شارپ Sharp MXM264U
A0-01 PCU PWB ROM error The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc copyir.com PCU PWB trouble copyir.com
A0-02 SCU PWB ROM error The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc copyir.com SCU PWB trouble copyir.com
A0-04 Scanner expansion PWB (ACU) (ACRE) ROM error Scanner expansion PWB (ACU) (ACRE) ROM data error copyir.com An error occurs during firmware upgrading for some reasons copyir.com
A0-10 Color profile error The content of the color profile is abnormal copyir.com Combination error between the MFPC PWB firmware and the color profile
A0-11 Firmware version inconsistency (MFP – PCU) Firmware combination error between the MFP and the PCU copyir.com
A0-15 Incompatible DSK BOOT and program firmware Installation of the normal firmware was performed with a security kit enable copyir.com
A0-20 Conflict firmware and EEPROM data version (MFP) Inconsistency between the MFP firmware version and the EEPROM data version copyir.com
A0-21 Conflict firmware and EEPROM data version (PCU) Inconsistency between the PCU firmware version and the EEPROM data version copyir.com
A0-22 Conflict firmware and EEPROM data version (SCU) Inconsistency between the SCU firmware version and the EEPROM data version copyir.com
E7-01 MFP image data error Image data transfer error in the MFPC PWB copyir.com MFPC PWB trouble copyir.com
E7-03 HDD trouble Connector, harness connection trouble in the MFPC PWB and HDD copyir.com HDD (error file management area) data abnormality (FAT breakage) copyir.com MFPC PWB trouble copyir.com
E7-04 HDD-ASIC error HDD-ASIC trouble copyir.com (MFPC PWB trouble copyir.com) An error occurs in the HDD-ASIC self test when booting copyir.com
E7-07 SD card error SD card trouble or contact error MFPC PWB trouble copyir.com
E7-10 Shading error (Black correction) Abnormality in the CCD black scan level when the scanner lamp is turned OFF copyir.com Improper installation of the harness to the CCD unit copyir.com CCD unit abnormality copyir.com SCU PWB abnormality copyir.com
E7-11 Shading error (White correction) Abnormality in the CCD white reference plate scan level when the scanner lamp is turned ON copyir.com Improper installation of the harness to the CCD unit copyir.com Dirt on the mirror, lens, and the reference white plate copyir.com Scanner lamp lighting trouble copyir.com Scanner lamp drive PWB trouble CCD unit abnormality copyir.com SCU PWB abnormality copyir.com
E7-14 CCD-ASIC error SCU PWB trouble copyir.com
E7-20 LSU laser detection error Laser optical axis misalignment Reduced laser power, lighting error, laser diode trouble copyir.com LSU harness, connector trouble LSU trouble
E7-21 LSU LD deterioration trouble
Laser trouble Laser deterioration, power reduction Disconnection or improper connection of harness and connector between LD PWB and MFPC PWB copyir.com
E7-28 LSU control Asic connection error
Access error between the CPU in the PCU PWB and the LSU control ASIC copyir.com Improper connection of the communication connector between the PCU PWB and the MFPC PWB (interface PWB) copyir.com Harness trouble between the PCU PWB and the MFPC PWB (interface PWB) PCU PWB or MFPC PWB (interface PWB) trouble copyir.com
E7-49 Water Mark data error Watermark data trouble copyir.com
HDD trouble copyir.com
* When the wartermark data is not installed, U2-60 error occurs in booting copyir.com
E7-50 PCU connection trouble
Unknown PWB identification information is detected in the PCU PWB copyir.com A PWB/firmware which does not comply with the machine specifications is connected copyir.com
E7-55 PCU PWB information sum error
PCU EEPROM PWB information sum error PCU EEPROM sum check error copyir.com PCU EEPROM trouble copyir.com PCU EEPROM contact trouble copyir.com
E7-60 MFP connection trouble
Unknown PWB identification information is detected in the MFPC PWB copyir.com A PWB/firmware which does not comply with the machine specifications is connected copyir.com
E7-61 MFP connection trouble (PCU)
MFP connection trouble
Compatibility trouble between MFP – PCU Combination error between the MFPC PWB and the PCU copyir.com
E7-65 MFP EEPROM check sum error
EEPROM PWB information check sum error EEPROM device trouble copyir.com EEPROM device contact trouble copyir.com Device access error due to noises copyir.com
E7-80 MFP – SCU PWB communication error SCU PWB – MFPC PWB connection trouble copyir.com SCU PWB trouble copyir.com MFPC PWB trouble copyir.com
E7-90 MFP – PCU PWB communication error PCU PWB – MFPC PWB connection trouble copyir.com PCU PWB trouble copyir.com MFPC PWB trouble copyir.com
E7-91 FAX reception image data error
An error of FAX reception image data process occurs copyir.com Image data process abnormality HDD trouble SD card trouble or contact error Image compression data corruption MFPC PWB trouble DIMM memory trouble or contact error FAX control PWB trouble
E7-92 Copy image data error
An error of copy image data process occurs copyir.com (In Non ERDH) Image data process abnormality HDD trouble Image compression data corruption MFPC PWB trouble DIMM memory trouble or contact error
E7-93 Copy, image send, FAX, filing, print image data process error
An image data process error occurs in the following operation mode: • Copy (in ERDH) • Copy composing system function (Water mark) • When in image send • When filing documents • When displaying the preview • When printing with the GDI/PCL printer • Copy composing system function (Water mark) • When printing FAX send result table Image data process abnormality HDD trouble Image compression data corruption MFPC PWB trouble DIMM memory trouble or contact error
E7-94 Image file data process error (when importing file data)
File image process error (backup restore error) when importing filing data Image data process abnormality HDD trouble Image compression data corruption MFPC PWB trouble DIMM memory trouble or contact error
E7-96 MFPC PWB DIMM memory check error
MFPC PWB DIMM memory access trouble Memory data corruption occurs MFPC PWB trouble DIMM memory trouble or contact error
EE-EL Auto developer adjustment trouble (Over-toner abnormality)
An abnormality occurred in execution of automatic developer adjustment copyir.com Toner density sensor trouble, charging voltage/ developing voltage error, toner concentration trouble, developing unit trouble, PCU PWB trouble copyir.com
EE-EU Auto developer adjustment trouble (Under-toner abnormality)
An abnormality occurred in execution of automatic developer adjustment copyir.com Toner density sensor trouble, charging voltage/ developing voltage error, toner concentration trouble, developing unit trouble, PCU PWB trouble copyir.com
F1-00 Finisher – PCU PWB communication error Connection trouble of the connector and the harness between the finisher and the PCU PWB copyir.com Finisher control PWB trouble copyir.com PCU PWB trouble copyir.com
F1-03 Finisher paper exit roller lifting operation trouble Finisher paper exit roller lift motor trouble Harness and connector connection trouble Home position sensor trouble Finisher control PWB trouble
F1-10 Staple operation trouble Staple motor trouble copyir.com Finisher control PWB trouble copyir.com Home position sensor trouble copyir.com
F1-15 Finisher paper exit tray lift operation trouble Paper exit tray lift motor trouble copyir.com Finisher control PWB trouble copyir.com Home position sensor trouble copyir.com
F1-19 Finisher alignment operation trouble F Finisher paper alignment motor lock copyir.com Motor speed abnormality copyir.com Over-current to the motor copyir.com Finisher control PWB trouble copyir.com Home position sensor trouble copyir.com
F1-20 Finisher alignment operation trouble R Finisher paper alignment motor lock copyir.com Motor speed abnormality copyir.com Over-current to the motor copyir.com Finisher control PWB trouble copyir.com Home position sensor trouble copyir.com
F1-29 Finisher cooling fan motor abnormality
Finisher cooling fan motor abnormality Motor lock Motor harness short/open copyir.com Finisher control PWB trouble copyir.com Harness/connector connection trouble copyir.com
F1-37 Finisher data backup RAM error Finisher control PWB trouble copyir.com Malfunction due to noises
F1-50 Main unit – Finisher combination error The finisher which is not supported by the main unit model is installed copyir.com Finisher control PWB trouble copyir.com
F1-95 Paper exit option configuration error The paper exit option configuration is improper copyir.com
F2-39 Process thermistor trouble Process thermistor trouble copyir.com Process thermistor harness connection trouble copyir.com PCU PWB trouble copyir.com
F2-40 Toner density sensor trouble Toner density sensor output abnormality copyir.com Sensor connector and harness connection trouble copyir.com Developing unit trouble copyir.com PCU PWB trouble copyir.com
F2-58 Temperature/humidity sensor trouble (HUD_M/TH_M) Temperature/humidity sensor trouble copyir.com Process humidity sensor harness and connector connection trouble PCU PWB trouble copyir.com
F2-64 Toner supply operation trouble Toner motor trouble copyir.com Toner density sensor trouble copyir.com Connector/harness trouble copyir.com PCU PWB trouble copyir.com Toner cartridge trouble copyir.com Developing unit trouble copyir.com Toner transport pipe section trouble
F2-70 Improper toner cartridge detection An improper toner cartridge is inserted copyir.com (The main unit detects a toner cartridge of a different specification copyir.com) Toner cartridge trouble copyir.com PCU PWB trouble copyir.com
F2-74 Toner cartridge CRUM error Toner cartridge (CRUM) trouble copyir.com PCU PWB trouble copyir.com Connector and harness trouble between PCU PWB and toner cartridge
F3-12 Paper feed tray 1 lift operation trouble
C1LUD is not turned ON within the specified time C1LUD is not turned ON within the specified time copyir.com C1LUD sensor trouble copyir.com Paper feed tray 1 lift unit trouble copyir.com PCU PWB trouble copyir.com Sensor harness and connector connection trouble
F3-22 Paper feed tray 2 lift operation trouble
C2LUD does not turn ON within the specified time copyir.com C2LUD does not turn ON within the specified time copyir.com C2LUD sensor trouble copyir.com Paper feed tray 2 lift unit trouble copyir.com PCU PWB trouble copyir.com Sensor harness and connector connection trouble
F3-32 Paper feed tray 3 lift operation trouble
C3LUD does not turn ON within the specified time copyir.com C3LUD does not turn ON within the specified time copyir.com C3LUD sensor trouble copyir.com Paper feed tray 3 lift unit trouble copyir.com PCU PWB trouble copyir.com Sensor harness and connector connection trouble
F3-42 Paper feed tray 4 lift operation trouble
C4LUD does not turn ON within the specified time copyir.com C4LUD does not turn ON within the specified time copyir.com C4LUD sensor trouble copyir.com Paper feed tray 4 lift unit trouble copyir.com PCU PWB trouble copyir.com Sensor harness and connector connection trouble
F6-00 MFPC PWB – FAX communication trouble FAX control PWB trouble copyir.com FAX control PWB – MFPC PWB connector and harness trouble
F6-01 FAX control PWB EEPROM read/write error
FAX control PWB EEPROM access error (Read and write) FAX control PWB EEPROM trouble FAX control PWB EEPROM access circuit trouble
F6-04 FAX MODEM operation trouble
FAX control PWB MODEM chip operation trouble FAX MODEM chip operation trouble copyir.com The FAX MODEM chip cannot be accessed copyir.com
F6-21 Improper combination of TEL/LIU PWB and FAX soft switch
Incompatibility between the TEL/LIU PWB and the FAX control PWB information (soft switch) The destination of the TEL/LIU PWB installed is improper copyir.com TEL/LIU PWB trouble copyir.com
F6-30 FAX 1-chip microprocessor access error (FAX detection)
FAX 1-chip microprocessor access error (Read and write) Program writing trouble to the 1-chip microprocessor, or no program data written copyir.com FAX 1-chip microprocessor circuit trouble copyir.com
F6-97 Incompatibility between FAX control PWB and the main machine
Incompatibility between FAX control PWB and the main machine The FAX control PWB installed is improper copyir.com FAX control PWB trouble copyir.com
F6-98 Incompatibility between the FAX control PWB destination and the main machine destination Incompatibility between the FAX control PWB destination and the main machine destination Incompatibility between the destination information written into the FAX control PWB EEPROM and that in the main machine (set with SIM26-6)
H2-00 Thermistor open trouble (TH_UM)
Main thermistor open hardware detection trouble Main thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Fusing section connector connection trouble Fusing unit not installed
H2-01 Thermistor open trouble (TH_US)
Sub thermistor open hardware detection trouble Sub thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Fusing section connector connection trouble Fusing unit not installed
H3-00 Fusing section high temperature trouble (TH_UM)
Main heater lamp abnormally high temperature software detection trouble The fusing temperature exceeds the specified level copyir.com Main thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Power unit trouble copyir.com
H3-01 Fusing section high temperature trouble (TH_US)
Sub heater lamp abnormally high temperature software detection trouble The fusing temperature exceeds the specified level copyir.com Sub thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Power unit trouble copyir.com
H4-00 Fusing section low temperature trouble (TH_UM)
The fusing temperature does not reach the specified level within the specified time from turning ON the power relay copyir.com Main thermistor trouble copyir.com Main heater lamp trouble copyir.com PCU PWB trouble copyir.com Thermostat trouble copyir.com Connector, harness connection trouble copyir.com HL control PWB trouble copyir.com Power unit trouble copyir.com
H4-01 Fusing section low temperature trouble (TH_US)
The fusing temperature does not reach the specified level within the specified time from turning ON the power relay copyir.com Sub thermistor trouble copyir.com Sub heater lamp trouble copyir.com PCU PWB trouble copyir.com Thermostat trouble copyir.com Connector, harness connection trouble copyir.com HL control PWB trouble copyir.com Power unit trouble copyir.com
H5-01 5-time continuous jams of POD1, POD2, or PPD2 A fusing jam is not canceled completely copyir.com (A jam paper remains copyir.com) POD1/POD2/PPD2 sensor trouble Fusing unit installation trouble POD1/POD2/PPD2 sensor connector and harness connection trouble PCU PWB trouble Fusing unit, drive section trouble
L1-00 Scanner feed trouble
Scanner feed is not completed within the specified time copyir.com Scanner unit trouble copyir.com SCU PWB trouble copyir.com Scanner control PWB trouble copyir.com Harness and connector connection trouble copyir.com Scanner home position sensor trouble copyir.com Scanner motor trouble copyir.com
L3-00 Scanner return trouble
Scanner return is not completed within the specified time copyir.com Scanner unit trouble SCU PWB trouble Scanner control PWB trouble Harness and connector connection trouble Scanner home position sensor trouble Scanner motor trouble
L4-01 Main motor lock trouble
The motor lock signal is detected during rotation of the main motor copyir.com Main motor lock trouble Harness and connector connection trouble PCU PWB trouble
L4-11 Shift motor trouble
No change in the shifter home position sensor signal is detected in the operation of the shifter initializing copyir.com Shift motor trouble copyir.com PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Shifter home position sensor trouble copyir.com
L4-30 MFP fan motor trouble
The motor lock signal is detected during rotation of the MFP fan motor copyir.com Fan motor trouble copyir.com Harness connection trouble between the MFPC PWB and the fan motor copyir.com MFP circuit trouble copyir.com
L4-31 Paper exit cooling fan trouble
The fan operation signal is not detected copyir.com Paper exit cooling fan trouble copyir.com PCU PWB trouble Connection trouble of the connector and the harness copyir.com
L4-32 Power source cooling fan trouble
The fan operation signal is not detected copyir.com Power cooling fan trouble copyir.com PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L4-35 Fusing cooling fan trouble
The fan operation signal is not detected copyir.com Fusing cooling fan trouble copyir.com PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L4-43 Paper exit cooling fan 2 trouble
The fan operation signal is not detected copyir.com Paper exit cooling fan trouble copyir.com PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L4-44 Power cooling fan 2 trouble
The lock signal is detected while the power cooling fan is operating copyir.com Power cooling fan trouble copyir.com PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L4-56 Fusing cooling fan 2 trouble
The fan operation signal is not detected copyir.com Fusing cooling fan 2 trouble PCU PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L6-10 Polygon motor trouble
The polygon motor does not reach the specified RPM within the specified time after starting rotation of the polygon motor copyir.com Polygon motor trouble copyir.com LSU mother PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com
L8-01 Full wave signal detection error
The full wave signal is not detected copyir.com PCU PWB trouble copyir.com Power unit trouble copyir.com Connection trouble of the connector and the harness copyir.com
L8-02 Full wave signal width abnormality
The full wave signal frequency is judged as abnormal copyir.com (The detected freauency is over 65Hz or below 45Hz copyir.com) PCU PWB trouble copyir.com Power unit trouble copyir.com Harness trouble copyir.com
L8-20 Power controller communication trouble
Communication establishment error / Framing / Parity / Protocol error PCU PWB – MFPC PWB connector connection trouble copyir.com Broken connector pin of the PCU PWB of the MFPC PWB copyir.com
P1-00 PCI communication error Communication error between the MFPC PWB and the PCI copyir.com Connection failure of connectors and harness between the MFPC PWB and the PCI copyir.com MFPC PWB trouble copyir.com PCI control PWB trouble copyir.com
P1-01 PCI fan error The PCI fan operation signal is not detected copyir.com PCI fan trouble copyir.com PCI control PWB trouble copyir.com
P1-02 Plasma generating device error Connection failure of connectors and harness between the plasma generating device and the PCI control PWB copyir.com Plasma generating device trouble copyir.com PCI control PWB trouble copyir.com
PC– Personal counter not detected The personal counter is not installed copyir.com The personal counter is not detected copyir.com SCU PWB trouble copyir.com
U1-01 Battery trouble
RTC backup battery voltage fall 1) Battery life
2) Battery circuit abnormality
U2-00 MFP EEPROM read/write error MFPC PWB EEPROM trouble EEPROM socket contact trouble MFPC PWB trouble Strong external noises copyir.com
U2-05 SD/MFPC PWB SRAM contents inconsistency
The SD card or the MFPC PWB installed is improper copyir.com (Erroneous detection of account management data) The SD card was replaced copyir.com The MFPC PWB was replaced copyir.com SD card trouble MFPC PWB trouble
U2-10 MFPC PWB SRAM user authentication index check sum error SRAM user index information (user authentication basic data) check sum error copyir.com MFPC PWB SRAM trouble copyir.com MFPC PWB trouble copyir.com Strong external noises copyir.com
U2-11 MFPC PWB EEPROM counter check sum error MFPC PWB EEPROM trouble EEPROM socket contact trouble MFPC PWB trouble Strong external noises copyir.com
U2-24 MFPC PWB SRAM memory user authentication counter check sum error MFPC PWB SRAM trouble MFPC PWB trouble Strong external noises copyir.com
U2-30 MFPC PWB and PCU PWB manufacturing No copyir.com data inconsistency
Inconsistency between the manufacturing No copyir.com saved
in the PCU PWB and that in the MFPC PWB copyir.com When replacing the PCU PWB or the MFPC PWB, the EEPROM which was mounted on the PWB before replacement is not mounted on the new PWB copyir.com MFPC PWB trouble PCU PWB trouble
U2-40 SD card system storage data area error A file error occurs in the SD card system storage data partition copyir.com SD card trouble MFPC PWB trouble
U2-41 HDD system storage data area error A file error occurs in the HDD system saved data area, disabling backup of the saved file of the machine adjustment values in the SD card copyir.com HDD trouble MFPC PWB trouble
U2-42 Machine adjustment data (system storage data area) error The saved file of the machine adjustment values in the SD card and the HDD cannot be found or is broken copyir.com Both of the SD card set data and the HDD system saved data area are broken copyir.com HDD trouble MFPC PWB trouble SD card trouble
U2-50 HDD user authentication data check sum error (SD card when no HDD is installed) HDD trouble MFPC PWB trouble Strong external noises copyir.com
U2-60 Watermark check error Watermark data trouble HDD trouble MFPC PWB trouble
U2-80 SCU PWB EEPROM read/write error SCU PWB EEPROM trouble SCU PWB trouble SCU PWB EEPROM socket connection trouble
U2-81 SCU PWB EEPROM check sum error SCU PWB EEPROM trouble copyir.com Installation of non-initialized EEPROM copyir.com SCU PWB trouble copyir.com EEPROM socket contact trouble copyir.com
U2-90 PCU PWB EEPROM read/write error PCU PWB EEPROM trouble PCU PWB trouble EEPROM socket contact trouble
U2-91 PCU PWB EEPROM check sum error PCU PWB EEPROM trouble PCU PWB trouble EEPROM socket contact trouble
U7-50 MFPC PWB – Vendor machine communication error Improper setting of the vendor machine specifications (SIM26-3) copyir.com Vendor machine trouble copyir.com MFPC PWB trouble copyir.com Connector, harness connection trouble copyir.com Strong external noises
U7-51 Vendor machine error
MFP (Notification of a trouble from the serial vendor) Serial vendor machine trouble copyir.com Connector, harness connection trouble copyir.com
UC-02 CPT – ASIC error
Access error to the CPT-ASIC (The ASIC does not operate normally copyir.com) BtoB connector connection trouble copyir.com SCU PWB trouble copyir.com CPT-ASIC trouble copyir.com
UC-20 DOCC ASIC error
Access error to the DOCC-ASIC (The ASIC does not
operate normally copyir.com) BtoB connector connection trouble copyir.com SCU PWB trouble copyir.com DOCC-ASIC trouble copyir.com