001    Leading edge of the recording paper fails to reach the Timing Sensor       copyir.com (1st Cassette)    Recording paper jam       copyir.com Timing Sensor abnormal       copyir.com
002    Leading edge of the recording paper fails to reach the Timing Sensor       copyir.com (2nd Cassette)    Recording paper jam       copyir.com Timing Sensor abnormal       copyir.com
007    1       copyir.com Leading edge of the recording paper fails to reach the Paper Exit Sensor       copyir.com 2       copyir.com Recording paper has not completely passed the Paper Exit Sensor       copyir.com    Recording paper jam       copyir.com Paper Exit Sensor abnormal       copyir.com
010    No recording paper       copyir.com    No recording paper or paper is not set properly       copyir.com No Paper Sensor is defective       copyir.com
011    Paper Cassette is not installed properly       copyir.com    
012    The length of the received document is over 2 meter (78       copyir.com7in)       copyir.com    
021    Thermistor is abnormal       copyir.com Fuser Control is abnormal       copyir.com Fan is abnormal       copyir.com    Defective SC PCB       copyir.com Defective Fuser Unit, Power Supply Unit       copyir.com Defective Fan       copyir.com
030    Read Point Sensor does not go ON within 10 seconds after the document starts feeding       copyir.com    Document is not set properly       copyir.com Defective Read Point Sensor       copyir.com
031    Transmitting document was longer than 2 meter (or 78       copyir.com7 in)       copyir.com    The document may jam       copyir.com Defective Read Point Sensor       copyir.com
041    Out of toner       copyir.com    No toner       copyir.com Defective Toner Sensor       copyir.com
043    Low toner       copyir.com    Toner is getting low       copyir.com Defective Toner Sensor       copyir.com
045    No Toner Cartridge       copyir.com    Toner cartridge has not been installed       copyir.com Defective Toner Sensor (Cartridge Sensor)       copyir.com
051    Printer Motor abnormal       copyir.com    Connector not properly connected       copyir.com Defective Printer Motor       copyir.com Defective SC PCB       copyir.com
054    HSYNC abnormal       copyir.com Motor abnormal       copyir.com    Defective Laser Unit       copyir.com
060    Printer Cover is open       copyir.com    Cover is not firmly closed       copyir.com Connectors are not firmly connected       copyir.com
061    ADF Door is open       copyir.com    Door is not firmly closed       copyir.com Connectors are not firmly connected       copyir.com
200    Decoding process is not completed at the end of phase C       copyir.com    Defective SC PCB       copyir.com
212    Interface error occurred between the CPU and modem       copyir.com    Modem is defective       copyir.com (SC PCB) Software problem occurred       copyir.com (SC PCB)
301    System fault       copyir.com    Software problem occurred       copyir.com (SC PCB)
331    8-minutes timer error       copyir.com (Germany only)    
390    Interface error occurred between the machine and the PC       copyir.com    Firmware update error       copyir.com GDI print error       copyir.com (Perform the operation again)
400    T1 timer (35±5 sec       copyir.com) elapsed without detecting 300 bps signal       copyir.com    Wrong number is dialed and the START button is pushed       copyir.com Telephone line is disconnected while dialing       copyir.com SC PCB (Modem) or MJR PCB are defective       copyir.com Receiver is defective       copyir.com (It may only be transmitting CED)
401    DCN was returned from receiver while transmitter is waiting for CFR or FTT       copyir.com    Your machine’s ID Number is not programmed       copyir.com Possible incompatibility or incorrect Password       copyir.com
402    DCN was returned from receiver while transmitter is waiting for NSF/DIS       copyir.com    Receiver working in non-CCITT mode only       copyir.com (Possible incompatibility)
403    Transmitter had no polling function       copyir.com    “POLLED=ON” (polling XMT ready) is not set at the transmitter       copyir.com Document to be transmitted is not placed at the transmitter       copyir.com
404    Transmitter sent NSS (or DCS) followed by TCF three times, but the receiver did not respond       copyir.com (CFR or FTT is usually returned)    Receiver is defective       copyir.com (Modem, MJR PCB, etc       copyir.com) SC PCB or MJR PCB are defective       copyir.com Receiver disconnects line during first NSS (or DCS) is transmitted       copyir.com
405    Transmitter received FTT after it transmitted TCF at 2400bps       copyir.com Received RTN after communicating at 2400 bps       copyir.com    Line quality is poor       copyir.com (TCF is damaged due to line noise) Receiver is defective       copyir.com (Modem, etc       copyir.com) SC PCB or MJR PCB are defective       copyir.com
406    XMT-Password mismatched       copyir.com RCV-Password mismatched       copyir.com Selective RCV incomplete       copyir.com    XMT, RCV password does not match       copyir.com Last 4 digits of TSI does not match with the last 4 digits of ONE-TOUCH, ABBR telephone number       copyir.com
407    Transmitter received no response after it transmitted post message, such as EOP, MPS, EOM, etc       copyir.com       copyir.com       copyir.comor received DCN       copyir.com    Receiver is defective       copyir.com (No paper, paper jamming, etc       copyir.com) Receiver ceased receiving because of excessive error       copyir.com (Line quality is poor) SC PCB (Modem) or MJR PCB are defective       copyir.com
408    Transmitter received RTN after it transmitted EOP, MPS, or EOM       copyir.com    Receiver receives data with error       copyir.com (Line quality is poor) Receiver is defective       copyir.com (Modem, etc       copyir.com) SC PCB or MJR PCB are defective       copyir.com
409    Transmitter receives PIN after it transmitted a post message, such as EOP, MPS, EOM, etc       copyir.com    Receiver receives data with error due to poor line quality, and receiving operator requests voice contact       copyir.com Receiver is defective       copyir.com (Modem, etc       copyir.com) SC PCB or MJR PCB are defective       copyir.com
410    Received DCN while waiting for post command       copyir.com (EOP, MPS, EOM, etc       copyir.com)    Interface or line is faulty       copyir.com Transmitter is defective       copyir.com
411    Received DCN after transmitting NSC       copyir.com    Transmitter is not ready for polling communication       copyir.com Password does not match between transmitter and receiver       copyir.com
412    No response within 12 seconds in NSS/DCS/MPS wait state       copyir.com (After transmitting FTT)    Transmitter is defective       copyir.com SC PCB is defective       copyir.com
414    No response received after transmitting 3rd NSC       copyir.com    Password does not match between transmitter and receiver       copyir.com Transmitter is defective       copyir.com (No original, document jam, etc       copyir.com)
415    Remote side attempted to receive message from your machine in polling communication       copyir.com    Inform the remote side that your machine does not have the polling transmission feature       copyir.com
416    Receiver did not detect post command, such as EOP, MPS, EOM, etc       copyir.com    Transmitter is defective       copyir.com Line quality is poor       copyir.com (RTC signal is distorted due to line noise) SC PCB or MJR PCB are defective       copyir.com
417    Receiver returned RTN in response to post message       copyir.com    Line quality is poor       copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective       copyir.com
418    Receiver transmitted PIN in response to PRI-Q from transmitter       copyir.com (Transmitting operator requests voice contact)    Line quality is poor       copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective       copyir.com
420    T1 timer (35 sec       copyir.com) elapsed without detecting 300 bps signal       copyir.com    There is wrong incoming call       copyir.com(nonfacsimile communication) Transmitter is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
421    Busy Tone is detected after sending NSF Signal       copyir.com    Remote station disconnected the line       copyir.com Wrong number is dialed       copyir.com
422    Content of NSF (or DIS) or NSC (or DTC) was invalid       copyir.com    There is an incompatibility       copyir.com
427    DCN received to NSF/CSI/DIS transmitted    The interface is incompatible       copyir.com
433           copyir.comT       copyir.com30 Protocol abnormal       copyir.com    Defective remote station       copyir.com
434    CD (response from Modem) did not turn OFF within 180 sec       copyir.com after receiver detected FLAG signal       copyir.com    Remote unit is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
409    Transmitter receives PIN after it transmitted a post message, such as EOP, MPS, EOM, etc       copyir.com    Receiver receives data with error due to poor line quality, and receiving operator requests voice contact       copyir.com Receiver is defective       copyir.com (Modem, etc       copyir.com) SC PCB or MJR PCB are defective       copyir.com
410    Received DCN while waiting for post command       copyir.com (EOP, MPS, EOM, etc       copyir.com)    Interface or line is faulty       copyir.com Transmitter is defective       copyir.com
411    Received DCN after transmitting NSC       copyir.com    Transmitter is not ready for polling communication       copyir.com Password does not match between transmitter and receiver       copyir.com
412    No response within 12 seconds in NSS/DCS/MPS wait state       copyir.com (After transmitting FTT)    Transmitter is defective       copyir.com SC PCB is defective       copyir.com
414    No response received after transmitting 3rd NSC       copyir.com    Password does not match between transmitter and receiver       copyir.com Transmitter is defective       copyir.com (No original, document jam, etc       copyir.com)
415    Remote side attempted to receive message from your machine in polling communication       copyir.com    Inform the remote side that your machine does not have the polling transmission feature       copyir.com
416    Receiver did not detect post command, such as EOP, MPS, EOM, etc       copyir.com    Transmitter is defective       copyir.com Line quality is poor       copyir.com (RTC signal is distorted due to line noise) SC PCB or MJR PCB are defective       copyir.com
417    Receiver returned RTN in response to post message       copyir.com    Line quality is poor       copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective       copyir.com
418    Receiver transmitted PIN in response to PRI-Q from transmitter       copyir.com (Transmitting operator requests voice contact)    Line quality is poor       copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective       copyir.com
420    T1 timer (35 sec       copyir.com) elapsed without detecting 300 bps signal       copyir.com    There is wrong incoming call       copyir.com(nonfacsimile communication) Transmitter is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
421    Busy Tone is detected after sending NSF Signal       copyir.com    Remote station disconnected the line       copyir.com Wrong number is dialed       copyir.com
422    Content of NSF (or DIS) or NSC (or DTC) was invalid       copyir.com    There is an incompatibility       copyir.com
427    DCN received to NSF/CSI/DIS transmitted    The interface is incompatible       copyir.com
433           copyir.comT       copyir.com30 Protocol abnormal       copyir.com    Defective remote station       copyir.com
434    CD (response from Modem) did not turn OFF within 180 sec       copyir.com after receiver detected FLAG signal       copyir.com    Remote unit is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
436    DCN received after transmitting FTT       copyir.com    Transmitter is defective or incompatible       copyir.com Line quality is poor       copyir.com
456    Received relay transfer request or confidential document to distribute to an end receiving station or all confidential mailboxes are used       copyir.com    
459    Failed training in Phase C       copyir.com    Line quality is poor       copyir.com (Training signal is distorted due to line noise) SC PCB or MJR PCB are defective       copyir.com
490    Sum of error lines exceeded the limit (Function Parameter No       copyir.com 70) of 64 lines       copyir.com    Line quality is poor       copyir.com SC PCB or MJR PCB are defective       copyir.com
494    Interval between two EOLs was more than 10 sec       copyir.com when receiver received message data       copyir.com    Transmitter is defective       copyir.com Line quality is poor       copyir.com (EOL is damaged due to line noise) SC PCB or MJR PCB are defective       copyir.com
495    During reception, CD turned OFF or continued ON for long time       copyir.com During communication, lost loop – current       copyir.com    Line is disconnected       copyir.com Transmitter is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
496    CS of modem is not able to turn ON       copyir.com    SC PCB is defective       copyir.com
501    Remote unit does not have compatible Modem       copyir.com    
502    During reception, CD turned OFF or continued ON for long time       copyir.com During communication, lost loop – current       copyir.com    Line is disconnected       copyir.com Transmitter is defective       copyir.com SC PCB or MJR PCB are defective       copyir.com
503    CS of modem is not able to turn ON during training       copyir.com    SC PCB is defective       copyir.com Line is disconnected       copyir.com
504    Polling is rejected from the remote station       copyir.com    No polling original is set       copyir.com
505    Polling XMT is rejected       copyir.com    No polling original is set       copyir.com
540    No response after transmitting 3rd CTC or DCN received       copyir.com    Incompatible interface       copyir.com
541    No response after transmitting 3rd EOR or received DCN       copyir.com    Line is faulty       copyir.com MJR PCB abnormal       copyir.com
542    No response to the 3rd RR transmitted or received DCN       copyir.com    Remote unit is abnormal       copyir.com
543    T5 timer (60 sec       copyir.com) elapsed without MCF       copyir.com    Remote unit is abnormal       copyir.com
544    Stopped Transmission after EOR Transmission       copyir.com    Line is faulty       copyir.com MJR PCB abnormal       copyir.com
550    Timer between frames in phase C has elapsed       copyir.com    Defective remote station       copyir.com
554    Transmitted ERR after receiving EOR       copyir.com    Line is faulty       copyir.com
555    Transmitted PIN after receiving EOR       copyir.com    Line is faulty and Operator Call requested by RX side       copyir.com
570    Password or machine code did not match during remote diagnostic communication       copyir.com    
571    Remote unit did not have the remote diagnostic function       copyir.com    
580    Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF       copyir.com    Sub-address transmission to a unit that has no Sub-address function       copyir.com
581    Sub-address Password transmission to a unit that has their DIS bit 50 (NSF bit 156) OFF       copyir.com    Sub-address transmission to a unit that has no Sub-address function       copyir.com
601    ADF Door was opened during ADF transmission       copyir.com    
623    No original was in the ADF       copyir.com (Builtin dialer engaged)    Operator removed the original from the ADF after dialing was completed       copyir.com Original was not set properly in the ADF       copyir.com
630    Redial count over       copyir.com    No dial tone detected       copyir.com Sensor dial tone is not detected       copyir.com (destination dependent) Busy tone is detected       copyir.com (destination dependent) T1 timer (35±5 sec       copyir.com) elapsed without a signal from the receiver       copyir.com
631    “STOP” button was pressed during Auto Dialing       copyir.com    
634    Redial count over with no response or busy tone was not detected       copyir.com Note: U       copyir.comS       copyir.comA       copyir.com and Canadian models will redial only once if a busy tone is not detected       copyir.com    Telephone line cable is disconnected       copyir.com Wrong number is dialed       copyir.com SC or MJR PCB is abnormal       copyir.com
638    Power turned off with applicable data in memory or during communication       copyir.com    Power cord unplugged       copyir.com Power failure occurred       copyir.com
800    The machine was requested to relay a document but has no Relay Hub capability       copyir.com    
815    Mailbox is full       copyir.com    
816    “The received Polling Password did not match       copyir.com The machine does not have Confidential Comm       copyir.com capability       copyir.com”    
825    Parameter settings of the initial sending station are not properly set       copyir.com    
870    Memory overflow occurred while storing documents into memory       copyir.com    
880    File Access Error       copyir.com    
884    File Access Error       copyir.com  