the fusing pressure retraction motor started rotating   copyir.com    1 Check the M29 connector for proper connection and correct as necessary   copyir.com 2 PS55 I/O check, sensor check PRCB CN8PRCB-14 (ON) C-13   copyir.com 3 M29 operation check PRCB CN8PRCB-1 to 2 (ON) C-12   copyir.com 4 Change M29   copyir.com 5 Change fusing unit   copyir.com 6 Change PRCB   copyir.com
C3102    Fusing roller failure to turn
• When the IH power supply is turned ON, pulse signals are not input either of the heating roller rotation sensor/1 or the heating roller rotation sensor/2 within a predetermined period of time   copyir.com    1 Check the fusing unit for proper installation and correct as necessary   copyir.com 2 Check the M30 connector for proper connection and correct as necessary   copyir.com 3 PS56 I/O check, sensor check PRCB CN25PRCB-11 (ON) C-17 4 PS57 I/O check, sensor check PRCB CN25PRCB-14 (ON) C-17 5 M30 operation check PRCB CN7PRCB-3 (REM) PRCB CN7PRCB-6 (LOCK) K-7   copyir.com 6 Change M30   copyir.com 7 Change fusing unit   copyir.com 8 Change PRCB   copyir.com
C3201    Fusing motor failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M30 connector for proper connection and correct as necessary   copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary   copyir.com 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary   copyir.com 4 M30 operation check PRCB CN7PRCB-3 (REM) PRCB CN7PRCB-6 (LOCK) K-7   copyir.com 5 Change M30   copyir.com 6 Change PRCB   copyir.com
C3202    Fusing motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M30 connector for proper connection and correct as necessary   copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary   copyir.com 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary   copyir.com 4 M30 operation check PRCB CN7PRCB-3 (REM) PRCB CN7PRCB-6 (LOCK) K-7   copyir.com 5 Change M30   copyir.com 6 Change PRCB   copyir.com
C3303    Fusing cooling fan motor/ 1 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM2 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM2 operation check PRCB CN6PRCB-4 (REM) PRCB CN6PRCB-6 (LOCK) K-6   copyir.com 4 Change FM2   copyir.com 5 Change PRCB   copyir.com
C3304    Fusing cooling fan motor/ 2 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM4 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM4 operation check PRCB CN11PRCB-6 (REM) PRCB CN11PRCB-8 (LOCK) K-3   copyir.com 4 Change FM4   copyir.com 5 Change PRCB   copyir.com
C3305    Fusing cooling fan motor/ 3 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM5 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM5 operation check PRCB CN11PRCB-9 (REM) PRCB CN11PRCB-11 (LOCK) K-3   copyir.com 4 Change FM5   copyir.com 5 Change PRCB   copyir.com
C3423    Fusing heaters trouble (pressurizing side)
• After warm-up operation starts, the fusing pressure roller thermistor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3424    Fusing heaters trouble (soaking side)
• After warm-up operation starts, the soaking roller thermistor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3425    Fusing heaters trouble (NC sensor)
• After warm-up operation starts, the NC sensor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3461    Release new fusing unit
• A new installation is not detected when a new fusing Unit is installed   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the fusing unit, PRCB for proper connection and correct or change as necessary   copyir.com 3 Reinstall fusing unit   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com
C3721    Fusing abnormally high temperature detection (Center of the heating roller)
• The heating roller thermistor/3 continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com • The signal is turned ON to activate the hard ratchet in the middle of the heating side   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3722    Fusing abnormally high temperature detection (Edge of the heating roller)
• The heating roller thermistor/2 continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com • The signal is turned ON to activate the hard ratchet at the edges of the heating side   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3723    Fusing abnormally high temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3724    Fusing abnormally high temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com • The signal is turned ON to activate the hard ratchet on the soaking side   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3725    Fusing abnormally high temperature detection (NS sensor)
• The NC sensor continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3822    Fusing abnormally low temperature detection (Edge of the heating roller)
• The heating roller thermistor/2 continues to detect a temperature lower than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3823    Fusing abnormally low temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3824    Fusing abnormally low temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature lower than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3825    Fusing abnormally low temperature detection (NC sensor)
• The NC sensor continues to detect a temperature lower than a predetermined one for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3921    Fusing sensor wire breaks detection (Center of the heating roller)
• At the warm-up stage, the heating roller thermistor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3922    Fusing sensor wire breaks detection (Edge of the heating roller)
• At the warm-up stage, the heating roller thermistor/2 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3923    Fusing sensor wire breaks detection (pressurizing side)
• At the warm-up stage, the fusing pressure roller thermistor voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3924    Fusing sensor wire breaks detection (soaking side)
• At the warm-up stage, the soaking roller thermistor/1 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change DCPU   copyir.com
C3925    Fusing sensor wire breaks detection (NC sensor)
• At the warm-up stage, the NC sensor voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change IHPU   copyir.com 6 Change PRCB   copyir.com 7 Change REDB   copyir.com
C3B02    IH malfunction (CPU)
• A failure in communication with the fusing CPU continues for a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, degaussing coil unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change degaussing coil unit   copyir.com 6 Change IHPU   copyir.com 7 Change PRCB   copyir.com 8 Change REDB   copyir.com
C3B03    IH malfunction (monitor)
• Though the IH heater is ON, this status cannot be detected mechanically   copyir.com (IH heater operation failure) • Though the IH heater is OFF, mechanically, the ON status is detected   copyir.com (Malfunction of IH heater operation)    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, degaussing coil unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change degaussing coil unit   copyir.com 6 Change IHPU   copyir.com 7 Change PRCB   copyir.com 8 Change REDB   copyir.com
C3B04    IH malfunction
• Malfunction occurs in the fusing CPU    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, degaussing coil unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change degaussing coil unit   copyir.com 6 Change IHPU   copyir.com 7 Change PRCB   copyir.com 8 Change REDB   copyir.com
C4101    Polygon motor rotation trouble
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor   copyir.com • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C4301    PH cooling fan motor failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM14 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM14 operation check REYB PH CN4REYB PH-1 (REM) REYB PH CN4REYB PH-3 (LOCK) B-7   copyir.com 4 Change FM14   copyir.com 5 Change REYB/PH   copyir.com 6 Change DCPU   copyir.com
C4501    Laser malfunction
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output   copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C5104    Transfer belt motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M1 connector for proper connection and correct as necessary   copyir.com 2 Check M1 for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M1 operation check PRCB CN13PRCB-3 (REM) PRCB CN13PRCB-6 (LOCK) K-11   copyir.com 5 Change M1   copyir.com 6 Change PRCB   copyir.com
C5105    Transfer belt motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M1 connector for proper connection and correct as necessary   copyir.com 2 Check M1 for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M1 operation check PRCB CN13PRCB-3 (REM) PRCB CN13PRCB-6 (LOCK) K-11   copyir.com 5 Change M1   copyir.com 6 Change PRCB   copyir.com
C5304    IH cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM10 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM10 operation check PRCB CN26PRCB-4 (REM) PRCB CN26PRCB-6 (LOCK) C-16   copyir.com 4 Change FM10   copyir.com 5 Change PRCB   copyir.com
C5305    IH cooling fan motor/2’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM11 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM11 operation check PRCB CN26PRCB-7 (REM) PRCB CN26PRCB-9 (LOCK) C-16   copyir.com 4 Change FM11   copyir.com 5 Change PRCB   copyir.com
C5306    IH cooling fan motor/3’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM12 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM12 operation check PRCB CN26PRCB-10 (REM) PRCB CN26PRCB-12 (LOCK) C-15 to 16   copyir.com 4 Change FM12   copyir.com 5 Change PRCB   copyir.com
C5351    Power supply cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM9 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM9 operation check DCPU PJ8DCPU-3 (LOCK) R to S-28   copyir.com 4 Change FM9   copyir.com 5 Change DCPU   copyir.com 6 Change PRCB   copyir.com
C5354    Ozone ventilation fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM6 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM6 operation check PRCB CN6PRCB-1 (REM) PRCB CN6PRCB-3 (LOCK) K-6 to 7   copyir.com 4 Change FM6   copyir.com 5 Change MFPB   copyir.com
C5356    Cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM3 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM3 operation check PRCB CN10PRCB-1 (REM) PRCB CN10PRCB-3 (LOCK) K-6   copyir.com 4 Change FM3   copyir.com 5 Change MFPB   copyir.com
C5370    MFP control board cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM17 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM17 operation check REYB/SL PJ3REYB/SL-3 (LOCK) L-25   copyir.com 4 Change FM17   copyir.com 5 Change REYB/SL   copyir.com 6 Change MFPB   copyir.com
C5371    MFP control board CPU cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the fan connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 Fan motor operation check MFPB PJ20MFPBL-3 (LOCK) T-26   copyir.com 4 Change MFPB   copyir.com
C6102    Drive system home sensor malfunction
• The scanner home sensor is unable to detect the scanner located at its home position   copyir.com • The scanner home sensor is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance   copyir.com • The scanner home sensor detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor   copyir.com    1 Correct or change the scanner drive (cable, pulley, gear, belt) if it is faulty   copyir.com 2 Correct the scanner motor set screw if loose   copyir.com 3 Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]   copyir.com 4 Check the PS201, M201, REYB/SCAN and IPB connector for proper connection and correct as necessary   copyir.com 5 PS201 I/O check, sensor check IPB CN11IPB-3 (ON) T-15 6 M201 operation check REYB/SCAN CN5REYB/SCAN-4 to 7 Q to R-18   copyir.com 7 Change REYB/SCAN   copyir.com 8 Change IPB   copyir.com
C6103    Slider over running
• The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed   copyir.com    1 Correct or change the scanner drive (cable, pulley, gear, belt) if it is faulty   copyir.com 2 Correct the scanner motor set screw if loose   copyir.com 3 Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]   copyir.com 4 Check the PS201, M201, REYB/SCAN and IPB connector for proper connection and correct as necessary   copyir.com 5 PS201 I/O check, sensor check IPB CN11IPB-3 (ON) T-15 6 M201 operation check REYB/SCAN CN5REYB/SCAN-4 to 7 Q to R-18   copyir.com 7 Change REYB/SCAN   copyir.com 8 Change IPB   copyir.com
C6301    Optical cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM201 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 M202 operation check REYB/SCAN CN2REYB/SCAN-3 (LOCK) Q to R-18   copyir.com 4 Change REYB/SCAN   copyir.com 5 Change IPB   copyir.com
C6704    Image input time out
• Image data is not input from the image processing board (IPB) to the printer control board (PRCB)   copyir.com    1 Select [Service Mode] – [State Confirmation] – [Memory/HDD Adj   copyir.com] – [Memory Bus Check] – [Scanner-Memory], and conduct the memory bus function   copyir.com 2 Check the connectors between IPB and MFPB for proper connection and correct as necessary   copyir.com 3 Change MFPB   copyir.com 4 Change IPB   copyir.com
C6751    CCD clamp/gain adjustment failure
• The adjustment value is 0 or 255 during a CCD clamp adjustment   copyir.com • The peak value of the output data is 64 or less during a CCD gain adjustment   copyir.com    1 Correct the harness connection between CCDB and IPB if faulty   copyir.com 2 Check for possible extraneous light and correct as necessary   copyir.com 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the scanner if faulty, or change scanner   copyir.com 5 Change CCD sensor unit   copyir.com 6 Change IPB   copyir.com
C6F01    Scanner sequence trouble 1
• The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF   copyir.com    1 Correct the harness connection between main body and ADF if faulty   copyir.com 2 Change DFCB   copyir.com 3 Change MFPB   copyir.com
C8101    Before reading pressure welding alienation mechanism
C8102    Turn around pressure welding alienation trouble
C8103    Lift up mechanism trouble
C8104    Glass movement trouble
C8302    Read cooling fan trouble
C9401    Exposure turning on the lamp trouble detection
• The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment   copyir.com    1 Check the connection between the lamp harness and the inverter board, and correct if necessary   copyir.com 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary   copyir.com 3 Check the connection between REYB/ SCAN and IPB, and correct if necessary   copyir.com 4 Check that the connection between CCDB and IPB, and correct if necessary   copyir.com 5 Change INVB   copyir.com 6 Change scanner assy   copyir.com 7 Change IPB   copyir.com 8 Change CCDB   copyir.com 9 Change REYB/SCAN   copyir.com
C9402    Exposure turning on the lamp abnormally detection
• The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job   copyir.com    1 Check the connection between the lamp harness and the inverter board, and correct if necessary   copyir.com 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary   copyir.com 3 Check the connection between REYB/ SCAN and IPB, and correct if necessary   copyir.com 4 Check that the connection between CCDB and IPB, and correct if necessary   copyir.com 5 Change INVB   copyir.com 6 Change scanner assy   copyir.com 7 Change IPB   copyir.com 8 Change CCDB   copyir.com 9 Change REYB/SCAN   copyir.com
CA051    Standard controller configuration failure
• The controller of the printer control board (PRCB) is faulty   copyir.com    1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting]   copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more   copyir.com 2 Check the connectors of the MFP board (MFPB) for proper connection and correct as necessary   copyir.com 3 Change MFPB
CA052    Controller hardware error
• A controller hardware error is detected in the network I/F   copyir.com    1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting]   copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more   copyir.com 2 Check the connectors of the MFP board (MFPB) for proper connection and correct as necessary   copyir.com 3 Change MFPB
CA053    Controller start failure
• A controller start failure is detected in the controller interface   copyir.com    1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting]   copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more   copyir.com 2 Check the connectors of the MFP board (MFPB) for proper connection and correct as necessary   copyir.com 3 Change MFPB
CB001    copyir.com   copyir.com   copyir.com CB119    FAX Board Error
CD004    copyir.com   copyir.com   copyir.com CD011    HDD error
CF001    copyir.com   copyir.com   copyir.com CFF15    MFP Control Board error  

 