کانون Canon CP2120
E000-0021 Within a temperature range of 50°C or lower as detected by the thermistor (TH1), the increase in temperature in 1 min is less than 3°C copyir.com The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-0031 Within a temperature range between 50°C and 190°C as detected by the thermistor, the increase in temperature within 30 sec is less than 5°C copyir.com The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-0040 During standby, the fixing temperature has dropped below 140°C copyir.com The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-0050 During printing, the fixing temperature has dropped below 140°C copyir.com The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-01 Main thermistor (TH1) The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-02 Sub thermistor (TH2) The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E000-03 The thermistor (TH1, TH2) has detected an open circuit copyir.com The fixing heater is faulty copyir.com The SSR is faulty copyir.com The fixing thermistor is faulty copyir.com The thermistor (TH1, TH2) has an open circuit copyir.com The thermal switch (TP1) has turned on copyir.com
E004-01 Main heater (H1)
SSR1 for the fixing heater is ON even though the fixing heater (H1, H2) is OFF copyir.com The SSR1 is faulty copyir.com
E004-02 Sub heater (H2)
SSR1 for the fixing heater is ON even though the fixing heater (H1, H2) is OFF copyir.com The SSR1 is faulty copyir.com
E005 The web solenoid (SL4) has turned on 300 times after the fixing web length sensor (S24) stopped detecting the flag copyir.com The fixing web has run out copyir.com The fixing web length sensor (S24) is faulty copyir.com
E006-0001 The fixing drawer cannot be detected even though the 24-V door is closed The fixing drawer has poor contact copyir.com The fixing assembly is absent copyir.com
E010-0001 The pickup main motor (M2) is released copyir.com The motor is checked every 10 msec from 3000 msec after it is started to when it is stopped copyir.com However, detection is not made when the front cover/delivery assembly cover/face-down delivery unit is released or when there is a fault in the power supply system copyir.com The main motor drive system has an excess load copyir.com The pickup main motor (M2)/delivery main motor (M16)/pedestal main motor (M19) is faulty copyir.com The serial driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E010-0002 The pedestal main motor (M16) is released copyir.com The motor is checked every 10 msec from 3000 msec after it is started to when it is stopped copyir.com However, detection is not made when the front cover/delivery assembly cover/face-down delivery unit is released or when there is a fault in the power supply system copyir.com The main motor drive system has an excess load copyir.com The pickup main motor (M2)/delivery main motor (M16)/pedestal main motor (M19) is faulty copyir.com The serial driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E010-0003 The pedestal main motor (M19) is released copyir.com The motor is checked every 10 msec from 2000 msec after it is started to when it is stopped copyir.com However, detection is not made when the front cover/delivery assembly cover/face-down delivery unit is released or when there is a fault in the power supply system copyir.com The main motor drive system has an excess load copyir.com The pickup main motor (M2)/delivery main motor (M16)/pedestal main motor (M19) is faulty copyir.com The serial driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E012 XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XX01 The target speed cannot be attained even when the frequency of the motor drive pulse is increased to the upper limit copyir.com XX02 The target speed cannot be attained even when the frequency of the motor drive pulse is decreased to the lower limit copyir.com XX03 The encoder signal from the motor is not generated for the following period of time: standard: 3 copyir.com69 msec, 1/2 speed: 7 copyir.com38 msec, 1/4 speed: 14 copyir.com75 msec XX04 The motor rotates in the direction opposite the desired direction copyir.com XX05 The spatial displacement is not corrected even when the frequency of the motor drive pulse is varied copyir.com XX06 The target speed cannot be attained even when the frequency of the motor drive pulse is varied copyir.com XX07 Not used copyir.com XX08 Not used copyir.com XX09 An error has occurred in the communication with the DC controller PCB copyir.com The drum motor (M3, M4, M5, M6) is faulty copyir.com The drum motor drive system has an excess load copyir.com The DC controller PCB is faulty copyir.com
E013-0001 The waste toner motor has locked and, as a result, an over-current has flowed into the motor control circuit copyir.com The waste toner feedscrew has locked copyir.com The waste toner feed motor is faulty copyir.com The transfer high-voltage PCB is faulty copyir.com The serial driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E013-0002 An open circuit has occurred in the waste toner motor copyir.com The waste toner feedscrew has locked copyir.com The waste toner feed motor is faulty copyir.com The transfer high-voltage PCB is faulty copyir.com The serial driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014- The target speed cannot be attained even when the frequency of the motor drive pulse is changed copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014-0001 The target speed cannot be attained even when the frequency of the motor drive pulse is increased to the upper limit copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014-0002 The target speed cannot be attained even when the frequency of the motor drive pulse is decreased to the lower limit copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014-0003 The encoder signal is not generated by the motor copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014-0004 The motor rotates in the direction opposite the desired direction copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E014-0009 An error has occurred in the communication with the DC controller PCB copyir.com The belt motor (M15) is faulty copyir.com The belt motor drive system has an excess load copyir.com The drum drive AC generation PCB is faulty copyir.com The transfer drive AC generation PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E020 XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XXA0During printing sequence, the difference between the maximum value and the minimum value of SIGNAL (9 samplings) is 0 copyir.com2 V (10) or less copyir.com XX80 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has dropped to 2 copyir.com344 V (120) or lower copyir.com XX81 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has risen to 2 copyir.com656 V (136) or higher copyir.com XX90 During printing sequence, the correction value for INIT-SIGNAL has changed to 0 (in service mode, ADJUST>DENS>SIGG-Y/M/ C/K) copyir.com XX91 During printing sequence, the correction value for INIT-SIGNAL has changed to 255 (in service mode, ADJUST>DENS>SIGG-Y/ M/C/K) copyir.com XXB0 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 0 copyir.com43 V (22) or lower copyir.com XXB1 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 4 copyir.com9 V (250) or higher copyir.com XXD0During printing sequence, the value of SIGNAL remains higher than INIT-SIGNAL entered as part of initial settings by 4 copyir.com71 V (240) or more continuously for 10 prints copyir.com XXE0 During printing sequence, the value of SIGNAL remains lower than INIT-SIGNAL entered as part of initial settings by 0 copyir.com98 V (50) or more continuously for 10 prints copyir.com The ATR sensor connector is disconnected copyir.com The developing cylinder/stirring screw fails to rotate copyir.com
E025-0101 The cartridge motor Y (M11) is found to have an over-current condition copyir.com The cartridge motor is faulty copyir.com
E025-0201 The cartridge motor M (M12) is fount to have an over-current condition copyir.com The cartridge motor is faulty copyir.com
E025-0301 The cartridge motor C (M13) is found to have an over-current condition copyir.com The cartridge motor is faulty copyir.com
E025-0401 The cartridge motor Bk (M14) is found to have an over-current condition copyir.com The cartridge motor is faulty copyir.com
E032 The Copy Data Controller-A1 or NE controller counter mechanism fails to operate copyir.com The Copy Data Controller-A1 or the NE controller is faulty or has an open circuit copyir.com The system controller PCB is faulty copyir.com
E041-0001 The fault was detected while the lifter was moving up copyir.com The deck lifter position sensor (PS104) does not detect the lifter within 60 sec after the deck lifter UP signal is generated copyir.com The output of the deck paper sensor (PS107) is ‘0’ when the output of the deck lifter position sensor (PS104) and that of the deck paper level sensor (PS108) are ‘1’ copyir.com The deck lifter motor (M102) is faulty copyir.com The deck driver PCB is faulty copyir.com A connected device is faulty copyir.com The deck lifter position sensor (PS104) is faulty copyir.com The deck paper sensor (PS107) is faulty copyir.com
E041-0002 The fault was detected while the lifter was moving down copyir.com The deck lifter position sensor (PS104) does not detect the lifter within 60 sec after the deck lifter UP signal is generated copyir.com The output of the deck paper sensor (PS107) is ‘0’ when the output of the deck lifter position sensor (PS104) and that of the deck paper level sensor (PS108) are ‘1’ copyir.com The deck lifter motor (M102) is faulty copyir.com The deck driver PCB is faulty copyir.com A connected device is faulty copyir.com The deck lifter position sensor (PS104) is faulty copyir.com The deck paper sensor (PS107) is faulty copyir.com
E043 The PLL lock signal (DMPLK) remains ‘1’ for 2 sec or more after the deck main motor drive signal is generated copyir.com The deck main motor (M101) is faulty copyir.com The deck driver PCB is faulty copyir.com A connected device is faulty copyir.com
E051-0001 The home position of the side registration sensor (S32) cannot be detected copyir.com The home position cannot be detected when 24-V power is turned on in response to the turning on of the main power switch or the opening and closing of the front cover/delivery assembly cover/ face-down delivery unit copyir.com The side registration sensor (S32) is faulty copyir.com The side registration motor (M17) is faulty copyir.com The duplex driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E070- The transfer belt sensor (S51) continues to detect the home position for the transfer belt copyir.com The transfer belt sensor (S51) is faulty copyir.com The transfer belt is deformed copyir.com The transfer high-voltage PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E070-0001 The transfer belt sensor (S51) cannot detect the home position of the transfer belt copyir.com The transfer belt sensor (S51) is faulty copyir.com The transfer belt is deformed copyir.com The transfer high-voltage PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E073-0001 The transfer unit cannot be detected when the front door is closed copyir.com The transfer drawer connector has poor contact copyir.com The transfer unit is absent copyir.com
E074-0001 The output of the transfer swing sensor (S49, S50) does not change even when the transfer unit is swung copyir.com The transfer swing sensor (S49, S50) is faulty copyir.com The transfer swing clutch (CL23) is faulty copyir.com The pickup main motor (M1) is faulty copyir.com The serial driver PCB is faulty copyir.com
E196 X=01: Y, X=02: M, X=03: C, X=04: Bk (X indicates the developing assembly color) YY=AA, 55, 00 (data in the presence of an error) 9XYYDrum kit cartridge EEPROM check error A101 System controller PCB DIMM (absent) A102 System controller PCB memory type (not SDRAM) A103 System controller PCB memory sequential error A104 System controller PCB memory capacity error (including a mix of 64 M and 128 M) A105 System controller PCB memory type (not of recommended type) A106 System controller PCB memory capacity error (duplex model, inadequate memory) A2ZZ RCON A memory error has occurred in the EEPROM copyir.com
E197 X=0: System controller PCB side 2: DC controller PCB side Ex01 Serial reception error (during data reception) Ex02 Reset on CPU of other party (during data reception) Ex03 During processing of transmission/reception data (during data reception) Ex04 Serial reception error (during standby) Ex05 Reset on CPU of other party (during standby) Ex06 During processing of transmission /reception data (during standby) 020F Connection time-out An error has occurred in communication among PCBs within the printer unit copyir.com
E202 During a home position search, the mirror base does not return to the home position within a specific period of time copyir.com The mirror base malfunctions copyir.com
E203 After scanning an original, the mirror mount does not return to the home position within a specific period of time copyir.com The home position is detected while the mirror base is moving copyir.com The scanner motor malfunctions copyir.com
E211 The thermistor reading is 0°C while the temperature is controlled to 70°C copyir.com The scanning lamp thermistor has an open circuit copyir.com
E215 The thermistor reading is 170°C or higher copyir.com The scanning lamp thermistor has an open circuit copyir.com
E216 The intensity sensor does not detect light 10 sec after the scanning lamp is turned on copyir.com The scanning lamp is faulty copyir.com The light intensity sensor is faulty copyir.com
E217 The temperature reading is not 70°C or higher 3 min after control to 70°C is started copyir.com The scanning lamp heater is faulty copyir.com
E218 The fluorescent lamp current does not flow within a specific period of time after the ON signal has been received copyir.com The scanning lamp is not mounted copyir.com The filament is broken copyir.com
E219 The thermistor reading is 150°C or higher while the scanning lamp is on The scanning lamp has reached the end of its life copyir.com
E240 An error has occurred in the communication between CPUs of the reader controller PCB and the system controller PCB copyir.com An error has occurred in the communication between CPUs of the reader controller PCB and the system controller PCB copyir.com
E243 An error has occurred in the communication between CPUs of the reader controller PCB and the control panel copyir.com An error has occurred in the communication between CPUs of the reader controller PCB and the control panel copyir.com
E244 x=0: Pickup assembly PCB, 1: Serial driver PCB, 2: Duplex driver PCB y=0 to 7: Port of each PCB xy01 Connection check error When the main power switch is turned on, communication with each PCB cannot be established copyir.com xy02 Parity error After communication with each PCB has been established, a parity error has occurred continuously 5 times copyir.com xy04 Sub station reset response time-out error When the main power switch is turned on, each PCB cannot be reset (reset processing error) copyir.com xy05 Connection check result response time-out error When the main power switch is turned on, communication with each PCB cannot be established copyir.com xy06 Transmission end response time-out error After communication has been established with each PCB, the absence of responce has occurred continuously 5 times copyir.com (monitoring at tall times) The pickup assembly PCB is faulty copyir.com The serial driver PCB is faulty copyir.com The duplex driver PCB is faulty copyir.com The DC controller PCB is faulty copyir.com
E351 An error has occurred in the anti-counterfeit PCB copyir.com An error has occurred in the anti-counterfeit PCB copyir.com
E401 The sensor does not turn on and off twice or more within 1 sec copyir.com The pickup motor (M1) fails to rotate copyir.com The pickup roller sensor (S5) is faulty copyir.com
E402 The number of clock pulses within 200 msec is lower than a specific value copyir.com The belt motor (M3) fails to rotate copyir.com The belt motor lock sensor (S10) is faulty copyir.com
E404 The number of clock pulses within 200 msec is lower than a specific value copyir.com The feed motor (M2) fails to rotate copyir.com The feed motor clock sensor (S9) is faulty copyir.com
E411 In the absence of paper, the output of the sensor is 2 copyir.com3 V or higher copyir.com The original tray power sensor (S1) is faulty copyir.com The registration sensor (S3) is faulty copyir.com
E500 The communication between the host machine and the sorter is disrupted copyir.com (This error is detected by the host machine copyir.com) Data communication is faulty
E503-0003 An error is detected in the communication with the saddle sitcher copyir.com A communication error has been detected copyir.com
E504-0004 The adjustment of the sensor made using a DIP switch is faulty copyir.com The output of the height sensor (PS1) is faulty copyir.com
E505-0001 At power-on, the check sum value is found to be faulty copyir.com The backup RAM is faulty copyir.com
E510 After the motor drive signal has been generated, the input signal of the nonsort motor clock sensor (PI10) does not change within 60 msec copyir.com The no-sort motor (M6) does not rotate copyir.com
E512-0001 At the start of operation, the target number of clock pulses cannot be obtained from the delivery motor clock copyir.com The delivery motor is faulty copyir.com The delivery motor clock sensor (PI10) is faulty copyir.com
E512-0002 During feeding, clock pulses are absent for a period equivalent of 200 mm copyir.com The delivery motor is faulty copyir.com The delivery motor clock sensor (PI10) is faulty copyir.com
E525 Auto adjustment of the bin inside paper sensor (S1, S2) fails, or the auto adjustment value has an error copyir.com Auto adjustment of the bin inside paper sensor (S1, S2) is faulty copyir.com
E530 After the motor drive signal has been generated, the input signal of the guide bar HP sensor (PI3) does not change within 200 msec copyir.com The guide bar swing motor (M3) fails to rotate copyir.com
E530-0001 The alignment plate does not leave the alignment plate home position sensor even when the alignment motor has been driven for 2 sec copyir.com The alignment motor (M3) is faulty copyir.com The alignment plate home position sensor (PI6) is faulty copyir.com
E530-0002 The alignment plate does not return to the alignment plate home position sensor even when the alignment motor has been driven for 2 sec copyir.com The alignment motor (M3) is faulty copyir.com The alignment plate home position sensor (PI6) is faulty copyir.com
E531 The input signal from the stapler unit HP switch (MS4) does not change for 1000 msec or more copyir.com While the stapler unit is rotating clockwise, the home position is not detected within 600 msec copyir.com In addition, the home position cannot be detected within 600 msec when the motor is rotated in reverse copyir.com The stapler unit swing motor (M4) fails to rotate copyir.com The stapler motor (M5) fails to rotate copyir.com
E531-0001 The stapler does not leave the stapling home position even when the stapler motor has been driven for 0 copyir.com5 sec copyir.com The stapler motor (M6) is faulty copyir.com The stapler home position sensor detecting switch (MS7) is faulty copyir.com
E531-0002 The stapler does not return to the stapling home position even when the stapler motor has been driven for 0 copyir.com5 sec copyir.com The stapler motor (M6) is faulty copyir.com The stapler home position sensor detecting switch (MS7) is faulty copyir.com
E532-0001 The stapler does not leave the stapler shift home position sensor even when the stapler shift motor has been driven for 4 sec copyir.com The stapler shift motor (M4) is faulty copyir.com The stapler shift home position sensor (PI7) is faulty copyir.com
E532-0002 The stapler shift home position cannot be detected even when the stapler shift motor has been driven for 4 sec copyir.com The stapler shift motor (M4) is faulty copyir.com The stapler shift home position sensor (PI7) is faulty copyir.com
E535-0001 The swing guide closed detecting switch does not turn on even when the delivery motor is rotated in reverse for 1 sec copyir.com The delivery motor (M2) is faulty copyir.com The swing guide open sensor (PI18) is faulty copyir.com
E535-0002 The swing guide open detecting sensor does not turn on even when the delivery motor is rotated in reverse for 1 sec copyir.com The safety area switch (MS3) is faulty copyir.com The swing guide open detecting switch (MS6) is faulty copyir.com
E535-0003 When the tray 1/2 is in the safety area switch OFF position, the swing guide closed detecting switch is found to be off copyir.com The delivery motor (M2) is faulty copyir.com The swing guide closed detecting switch 2 (MS6) is faulty copyir.com
E540-0001 The ascent operation does not end 15 sec after the tray lift motor is started copyir.com The tray home position cannot be detected even when the tray lift motor has been driven for 15 sec copyir.com The tray lift motor (M5) is faulty copyir.com The tray lift motor clock sensor 1/2 (PI19/PI20) is faulty copyir.com The tray home position sensor (PI8) is faulty copyir.com
E540-0002 The tray upper limit detecting switch is found to be on while the tray is moving up copyir.com The tray paper limit detecting switch (MS4) is faulty copyir.com
E540-0003 There is no clock pulse from the clock sensor 1/2 for 200 msec or more when the try lifter motor is driven copyir.com The tray lifter motor (M5) is faulty copyir.com The tray lifter motor clock sensor 1/2 (PI19/PI20) is faulty copyir.com
E584-0001 The shutter closed detecting switch does not turn on even when the feed motor has been rotated in reverse for 1 sec or more copyir.com The feed motor (M1) is faulty copyir.com The shutter closed detecting switch (MS4) is faulty copyir.comPI20
E584-0002 The shutter open sensor does not turn on even when the feed motor is rotated in reverse for 1 sec or more copyir.com The feed motor (M1) is faulty copyir.com The shutter open sensor (PI5) is faulty copyir.com
E584-0003 When the tray 1/2 is in the safety area switch OFF position, the shutter closed detecting switch is found to be off copyir.com The safety area switch (MS3) is faulty copyir.com The shutter closed detecting sensor (MS4) is faulty copyir.com
E5F0-0001 The paper positioning plate home position sensor does not turn on even when the paper positioning plate motor has been driven for 1 copyir.com25 sec or more copyir.com The positioning plate motor (M4S) is faulty copyir.com The power positioning plate home position sensor (PI7S) is faulty copyir.com
E5F0-0002 The paper positioning plate home position sensor does not turn off even when paper positioning plate motor has been driven for 1 sec or more copyir.com The positioning plate motor (M4S) is faulty copyir.com The power positioning plate home position sensor (PI7S) is faulty copyir.com
E5F1-0001 The number of detention pulses of the folding motor clock sensor drops to a specific value or lower copyir.com The folding motor (M2S) is faulty copyir.com The folding motor clock sensor (PI4S) is faulty copyir.com
E5F2-0001 The guide home position sensor does not turn on even when the guide motor has been driven for 0 copyir.com4 sec or more copyir.com The guide motor (M3S) is faulty copyir.com The guide home position sensor (PI13S) is faulty copyir.com
E5F2-0002 The guide home position sensor does not turn off even when the guide motor has been driven for 1 sec or more copyir.com The guide motor (M3S) is faulty copyir.com The guide home position sensor (PI13S) is faulty copyir.com
E5F3-0001 The alignment plate home position sensor does not turn on even when the alignment motor has been driven for 0 copyir.com5 sec or more copyir.com The alignment motor (M5S) is faulty copyir.com The alignment plate home position sensor (PI5S) is faulty copyir.com
E5F3-0002 The alignment plate home position sensor does not turn off even when the alignment motor has been driven for 1 sec or more copyir.com The alignment motor (M5S) is faulty copyir.com The alignment plate home position sensor (PI5S) is faulty copyir.com
E5F4-0001 The stitching home position switch does not turn off even when the stitching motor (rear) is rotated clockwise for 0 copyir.com5 sec or more copyir.com The stitch motor (rear, M6S) is faulty copyir.com The stitching home position switch (rear, PS2S) is faulty copyir.com
E5F4-0002 During jam recovery, the stitching home position switch does not turn on even when the stitching motor (rear) is rotated counterclockwise for 0 copyir.com5 sec or more copyir.com The stitch motor (rear, M6S) is faulty copyir.com The stitching home position switch (rear, PS2S) is faulty copyir.com
E5F5-0001 The stitching home position switch does not turn off even when the stitching motor (front) is rotated clockwise for 0 copyir.com5 sec or more copyir.com The stitching motor (front, M7S) is faulty copyir.com The stitching motor operating home position switch (front, PS4S) is faulty copyir.com
E5F5-0002 During jam recovery, the stitching home position switch does not turn on even when the stitching motor (front) is rotated counterclockwise for 0 copyir.com5 sec or more copyir.com The stitching motor (front, M7S) is faulty copyir.com The stitching motor operating home position switch (front, PS4S) is faulty copyir.com
E5F6-0001 While the paper push-on plate is moving from the leading edge to the home position, the paper push-on plate home position sensor does not turn on even when the paper push-on plate motor has been driven for 0 copyir.com3 sec or more copyir.com The paper push-on plate motor (M8S) is faulty copyir.com The paper push-on plate home position sensor (PI14S) is faulty copyir.com
E5F6-0002 While the paper push-on plate is moving to the leading edge, the paper push-on plate home position sensor does not turn off even when the paper push-on plate motor has been driven for 1 copyir.com0 sec or more copyir.com The paper push-on plate motor (M8S) is faulty copyir.com The paper push-on plate leading edge position sensor (PI15S) is faulty copyir.com
E5F6-0003 When the paper push-on plate is moving from the leading edge to the home position, the paper push-on plate leading edge sensor does not turn on even when the paper push-on plate motor has been driven for 1 copyir.com0 sec or more copyir.com The paper push-on plate motor (M8S) is faulty copyir.com The paper push-on plate leading edge position sensor (PI15S) is faulty copyir.com
E5F6-0004 The number of detection pulse of the paper push-on plate motor clock sensor is lower than a specific value copyir.com The paper push-on plate motor (M8S) is faulty copyir.com The paper push-on plate motor clock sensor (PIS) is faulty
E5F6-0005 The paper push-on plate leading edge position sensor does not turn on even when the paper push-on plate motor has been driven for 0 copyir.com3 sec or more after the paper push-on plate home position sensor is turned off copyir.com The paper push-on plate motor (M8S) is faulty copyir.com The paper push-on leading edge position sensor (PI15S) is faulty copyir.com
E5F8-0001 The connector of the guide home position sensor is found to be disconnected copyir.com The guide home position sensor (PI13S) has a faulty connector copyir.com
E5F8-0002 The connector of the paper push-on plate home position sensor is found to be disconnected copyir.com The paper push-on plate home position sensor (PI14) has a faulty connector copyir.com
E5F8-0003 The connector of the paper push-on plate leading edge sensor is found to be disconnected copyir.com The paper push-on plate leading edge sensor (PI15S) has a faulty connector copyir.com
E5F9-0001 While the following three photointerrupters for covers have identified that the doors are closed, the inlet door open detention switch identifies the door to be open for 1 sec or more from the start of copying or the start of copier initial rotation copyir.com Inlet door sensor (PI9S) Front door open sensor (PI2S) Delivery door open sensor (PI3S) The inlet door open detecting switch (MS1S) is faulty copyir.com The inlet door sensor (PI9S) is faulty copyir.com
E5F9-0002 While the following three photointerrupters for covers have identified that the doors are closed, the front door open detecting switch identifies the front door to be open for 1 sec or more from the start of copying or the start of copier initial rotation: Inlet door sensor (P19S) Front door open sensor (PI2S) Delivery door open sensor (PI3S) The front door open detecting switch (MS2S) is faulty copyir.com The front door open sensor (PS2S) is faulty copyir.com
E5F9-0003 While the following three photointerrupters for covers have identified that the doors are closed, the delivery door open detecting switch identifies the delivery door to be open for 1 sec or more from the start of copying or the start of initial rotation copyir.com Inlet door sensor (PI9S) Font door open sensor (PI2S) Delivery door open sensor (PI3S) The delivery door open detecting switch (MS3S) is faulty copyir.com The delivery door open sensor (PI3S) is faulty copyir.com
E621 An error has been detected in the communication between editor and host machine copyir.com The editor has an error copyir.com
E624 An error has occurred in the communication with the editor digitizer copyir.com The editor has an error copyir.com
E625 An error has occurred in the editor RAM copyir.com The editor has an error copyir.com
E626 An error has occurred in the LCD of the editor copyir.com The editor has an error copyir.com
E627 An error has occurred in the ASIC of the editor copyir.com The editor ha an error copyir.com
E628 An error has occurred in the IPC of the editor copyir.com The editor has an error copyir.com
E629 A sequential error has occurred in the editor copyir.com The editor has an error copyir.com
E677-0001 DPRAM size error In communication for initialization, the DPRAM size returned by the PDL board to the host machine has an error copyir.com (The host machine is aware of the DPRAM size in advance; the DPRAM is a dual-port RAM used for communication between the host machine and the PDL board, and is mounted on the PDL board copyir.com) The connection between the host machine and the PDL board is faulty copyir.com The system software is faulty copyir.com The hard disk is faulty copyir.com The PDL board is faulty copyir.com The system controller PCB of the host machine is faulty copyir.com
E677-0002 Initialization communication error In communication for initialization, the contents of communication returned by the PDL board to the host machine have an error and, therefore, communication cannot be established copyir.com The connection between the host machine and the PDL board is faulty copyir.com The system software is faulty copyir.com The hard disk is faulty copyir.com The PDL board is faulty copyir.com The system controller PCB of the host machine is faulty copyir.com
E677-0004 PDL board disconnection After the connection of the PDL board is recognized at power-on, the PDL board is disconnected copyir.com During power-up, monitoring is executed at intervals of 2 min; however, if the CPU is not on (sleep state or the like), no error will be identified even if the PDL board is discontented copyir.com If the PDL board is disconnected in sleep state, the absence of the PDL board will be recognized at the start of the CPU copyir.com The connection between the host machine and the PDL board is faulty copyir.com The system software is faulty copyir.com The hard disk is faulty copyir.com The PDL board is faulty copyir.com The system controller PCB of the host machine is faulty copyir.com
E677-0080 Communication error An error in communication has occurred after the communication between the host machine and the PDL board has been established copyir.com For communication related to the sleep mode (power control) of the host machine, the response from the PDL board is disrupted for 2 min or more copyir.com The connection between the host machine and the PDL board is faulty copyir.com The system software is faulty copyir.com The hard disk is faulty copyir.com The PDL board is faulty copyir.com The system controller PCB of the host machine is faulty copyir.com
E677-0101 cooling fan error The rotation of the cooling fan slows down or the absence (disconnection) of the fan is detected copyir.com The revolution of the fan is monitored at all times as long as the fan is rotating copyir.com (The cooling fan keeps rotating while the main switch remains on copyir.com) The connector is disconnected copyir.com The cooling fan is faulty copyir.com The PDL board is faulty copyir.com The host machine is faulty copyir.com The system controller PCB is faulty copyir.com
E710 At power-on, synchronization fails in the IPC communication between the reader unit and DADF/editor within a specific period of time (3 sec) copyir.com The DADF/editor IPC communication (initialization) has an error copyir.com
E711 At power-on, an IPC communication error has occurred 10 times or more between the reader unit and DADF/editor within a specific period of time (1 copyir.com5 sec) copyir.com The DADF/editor has an IPC communication error copyir.com
E712 The IPC communication with the reader unit is interrupted for a specific period of time (5 sec) or more copyir.com The DADF/editor has an IPC communication error copyir.com
E717 When the copy start signal is generated, the count pulse is not detected by the Copier Controller-A1 or the NE controller within a specific period of time copyir.com After connection, the Copy Data Controller-A1 or the NE Controller is disconnected copyir.com The Copy Data Controller-A1 or the NE Controller is faulty or has an open circuit copyir.com The system controller PCB is faulty copyir.com
E800-0001 The shut-off relay of the main power switch (SW1) is found to have an open circuit copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E800-0002 The AC relay (RL1) is found to have an open circuit copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E800-0003 The DC relay (RL2) is found to have an open circuit copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E800-0004 +24 VRET does not change to +24 V even when the front door, fixing door, and face-down delivery unit are all closed copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E805-0001 The fixing fan (FM1) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0002 The delivery fan (FM2) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0003 The machine cooling fan (FM4) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0004 The power supply cooling fan (FM6) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0005 The de-curling fan (FM7) is found have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0006 The kit drive cooling fan (FM10) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0007 The transfer motor cooling fan (F13) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E809 The reader unit power supply fan (FM1) is faulty copyir.com The reader unit power supply fan (FM1) is faulty copyir.com
E810 XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XX01 The photosensitive drum unit is absent copyir.com XX02 The wrong photosensitive drum unit is mounted (wrong color) copyir.com XX03 The photosensitive drum is wrongly installed (wrong country model) copyir.com The photosensitive drum unit is faulty copyir.com
E800-0003 The DC relay (RL2) is found to have an open circuit copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E800-0004 +24 VRET does not change to +24 V even when the front door, fixing door, and face-down delivery unit are all closed copyir.com The electric system has an error copyir.com The DC controller PCB is faulty copyir.com
E805-0001 The fixing fan (FM1) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0002 The delivery fan (FM2) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0003 The machine cooling fan (FM4) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0004 The power supply cooling fan (FM6) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0005 The de-curling fan (FM7) is found have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0006 The kit drive cooling fan (FM10) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E805-0007 The transfer motor cooling fan (F13) is found to have locked copyir.com The fixing fan has an error copyir.com The delivery fan has an error copyir.com The machine cooling fan has an error copyir.com The power supply cooling fan has an error copyir.com The decurling fan has an error copyir.com The kit drive cooling fan has an error copyir.com The transfer motor cooling fan has an error copyir.com
E809 The reader unit power supply fan (FM1) is faulty copyir.com The reader unit power supply fan (FM1) is faulty copyir.com
E810 XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XX01 The photosensitive drum unit is absent copyir.com XX02 The wrong photosensitive drum unit is mounted (wrong color) copyir.com XX03 The photosensitive drum is wrongly installed (wrong country model) copyir.com The photosensitive drum unit is faulty copyir.com