001    Timing Sensor did not turn ON within a certain period of time        copyir.com    1        copyir.com Recording paper jammed when feeding from the 1st cassette        copyir.com 2        copyir.com The 1st cassette is not installed        copyir.com 3        copyir.com The 1st cassette has run out of paper        copyir.com 4        copyir.com Recording paper is not loaded in the 1st cassette        copyir.com 5        copyir.com Drive Clutch defective        copyir.com 6        copyir.com Timing Sensor defective        copyir.com
007    Recording paper did not completely exit from machine        copyir.com    1        copyir.com Recording Paper Jam        copyir.com 2        copyir.com Paper Exit Sensor defective        copyir.com
012    The received data overflows from the maximum paper size of the paper feeding direction        copyir.com    Transmitter Document Jam        copyir.com
021    The fixing temperature does not rise up even if the heating circuit is “ON”        copyir.com The temperature of fuser exceeds upper limit of controllable temperature        copyir.com The cooling fun in the unit does not rotate        copyir.com    1        copyir.com Fuser Lamp connector is disconnected        copyir.com 2        copyir.com Fuser Unit defective        copyir.com 3        copyir.com Thermistor defective (Fuser Unit)        copyir.com 4        copyir.com The cooling fun is defective        copyir.com
030    Document is misfeeding        copyir.com    1        copyir.com Document is not set properly        copyir.com 2        copyir.com Defective Read Point Sensor        copyir.com
031    Document paper is too long or jammed        copyir.com Document length exceeds 2 metres        copyir.com    1        copyir.com The document may jam        copyir.com 2        copyir.com Defective Read Point Sensor        copyir.com
041    Out of toner        copyir.com    1        copyir.com No toner        copyir.com 2        copyir.com Defective Toner Sensor        copyir.com
043    Toner is getting low        copyir.com    1        copyir.com Toner is getting low        copyir.com 2        copyir.com Defective Toner Sensor        copyir.com
045    Drum Cartridge is not installed        copyir.com    1        copyir.com Toner Cartridge has not been installed        copyir.com 2        copyir.com Defective Cartridge Sensor        copyir.com
051    There is something wrong with DC motor        copyir.com    1        copyir.com DC motor connector is disconnected        copyir.com 2        copyir.com DC motor is defective        copyir.com
054    The polygon motor does not become stable within the specified time when the polygon motor is “ON”        copyir.com The behaviour of polygon motor rotation become unturned on the way        copyir.com    1        copyir.com Polygon motor connector is disconnected        copyir.com 2        copyir.com The polygon motor defective        copyir.com 3        copyir.com LSU defective        copyir.com
060    Printer Cover is open        copyir.com    1        copyir.com Cover is not firmly closed        copyir.com 2        copyir.com Connectors are not firmly connected        copyir.com
068    Rear Cover is open        copyir.com    1        copyir.com Cover is not firmly closed        copyir.com 2        copyir.com Connectors are not firmly connected        copyir.com
090    Malfunction of high voltage unit        copyir.com    1        copyir.com HVPS is defective        copyir.com 2        copyir.com Drum cartridge defective        copyir.com
091    Cooling down the fuser unit        copyir.com    The fuser unit temperature is unstable        copyir.com Wait until the “PLEASE WAIT“ is disappeared        copyir.com This is normal operation        copyir.com
092    The drum cartridge is reaching the end of its life        copyir.com    1        copyir.com The drum cartridge is reaching the end of its life        copyir.com
093    The unit is operated under the low-temperature environment which is not covered under warranty        copyir.com    1        copyir.com Thermistor defective (Operation Panel Board)        copyir.com
094    Malfunction of drum cartridge        copyir.com    1        copyir.com Mixing Paddle defective        copyir.com 2        copyir.com Defective Toner Sensor        copyir.com
400    T1 timer (35+-5 sec        copyir.com) elapsed without detecting 300 bps signal        copyir.com    Wrong number is dialled and the START button is pushed        copyir.com Telephone line is disconnected while dialling        copyir.com MAIN PCB (Modem) is defective        copyir.com Receiver is defective        copyir.com (It may only be transmitting CED)
401    DCN was returned from receiver while transmitter is waiting for CFR or FTT        copyir.com    Your machine’s ID Number is not programmed        copyir.com Possible incompatibility or incorrect Password        copyir.com
402    DCN was returned from receiver while transmitter is waiting for NSF/DIS        copyir.com    Receiver working in NON-STD mode only        copyir.com (Possible incompatibility)
403    Transmitter had no polling function        copyir.com    “POLLED=ON” (polling XMT ready) is not set at the transmitter        copyir.com Document to be transmitted is not placed at the transmitter        copyir.com
404    Transmitter sent NSS (or DCS) followed by TCF three times, but the receiver did not respond        copyir.com (CFR or FTT is usually returned)    Receiver is defective        copyir.com (Modem, MAIN PCB, etc        copyir.com) MAIN PCB is defective        copyir.com Receiver disconnects line during first NSS (or DCS) is transmitted        copyir.com
405    Transmitter received FTT after it transmitted TCF at 2400bps        copyir.com Received RTN after communicating at 2400 bps        copyir.com    Line quality is poor        copyir.com (TCF is damaged due to line noise) Receiver is defective        copyir.com (Modem, etc        copyir.com) MAIN PCB is defective        copyir.com
406    XMT-Password mismatched        copyir.com RCV-Password mismatched        copyir.com Selective RCV incomplete        copyir.com    XMT, RCV password does not match        copyir.com Last 4 digits of TSI does not match with the last 4 digits of ONE-TOUCH, ABBR telephone number        copyir.com
407    Transmitter received no response after it transmitted post message, such as EOP, MPS, EOM, etc        copyir.com        copyir.com        copyir.comor received DCN        copyir.com    Receiver is defective        copyir.com (No paper, paper jamming, etc        copyir.com) Receiver ceased receiving because of excessive error        copyir.com (Line quality is poor) MAIN PCB (Modem) is defective        copyir.com
408    Transmitter received RTN after it transmitted EOP, MPS, or EOM        copyir.com    Receiver receives data with error        copyir.com (Line quality is poor) Receiver is defective        copyir.com (Modem, etc        copyir.com) MAIN PCB is defective        copyir.com
409    Transmitter receives PIN after it transmitted a post message, such as EOP, MPS, EOM, etc        copyir.com    Receiver receives data with error due to poor line quality, and receiving operator requests voice contact        copyir.com Receiver is defective        copyir.com (Modem, etc        copyir.com) MAIN PCB is defective        copyir.com
410    Received DCN while waiting for post command        copyir.com (EOP, MPS, EOM, etc        copyir.com)    Interface or line is faulty        copyir.com Transmitter is defective        copyir.com
411    Received DCN after transmitting NSC        copyir.com    Transmitter is not ready for polling communication        copyir.com Password does not match between transmitter and receiver        copyir.com
412    No response within 12 seconds in NSS/ DCS/MPS wait state        copyir.com (After transmitting FTT)    Transmitter is defective        copyir.com MAIN PCB is defective        copyir.com
414    No response received after transmitting 3rd NSC        copyir.com    Password does not match between transmitter and receiver        copyir.com Transmitter is defective        copyir.com (No original, document jam, etc        copyir.com)
415    Remote side attempted to receive message from your machine in polling communication        copyir.com    Inform the remote side that your machine does not have the polling transmission feature        copyir.com
416    Receiver did not detect post command, such as EOP, MPS, EOM, etc        copyir.com    Transmitter is defective        copyir.com Line quality is poor        copyir.com (RTC signal is distorted due to line noise) MAIN PCB is defective        copyir.com
417    Receiver returned RTN in response to post message        copyir.com    Line quality is poor        copyir.com (There are excessive errors in received data) MAIN PCB is defective        copyir.com
420    T1 timer (35 sec        copyir.com) elapsed without detecting 300 bps signal        copyir.com    There is wrong incoming call        copyir.com (non-facsimile communication) Transmitter is defective        copyir.com MAIN PCB is defective        copyir.com
421    Busy Tone is detected after sending NSF Signal        copyir.com    Remote station disconnected the line        copyir.com Wrong number is dialled        copyir.com
422    Content of NSF (or DIS) or NSC (or DTC) was invalid        copyir.com    There is an incompatibility        copyir.com
427    DCN received to NSF/CSI/DIS transmitted        copyir.com    The interface is incompatible        copyir.com
434    CD (response from Modem) did not turn OFF within 180 sec        copyir.com after receiver detected FLAG signal        copyir.com    Remote unit is defective        copyir.com MAIN PCB is defective        copyir.com
436    DCN received after transmitting FTT        copyir.com    Transmitter is defective or incompatible        copyir.com Line quality is poor        copyir.com
456    Received relay transfer request or confidential document to distribute to an end receiving station or all confidential mailboxes are used        copyir.com    
490    Sum of error lines exceeded the limit (Function Parameter No        copyir.com 70) of 64 lines        copyir.com    Line quality is poor        copyir.com MAIN PCB is defective        copyir.com
494    Interval between two EOLs was more than 10 sec        copyir.com when receiver received message data        copyir.com    Transmitter is defective        copyir.com Line quality is poor        copyir.com (EOL is damaged due to line noise) MAIN PCB is defective        copyir.com
495    During reception, CD turned OFF or continued ON for long time        copyir.com During communication, lost loop – current        copyir.com    Line is disconnected        copyir.com Transmitter is defective        copyir.com MAIN PCB is defective        copyir.com
501    Remote unit does not have compatible Modem        copyir.com    
502    During reception, CD turned OFF or continued ON for long time        copyir.com During communication, lost loop – current        copyir.com    Line is disconnected        copyir.com Transmitter is defective        copyir.com MAIN PCB is defective        copyir.com
503    CS of modem is not able to turn ON during training        copyir.com    MAIN PCB is defective        copyir.com Line is disconnected        copyir.com
504    Polling is rejected from the remote station        copyir.com    No polling original is set        copyir.com
505    Polling XMT is rejected        copyir.com    No polling original is set        copyir.com
540    No response after transmitting 3rd CTC or DCN received        copyir.com    Incompatible interface        copyir.com
541    No response after transmitting 3rd EOR or received DCN        copyir.com    Line is faulty        copyir.com MAIN PCB is abnormal        copyir.com
542    No response to the 3rd RR transmitted or received DCN        copyir.com    Remote unit is abnormal        copyir.com
543    T5 timer (60 sec        copyir.com) elapsed without MCF        copyir.com    Remote unit is abnormal        copyir.com
544    Stopped Transmission after EOR Transmission        copyir.com    Line is faulty        copyir.com MAIN PCB is abnormal        copyir.com
550    Timer between frames in phase C has elapsed        copyir.com    Defective remote station        copyir.com
554    Transmitted ERR after receiving EOR        copyir.com    Line is faulty        copyir.com
580    Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF        copyir.com    Sub-address transmission to a unit that has no Sub-address function        copyir.com
623    No original was in the ADF        copyir.com (Built-in dialer engaged)    Operator removed the original from the ADF after dialling was completed        copyir.com Original was not set properly in the ADF        copyir.com
630    Redial count over        copyir.com    No dial tone detected        copyir.com Sensor dial tone is not detected        copyir.com (destination dependent) Busy tone is detected        copyir.com (destination dependent) T1 timer (35 +- 5 sec        copyir.com) elapsed without a signal from the receiver        copyir.com
631    “STOP” button was pressed during Auto Dialling        copyir.com    
634    Redial count over with no response or busy tone was not detected        copyir.com    Telephone line cable is disconnected        copyir.com Wrong number is dialled        copyir.com MAIN PCB is abnormal        copyir.com
638    Power turned off with applicable data in memory or during communication        copyir.com    Mains lead unplugged        copyir.com Power failure occurred        copyir.com
722    Failed to obtain the Network Parameters (such as: IP Address, Subnet Mask, Default Gateway IP Address, etc        copyir.com) from the DHCP server        copyir.com    LAN Cable is disconnected        copyir.com DHCP is not available        copyir.com (Contact the Network Administrator        copyir.com)
731    Dialer full while Relayed Transmission Request was received        copyir.com    Dial buffer for manual number dialling (70 stations) are being used        copyir.com
741    Dialling was not successful due to missing of the telephone number        copyir.com Occurs when deleting the telephone number of reserved One-Touch/Abbreviated dialling numbers with program keys        copyir.com    
800    The machine was requested to relay a document but has no Relay Hub capability    
815    Mailbox is full        copyir.com    
816    “The received Polling Password did not match        copyir.com The machine does not have Confidential Comm        copyir.com capability        copyir.com”    
825    Parameter settings of the initial sending station are not properly set        copyir.com    
870    Memory overflow occurred while storing documents into memory        copyir.com  