شارپ Sharp ARM200
E1-00 IMC PWB communication trouble
An abnormality occurs in communication between the MCU PWB and the IMC PWB copyir copyir.com com IMC PWB-MCU PWB harness abnormality MCU PWB connector disconnection IMC PWB ROM defect/data abnormality
E1-10 IMC PWB trouble
An abnormality occurs in the IMC PWB copyir copyir.com com USB chip error/CODEC error on the IMC PWB
E1-11 IMC ASIC error
An abnormality occurs in the IMC PWB copyir copyir.com com Abnormality in ASIC on the IMC PWB
E1-13 IMC PWB flash ROM error
An abnormality occurs in the IMC flash ROM copyir copyir.com com IMC PWB abnormality
E1-16 IMC PWB DIMM memory read/write check error
An installation error occurs in the IMC expansion compression memory module copyir copyir.com com An error occurs during access to the IMC expansion compression memory copyir copyir.com com Improper installation of the IMC expansion memory module copyir copyir.com com IMC expansion memory module abnormality IMC expansion memory contact abnormality IMC PWB abnormality copyir copyir.com com
E1-81 Interface error (Parity) in communication with the IMC PWB
A parity error occurs in communication between the MCU PWB and the IMC PWB copyir copyir.com com IMC PWB-MCU PWB harness defect Improper connection of the MCU PWB connector IMC PWB ROM defect/data abnormality”
E1-82 Interface error (Overrun) in communication with the IMC PWB
An overrun error occurs in communication between the MCU PWB and the IMC PWB copyir copyir.com com IMC PWB-MCU PWB harness defect Improper connection of the MCU PWB connector IMC PWB ROM defect/data abnormality copyir copyir.com com
E1-84 Interface error (Framing) in communication with the IMC PWB
A framing error occurs in communication between the MCU PWB and the IMC PWB copyir copyir.com com IMC PWB-MCU PWB harness defect Improper connection of the MCU PWB connector IMC PWB ROM defect/data abnormality copyir copyir.com com
E7-01 Duplex model memory error
The memory capacity for the duplex model machine is improper copyir copyir.com com Insufficient memory capacity The memory capacity of the MCU PWB is improper copyir copyir.com com
E7-02 LSU trouble
The BD signal from the LSU cannot be detected in a certain cycle copyir copyir.com com (Always OFF or always ON) LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated copyir copyir.com com MCU PWB abnormality copyir copyir.com com
E7-10 Shading trouble (Black correction)
The CCD black scan level is abnormal when the shading copyir copyir.com com Improper connection of the CCD unit flat cable CCD unit abnormality MCU PWB abnormality copyir copyir.com com
E7-11 Shading trouble (White correction)
The CCD white scan level is abnormal when the shading copyir copyir.com com Improper connection of the CCD unit flat cable Dirt on the mirror, the lens, and the reference white plate Copy lamp lighting abnormality CCD unit abnormality MCU PWB abnormality (When occurred in the SPF scan position copyir copyir.com com ) Improper installation of the mirror unit
E7-12 Shading trouble
White correction is not completed in the specified number of operations copyir copyir.com com CCD unit flat cable connection failure copyir copyir.com com Dirt on mirrors, lenses, and the reference white plate copyir copyir.com com Copy lamp lighting abnormality CCD unit abnormality MCU PWB abnormality
E7-16 Abnormal laser output
When the laser output is stopped, HSYNC is detected copyir copyir.com com Laser abnormality MCU PWB abnormality copyir copyir.com com
F2-04 Improper cartridge (Destination error, life cycle error)
The destination of the machine differs from that of the CRUM copyir copyir.com com The life cycle information is other than “Not used (FFh) copyir copyir.com com ” CRUM chip defect Improper developing unit
F5-02 Copy lamp lighting abnormality
The copy lamp does not turn on copyir copyir.com com Copy lamp abnormality Copy lamp harness abnormality CCD PWB harness abnormality copyir copyir.com com
F6-00 FAX board communication trouble copyir copyir.com com No command can be sent from the MCU to the FAX copyir copyir.com com
F6-10 FAX board trouble copyir copyir.com com FAX controller and FAX board memory abnormality copyir copyir.com com
F6-80 FAX board communication trouble (Protocol) copyir copyir.com com
A break error occurs in communication between the MCU and the FAX board copyir copyir.com com MCU PWB connector connection failure/ Garbled data copyir copyir.com com
F6-81 FAX board communication trouble (Parity) copyir copyir.com com
A parity error occurs in communication copyir copyir.com com between the MCU and the FAX board copyir copyir.com com MCU PWB connector connection failure/ Garbled data copyir copyir.com com
F6-82 FAX board communication trouble (Overrun) copyir copyir.com com
An overrun error occurs in communication between the MCU and the FAX board copyir copyir.com com MCU PWB connector connection failure/ Garbled data
F6-84 FAX board communication trouble (Framing) copyir copyir.com com
A framing error occurs in communication between the MCU and the FAX board copyir copyir.com com MCU PWB connector connection failure/ Garbled data copyir copyir.com com
F6-88 FAX board communication trouble (Time out) copyir copyir.com com
FAX board communication error copyir copyir.com com There is no respond command from the FAX for 30sec or more copyir copyir.com com
F6-99 Machine – FAX language error copyir copyir.com com
Discrepancy of the destination of the machine and the FAX board copyir copyir.com com The destination of the machine differs from that of the FAX board copyir copyir.com com
F9-00 AR-NB3 board communication trouble copyir copyir.com com
AR-NB3 print data reception error copyir copyir.com com Print data cannot be received from the AR-NB3 for 3 min or more copyir copyir.com com
H2-00 Thermistor open
The thermistor is open copyir copyir.com com The fusing unit is not installed copyir copyir.com com Thermistor abnormality Control PWB abnormality Fusing section connector disconnection The fusing unit is not installed copyir copyir.com com
H3-00 Heat roller high temperature detection
The fusing temperature exceeds 240C° copyir copyir.com com Thermistor abnormality Control PWB abnormality Fusing section connector disconnection copyir copyir.com com
H4-00 Heat roller low temperature detection
When the fusing temperature is lower than 150C° after 55sec from the start of warming up copyir copyir.com com When the warming up complete temperature is not reached in 30sec from reaching 150C° copyir copyir.com com When the fusing temperature is lower than 100C° after 20sec from ready start copyir copyir.com com When the fusing temperature is lower than 145C° when printing copyir copyir.com com ” Thermistor abnormality Heater lamp abnormality Thermostat abnormality Control PWB abnormality
H5-01 5-time continuous detections of POUT notreached jam copyir copyir.com com
Paper not-reached jams are detected 5 times or more continuously by the paper exit sensor (POUT) copyir copyir.com com The jam counter is backed up and used for jobs after turning on the power copyir copyir.com com A fusing jam is not canceled completely copyir copyir.com com (A jam paper remains in the machine copyir copyir.com com ) Paper exit sensor trouble or harness connection trouble Defective installation of the fusing unit copyir copyir.com com
L1-00 Scanner feed trouble
The scanner does not complete feeding in the specified time copyir copyir.com com Mirror unit abnormality The scanner wire is disconnected copyir copyir.com com The origin detection sensor abnormality Mirror motor harness abnormality
L3-00 Scanner return trouble
The scanner does not complete returning in the specified time copyir copyir.com com The mirror is not in the home position when OC copying is started with the mirror standby in the home position copyir copyir.com com Mirror unit abnormality Scanner wire disconnection Origin detection sensor abnormality Mirror motor harness abnormality
L4-01 Main motor lock detection
The main motor does not rotate copyir copyir.com com The motor lock signal is detected for 1sec or more after rotation of the main motor copyir copyir.com com The motor lock signal is detected for 1sec during rotation of the main motor copyir copyir.com com Main motor unit abnormality Improper connection or disconnection the main motor and the harness copyir copyir.com com MCU PWB abnormality
L4-11 Shifter motor trouble
The shifter home position detection signal is not detected when initializing the shifter copyir copyir.com com Shifter motor abnormality, improper connection or disconnection of the harness, shifter home position sensor abnormality
L6-10 Polygon motor lock detection
The polygon motor does not rotate copyir copyir.com com The motor lock signal is detected for 6sec after rotation of the polygon motor copyir copyir.com com The motor lock signal is detected for 1sec during rotation of the polygon motor copyir copyir.com com Polygon motor unit abnormality Improper connection or disconnection of the polygon motor and the harness copyir copyir.com com MCU PWB abnormality
L8-01 No full wave signal
The zero cross signal is not detected copyir copyir.com com Power unit abnormality MCU PWB abnormality
U1-03 FAX board battery error copyir copyir.com com
FAX board backup battery error copyir copyir.com com The voltage of the backup battery of SRAM which is installed to the FAX board falls below a certain level copyir copyir.com com
U2-04 EEPROM read/write error (Serial communication error)
EEPROM access process error EEPROM abnormality
U2-11 Counter check sum error (EEPROM)
Check sum error of the counter area in the EEPROM EEPROM abnormality
U2-40 CRUM chip communication error
An error occurs during communication between the MCU and the CRUM chip copyir copyir.com com CRUM chip abnormality Developing unit disconnection MCU PWB abnormality
U9-00 Panel board communication trouble copyir copyir.com com
Communication trouble with the panel board copyir copyir.com com No command can be sent from the MCU to the panel copyir copyir.com com
U9-80 Panel board communication trouble (Protocol) copyir copyir.com com
An error occurs in communication between MCU -Panel PWB copyir copyir.com com MCU PWB – Panel PWB harness trouble/ Garbled data copyir copyir.com com
U9-81 Panel board communication trouble (Parity) copyir copyir.com com
A parity error occurs in communication between the MCU and the Panel PWB copyir copyir.com com MCU PWB – Panel PWB harness trouble/ Garbled data copyir copyir.com com
U9-82 Panel board communication trouble (Overrun) copyir copyir.com com
An overrun error occurs in communication between the MCU and the panel board copyir copyir.com com MCU PWB – Panel PWB harness trouble/ Garbled data copyir copyir.com com
U9-84 Panel board communication trouble (Framing) copyir copyir.com com
A framing error occurs in communication between the MCU and the Panel PWB copyir copyir.com com MCU PWB – Panel PWB harness trouble/ Garbled data copyir copyir.com com
U9-88 Panel board communication trouble (Time out) copyir copyir.com com
A time-out error occurs in communication between the MCU and the Panel PWB copyir copyir.com com A command is completely sent from the MCU to the panel copyir copyir.com com
U9-99 Panel language error copyir copyir.com com
Language discrepancy error copyir copyir.com com Discrepancy between the machine language and the panel language copyir copyir.com com