A0-01    PCU PWB ROM error    The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc  copyir.com ROM trouble  copyir.com    Use SIM49-1 to perform the version-up procedure again  copyir.com ROM trouble  copyir.com
A0-02    SCU PWB ROM error    The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc  copyir.com ROM trouble  copyir.com    Use SIM49-1 to perform the version-up procedure again  copyir.com ROM trouble  copyir.com
A0-10    MFP PWB ROM error    Firmware combination error between the MFP and the image ROM (color correction ROM)  copyir.com    Upgrade the firmware versions of the MFP and the image ROM (color correction ROM)  copyir.com
A0-11    Firmware version inconsistency (MFP – PCU)    Firmware combination error between the MFP and the PCU  copyir.com    Check the combination between the MFP and the PCU  copyir.com
A0-12    Firmware version inconsistency (MFP – SCU)    Firmware combination error between the MFP and the SCU  copyir.com    Check the combination between the MFP and the SCU  copyir.com
A0-20    MFP firmware version and EEPROM data version inconsistency    Inconsistency between the MFP firmware version and the EEPROM data version  copyir.com    Check the combination of the firmware  copyir.com
A0-21    PCU firmware version and EEPROM data version inconsistency    Inconsistency between the PCU firmware version and the EEPROM data version  copyir.com    Check the combination of the firmware  copyir.com
A0-22    SCU firmware version and EEPROM data version inconsistency    Inconsistency between the SCU firmware version and the EEPROM data version  copyir.com    Check the combination of the firmware  copyir.com
C1-10    Main charger trouble (BK)    The main charger unit (BK) is not installed properly  copyir.com There is an abnormality in the main charger unit  copyir.com Disconnection of the high voltage PWB connector  copyir.com Breakage of the high voltage harness  copyir.com MC/DV PWB trouble  copyir.com PCU PWB trouble    Check the output of the main charger with SIM8-2  copyir.com Check disconnection of the main charger  copyir.com/Replace  copyir.com Check disconnection of the high voltage PWB  copyir.com connector  copyir.com /Replace  copyir.com Replace the MC/DV PWB  copyir.com Replace the PCU PWB  copyir.com
C1-14    Main charger trouble (Color)    The main charger unit (CMY) is not installed properly  copyir.com There is an abnormality in the main charger  copyir.com Disconnection of the high voltage PWB connector  copyir.com Breakage of the high voltage harness  copyir.com MC PWB trouble  copyir.com PCU PWB trouble    Check the output of the main charger with SIM8-2  copyir.com Check disconnection of the main charger  copyir.com/Replace  copyir.com Check disconnection of the high voltage PWB connector  copyir.com /Replace  copyir.com Replace the MC PWB  copyir.com Replace the PCU PWB  copyir.com
C4-00    PTC trouble    The PTC unit is not properly installed  copyir.com PTC unit trouble  copyir.com TC PWB trouble  copyir.com PCU PWB trouble  copyir.com Connector, harness connection trouble  copyir.com    Replace the PTC unit  copyir.com Replace the secondary transfer PWB  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
E7-01    MFP image data error    Image data transfer error in the MFP PWB  copyir.com MFP PWB trouble  copyir.com    Check connection of the connector and the harness of the MFP PWB  copyir.com Replace the MFP PWB  copyir.com
E7-03    HDD trouble    Connector, harness connection trouble in the MFP PWB and HDD  copyir.com HDD (error file management area) data abnormality (FAT breakage)  copyir.com MFP PWB trouble  copyir.com    Check connection of the connector and the harness of the MFP PWB and HDD  copyir.com Use SIM62-2, 3 to check read/write operations of the HDD  copyir.com Replace the HDD  copyir.com Replace the MFP PWB  copyir.com
E7-04    HDD-ASIC error    HDD-ASIC trouble  copyir.com An error occurs in the HDD-ASIC self test when booting  copyir.com    Replace the MFP PWB  copyir.com
E7-05    Standard memory/expansion memory read/write error (MFP PWB)    Improper insertion of the memory  copyir.com Garbled memory data  copyir.com The memory capacity is not the specified level  copyir.com    Check insertion of the memory  copyir.com Use SIM60-1 to check the read/write operations of the memory  copyir.com Replace the expansion memory  copyir.com Replace the MFP PWB  copyir.com
E7-06    Image data decode error    Compressed image data abnormality  copyir.com HDD connection trouble when HDD is installed  copyir.com Image data compression/transfer data garble  copyir.com MFP PWB trouble  copyir.com    If the job at an occurrence of an error is a FAX job, check the FAX PWB  copyir.com Check connection of the MFPC PWB and the HDD  copyir.com Replace the MFPC PWB  copyir.com
E7-08    MFP memory compatibility error (MFP PWB)    A DIMM of different specifications is installed to the MFP memory slot  copyir.com DIMM trouble  copyir.com    Check the installed DIMM  copyir.com Replace the DIMM  copyir.com
E7-09    Standard memory size/Expansion memory size error (MFP PWB)    A DIMM other than below is installed to the default throttle  copyir.com • 38-sheet machine/40-sheet machine System memory: 1GB Local memory: 512MB • 31-sheet machine System memory: 512MB Local memory: 512MB DIMM trouble  copyir.com Insufficient memory size  copyir.com    Replace the DIMM  copyir.com
E7-10    Shading error (Black correction)    Abnormality in the CCD black scan level when the scanner lamp is turned OFF  copyir.com Improper installation of the harness to the CCD unit/SCU PWB  copyir.com CCD unit abnormality  copyir.com SCU PWB abnormality  copyir.com    Check connection of the harness to the CCD unit/ SCU PWB  copyir.com Check the CCD unit  copyir.com Check the SCU PWB  copyir.com
E7-11    Shading error (White correction)    Abnormality in the CCD white reference plate scan level when the scanner lamp is turned ON  copyir.com Improper installation of the harness to the CCD unit/SCU PWB  copyir.com Dirt on the mirror, lens, and the reference white plate  copyir.com Scanner lamp lighting trouble  copyir.com CCD unit abnormality  copyir.com SCU PWB abnormality  copyir.com    Check connection of the harness to the CCD unit/ SCU PWB  copyir.com Check connection of the harness to the scanner lamp unit  copyir.com Clean the mirror, the lens, and the reference white plate  copyir.com Check the CCD unit  copyir.com Check the SCU PWB  copyir.com
E7-14    CCD-ASIC error    SCU PWB trouble  copyir.com    Check the SCU PWB  copyir.com Replace the SCU PWB  copyir.com
E7-20    LSU laser detection error (K)    Optical axis shift  copyir.com Reduced laser power, lighting error, laser diode trouble  copyir.com BD PWB trouble  copyir.com Harness and connector trouble between the LD/BD PWB and the LSU cnt PWB  copyir.com    Use SIM61-1 to check the operation of the LSU  copyir.com Check the PWB and connection of the harness in the LSU  copyir.com Replace the LSU  copyir.com
E7-21    LSU laser detection error (C)    Reduced laser power, lighting error, laser diode trouble  copyir.com Harness and connector trouble between the LD PWB and the LSU cnt PWB  copyir.com    Use SIM61-1 to check the operation of the LSU  copyir.com Check the PWB and connection of the harness in the LSU  copyir.com Replace the LSU  copyir.comcnt PWB  copyir.com
E7-22    LSU laser detection error (M)    Reduced laser power, lighting error, laser diode trouble  copyir.com Harness and connector trouble between the LD PWB and the LSU cnt PWB  copyir.com    Use SIM61-1 to check the operation of the LSU  copyir.com Check the PWB and connection of the harness in the LSU  copyir.com Replace the LSU  copyir.com
E7-23    LSU laser detection error (Y)    Reduced laser power, lighting error, laser diode trouble  copyir.com Harness and connector trouble between the LD PWB and the LSU cnt PWB  copyir.com    Use SIM61-1 to check the operation of the LSU  copyir.com Check the PWB and connection of the harness in the LSU  copyir.com Replace the LSU  copyir.com
E7-28    LSU-PCU connection error    Communication error between the CPU in the PCU PWB and the control ASIC  copyir.com Improper connection of the communication connector between the PCU PWB and the LSU cnt PWB (interface PWB)  copyir.com Harness trouble between the PCU PWB and the LSU cnt PWB (interface PWB) PCU PWB or LSU cnt PWB (interface PWB) trouble    Check connection of the connector and the harness between the PCU PWB and the LSU cnt PWB (interface PWB)  copyir.com Replace the LSU cnt PWB  copyir.com Replace the PCU PWB  copyir.com
E7-29    LSU ASIC frequency error    Oscillation abnormality of the external oscillator and the internal oscillating circuit used in the LSU ASIC  copyir.com LSU ASIC abnormality on the LSU ASIC PWB  copyir.com    Replace the LSU cnt PWB  copyir.com
E7-50    Engine connection trouble    A PWB, or firmware, or LSU which is not supported by the machine specifications is detected in the PCU PWB  copyir.com PCU PWB trouble  copyir.com LSU trouble  copyir.com    Check the kind and the version of the firmware  copyir.com Check the LSU, and replace it if necessary  copyir.com Check the PCU PWB, and replace it if necessary  copyir.com
E7-55    PWB information sum error (Engine detection)    PCU EEPROM sum check error  copyir.com PCU EEPROM trouble  copyir.com PCU EEPROM contact trouble  copyir.com Malfunction due to noises    Replace the PCU PWB  copyir.com Replace the PCU EEPROM  copyir.com
E7-60    Combination error between the MFP PWB and other PWB, firmware    A PWB or firmware which is not supported by the machine specifications is detected in the MFP PWB  copyir.com MFP PWB trouble  copyir.com The PWB/firmware which is not supported by the machine specifications is connected  copyir.com    Check the kind and the version of the firmware  copyir.com Check the MFP PWB, and replace it if necessary  copyir.com
E7-61    Combination error between the MFP PWB and the PCU PWB    Combination error between the MFP PWB and the PCU PWB  copyir.com MFP PWB trouble  copyir.com PCU PWB trouble  copyir.com    Check the combination between the MFP PWB and the PCU PWB  copyir.com Replace the MFP PWB  copyir.com Replace the PCU PWB  copyir.com
E7-65    MFP EEPROM sum check error    MFP PWB EEPROM device breakdown  copyir.com Contact trouble of the MFP EEPROM device  copyir.com Malfunction due to noises  copyir.com    Replace the MFP PWB  copyir.com Replace the MFP PWB EEPROM  copyir.com
E7-80    MFP-SCU PWB communication error    SCU PWB connector connection trouble  copyir.com SCU PWB – MFP PWB connection trouble  copyir.com SCU PWB mother board connection trouble  copyir.com SCU PWB trouble  copyir.com MFP PWB trouble  copyir.com Replace the mother board  copyir.com    Check connection of the SCU PWB, the MFP PWB, and the mother board  copyir.com Check the earth line  copyir.com Replace the SCU PWB  copyir.com Replace the MFP PWB  copyir.com Replace the mother board  copyir.com
E7-90    MFP-PCU PWB communication error    PCU PWB connector connection trouble  copyir.com PCU PWB – MFP PWB connection trouble  copyir.com PCU PWB motherboard connection trouble  copyir.com PCU PWB trouble  copyir.com MFP PWB trouble  copyir.com Replace the mother board  copyir.com    Check connection of the PCU PWB, the MFP PWB, and the mother board  copyir.com Check the earth line  copyir.com Replace the PCU PWB  copyir.com Replace the MFP PWB  copyir.com Replace the mother board  copyir.com
EE-EC    Automatic toner density adjustment error (Sampling level 76 – 117/139 – 178)    Toner density sensor trouble  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner density sensor  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
EE-EL    Automatic toner density adjustment error (Overtoner)    Toner density sensor trouble  copyir.com Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner density sensor  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
EE-EU    Automatic toner density adjustment error (Undertoner)    Toner density sensor trouble  copyir.com Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner density sensor  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
F1-00    Finisher – PCU PWB communication error    Connection trouble of the connector and the harness between the finisher and the PCU PWB  copyir.com Finisher control PWB trouble  copyir.com PCU PWB trouble  copyir.com Strong external noises  copyir.com    Check the connector and the harness between the finisher and the PCU PWB  copyir.com Replace the finisher control PWB  copyir.com Replace the PCU PWB  copyir.com
F1-03    Finisher paper exit roller lifting operation trouble    Finisher paper exit roller lift motor trouble  copyir.com Harness and connector connection trouble  copyir.com Home position sensor trouble  copyir.com Finisher control PWB trouble  copyir.com    Use SIM3-3 to check the operation of the paper exit roller lift motor  copyir.com Replace the paper exit roller lift motor  copyir.com Check connection of the connector and the harness  copyir.com Replace the home position sensor  copyir.com Replace the finisher control PWB  copyir.com
F1-10    Staple operation trouble    Staple motor trouble  copyir.com Finisher control PWB trouble  copyir.com Home position sensor trouble  copyir.com    Use SIM3-3 to check the operation of the staple motor  copyir.com Replace the staple motor  copyir.com Check connection of the connector and the harness  copyir.com Replace the home position sensor  copyir.com Replace the finisher control PWB  copyir.com
F1-15    Finisher paper exit tray lift operation trouble    Paper exit tray lift motor trouble  copyir.com Finisher control PWB trouble  copyir.com    Use SIM3-3 to check the operation of the paper exit tray lift motor  copyir.com Replace the finisher control PWB  copyir.com Replace the paper exit tray lift motor  copyir.com
F1-19    Finisher alignment operation trouble F    Finisher paper alignment motor lock  copyir.com Motor speed abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com    Use SIM3-3 to check the operation of the paper alignment motor F  copyir.com Replace the finisher control PWB  copyir.com Replace the paper alignment motor F  copyir.com
F1-20    Finisher alignment operation trouble R    Finisher paper alignment motor lock  copyir.com Motor speed abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com    Use SIM3-3 to check the operation of the paper alignment motor R  copyir.com Replace the finisher control PWB  copyir.com Replace the paper alignment motor R  copyir.com
F1-21    Finisher fan trouble    Finisher fan motor trouble  copyir.com Finisher control PWB trouble  copyir.com Harness and connector connection trouble  copyir.com    Use SIM3-3 to check the operation of the fan motor  copyir.com Check connection between the finisher control PWB and the fan  copyir.com Replace the fan  copyir.com Replace the finisher control PWB  copyir.com
F1-29    Finisher PWB fan trouble    Finisher PWB fan lock  copyir.com Finisher control PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM 3-3 to check the operation of the control PWB cooling fan (FBCF)  copyir.com Replace the finisher PWB fan  copyir.com Replace the finisher control PWB  copyir.com Connection trouble of the connector and the harness  copyir.com
F1-37    Finisher data backup RAM error    Finisher control PWB trouble  copyir.com Malfunction due to noises    Replace the finisher control PWB  copyir.com Readjust the finisher  copyir.com (Use SIM3-10,Finisher control PWB DIP SW adjustment  copyir.com)
F1-50    Main unit – Finisher combination error    The finisher which is not supported by the main unit model is installed  copyir.com Finisher control PWB trouble  copyir.com    Install a proper finisher  copyir.com Replace the finisher control PWB  copyir.com
F2-11    Developing unit initial detection (K)    The initial detection fuse is not blown off though it is conducted for the specified time  copyir.com (K) Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-51 to check the operation of the [DVCRU K] fuse blowing circuit  copyir.com Use SIM30-1 to check the [DVCRU K] initial detection input signal  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-12    Developing unit initial detection (C)    The initial detection fuse is not blown off though it is conducted for the specified time  copyir.com (C) Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-51 to check the operations of the [DVCRU C] fuse blowing circuit  copyir.com Use SIM30-1 to check the [DVCRU C] initial detection input signal  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-13    Developing unit initial detection (M)    The initial detection fuse is not blown off though it is conducted for the specified time  copyir.com (M) Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-51 to check the operations of the [DVCRU M] fuse blowing circuit  copyir.com Use SIM30-1 to check the [DVCRU M] initial detection input signal  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-14    Developing unit initial detection (Y)    The initial detection fuse is not blown off though it is conducted for the specified time  copyir.com (Y) Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-51 to check the operations of the [DVCRU Y] fuse blowing circuit  copyir.com Use SIM30-1 to check the [DVCRU Y] initial detection input signal  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-15    Drum unit initial detection trouble (K drum)    When the newly installed drum is driven for the specified time after installation, the new state is not canceled  copyir.com (K) Detection switch [DRCRU-K] trouble Process cartridge trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM30-1 to check the operation of the [DRCRU-K] switch  copyir.com Replace the process (drum) cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-16    Drum unit initial detection trouble (C drum)    When the newly installed drum is driven for the specified time after installation, the new state is not canceled  copyir.com (C) Detection switch [DRCRU-C] trouble Process cartridge trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM30-1 to check the operation of the [DRCRU-C] switch  copyir.com Replace the process (drum) cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-17    Drum unit initial detection trouble (M drum)    When the newly installed drum is driven for the specified time after installation, the new state is not canceled  copyir.com (M) Detection switch [DRCRU-M] trouble Process cartridge trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM30-1 to check the operation of the [DRCRU-M] switch  copyir.com Replace the process (drum) cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-18    Drum unit initial detection trouble (Y drum)    When the newly installed drum is driven for the specified time after installation, the new state is not canceled  copyir.com (Y) Detection switch [DRCRU-Y] trouble Process cartridge trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM30-1 to check the operation of the [DRCRU-Y] switch  copyir.com Replace the process (drum) cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-19    Primary transfer unit initial detection trouble    When the newly installed primary transfer unit is driven for the specified time after installation, the new state is not canceled  copyir.com 1TUD K sensor trouble Primary transfer initial operation clutch mechanism trouble Primary transfer unit initial detection level trouble PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Primary transfer belt unit trouble  copyir.com    Use SIM30-1 to check the operation of the 1TUD-K sensor  copyir.com Use SIM6-3 to check the switching operation of the primary transfer unit  copyir.com Check to confirm that the initial detection level is inclined  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com Replace the primary transfer unit  copyir.com
F2-21    Secondary transfer unit initial detection trouble    When the newly installed secondary transfer unit is driven for the specified time after installation, the new state is not canceled  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Secondary transfer UN initial detection mechanism trouble Initial detection electrode trouble Secondary transfer unit trouble  copyir.com    Check conduction of the initial detection electrode plate and the initial detection GND electrode plate  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com Replace the secondary transfer unit  copyir.com
F2-22    Discharge lamp trouble (K)    Contact trouble between the discharge lamp PWB (K) and the PCU PWB  copyir.com Discharge lamp PWB (K) trouble  copyir.com PCU PWB trouble  copyir.com    Replace the discharge lamp PWB (K)  copyir.com Check the harness and the connector  copyir.com Replace the PCU PWB  copyir.com
F2-23    Discharge lamp trouble (C)    Contact trouble between the discharge lamp PWB (C) and the PCU PWB  copyir.com Discharge lamp PWB (C) trouble  copyir.com PCU PWB trouble  copyir.com    Replace the discharge lamp PWB (C)  copyir.com Check the harness and the connector  copyir.com Replace the PCU PWB  copyir.com
F2-24    Discharge lamp trouble (M)    Contact trouble between the discharge lamp PWB (M) and the PCU PWB  copyir.com Discharge lamp PWB (M) trouble  copyir.com PCU PWB trouble  copyir.com    Replace the discharge lamp PWB (M)  copyir.com Check the harness and the connector  copyir.com Replace the PCU PWB  copyir.com
F2-25    Discharge lamp trouble (Y)    Contact trouble between the discharge lamp PWB (Y) and the PCU PWB  copyir.com Discharge lamp PWB (Y) trouble  copyir.com PCU PWB trouble  copyir.com    Replace the discharge lamp PWB (Y)  copyir.com Check the harness and the connector  copyir.com Replace the PCU PWB  copyir.com
F2-26    Auto toner density control level setting trouble (K)    The toner density sample level is not in the specified range when the automatic toner density control level is set  copyir.com (K) Toner density sensor trouble  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    When the power is turned OFF/ON, the automatic developer adjustment is executed again  copyir.com Replace the developer cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-27    Auto toner density control level setting trouble (C)    The toner density sample level is not in the specified range when the automatic toner density control level is set  copyir.com (C) Toner density sensor trouble  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    When the power is turned OFF/ON, the automatic developer adjustment is executed again  copyir.com Replace the developer cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-28    Auto toner density control level setting trouble (M)    The toner density sample level is not in the specified range when the automatic toner density control level is set  copyir.com (M) Toner density sensor trouble  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    When the power is turned OFF/ON, the automatic developer adjustment is executed again  copyir.com Replace the developer cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-29    Auto toner density control level setting trouble (Y)    The toner density sample level is not in the specified range when the automatic toner density control level is set  copyir.com (Y) Toner density sensor trouble  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    When the power is turned OFF/ON, the automatic developer adjustment is executed again  copyir.com Replace the developer cartridge  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
F2-39    Process thermister trouble    Process thermister trouble  copyir.com Process thermister harness connection trouble  copyir.com PCU PWB trouble    Replace the process thermister  copyir.com Check connection of the harness and the connector  copyir.com Replace the PCU PWB  copyir.com
F2-40    Toner density sensor trouble (BLACK)    Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness  copyir.com Developing unit trouble  copyir.com PCU PWB trouble    Replace the toner density sensor  copyir.com Harness and connector connection trouble  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
F2-41    Toner density sensor trouble (CYAN)    Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness  copyir.com Developing unit trouble  copyir.com PCU PWB trouble    Replace the toner density sensor  copyir.com Harness and connector connection trouble  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
F2-42    Toner density sensor trouble (MAGENTA)    Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness  copyir.com Developing unit trouble  copyir.com PCU PWB trouble    Replace the toner density sensor  copyir.com Harness and connector connection trouble  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
F2-43    Toner density sensor trouble (YELLOW)    Toner density sensor output abnormality (Sample level 25 or less, or 231 or above)  copyir.com Connection trouble of the connector and the harness  copyir.com Developing unit trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner density sensor  copyir.com Harness and connector connection trouble  copyir.com Replace the developing unit  copyir.com Replace the PCU PWB  copyir.com
F2-45    K image density sensor trouble    K image density sensor sensitivity adjustment trouble  copyir.com K image density sensor trouble  copyir.com Harness and connector connection trouble  copyir.com K image density sensor dirt  copyir.com Calibration plate dirt  copyir.com Calibration plate solenoid trouble  copyir.com PCU PWB trouble  copyir.com    Replace the K image density sensor  copyir.com Check connection of the connectors and the harness  copyir.com Clean the K image density sensor  copyir.com Replace the calibration plate  copyir.com Replace the calibration plate solenoid  copyir.com Replace the PCU PWB  copyir.com Use SIM44-2 to adjust the process control sensor sensitivity  copyir.com
F2-49    LSU thermister trouble    The LSU detection temperature is outside of -28  copyir.com  copyir.comC – 78  copyir.com  copyir.comC  copyir.com LSU thermister trouble  copyir.com Harness and connector connection trouble  copyir.com PCU PWB trouble LSU control PWB trouble    Replace the LSU thermister  copyir.com Check connection of the connectors and the harness  copyir.com Replace the PCU PWB  copyir.com Replace the LSU control PWB  copyir.com Replace the LSU  copyir.com
F2-50    K drum phase sensor trouble    Drum phase sensor trouble  copyir.com Harness and connector connection trouble  copyir.com Drum drive section trouble  copyir.com PCU PWB trouble    Use SIM30-1 to check the operation of “DHPD_K  copyir.com”  copyir.com Replace the drum phase sensor  copyir.com Check connection of the connectors and the harness  copyir.com Repair the drum drive section  copyir.com Replace the PCU PWB  copyir.com
F2-51    CL drum phase sensor trouble    Drum phase sensor trouble  copyir.com (DHPCL) Harness and connector connection trouble  copyir.com Drum drive section trouble  copyir.com PCU PWB trouble  copyir.com    Use SIM30-1 to check the operation of “DHPD_CL”  copyir.com Replace the drum phase sensor  copyir.com Check connection of the connectors and the harness  copyir.com Repair the drum drive section  copyir.com Replace the PCU PWB  copyir.com
F2-58    Process humidity sensor trouble    Process humidity sensor trouble  copyir.com Harness and connector connection trouble  copyir.com PCU PWB trouble  copyir.com    Replace the process humidity sensor  copyir.com Check connection of the connectors and the harness  copyir.com Replace the PCU PWB  copyir.com
F2-64    Toner supply operation trouble (BK)    Toner motor trouble  copyir.com Toner density sensor trouble  copyir.com Connector/harness trouble  copyir.com PCU PWB trouble  copyir.com Toner cartridge trouble  copyir.com Developing unit trouble  copyir.com    Replace the toner motor  copyir.com Replace the toner density sensor  copyir.com Connector/harness trouble  copyir.com Replace the PCU PWB  copyir.com Replace the toner cartridge  copyir.com Replace the developing unit  copyir.com
F2-65    Toner supply operation trouble (C)    Toner motor trouble  copyir.com Toner density sensor trouble  copyir.com Connector/harness trouble  copyir.com PCU PWB trouble Toner cartridge trouble  copyir.com Developing unit trouble  copyir.com    Replace the toner motor  copyir.com Replace the toner density sensor  copyir.com Connector/harness trouble  copyir.com Replace the PCU PWB  copyir.com Replace the toner cartridge  copyir.com Replace the developing unit  copyir.com
F2-66    Toner supply operation trouble (M)    Toner motor trouble  copyir.com Toner density sensor trouble  copyir.com Connector/harness trouble  copyir.com PCU PWB trouble Toner cartridge trouble  copyir.com Developing unit trouble  copyir.com    Replace the toner motor  copyir.com Replace the toner density sensor  copyir.com Connector/harness trouble  copyir.com Replace the PCU PWB  copyir.com Replace the toner cartridge  copyir.com Replace the developing unit  copyir.com
F2-67    Toner supply operation trouble (Y)    Toner motor trouble  copyir.com Toner density sensor trouble  copyir.com Connector/harness trouble  copyir.com PCU PWB trouble Toner cartridge trouble  copyir.com Developing unit trouble  copyir.com    Replace the toner motor  copyir.com Replace the toner density sensor  copyir.com Connector/harness trouble  copyir.com Replace the PCU PWB  copyir.com Replace the toner cartridge  copyir.com Replace the developing unit  copyir.com
F2-70    Improper toner cartridge detection (BLACK)    An improper toner cartridge is inserted  copyir.com (The main unit detects a toner cartridge of a different specification  copyir.com) Toner cartridge trouble  copyir.com PCU PWB trouble    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com
F2-71    Improper toner cartridge detection (CYAN)    An improper toner cartridge is inserted  copyir.com (The main unit detects a toner cartridge of a different specification  copyir.com) Toner cartridge trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com
F2-72    Improper toner cartridge detection (MAGENTA)    An improper toner cartridge is inserted  copyir.com (The main unit detects a toner cartridge of a different specification  copyir.com) Toner cartridge trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com
F2-73    Improper toner cartridge detection (YELLOW)    An improper toner cartridge is inserted  copyir.com (The main unit detects a toner cartridge of a different specification  copyir.com) Toner cartridge trouble  copyir.com PCU PWB trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com
F2-74    Toner cartridge CRUM error (BLACK)    Toner cartridge (CRUM) trouble  copyir.com PCU PWB trouble  copyir.com Connector/harness trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com Connector/harness trouble  copyir.com
F2-75    Toner cartridge CRUM error (CYAN)    Toner cartridge (CRUM) trouble  copyir.com PCU PWB trouble  copyir.com Connector/harness trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com Connector/harness trouble  copyir.com
F2-76    Toner cartridge CRUM error (MAGENTA)    Toner cartridge (CRUM) trouble  copyir.com PCU PWB trouble  copyir.com Connector/harness trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com Connector/harness trouble  copyir.com
F2-77    Toner cartridge CRUM error (YELLOW)    Toner cartridge (CRUM) trouble  copyir.com PCU PWB trouble  copyir.com Connector/harness trouble  copyir.com    Replace the toner cartridge  copyir.com Replace the PCU PWB  copyir.com Connector/harness trouble  copyir.com
F2-78    Registration image density sensor trouble (Transfer belt substrate reflection rate abnormality)    Image density (registration) sensor trouble (Sensor sensitivity adjustment trouble)  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Image density (registration) sensor dirt  copyir.com Transfer belt dirt, scratch  copyir.com    Replace the image density (registration) sensor  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Clean the image density (registration) sensor  copyir.com Clean or replace the transfer belt  copyir.com
F3-12    Paper feed tray 1 lift operation trouble    LUD1 is not turned ON within the specified time  copyir.com CLUD1 sensor trouble Paper feed tray 1 lift unit trouble  copyir.com PCU PWB trouble  copyir.com Harness and connector connection trouble  copyir.com    Check connection of the harness and the connector of LUD1  copyir.com Replace the lift-up unit  copyir.com Replace the PCU PWB  copyir.com
H2-00    Thermister open trouble (TH_UM_AD2)    Thermister trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H2-01    Thermister open trouble (TH_LM)    Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H2-02    Sub thermister open trouble (TH_US)    Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H2-03    Compensation thermister open trouble (TH_UM_AD1)    Thermister trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H2-04    Thermister open (TH_EX1)    Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H2-05    Thermister open (TH_EX2)    Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Fusing unit not installed  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
H3-00    Fusing section high temperature trouble (TH_UM)    The fusing temperature exceeds the specified level  copyir.com Thermister trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com Power unit trouble  copyir.com    Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Replace the power unit  copyir.com
H3-01    Fusing section high temperature trouble (TH_LM)    The fusing temperature exceeds the specified level  copyir.com Thermister trouble  copyir.com PCU PWB trouble  copyir.comHarness and connector connection trouble  copyir.com Power unit trouble  copyir.com    Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Replace the power unit  copyir.com
H3-02    Fusing section high temperature trouble (TH_US)    The fusing temperature exceeds the specified level  copyir.com Thermister trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com Power unit trouble  copyir.com    Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Replace the power unit  copyir.com
H3-04    Fusing section high temperature trouble (TH_EX1)    The fusing temperature exceeds the specified level  copyir.com Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Power unit trouble  copyir.com Fusing unit not installed  copyir.com    Replace the power unit  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Use SIM14 to cancel the trouble  copyir.com
H3-05    Fusing section high temperature trouble (TH_EX2)    The fusing temperature exceeds the specified level  copyir.com Thermister trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Power unit trouble  copyir.com    Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Replace the power unit  copyir.com Use SIM14 to cancel the trouble  copyir.com
H4-00    Fusing section low temperature trouble (TH_UM_AD2)    The fusing temperature does not reach the specified level within the specified time from turning ON the power relay  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble  copyir.com Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com
H4-01    Fusing section low temperature trouble (TH_LM)    The fusing temperature does not reach the specified level within the specified time from turning ON the power relay  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com
H4-02    Fusing section low temperature trouble (TH_US)    The fusing temperature does not reach the specified level within the specified time from turning ON the power relay  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com
H4-04    Fusing section low temperature trouble (TH_EX)    The specified temperature is not reached within the specified time from starring warm-up  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble  copyir.com Thermostat trouble  copyir.com Power unit trouble  copyir.com    Use SIM5-2 to check the operation of the heater lamp  copyir.com Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com Replace the heater lamp  copyir.com Replace the power unit  copyir.com Use SIM14 to cancel the trouble  copyir.com
H4-30    Thermister input circuit trouble (TH_UM)    The values of TH_UM_AD1 and TH_UM_AD2 do not exceed the specified value (50 counts in AD value) within the specified time from turning ON the HL_UM  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com Use SIM14 to cancel the trouble  copyir.com
H5-01    5 times continuous POD1 not-reach jam    A fusing jam is not canceled completely  copyir.com (A jam paper remains  copyir.com) POD1 sensor trouble  copyir.com Fusing unit installation trouble  copyir.com Connector, harness connection trouble  copyir.com PCU PWB trouble    Replace the POD1 sensor  copyir.com Check the installing position of the fusing unit  copyir.com Replace the fusing unit  copyir.com Check connection of the connector and the harness  copyir.com Replace the PCU PWB  copyir.com Use SIM14 to cancel the trouble  copyir.com
H7-10    Fusing low temperature recovery trouble (TH_UM_AD2)  copyir.com    The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com
H7-11    Fusing low temperature recovery trouble (TH_LM)    The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com
H7-12    Fusing low temperature recovery trouble (TH_US)    The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com Interlock switch trouble  copyir.com    Replace the thermister  copyir.com Replace the heater lamp  copyir.com Replace the PCU PWB  copyir.com Replace the thermostat  copyir.com Check connection of the connector and the harness  copyir.com Replace the power unit  copyir.com Replace the interlock switch  copyir.com Use SIM5-2 to check the flashing operation of the heater lamp  copyir.com
H7-14    Low temperature trouble (TH_EX) in reset operation after JOB stop due to a fall in the fusing temperature during a JOB  copyir.com    The specified temperature is not reached within the specified time in reset operation of the fusing temperature  copyir.com Thermister trouble  copyir.com Heater lamp trouble  copyir.com PCU PWB trouble  copyir.com Thermostat trouble  copyir.com Connector, harness connection trouble  copyir.com Power unit trouble  copyir.com    Use SIM5-2 to check the operation of the heater lamp  copyir.com Replace the thermister  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com Replace the heater lamp  copyir.com Replace the power unit  copyir.com Use SIM14 to cancel the trouble  copyir.com
H8-00    Fusing unit initial detection trouble    The initial detection fuse is not blown off though it is conducted for the specified time  copyir.com Fusing unit trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-51 to check the operations of the [FUCRU] fuse blowing circuit  copyir.com Use SIM30-1 to check the [FUCRU] initial detection input signal  copyir.com Replace the fusing unit  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
L1-00    Scanner feed trouble    Scanner feed is not completed within the specified time  copyir.com Scanner unit trouble  copyir.com SCU PWB trouble Scanner control PWB trouble  copyir.com Harness and connector connection trouble  copyir.com Scanner home position sensor trouble  copyir.com Scanner motor trouble  copyir.com    Use SIM1-1 to check the scan operation  copyir.com Replace the scanner unit  copyir.com Replace the SCU PWB  copyir.com Check connection of the connectors and the harness  copyir.com Replace the scanner home position sensor  copyir.com Replace the scanner motor  copyir.com
L3-00    Scanner return trouble    Scanner return is not completed within the specified time  copyir.com Scanner unit trouble  copyir.com SCU PWB trouble Scanner control PWB trouble  copyir.com Harness and connector connection trouble  copyir.com Scanner home position sensor trouble  copyir.com Scanner motor trouble  copyir.com    Use SIM1-1 to check the scan operation  copyir.com Replace the scanner unit  copyir.com Replace the SCU PWB  copyir.com Check connection of the connectors and the harness  copyir.com Replace the scanner home position sensor  copyir.com Replace the scanner motor  copyir.com
L4-03    Fusing motor lock trouble    The motor lock signal is detected during rotation of the fusing motor  copyir.com Fusing motor trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use Sim6-1 to check the operation of the fusing motor  copyir.com Replace the fusing motor  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
L4-04    Developing motor trouble (BLACK)    The motor lock signal is detected during rotation of the developing motor  copyir.com Developing motor trouble  copyir.com Harness and connector connection trouble  copyir.com PCU PWB trouble Developing unit trouble  copyir.com    Use SIM25-1 to check the operation of the developing motor  copyir.com Replace the developing motor  copyir.com Check connection of the connectors and the harness  copyir.com Replace the PCU PWB  copyir.com Replace the developing motor  copyir.com Replace the developing unit  copyir.com
L4-05    Developing motor trouble (COLOR)    The motor lock signal is detected during rotation of the developing motor  copyir.com Developing motor trouble  copyir.com Harness and connector connection trouble  copyir.com PCU PWB trouble Developing unit trouble  copyir.com    Use SIM25-1 to check the operation of the developing motor  copyir.com Replace the developing motor  copyir.com Check connection of the connectors and the harness  copyir.com Replace the PCU PWB  copyir.com Replace the developing motor  copyir.com Replace the developing unit  copyir.com
L4-06    Transfer unit lift trouble    Transfer unit position sensor trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Transfer unit separation clutch operation trouble  copyir.com Primary transfer belt unit is not installed  copyir.com    Use SIM6-3 to check the separating operation of the transfer unit  copyir.com Install the primary transfer belt unit  copyir.com Replace the transfer unit position sensor  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com Replace the transfer unit separation clutch  copyir.com
L4-12    Secondary transfer separation trouble    A change in the state of the separation sensor is not detected in the specified time during separating operation of the secondary transfer unit  copyir.com Secondary transfer unit separation mechanism trouble Secondary transfer unit separation motor trouble  copyir.com Secondary transfer unit separation sensor trouble  copyir.com Connection trouble of the connector and the harness  copyir.com PCU PWB trouble  copyir.com    Check the operation of the secondary transfer unit separation mechanism  copyir.com Replace the secondary transfer unit separation motor  copyir.com Replace the secondary transfer unit separation sensor  copyir.com Check connection of the connector and the harness  copyir.com Replace the PCU PWB  copyir.com
L4-16    Fusing pressure release trouble    No change in the fusing pressure release sensor signal is detected within the specified time after turning ON the fusing pressure release solenoid  copyir.com Fusing pressure release sensor trouble  copyir.com Fusing pressure release solenoid trouble  copyir.com Fusing pressure release level F, R trouble  copyir.com PCU PWB trouble  copyir.com Fusing motor trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Replace the fusing pressure release sensor  copyir.com Replace the fusing pressure release solenoid  copyir.com Replace the fusing pressure release lever F, R  copyir.com Replace the PCU PWB  copyir.com Fusing motor trouble  copyir.com Harness and connector connection trouble  copyir.com
L4-29    HDD fan trouble    The fan lock signal is detected during rotation of the HDD fan  copyir.com HDD fan trouble  copyir.com MFP PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-2 to check the operation of the fan motor  copyir.com Replace the HDD fan  copyir.com Replace the MFP PWB  copyir.com Replace the connector or the harness  copyir.com
L4-31    Paper exit cooling fan trouble    The fan operation signal is not detected within the specified time in the paper exit cooling fan operation  copyir.com Paper exit cooling fan trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com    Check connection of the connectors and the harness  copyir.com Use SIM6-2 to check the rotating operation of the fan  copyir.com Replace the paper exit cooling fan  copyir.com Replace the PCU PWB  copyir.com
L4-32    Power source cooling fan trouble    The fan operation signal is not detected within the specified time in the power cooling fan operation  copyir.com Power cooling fan trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM6-2 to check the rotating operation of the fan  copyir.com Replace the power cooling fan  copyir.com Replace the PCU PWB  copyir.com Check/replace the connector or the harness  copyir.com
L4-34    LSU fan trouble    The fan rotation signal is not detected in the specified time during operation of the LSU fan  copyir.com Connection trouble of the connector and the harness  copyir.com LSU fan trouble  copyir.com LSU control PWB trouble  copyir.com    Use Sim6-2 to check the operation of the fan  copyir.com Check connection of the connector and the harness  copyir.com Replace the LSU fan  copyir.com Replace the LSU control PWB  copyir.com
L4-35    Fusing cooling fan trouble    The fan operation signal is not detected within the specified time in the fusing cooling fan operation  copyir.com Fusing cooling fan trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com    Use SIM6-2 to check the rotating operation of the fan  copyir.com Replace the fusing cooling fan  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
L4-50    Process fan trouble    The fan operation signal is not detected within the specified time in the process fan operation  copyir.com Process fan trouble  copyir.com PCU PWB trouble Connection trouble of the connector and the harness  copyir.com    Check that the fan is rotating after turning ON the power  copyir.com Replace the process fan  copyir.com Replace the PCU PWB  copyir.com Harness and connector connection trouble  copyir.com
L4-51    Process fan 2 trouble    The fan operation signal is not detected within the specified time in the process fan 2 operation  copyir.com Process fan trouble  copyir.com PCU PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Check that the fan is rotating after turning ON the power  copyir.com Replace the process fan 2  copyir.com Replace the PCU PWB  copyir.com Check connection of the connector and the harness  copyir.com
L6-10    Polygon motor trouble    The motor does not reach the specified rpm in 7 sec after starting rotation of the polygon motor  copyir.com Polygon motor trouble  copyir.com LSU control PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM61-1 to check the operation of the polygon motor  copyir.com Check connection of the connectors and the harness  copyir.com Replace the polygon motor  copyir.com Replace the LSU  copyir.com Replace the LSU control PWB  copyir.com
L8-01    Full wave signal detection error    No full wave signal is detected  copyir.com PCU PWB trouble Power unit trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Replace the PCU PWB  copyir.com Replace the power unit  copyir.com Check connection of the connectors and the harness  copyir.com
L8-02    Full wave signal error    An abnormality in the full wave signal frequency is detected  copyir.com (The frequency is detected as 65Hz or above, or 45Hz or less  copyir.com)PCU PWB trouble  copyir.com Power unit trouble  copyir.com Connection trouble of the connector and the harness  copyir.com Power frequency, waveform abnormality  copyir.com    Replace the PCU PWB  copyir.com Replace the power unit  copyir.com Check connection of the connectors and the harness  copyir.com Check the power waveform  copyir.com
L8-20    MFP PWB – Mother board communication error    Mother board PWB – MFPC PWB connection trouble  copyir.com MFP PWB trouble  copyir.com Replace the mother board  copyir.com    Check connection between the mother board and the MFPC PWB  copyir.com Check the earth line of the main unit  copyir.com Replace the MFPC PWB  copyir.com Replace the mother board  copyir.com
PC–    Personal counter not detected    The personal counter is not installed  copyir.com The personal counter is not detected  copyir.com    Check connection of the connectors and the harness  copyir.com Replace the SCU PWB  copyir.com
U1-01    Battery trouble    1) Battery life 2) Battery circuit abnormality    Check to confirm that the battery voltage is about 2  copyir.com0V or above  copyir.com Use SIM13 to cancel the trouble  copyir.com
U2-00    MFP EEPROM read/write error    MFP PWB EEPROM trouble  copyir.com EEPROM socket contact trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Use SIM16 to cancel the error  copyir.com Replace the MFP PWB EEPROM  copyir.com Replace the MFP PWB  copyir.com Check the power environment  copyir.com
U2-05    HDD/MFP PWB SRAM contents inconsistency    The HDD or the MFP PWB which differs from that before turning OFF the power is installed  copyir.com HDD trouble  copyir.com MFP PWB trouble  copyir.com    Use SIM16 to cancel the error  copyir.com If there is backup data (export data by device cloning), import it  copyir.com
U2-10    MFP PWB SRAM user authentication index check sum error    SRAM user index information (user authentication basic data) check sum error  copyir.com MFP PWB SRAM trouble  copyir.com Strong external noises  copyir.com    Use SIM16 to cancel the error  copyir.com Transfer the user index information data in the HDD to the SRAM  copyir.com Replace the MFP PWB  copyir.com
U2-11    MFP PWB EEPROM counter check sum error    MFP PWB EEPROM trouble  copyir.com EEPROM socket contact trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Use SIM16 to cancel the error  copyir.com Replace the MFP PWB  copyir.com
U2-22    MFP PWB SRAM memory check sum error    The identifier which controls the communication management table stored in the SRAM and the FAX soft switch is not detected correctly  copyir.com MFP PWB SRAM trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Since the data of the communication management table and the FAX soft switch stored in the SRAM are initialized when an error occurs, register the deleted data again individually  copyir.com Use SIM16 to cancel the error  copyir.com Replace the MFP PWB  copyir.com
U2-23    MFP PWB SRAM memory individual data check sum error    The check sum value for individual data of the communication table and the sender registration does not match  copyir.com MFP PWB SRAM trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Turn OFF/ON the power to initialize the data related to the content of check sum error  copyir.com Since the registered contents are deleted, register the deleted contents again  copyir.com Use SIM16 to cancel the error  copyir.com Replace the MFP PWB  copyir.com
U2-24    MFP PWB SRAM memory user authentication counter check sum error    MFP PWB SRAM trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Use SIM16 to cancel the error  copyir.com
U2-30    MFP PWB and PCU PWB manufacturing No  copyir.com data inconsistency    Inconsistency between the manufacturing No  copyir.com saved in the PCU PWB and that in the MFP PWB  copyir.com When replacing the PCU PWB or the MFP PWB, the EEPROM which was mounted on the PWB before replacement is not mounted on the new PWB  copyir.com MFP PWB trouble  copyir.com PCU PWB trouble    Check that the EEPROM is properly set  copyir.com Check to confirm that the EEPROM which was mounted on the PWB before replacement is mounted on the new PWB  copyir.com Use SIM16 to cancel the error  copyir.com Replace the MFP PWB  copyir.com Replace the PCU PWB  copyir.com
U2-50    HDD user authentication data check sum error    HDD trouble  copyir.com MFP PWB trouble  copyir.com Strong external noises  copyir.com    Initialize the data (one-touch, group, program, etc  copyir.com) related to the check sum error by turning OFF/ON the power  copyir.com Since the registered contents are deleted, register the deleted contents again  copyir.com Use SIM16 to cancel the error  copyir.com Replace the HDD  copyir.com Replace the MFP PWB  copyir.com
U2-80    SCU PWB EEPROM read/write error    SCU PWB EEPROM trouble  copyir.com SCU PWB trouble  copyir.com EEPROM socket contact trouble  copyir.com    Replace the SCU PWB EEPROM  copyir.com Replace the SCU PWB  copyir.com Check contact of the EEPROM socket  copyir.com Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values  copyir.com Use SIM16 to cancel the trouble  copyir.com
U2-81    SCU PWB EEPROM check sum error    SCU PWB EEPROM trouble  copyir.com Installation of non-initialized EEPROM  copyir.com SCU PWB trouble  copyir.com EEPROM socket contact trouble  copyir.com    Replace the SCU PWB EEPROM  copyir.com Replace the SCU PWB  copyir.com Check contact of the EEPROM socket  copyir.com Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values  copyir.com Use SIM16 to cancel the trouble  copyir.com
U2-90    PCU PWB EEPROM read/write error    PCU PWB EEPROM trouble  copyir.com Installation of non-initialized EEPROM  copyir.com PCU PWB trouble EEPROM socket contact trouble  copyir.com    Replace the PCU PWB EEPROM  copyir.com Replace the PCU PWB  copyir.com Check contact of the EEPROM socket  copyir.com Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values  copyir.com Use SIM16 to cancel the trouble  copyir.com
U2-91    PCU PWB EEPROM check sum error    PCU PWB EEPROM trouble  copyir.com Installation of non-initialized EEPROM  copyir.com PCU PWB trouble EEPROM socket contact trouble  copyir.com    Replace the PCU PWB EEPROM  copyir.com Replace the PCU PWB  copyir.com Check contact of the EEPROM socket  copyir.com Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values  copyir.com Use SIM16 to cancel the trouble  copyir.com
U6-00    PCU PWB – Desk paper feed unit communication error    Error when testing the communication line after turning ON the power or canceling the simulation  copyir.com Connector, harness connection trouble  copyir.com Desk control PWB trouble  copyir.com PCU PWB trouble Strong external noises  copyir.com    Turn OFF/ON the power to cancel  copyir.com Check the connector and the harness in the communication line  copyir.com Replace the desk control PWB  copyir.com Replace the PCU PWB  copyir.com
U6-01    Desk paper feed tray 1 lift trouble    D1ULD does not turn ON within the specified time when lift-up operation  copyir.com D1ULD sensor trouble  copyir.com Desk control PWB trouble  copyir.com Lift unit trouble  copyir.com Connection trouble of the connector and the harness  copyir.com PCU PWB trouble    Replace the D1ULD sensor  copyir.com Replace the desk control PWB  copyir.com Replace the lift unit  copyir.com Harness and connector connection trouble  copyir.com Replace the PCU PWB  copyir.com
U6-02    Desk paper feed tray 2 lift trouble    D2ULD does not turn ON within the specified time when lift-up operation  copyir.com D2ULD sensor trouble  copyir.com Desk control PWB trouble  copyir.com Lift unit trouble  copyir.com Connection trouble of the connector and the harness  copyir.com PCU PWB trouble    Replace the D2ULD sensor  copyir.com Replace the desk control PWB  copyir.com Replace the lift unit  copyir.com Harness and connector connection trouble  copyir.com Replace the PCU PWB  copyir.com
U6-03    Desk paper feed tray 3 lift trouble    The D3ULD sensor is not turned ON within the specified time during lift-up operation  copyir.com D3ULD sensor trouble  copyir.com Desk control PWB trouble  copyir.com Lift unit trouble  copyir.com Connection trouble of the connector and the harness  copyir.com PCU PWB trouble  copyir.com    Replace the D3ULD sensor  copyir.com Replace the desk control PWB  copyir.com Replace the lift unit  copyir.com Check connection of the connector and the harness  copyir.com Replace the PCU PWB  copyir.com
U6-10    Desk paper feed unit paper transport motor trouble    Desk paper feed motor trouble (motor lock, motor rpm abnormality, overcurrent to the motor)  copyir.com Desk control PWB trouble  copyir.com Connection trouble of the connector and the harness  copyir.com    Use SIM4-3 to check the operation of the desk transport motor  copyir.com Replace the desk control PWB  copyir.com Replace the desk paper feed motor  copyir.com Harness and connector connection trouble  copyir.com
U6-50    Desk – Main unit combination trouble    Improper combination between the main unit and the desk  copyir.com Desk control PWB trouble  copyir.com    Install a desk which is proper for the main unit mode  copyir.com Replace the desk control PWB  copyir.com
U7-50    MFP PWB – Vendor machine communication error    Improper setting of the vendor machine specifications (SIMI26-3)  copyir.com Vendor machine trouble  copyir.com MFP PWB trouble  copyir.com Connector, harness connection trouble  copyir.com Strong external noises  copyir.com    Cancel the error by turning OFF/ON the power  copyir.com Check the connector and the harness in the communication line  copyir.com Change the specifications of the vendor machine (SIM26-3)  copyir.com Replace the LCC control PWB  copyir.com Replace the MFP PWB  copyir.com
U7-51    Vendor machine error
MFP (Notification of a trouble from the serial vendor)    Serial vendor machine trouble  copyir.com Connector, harness connection trouble  copyir.com    Err  copyir.comXX” is displayed on the operation panel of the vendor  copyir.com (XX is the detail code  copyir.com) Repair the vendor machine referring to the detail code  copyir.com Check the connector and the harness in the communication line  copyir.comK
UC-02    IPD ASIC (CPT) error    IPD ASIC (CPT) operation error SCN PWB trouble  copyir.com    Replace the SCN PWB  copyir.com
UC-20    IPD ASIC (DOCC) error    IPD ASIC (DOCC) operation error SCN PWB trouble  copyir.com    Replace the SCN PWB  copyir.com