001 Timing Sensor did not turn ON within a certain period of time copyir.com 1 copyir.com Recording paper jammed when feeding from the 1st cassette copyir.com 2 copyir.com The 1st cassette is not installed copyir.com 3 copyir.com The 1st cassette has run out of paper copyir.com 4 copyir.com Recording paper is not loaded in the 1st cassette copyir.com 5 copyir.com Drive Clutch defective copyir.com 6 copyir.com Timing Sensor defective copyir.com
007 Recording paper did not completely exit from machine copyir.com 1 copyir.com Recording Paper Jam copyir.com 2 copyir.com Paper Exit Sensor defective copyir.com
012 The received data overflows from the maximum paper size of the paper feeding direction copyir.com Transmitter Document Jam copyir.com
021 The fixing temperature does not rise up even if the heating circuit is “ON” copyir.com The temperature of fuser exceeds upper limit of controllable temperature copyir.com The cooling fun in the unit does not rotate copyir.com 1 copyir.com Fuser Lamp connector is disconnected copyir.com 2 copyir.com Fuser Unit defective copyir.com 3 copyir.com Thermistor defective (Fuser Unit) copyir.com 4 copyir.com The cooling fun is defective copyir.com
030 Document is misfeeding copyir.com 1 copyir.com Document is not set properly copyir.com 2 copyir.com Defective Read Point Sensor copyir.com
031 Document paper is too long or jammed copyir.com Document length exceeds 2 metres copyir.com 1 copyir.com The document may jam copyir.com 2 copyir.com Defective Read Point Sensor copyir.com
041 Out of toner copyir.com 1 copyir.com No toner copyir.com 2 copyir.com Defective Toner Sensor copyir.com
043 Toner is getting low copyir.com 1 copyir.com Toner is getting low copyir.com 2 copyir.com Defective Toner Sensor copyir.com
045 Drum Cartridge is not installed copyir.com 1 copyir.com Toner Cartridge has not been installed copyir.com 2 copyir.com Defective Cartridge Sensor copyir.com
051 There is something wrong with DC motor copyir.com 1 copyir.com DC motor connector is disconnected copyir.com 2 copyir.com DC motor is defective copyir.com
054 The polygon motor does not become stable within the specified time when the polygon motor is “ON” copyir.com The behaviour of polygon motor rotation become unturned on the way copyir.com 1 copyir.com Polygon motor connector is disconnected copyir.com 2 copyir.com The polygon motor defective copyir.com 3 copyir.com LSU defective copyir.com
060 Printer Cover is open copyir.com 1 copyir.com Cover is not firmly closed copyir.com 2 copyir.com Connectors are not firmly connected copyir.com
068 Rear Cover is open copyir.com 1 copyir.com Cover is not firmly closed copyir.com 2 copyir.com Connectors are not firmly connected copyir.com
090 Malfunction of high voltage unit copyir.com 1 copyir.com HVPS is defective copyir.com 2 copyir.com Drum cartridge defective copyir.com
091 Cooling down the fuser unit copyir.com The fuser unit temperature is unstable copyir.com Wait until the “PLEASE WAIT“ is disappeared copyir.com This is normal operation copyir.com
092 The drum cartridge is reaching the end of its life copyir.com 1 copyir.com The drum cartridge is reaching the end of its life copyir.com
093 The unit is operated under the low-temperature environment which is not covered under warranty copyir.com 1 copyir.com Thermistor defective (Operation Panel Board) copyir.com
094 Malfunction of drum cartridge copyir.com 1 copyir.com Mixing Paddle defective copyir.com 2 copyir.com Defective Toner Sensor copyir.com
400 T1 timer (35+-5 sec copyir.com) elapsed without detecting 300 bps signal copyir.com Wrong number is dialled and the START button is pushed copyir.com Telephone line is disconnected while dialling copyir.com MAIN PCB (Modem) is defective copyir.com Receiver is defective copyir.com (It may only be transmitting CED)
401 DCN was returned from receiver while transmitter is waiting for CFR or FTT copyir.com Your machine’s ID Number is not programmed copyir.com Possible incompatibility or incorrect Password copyir.com
402 DCN was returned from receiver while transmitter is waiting for NSF/DIS copyir.com Receiver working in NON-STD mode only copyir.com (Possible incompatibility)
403 Transmitter had no polling function copyir.com “POLLED=ON” (polling XMT ready) is not set at the transmitter copyir.com Document to be transmitted is not placed at the transmitter copyir.com
404 Transmitter sent NSS (or DCS) followed by TCF three times, but the receiver did not respond copyir.com (CFR or FTT is usually returned) Receiver is defective copyir.com (Modem, MAIN PCB, etc copyir.com) MAIN PCB is defective copyir.com Receiver disconnects line during first NSS (or DCS) is transmitted copyir.com
405 Transmitter received FTT after it transmitted TCF at 2400bps copyir.com Received RTN after communicating at 2400 bps copyir.com Line quality is poor copyir.com (TCF is damaged due to line noise) Receiver is defective copyir.com (Modem, etc copyir.com) MAIN PCB is defective copyir.com
406 XMT-Password mismatched copyir.com RCV-Password mismatched copyir.com Selective RCV incomplete copyir.com XMT, RCV password does not match copyir.com Last 4 digits of TSI does not match with the last 4 digits of ONE-TOUCH, ABBR telephone number copyir.com
407 Transmitter received no response after it transmitted post message, such as EOP, MPS, EOM, etc copyir.com copyir.com copyir.comor received DCN copyir.com Receiver is defective copyir.com (No paper, paper jamming, etc copyir.com) Receiver ceased receiving because of excessive error copyir.com (Line quality is poor) MAIN PCB (Modem) is defective copyir.com
408 Transmitter received RTN after it transmitted EOP, MPS, or EOM copyir.com Receiver receives data with error copyir.com (Line quality is poor) Receiver is defective copyir.com (Modem, etc copyir.com) MAIN PCB is defective copyir.com
409 Transmitter receives PIN after it transmitted a post message, such as EOP, MPS, EOM, etc copyir.com Receiver receives data with error due to poor line quality, and receiving operator requests voice contact copyir.com Receiver is defective copyir.com (Modem, etc copyir.com) MAIN PCB is defective copyir.com
410 Received DCN while waiting for post command copyir.com (EOP, MPS, EOM, etc copyir.com) Interface or line is faulty copyir.com Transmitter is defective copyir.com
411 Received DCN after transmitting NSC copyir.com Transmitter is not ready for polling communication copyir.com Password does not match between transmitter and receiver copyir.com
412 No response within 12 seconds in NSS/ DCS/MPS wait state copyir.com (After transmitting FTT) Transmitter is defective copyir.com MAIN PCB is defective copyir.com
414 No response received after transmitting 3rd NSC copyir.com Password does not match between transmitter and receiver copyir.com Transmitter is defective copyir.com (No original, document jam, etc copyir.com)
415 Remote side attempted to receive message from your machine in polling communication copyir.com Inform the remote side that your machine does not have the polling transmission feature copyir.com
416 Receiver did not detect post command, such as EOP, MPS, EOM, etc copyir.com Transmitter is defective copyir.com Line quality is poor copyir.com (RTC signal is distorted due to line noise) MAIN PCB is defective copyir.com
417 Receiver returned RTN in response to post message copyir.com Line quality is poor copyir.com (There are excessive errors in received data) MAIN PCB is defective copyir.com
420 T1 timer (35 sec copyir.com) elapsed without detecting 300 bps signal copyir.com There is wrong incoming call copyir.com (non-facsimile communication) Transmitter is defective copyir.com MAIN PCB is defective copyir.com
421 Busy Tone is detected after sending NSF Signal copyir.com Remote station disconnected the line copyir.com Wrong number is dialled copyir.com
422 Content of NSF (or DIS) or NSC (or DTC) was invalid copyir.com There is an incompatibility copyir.com
427 DCN received to NSF/CSI/DIS transmitted copyir.com The interface is incompatible copyir.com
434 CD (response from Modem) did not turn OFF within 180 sec copyir.com after receiver detected FLAG signal copyir.com Remote unit is defective copyir.com MAIN PCB is defective copyir.com
436 DCN received after transmitting FTT copyir.com Transmitter is defective or incompatible copyir.com Line quality is poor copyir.com
456 Received relay transfer request or confidential document to distribute to an end receiving station or all confidential mailboxes are used copyir.com
490 Sum of error lines exceeded the limit (Function Parameter No copyir.com 70) of 64 lines copyir.com Line quality is poor copyir.com MAIN PCB is defective copyir.com
494 Interval between two EOLs was more than 10 sec copyir.com when receiver received message data copyir.com Transmitter is defective copyir.com Line quality is poor copyir.com (EOL is damaged due to line noise) MAIN PCB is defective copyir.com
495 During reception, CD turned OFF or continued ON for long time copyir.com During communication, lost loop – current copyir.com Line is disconnected copyir.com Transmitter is defective copyir.com MAIN PCB is defective copyir.com
501 Remote unit does not have compatible Modem copyir.com
502 During reception, CD turned OFF or continued ON for long time copyir.com During communication, lost loop – current copyir.com Line is disconnected copyir.com Transmitter is defective copyir.com MAIN PCB is defective copyir.com
503 CS of modem is not able to turn ON during training copyir.com MAIN PCB is defective copyir.com Line is disconnected copyir.com
504 Polling is rejected from the remote station copyir.com No polling original is set copyir.com
505 Polling XMT is rejected copyir.com No polling original is set copyir.com
540 No response after transmitting 3rd CTC or DCN received copyir.com Incompatible interface copyir.com
541 No response after transmitting 3rd EOR or received DCN copyir.com Line is faulty copyir.com MAIN PCB is abnormal copyir.com
542 No response to the 3rd RR transmitted or received DCN copyir.com Remote unit is abnormal copyir.com
543 T5 timer (60 sec copyir.com) elapsed without MCF copyir.com Remote unit is abnormal copyir.com
544 Stopped Transmission after EOR Transmission copyir.com Line is faulty copyir.com MAIN PCB is abnormal copyir.com
550 Timer between frames in phase C has elapsed copyir.com Defective remote station copyir.com
554 Transmitted ERR after receiving EOR copyir.com Line is faulty copyir.com
580 Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF copyir.com Sub-address transmission to a unit that has no Sub-address function copyir.com
623 No original was in the ADF copyir.com (Built-in dialer engaged) Operator removed the original from the ADF after dialling was completed copyir.com Original was not set properly in the ADF copyir.com
630 Redial count over copyir.com No dial tone detected copyir.com Sensor dial tone is not detected copyir.com (destination dependent) Busy tone is detected copyir.com (destination dependent) T1 timer (35 +- 5 sec copyir.com) elapsed without a signal from the receiver copyir.com
631 “STOP” button was pressed during Auto Dialling copyir.com
634 Redial count over with no response or busy tone was not detected copyir.com Telephone line cable is disconnected copyir.com Wrong number is dialled copyir.com MAIN PCB is abnormal copyir.com
638 Power turned off with applicable data in memory or during communication copyir.com Mains lead unplugged copyir.com Power failure occurred copyir.com
722 Failed to obtain the Network Parameters (such as: IP Address, Subnet Mask, Default Gateway IP Address, etc copyir.com) from the DHCP server copyir.com LAN Cable is disconnected copyir.com DHCP is not available copyir.com (Contact the Network Administrator copyir.com)
731 Dialer full while Relayed Transmission Request was received copyir.com Dial buffer for manual number dialling (70 stations) are being used copyir.com
741 Dialling was not successful due to missing of the telephone number copyir.com Occurs when deleting the telephone number of reserved One-Touch/Abbreviated dialling numbers with program keys copyir.com
800 The machine was requested to relay a document but has no Relay Hub capability
815 Mailbox is full copyir.com
816 “The received Polling Password did not match copyir.com The machine does not have Confidential Comm copyir.com capability copyir.com”
825 Parameter settings of the initial sending station are not properly set copyir.com
870 Memory overflow occurred while storing documents into memory copyir.com