E000-0000    The reading of the main thermistor does not reach 30C 1 sec after the main power switch is turned on  copyir.com Or, it does not reach 70C 2 sec thereafter    The fixing film unit is faulty  copyir.com The main thermistor has an open circuit  copyir.com The fixing heater has an open circuit  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com To reset the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR  copyir.com    1  copyir.com Connector Is the connector of the fixing assembly connected? a  copyir.com main power supply PCB (J8) <-> relay connector <-> heater b  copyir.com DC controller PCB (J320) <-> relay connector <-> thermistor NO: Connect the connector  copyir.com 2  copyir.com Fixing film unit (thermistor) Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectosr (4-pin) of the thermistor for electrical continuity  copyir.com Is it W (open)? YES: The heater has an open circuit, or the thermal switch is open  copyir.com Replace the fixing film unit  copyir.com 4  copyir.com Main power supply PCB, DC controller PCB Press the Start key  copyir.com Is the drive voltage of the heater supplied by the connector J8 of the main power supply PCB? Main heater: between J8-1 (FSR1) and J8-5 (FSR COM) Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM) YES: The heater drive power supply is faulty  copyir.com Replace the main power supply PCB  copyir.com NO: The thermistor control mechanism is faulty  copyir.com Replace the DC controller PCB  copyir.com
E001-0000    The main thermistor detects 250C or higher    The fixing film unit is faulty (i  copyir.come  copyir.com, the thermistor has a short circuit)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR  copyir.com    Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical continuity  copyir.com Is it 0 W (short circuit)? YES: The thermistor has a short circuit  copyir.com Replace the fixing film unit  copyir.com If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub thermistor  copyir.com 2  copyir.com Main power supply PCB, DC controller PCB Try replacing the main power supply PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E001-0001    The main thermistor or the sub thermistor detects overheating (hardware circuit detection)    The fixing film unit is faulty (i  copyir.come  copyir.com, the thermistor has a short circuit)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR  copyir.com    Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical continuity  copyir.com Is it 0 W (short circuit)? YES: The thermistor has a short circuit  copyir.com Replace the fixing film unit  copyir.com If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub thermistor  copyir.com 2  copyir.com Main power supply PCB, DC controller PCB Try replacing the main power supply PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E001-0002    The sub thermistor detects about 295C or higher    The fixing film unit is faulty (i  copyir.come  copyir.com, the thermistor has a short circuit)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR  copyir.com    Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical continuity  copyir.com Is it 0 W (short circuit)? YES: The thermistor has a short circuit  copyir.com Replace the fixing film unit  copyir.com If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub thermistor  copyir.com 2  copyir.com Main power supply PCB, DC controller PCB Try replacing the main power supply PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E002-0000    The temperature of the fixing film is as follows:
has exceeded 100C, but does not reach 115C within 1 sec thereafter  copyir.com has exceeded 140C, but does not reach 150C within 1 sec thereafter  copyir.com has exceeded 160C, but does not reach 165C within 1 sec thereafter    The fixing film unit is faulty (i  copyir.come  copyir.com, the main thermistor TH1 has poor contact, or the fixing heater is faulty)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>FCLEAR>ERR  copyir.com    1  copyir.com State Turn on the power switch, and clear E002/E003  copyir.com Thereafter, turn off and then on the power switch  copyir.com Does the fixing heater operate? NO: See “The fixing heater fails to operate  copyir.com” 2  copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring  copyir.com 3  copyir.com Fixing film unit, DC controller PCB Try replacing the fixing film unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E003-0000    The main thermistor reading is lower than 140C when paper is moved    The fixing film unit is faulty (i  copyir.come  copyir.com, the main thermistor (TH1) has poor contact or has an open circuit; or, the fixing heater is faulty)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR  copyir.com    1  copyir.com State Turn on the power switch, and clear E002/E003  copyir.com Thereafter, turn off and then on the power switch  copyir.com Does the fixing heater operate? NO: See “The fixing heater fails to operate  copyir.com” 2  copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring  copyir.com 3  copyir.com Fixing film unit, DC controller PCB Try replacing the fixing film unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E003-0001    Low fixing temperature detection after standby (by sub thermistor)    The fixing film unit is faulty (i  copyir.come  copyir.com, the main thermistor (TH1) has poor contact or has an open circuit; or, the fixing heater is faulty)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR  copyir.com    1  copyir.com State Turn on the power switch, and clear E002/E003  copyir.com Thereafter, turn off and then on the power switch  copyir.com Does the fixing heater operate? NO: See “The fixing heater fails to operate  copyir.com” 2  copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring  copyir.com 3  copyir.com Fixing film unit, DC controller PCB Try replacing the fixing film unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E007-0000    An error in the rotation of the fixing film is detected  copyir.com
The reading of the main thermistor is 100C or higher and, in addition, the fixing film sensor does not detect the rotation of the film for 6 sec or more while the fixing motor is driven    The fixing film sensor (PS45) is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR    1  copyir.com Wiring Are the wring and the connectors connected securely? DC controller PCB (J311) <-> relay connector <-> fixing film sensor NO: Connect the wiring and the connectors  copyir.com 2  copyir.com Fixing film sensor Check the fixing film rotation signal  copyir.comWhen the fixing motor is rotating, is the film rotation detection signal sent by the fixing film sensor to the concoctor J311 of the DC controller PCB? Film rotation detection signal: 5V pulse signal between J311-A9 (FILM_ROT_D) and J311-A8 (GND); at intervals of 100 msec ON and 440 msec OFF NO: If the fixing film is normal, replace the sensor  copyir.com 3  copyir.com Fixing film unit, DC controller PCB Is there a fault in the fixing film edge rotation detection mechanism? YES: Replace the fixing film unit  copyir.com NO: Replace the DC controller PCB  copyir.com
E010-0000    After the main motor drive signal is generated, the clock signal does to arrive within 1  copyir.com3 sec    The main motor (M2) is faulty  copyir.com the DC controller PCB is faulty  copyir.com    1  copyir.com Connector Is the connector of the main motor connected? NO: Connect the connector  copyir.com 2  copyir.com Main power supply PCB Is the drive voltage (24 V) of the main motor supplied by the main power supply PCB? Main power supply PCB: between J202-1 (24VU1-SW) and J202-2 (OVU1) NO: Replace the main power supply PCB  copyir.com 3  copyir.com Main controller (M2), DC controller PCB Press the Start key  copyir.com Is the lock signal of the main motor present at the connector J308 on the DC controller PCB? Lock signal: J318-A10 (MM_LOCK) YES: Replace the main motor  copyir.com NO: Check the wiring; if normal, replace the DC controller PCB  copyir.com
E014-000    After the fixing motor drive signal is generated, the clock signal does not arrive within 1  copyir.com3 sec    The fixing motor (M19) is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Is the connector of the fixing motor connected? NO: Connect the connector  copyir.com 2  copyir.com Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB  copyir.com 3  copyir.com Fixing motor (M19), DC controller PCB Press the Start key  copyir.com Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about 5 V? YES: Replace the fixing motor  copyir.com NO: Replace the DC controller PCB  copyir.com
E019-0000    The waste toner case is full of waste toner    The waste toner case is full  copyir.com The waste toner case full detection mechanism is soiled  copyir.com The waste toner sensor is faulty  copyir.com The DC controller PCB is faulty  copyir.com Caution To clear the error, dispose of the waste toner, and turn off and then on the main power switch  copyir.com    1  copyir.com Waste toner case full detection mechanism Remove the waste toner case, and turn off and then on the main power switch  copyir.com Is ‘E019’ absent? YES: The waste toner case full detection assembly is soiled with toner  copyir.com Clean both inside and outside of area A of the waste toner case with alcohol  copyir.com Make sure that no dirt remains inside and outside the area around the round recess  copyir.com 2  copyir.com Waste toner full sensor, DC Controller PCB Try replacing the waste toner case full sensor  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E032-0001    The DA unit connection is disconnected (after connection)  copyir.com    The DA unit is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connector Is the DA unit connected securely? NO: Connect it securely  copyir.com 2  copyir.com DA controller, Main controller PCB Try replacing the DA unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E051-0000    At start-up, home position is not detected when the horizontal registration assembly is moved 100 mm in the direction of home position    The horizontal home position sensor is faulty  copyir.com The horizontal registration motor is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Are the connectors of the horizontal registration home position sensor and the horizontal registration motor connected? a  copyir.com DC controller PCB (J304) <-> relay connector <-> horizontal registration home position sensor b  copyir.com DC controller PCB (J304) <-> relay connector <-> horizontal registration motor NO: Connect the connectors  copyir.com 2  copyir.com Sensor lever (damage and interference), Sensor Is abnormal noise heard from the horizontal registration assembly in keeping with the motor rotation? YES: a  copyir.com The horizontal registration assembly is out of place because of damage to the sensor lever  copyir.com Replace the sensor lever  copyir.com b  copyir.com The horizontal registration assembly malfunctions because of the presence of foreign matter  copyir.com Remove the foreign matter  copyir.com c  copyir.com The sensor is faulty and cannot detect home position  copyir.com Replace the sensor  copyir.com 3  copyir.com Horizontal registration motor, DC controller PCB Is the horizontal registration motor control signal generated by the DC controller PCB? J304-1/2: 24 V, J304-3/4/5/6: motor excitation signal YES: The horizontal registration motor is faulty  copyir.com Replace the motor  copyir.com NO: Replace the DC controller PCB  copyir.com
E064-0000    The presence of a high-voltage error is communicated by the composite power supply PCB (The output for primary charging, developing, or transfer has deviated from a specific level of voltage)    The contact has poor connection  copyir.com The wiring is faulty  copyir.com The composite power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com proce    1  copyir.com Contact Is any of the contacts of the primary charging roller, developing assembly, or transfer charging roller soiled? Or, is there poor contact? YES: Clean the contact, and set it once again  copyir.com 2  copyir.com Wiring Is the wiring between the contacts for the following normal: DC controller PCB (J301), composite power supply PCB (J136), primary charging roller, developing assembly, transfer charging roller? a  copyir.com DC controller PCB (J301) <-> composite power supply PCB (J136) b  copyir.com composite power supply PCB (J130-7) <-> primary charging roller contact c  copyir.com composite power supply PCB (J130-1) <-> developing assembly contact d  copyir.com composite power supply PCB (FT133) <-> transfer roller contact NO: Correct the connection  copyir.com 3  copyir.com Composite power supply PCB, DC controller PCB Try replacing the composite power supply PCB  copyir.com Is the problem corrected? YES: Yes  copyir.com NO: Replace the DC controller PCB  copyir.com
E100-0001    The BD signal is not detected 10 times or more within 10 msec in 5 msec after the generation of the laser drive signal    The wiring is faulty (short circuit, open circuit)  copyir.com The BD PCB is faulty  copyir.com The laser scanner unit is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com BD PCB Try replacing the BD PCB  copyir.com Is the problem corrected? YES: End  copyir.com 2  copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E100-0001    The BD signal is not detected 10 times or more within 10 msec in 5 msec after the generation of the laser drive signal    The wiring is faulty (short circuit, open circuit)  copyir.com The BD PCB is faulty  copyir.com The laser scanner unit is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com BD PCB Try replacing the BD PCB  copyir.com Is the problem corrected? YES: End  copyir.com 2  copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E100-0002    While the laser is ON, the BD signal cycle is outside a specific range 20 times or more continuously    The wiring is faulty (short circuit, open circuit)  copyir.com The BD PCB is faulty  copyir.com The laser scanner unit is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com BD PCB Try replacing the BD PCB  copyir.com Is the problem corrected? YES: End  copyir.com 2  copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E100-0003    While the laser is ON, the horizontal sync signal cycle is outside a specific range 20 times or more    The wiring is faulty (short circuit, open circuit)  copyir.com The BD PCB is faulty  copyir.com The laser scanner unit is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com BD PCB Try replacing the BD PCB  copyir.com Is the problem corrected? YES: End  copyir.com 2  copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E110-0000    The motor ready signal does not arrive within 15 sec after the laser scanner motor drive signal is generated    The wiring is faulty (short circuit, open circuit, disconnection)  copyir.com The laser scanner motor (M10) is faulty  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Are the connector (J312) on the DC controller PCB and the relay connector connected securely? NO: Connect the connectors securely  copyir.com 2  copyir.com Main power supply PCB During printing, does the voltage between J204-1 (+) and J204-2 (-) on the main power supply PCB change from 0 to about 24 V? NO: Replace the main power supply PCB  copyir.com 3  copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E202-0001    The scanner home position sensor does not go OFF when the scanner is moved forward by 40 mm    The scanner home position sensor (PS400) is faulty  copyir.com The scanner motor (M400) is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com State Does the scanner operate when the power is turned on? NO: See 4  copyir.com2  copyir.com9 The No  copyir.com 1 mirror base does not operate  copyir.com 2  copyir.com Scanner home position sensor (PS400), Reader controller PCB Move the No  copyir.com 1 mirror base by hand from home position  copyir.com Does the output of the scanner home position sensor change? (J405-2 on the reader controller PCB is 5 V (in HP) or 0V (away from HP)) NO: Replace the sensor  copyir.com YES: Replace the rear controller PCB  copyir.com
E202-0002    The scanner home position sensor does not go ON when the scanner is moved reverse 450 mm    The scanner home position sensor (PS400) is faulty  copyir.com The scanner motor (M400) is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com State Does the scanner operate when the power is turned on? NO: See 4  copyir.com2  copyir.com9 The No  copyir.com 1 mirror base does not operate  copyir.com 2  copyir.com Scanner home position sensor (PS400), Reader controller PCB Move the No  copyir.com 1 mirror base by hand from home position  copyir.com Does the output of the scanner home position sensor change? (J405-2 on the reader controller PCB is 5 V (in HP) or 0V (away from HP)) NO: Replace the sensor  copyir.com YES: Replace the rear controller PCB  copyir.com
E204-0001    While an original is being read, the image leading edge signal does not arrive from the ADF    The ADF controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com Caution When this code occurs, no code is indicated, but the keys are locked  copyir.com The code may be checked in service mode: COPIER>DISPLAY>ERR  copyir.com    1  copyir.com Read sensor (S2) Try replacing the read sensor of the ADF  copyir.com Is the problem corrected? YES: End  copyir.com 2  copyir.com ADF controller PCB, Reader controller PCB Try replacing the ADF controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the reader controller PCB  copyir.com
E220-0001    A fault is detected on the inverter PCB for the scanning lamp    The inverter PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Wiring Is the wiring from the scanning lamp to the reader controller PCB normal? NO: Connect the connector firmly, and correct or replace the wiring  copyir.com 2  copyir.com Inverter PCB, Reader controller PCB Try replacing the lamp inverter PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the reader controller PCB  copyir.com
E225-0000    A specific level cannot be attained for the signal during CCD gain correction at power-on    The scanning lamp is faulty  copyir.com The CCD PCB is faulty  copyir.com The rear controller PCB is faulty  copyir.com    1  copyir.com Scanning lamp (LAMP1) Is the lamp ON during the initial operation after the main power switch is turned on? NO: Replace the scanning lamp  copyir.com 2  copyir.com CCD unit, Reader controller PCB Try replacing the CCD unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the reader controller PCB  copyir.com
E225-0002    The edge gain correction level is different from the correction level for the preceding sheet by a specific level or more    The scanning lamp is faulty  copyir.com The CCD PCB is faulty  copyir.com The rear controller PCB is faulty  copyir.com    1  copyir.com Scanning lamp (LAMP1) Is the lamp ON during the initial operation after the main power switch is turned on? NO: Replace the scanning lamp  copyir.com 2  copyir.com CCD unit, Reader controller PCB Try replacing the CCD unit  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the reader controller PCB  copyir.com
E240-0000    A fault occurs in communication between the CPU of the main controller PCB and the CPU of the DC controller PCB    The main controller PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Wiring Is the wiring from the min controller PCB to the DC controller PCB normal? NO: Correct the wiring  copyir.com 2  copyir.com DC controller PCB, Main controlled PCB Try replacing the DC controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E243-0000    A fault occurs in the communication between the CPU of the control panel PCB and the CPU of the main controller PCB    The control panel CPU PCB is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Is the wiring from the main controller PCB to the DC controller PCB normal? NO: Correct the wiring  copyir.com 2  copyir.com Control panel CPU PCB, Main controller PCB Try replacing the control panel CPU PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E248-0001    A difference is discovered between the ID in EEPROM read when the main power switch is turned on and the ID in ROM upon comparison    The EEPROM (IC403) of the reader controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Execute the following in service mode: COPIER>FUNCTION>CLEAR>CON  copyir.com Is the proem corrected? YES: End  copyir.com After executing the service mode, be sure to enter the service mode data newly  copyir.com 2  copyir.com EE-PROM, Reader controller PCB Try replacing the EE-PROM  copyir.com Is the problem corrected? YES: End  copyir.com After replacement, be sure to enter the service mode data newly  copyir.com NO: Replace the rear controller PCB  copyir.com After replacement, be sure to enter the service mode date newly  copyir.com
E248-0002    The data read does not match the data written to EEPROM    The EEPROM (IC403) of the reader controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Execute the following in service mode: COPIER>FUNCTION>CLEAR>CON  copyir.com Is the proem corrected? YES: End  copyir.com After executing the service mode, be sure to enter the service mode data newly  copyir.com 2  copyir.com EE-PROM, Reader controller PCB Try replacing the EE-PROM  copyir.com Is the problem corrected? YES: End  copyir.com After replacement, be sure to enter the service mode data newly  copyir.com NO: Replace the rear controller PCB  copyir.com After replacement, be sure to enter the service mode date newly  copyir.com
E248-0003    A difference is discovered between the ID of EEPROM and the ID of ROM upon comparison while writing data    The EEPROM (IC403) of the reader controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Execute the following in service mode: COPIER>FUNCTION>CLEAR>CON  copyir.com Is the proem corrected? YES: End  copyir.com After executing the service mode, be sure to enter the service mode data newly  copyir.com 2  copyir.com EE-PROM, Reader controller PCB Try replacing the EE-PROM  copyir.com Is the problem corrected? YES: End  copyir.com After replacement, be sure to enter the service mode data newly  copyir.com NO: Replace the rear controller PCB  copyir.com After replacement, be sure to enter the service mode date newly  copyir.com
E261-0000    The intervals of zero-cross signals deviate from the tolerance range while the fixing heater is supplied with power    The wiring is faulty (short circuit, open circuit)  copyir.com The main power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connectors Are the connector J205 on the main power supply PCB and the connector J308B on the DC controller PCB securely connected? (zero-cross signal: J205-7 <-> J308B-1) NO: Connect the connectors securely  copyir.com 2  copyir.com Main power supply PCB, Main controller PCB Try replacing the main power supply PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E302-0001    During shading, the shading processing does not end on the reader controller PCB after 1 sec    The CCD PCB is faulty  copyir.com The wiring is faulty (short circuit, open circuit)  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Connector Are the connectors (J6001/J6002) on the CCD PCB and the connectors (J5002/J5003) on the reader controller PCB connected securely? NO: Connect the connectors securely  copyir.com 2  copyir.com CCD unit Try replacing the CCD unit  copyir.com Is the problem corrected? YES: End  copyir.com 3  copyir.com Reader controller PCB, Main controller PCB Try replacing the reader controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Check the wiring; if normal, replace the main controller PCB  copyir.com
E302-0002    During stream reading, the edge white addition processing does not end on the rear controller PCB after 10 sec    The CCD PCB is faulty  copyir.com The wiring is faulty (short circuit, open circuit)  copyir.com The reader controller PCB is faulty    1  copyir.com Connector Are the connectors (J6001/J6002) on the CCD PCB and the connectors (J5002/J5003) on the reader controller PCB connected securely? NO: Connect the connectors securely  copyir.com 2  copyir.com CCD unit Try replacing the CCD unit  copyir.com Is the problem corrected? YES: End  copyir.com 3  copyir.com Reader controller PCB, Main controller PCB Try replacing the reader controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Check the wiring; if normal, replace the main controller PCB  copyir.com
E315    Any of the following is true in the image processing by the main controller:
The image data has a fault The encoding/decoding operation for image data has a fault The image processing element of the main controller PCB has a fault    The image data is faulty  copyir.com The main controller PCB is faulty  copyir.com The HDD is faulty  copyir.com    If this error occurs during normal copying or printing, the job in question (image data) is cleared when the main power switch is turned off and then on again; i  copyir.come  copyir.com, the machine will be reset  copyir.com If this error occurs frequently, however, a fault on the main controller PCB is a possibility  copyir.com Further, if this error occurs in a specific image within the MAIL BOX, damage in data may be assumed; be sure to delete the image from the MAIL BOX  copyir.com
E420-0001    When the power switch of the host machine is turned on, the back-up data from the EEPROM cannot be read or the data that has been read has a fault    The EEPROM is faulty  copyir.com The ADF controller PCB is faulty  copyir.com
E421-0001    The back-up data cannot be written to the EEPROM, or the data that has been written has a fault    The EEPROM has a fault  copyir.com The ADF controller PCB has a fault  copyir.com
E422-0001    While the ADF is in standby, the communication with its host machine is disrupted for 5 sec or more; or, while the ADF is in operation, the communication with its host machine is disrupted for 0  copyir.com5 sec or more    The IPC communication is faulty  copyir.com The communication line has an open circuit  copyir.com The ADF controller PCB is faulty  copyir.com
E500-0000    The communication between the copier and the finisher is disrupted and is not corrected for 5 sec or less    The copier harness is faulty  copyir.com (disconnected connector, open circuit) The finisher controller PCB or the copier’s DC controller PCB is faulty  copyir.com
E501-0001    The communication between the finisher controller PCB and the puncher drive PCB is disrupted    The finisher controller PCB is faulty  copyir.com The puncher drive PCB is faulty  copyir.com
E505-0001    When the main power is turned on, the checksum of the finisher controller PCB has a fault    The EEPROM is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E505-0002    When the main power is turned on, the checksum of the puncher driverPCB has a fault    The EEPROM is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E510-0001    The feeding roller does not leave home position when the feed motor is driven for 2 sec    The feed motor (M1) is faulty  copyir.com The setting roller home position sensor is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E510-0002    The feeding roller does not return to home position when the feed motor is driven for 2 sec    The feed motor (M1) is faulty  copyir.com The setting roller home position sensor is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E514-0000    At the start of the motor CW operation, the stack handling motor (M2) may be driven for a specific number of rotations; however, the stack delivery lever home position sensor (S8) does not go ON    The stack handling motor (M2) is faulty  copyir.com The stack delivery lever home position sensor (S8) is faulty, the connector is disconnected, or an open circuit exits  copyir.com The stack handling motor (M2) relay harness is faulty  copyir.com The return roller is faulty
E514-0001    The delivery belt does not leave home position when the stack delivery motor is driven for 3 sec    The stack delivery motor (M3) is faulty  copyir.com The delivery belt home position motor (PI7) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E514-0002    The delivery belt does not return to home position when the stack delivery motor is driven for 3 sec    The stack delivery motor (M3) is faulty  copyir.com The delivery belt home position motor (PI7) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E530-0000    The alignment motor (M4) is driven for a specific number of rotations, but the aligning plate home position sensor (S7) does not go ON  copyir.com The alignment motor (M4) is driven for a specific number of rotations, but the aligning plate home position sensor (S7) does not go OFF    The rear alignment motor (M4) is faulty  copyir.com The rear aligning plate home position sensor (S7) is faulty  copyir.com The rear alignment motor relay harness is faulty  copyir.com The rear aligning plate is subjected to an excess load  copyir.com
E530-0001    The aligning plate (rear) does not leave home position when the alignment motor (rear) is driven for 3 sec    The alignment motor (rear; M5) is faulty  copyir.com The aligning plate home position sensor (rear; PI5) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E530-0002    The aligning plate (rear) does not return to home position when the alignment motor (rear) is driven for 3 sec    The alignment motor (rear; M5) is faulty  copyir.com The aligning plate home position sensor (rear; PI5) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E531-0000    The stapling home position sensor (S16) does not go off 0  copyir.com5 sec after the stapler motor is rotated CW  copyir.com The stapling home position sensor (S16) dos not go ON with 0  copyir.com5 sec after the stapler motor is rotated CW and, thereafter, the sensor does not go ON within 0  copyir.com5 sec after the motor is rotated in reverse    The stapler motor (M6) is faulty  copyir.com The stapling home position sensor (S16) is faulty  copyir.com The stapler harness is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E531-0001    The stapler does no leave home position when the stapler/folder motor is driven for 1  copyir.com5 sec    The stapler home position sensor (PI19) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI4) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E531-0002    The stapler does not return to home position when the stapler/folder motor is driven for 1  copyir.com5 sec    The stapler home position sensor (PI19) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI4) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E531-0003    The clock signal is disrupted for 1 sec or more while the stapler/folder motor is driven    The stapler home position sensor (PI19) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI4) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E532-0001    The stapler unit does not leave home position when the stapler slide motor is driven for 4  copyir.com5 sec    The slide home position sensor PI180 is faulty  copyir.com The stapler slide motor (M8) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E532-0002    The stapler unit does not return to home position when the stapler slide motor is driven for 4  copyir.com5 sec    The slide home position sensor PI180 is faulty  copyir.com The stapler slide motor (M8) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E537-0000    The aligning plate home position sensor (S6) does not go ON when the front alignment motor (M3) is driven for a specific number of rotations  copyir.com The aligning plate home position sensor (S6) does not go OFF when the front alignment motor (M3) is driven for a specific number of rotations    The front alignment motor (M3) is faulty  copyir.com The front aligning plate home position sensor (S6) is faulty  copyir.com The front alignment motor relay harness is faulty  copyir.com The front aligning plate is subjected to an excess load  copyir.com
E537-0001    The aligning plate (front) does not leave home position when the alignment motor (front) is driven for 3 sec    The alignment motor (front; M4) is faulty  copyir.com The aligning plate home position sensor (front; PI4) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E537-0002    The aligning plate (front) does not return to home potion when the alignment motor (front) is driven for 3 sec    The alignment motor (front; M4) is faulty  copyir.com The aligning plate home position sensor (front; PI4) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E540-0001    The paper surface sensor remains unchanged 10 sec after the tray ascent/ descent motor is driven    The paper surface sensor (PI9) is faulty  copyir.com The tray ascent/descent motor clock sensor (PI17) is faulty  copyir.com The tray upper limit sensor (PI15) is faulty  copyir.com The tray ascent/descent motor (M6) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E540-0002    The tray upper sensor goes ON while the tray is moving up  copyir.com    The paper surface sensor (PI9) is faulty  copyir.com The tray ascent/descent motor clock sensor (PI17) is faulty  copyir.com The tray upper limit sensor (PI15) is faulty  copyir.com The tray ascent/descent motor (M6) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E540-0003    The clock for the clock sensor is disrupted for 10 sec or more while the tray ascent/descent motor is driven    The paper surface sensor (PI9) is faulty  copyir.com The tray ascent/descent motor clock sensor (PI17) is faulty  copyir.com The tray upper limit sensor (PI15) is faulty  copyir.com The tray ascent/descent motor (M6) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E577-0000    The return roller does not reach home position when the delivery motor (Ml) has been driven as much as will move it to the return roller home position sensor (S3)    The delivery motor (M1) or the finisher controller PCB is faulty  copyir.com The return roller home position sensor (S3) is faulty, the harness connector is disconnected, or an open circuit exits  copyir.com The delivery motor relay harness is faulty  copyir.com The return roller is faulty  copyir.com
E577-0001    The paddle does not leave home position when the paddle motor is driven for 2 sec or more    The paddle home position sensor (PI2) is faulty  copyir.com The stack ascent/descent home point sensor Pixx0 is faulty  copyir.com The paddle motor (M2) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E577-0002    The paddle does not return to home position when the paddle motor is driven for 2 sec or more    The paddle home position sensor (PI2) is faulty  copyir.com The stack ascent/descent home point sensor Pixx0 is faulty  copyir.com The paddle motor (M2) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E577-0003    The stack ascent/descent guide does not leave home position when the paddle motor is driven for 2 sec or more    The paddle home position sensor (PI2) is faulty  copyir.com The stack ascent/descent home point sensor Pixx0 is faulty  copyir.com The paddle motor (M2) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E577-0004    The stack ascent/descent guide does not return to home position when the paddle motor is driven for 2 sec or more    The paddle home position sensor (PI2) is faulty  copyir.com The stack ascent/descent home point sensor Pixx0 is faulty  copyir.com The paddle motor (M2) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E580-0000    The delivery tray upper limit sensor (S13) goes ON while the delivery tray ascent/descent motor (M5) is in operation  copyir.com
The clock signal of the delivery tray ascent/descent motor clock sensor (S9) is not detected 15 times or more within 0  copyir.com8 sec while the delivery tray ascent/ descent motor (M5) is in operation  copyir.com
The delivery tray paper height sensor (S10) does not go ON 4 sec after the delivery tray ascent/descent motor (M5) starts to move up  copyir.com
The delivery tray paper height sensor (S10) does not go OFF 4 sec after the delivery tray ascent/descent motor (M5) starts to move down    The delivery tray ascent/descent motor (M5) is faulty  copyir.com The delivery tray paper height sensor (S10) is faulty, the harness is disconnected, or an open circuit exits  copyir.com The delivery tray ascent/descent motor lock sensor (S9) is faulty, the connector is disconnected, or an open circuit exits  copyir.com The delivery tray ascent/descent motor is subjected to an excess load  copyir.com The finisher controller PCB is faulty  copyir.com
E585-0000    At the start of the motor CCW operation, the stack handling motor (M2) may be driven for a specific number of rotations; however, the stack delivery lever home position sensor (S8) does not go ON    The stack handling motor (M2) is faulty  copyir.com The stack delivery lever home position sensor (S8) is faulty, the connector is disconnected, or an open circuit exits  copyir.com The stack handling motor (M2) relay harness is faulty  copyir.com The return roller is faulty  copyir.com
E590-0001    The puncher does not return to home position when the puncher motor is driven for 250 msec    The puncher home position sensor (PI1P) is faulty  copyir.com The puncher motor (M1P) is faulty  copyir.com The puncher motor clock sensor (PI3P) is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E590-0002    The clock from the puncher motor clock sensor is disrupted for 60 msec or more when the puncher motor is driven    The puncher home position sensor (PI1P) is faulty  copyir.com The puncher motor (M1P) is faulty  copyir.com The puncher motor clock sensor (PI3P) is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E592-0001   copyir.com  copyir.com  copyir.com E592-0005    In the course of sensor output automatic adjustment, the light-receiving voltage is 2  copyir.com5 V or less even when the light-emitting voltage is set to 4  copyir.com4 V  copyir.com In the course of output automatic adjustment, the light-receiving voltage is 2  copyir.com5 V or more even when the light-emitting voltage is set to 0 V  copyir.com In the course of sensor output automatic adjustment, the light-emitting voltage is set to 4  copyir.com4 V or more
Horizontal registration sensor    The horizontal registration sensor is faulty  copyir.com The puncher waste sensor is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E592-0006    In the course of sensor output automatic adjustment, the light-receiving voltage is 2  copyir.com5 V or less even when the light-emitting voltage is set to 4  copyir.com4 V  copyir.com In the course of output automatic adjustment, the light-receiving voltage is 2  copyir.com5 V or more even when the light-emitting voltage is set to 0 V  copyir.com In the course of sensor output automatic adjustment, the light-emitting voltage is set to 4  copyir.com4 V or more
Puncher waste full sensor    The horizontal registration sensor is faulty  copyir.com The puncher waste sensor is faulty  copyir.com The puncher driver PCB is faulty  copyir.com
E593-0001    The puncher not leave home position when the puncher shift motor is driven for 1 sec    The horizontal registration home position sensor (PI2P) is faulty  copyir.com The puncher shift motor (M2P) is faulty  copyir.com The puncher drive PCB is faulty
E593-0002    The puncher does not return to home position when the puncher shift motor is driven for 1 sec    The horizontal registration home position sensor (PI2P) is faulty  copyir.com The puncher shift motor (M2P) is faulty  copyir.com The puncher drive PCB is faulty
E5F1-0001    The folding roller does not leave home position when the stapler/folder motor is driven for 1  copyir.com5 sec    The folding roller home position sensor (PI12) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI14) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E5F1-0002    The folding roller does to return to home position when the stapler/folder motor is driven for 3  copyir.com5 sec or more    The folding roller home position sensor (PI12) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI14) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E5F1-0003    The clock is disrupted for 1 sec or more while the stapler/folder motor is driven    The folding roller home position sensor (PI12) is faulty  copyir.com The stapler/folder motor (M7) is faulty  copyir.com The stapler/folder clock sensor (PI14) is faulty  copyir.com The finisher controller PCB is faulty  copyir.com
E601-0000    When an image is transferred between the main controller PCB and the HDD, the main controller PCB detects a fault in control information    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The DC controller PCB is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and the cable between the connector J1017 on the main controller PCB and the connector J1551 on the HDD normal? YES: End  copyir.com NO: Correct the connection/cable  copyir.com 2  copyir.com HDD, Main controller PCB Try replacing the HDD, and download the system software  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E601-0001    When an image is transferred between the main controller PCB and the DC controller PCB, the DC controller PCB detects a fault in the control information    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The DC controller PCB is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and cable between the connector J122 on the DC controller PCB and the connector J1015 on the main controller PCB normal? NO: Correct the connection/cable  copyir.com 2  copyir.com DC controller PCB, Main controller PCB Try replacing the DC controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E602-0001    A mounting fault of the HDD is detected when the HDD is started up from the BOOT ROM    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and the cable between connector J1025 of the main controller PCB and the connector J2005 of the HDD normal? NO: Correct the connector/cable  copyir.com 2  copyir.com System software Try re-installing the system software  copyir.com Is the problem corrected? YES: End  copyir.com 3  copyir.com HDD, Main controller PCB Try replacing the HDD, and download the system software  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E602-0002    A data read fault of the HDD is detected when the HDD is started up from the BOOT ROM    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and the cable between connector J1025 of the main controller PCB and the connector J2005 of the HDD normal? NO: Correct the connector/cable  copyir.com 2  copyir.com System software Try re-installing the system software  copyir.com Is the problem corrected? YES: End  copyir.com 3  copyir.com HDD, Main controller PCB Try replacing the HDD, and download the system software  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E604-0000    A fault is detected in the image memory    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The main controller PCB is faulty  copyir.com
E605-0001    A fault is detected in the battery for the image memory    The wiring is faulty (short circuit, open circuit)  copyir.com The HDD is faulty  copyir.com The main controller PCB is faulty  copyir.com
E606-0001    A mounting fault of the HDD is detected when the HDD is started up from the BOOT ROM    The HDD is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and cable normal between the connector J1025 on the main controller PCB and the connector J2005 of the HDD? NO: Correct the connection and the cable  copyir.com 2  copyir.com System software Try re-installing the system software  copyir.com Is the problem corrected? YES: End  copyir.com 3  copyir.com HDD, Main controller PCB Try replacing the HDD and downloading the system software  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E674-0000    A faulty occurs in the communication between the fax PCB and the main controller PCB    The wiring is faulty (short circuit, open circuit)  copyir.com The fax PCB is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Wiring Are the connection and the cable between the connector J 1005 on the main controller PCB and the connector J31 on the FAX PCB normal? NO: Correct the connection and the cable  copyir.com 2  copyir.com FAX PCB, Main controller PCB Try replacing the FAX PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E677-0001    A fault occurs it the combination between any of the printer boards (accessories) and the main controller PCB    Any of the printer boards (accessories) is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connector Is the printer board (accessory) connected correctly? NO: Correct the connection  copyir.com 2  copyir.com Printer board, Main controller PCB Try replacing the printer board  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E710-0001    When the main power is turned on, the communication IC (IPC) on the reader controller PCB cannot be initialized    The DC controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com The machine controller PCB is faulty  copyir.com    Turn off and then on the main power switch  copyir.com Is the problem corrected? YES: End  copyir.com NO: If E7100001, replace the reader controller PCB  copyir.com If E710-002, replace the DC controller PCB  copyir.com If E71-0003, replace the main controller PCB  copyir.com
E710-0002    When the main power is turned on, the communication IC (IPC) on the DC controller PCB cannot be initialized    The DC controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com The machine controller PCB is faulty  copyir.com    Turn off and then on the main power switch  copyir.com Is the problem corrected? YES: End  copyir.com NO: If E7100001, replace the reader controller PCB  copyir.com If E710-002, replace the DC controller PCB  copyir.com If E71-0003, replace the main controller PCB  copyir.com
E710-0003    When the main power is trend on, the communication IC (IPC) on the main controller PCB cannot be initialized    The DC controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com The machine controller PCB is faulty  copyir.com    Turn off and then on the main power switch  copyir.com Is the problem corrected? YES: End  copyir.com NO: If E7100001, replace the reader controller PCB  copyir.com If E710-002, replace the DC controller PCB  copyir.com If E71-0003, replace the main controller PCB  copyir.com
E711-0001    Data is written to the error register of the communication IC (IPC) on the reader controller PCB four times or more within 1  copyir.com5 sec    The connector has poor connection  copyir.com The ADF controller PCB is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The DA unit PCB is faulty  copyir.com The card reader PCB is faulty  copyir.com    Connector, ADF controller PCB Is the interface cable between the ADF controller PCB an the reader controller PCB normal? NO: Correct the cable  copyir.com YES: Replace the ADF controller PCB  copyir.com
E711-0002    Data is written to the error register of the communication IC (IPC) on the DC controller PCB four times or more within 2 sec    The connector has poor connection  copyir.com The ADF controller PCB is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The DA unit PCB is faulty  copyir.com The card reader PCB is faulty  copyir.com    connector, Finisher controller PCB Is the interface cable between the finisher controller PCB and the DC controller PCB normal? NO: Correct the cable  copyir.com YES: Replace the finisher controller PCB  copyir.com
E711-0003    Data is written to the error register of the communication IC (IPC) on the main controller PCB four times or more within 2 sec    The connector has poor connection  copyir.com The ADF controller PCB is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The DA unit PCB is faulty  copyir.com The card reader PCB is faulty  copyir.com    Connector, DA unit PCB Is the interface cable between the DA unit PCB and the main controller PCB normal? NO: Correct the cable  copyir.com YES: Replace the NE controller PCB  copyir.com
E712-0001    The communication is not resumed 3 sec or more after data has been written to the error register of the communication IC (IPC) on the ADF controller PCB    The connect has poor connection  copyir.com The main power supply PCB is faulty  copyir.com The ADF controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Connector Is the interface able between the ADF controller PCB and the reader controller PCB normal? NO: Correct the cable  copyir.com 2  copyir.com Main power supply PCB While the ADF is in operation, does the voltage between J203-2 (+) and J203-1 (-) on the main power supply PCB change from 0 to about 24 V? NO: Replace the main power supply PCB  copyir.com 3  copyir.com ADF controller PCB, Reader controller PCB Try replacing the ADF controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the rear controller PCB  copyir.com
E712-0002    The transmission bit is not enabled 10 sec or more in the sync register of the communication IC (IPC) on e reader controller PCB    The connect has poor connection  copyir.com The main power supply PCB is faulty  copyir.com The ADF controller PCB is faulty  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Connector Is the interface able between the ADF controller PCB and the reader controller PCB normal? NO: Correct the cable  copyir.com 2  copyir.com Main power supply PCB While the ADF is in operation, does the voltage between J203-2 (+) and J203-1 (-) on the main power supply PCB change from 0 to about 24 V? NO: Replace the main power supply PCB  copyir.com 3  copyir.com ADF controller PCB, Reader controller PCB Try replacing the ADF controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the rear controller PCB  copyir.com
E713-0000    The communication with the finisher is not resumed 3 sec or more after it is disrupted    The connector has poor connection  copyir.com The option power supply PCB is faulty  copyir.com The finisher controller PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Is the wiring between the finisher controller PCB and the options power supply PCB and between the options power supply PCB and the DC controller PCB normal? NO: Correct the wiring  copyir.com 2  copyir.com Options power supply PCB Is the voltage between HJ701-6 (+) and J701-7 (-) on the options power supply PCB about 24 V? NO: Replace the options power supply PCB  copyir.com 3  copyir.com Finisher controller PCB, DC controller PCB Try replacing the finisher controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E716-0000    The ID signal is not detected within a specific period of time after the presence of a pedestal is detected    The connector has poor connection  copyir.com The main power supply PCB is faulty  copyir.com The pedestal controller PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Is the wiring between the pedestal controller PCB and the main power supply PCB and between the main power supply PCB and the DC controller PCB normal? NO: Correct the wiring  copyir.com 2  copyir.com Main power supply PCB Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply PCB about 24 V? NO: Replace the main power supply PCB  copyir.com 3  copyir.com Pedestal controller PCB, DC controller PCB Try replacing the pedestal controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller  copyir.com
E717-0001    The communication with the DA unit is not resumed 3 sec or more after it is disrupted  copyir.com    The wiring is faulty (short circuit, open circuit)  copyir.com The DA unit PCB is faulty  copyir.com The main controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR  copyir.com    1  copyir.com Connector Is the connection between the DA unit PCB and the main controller PCB secure? NO: Correct the connection  copyir.com 2  copyir.com DA unit PCB, main controller PCB Try replacing the DA unit PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E719-0000    Erroneous communication with card reader (serial communication)
E719-0001    The communication between the Card Reader-C1 or the coin vendor and the main controller PCB is disrupted    The wiring is faulty (short circuit, open circuit)  copyir.com The Card Reader-C1 is faulty  copyir.com The coin vendor is faulty  copyir.com The main controller PCB is faulty  copyir.com Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR  copyir.com    1  copyir.com Connector Is the Cad Reader-C1 or the coin vendor connected securely? NO: Connect it securely  copyir.com 2  copyir.com Coin vendor, Main controller PCB Try replacing the Card Reader-C1 or the coin vendor  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E719-0002    Erroneous communication with coin vender (serial communication)
E732-0001    A fault is detected by the main controller PCB in the communication between reader controller PCB and the main controller PCB    The connector has poor connection  copyir.com The reader controller PCB is faulty  copyir.com    1  copyir.com Connector, Reader controller PCB Is the connection between the connector J1014 on the main controller PCB and the connector J409 on the reader controller PCB normal? NO: Correct the connection  copyir.com YES: Replace the reader controller PCB  copyir.com
E733-0001    A fault is detected by the main controller PCB in the communication between the DC controller PCB and the main controller PCB    The connector has poor connection  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector, DC controller PCB Is the connection between the connector J1015 on the main controller PCB and the conductor J316 on the DC controlled PCB normal? NO: Correct the connection  copyir.com YES: Replace the DC controller PCB  copyir.com
E737-0000    During self diagnosis at power-on, the DRAM check finds a fault in the main controller PCB    The connection of the IC socket is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connection Is the DRAM fitted to the socket securely? NO: Fit the DRAM securely  copyir.com 2  copyir.com DRAM, Main controller PCB Try replacing the DRAM  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E740-0001    At power-on, the LAN card has a fault    The LAN card is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connector Is the connection between the LAN card and the main controller PCB normal? NO: Correct the connection  copyir.com 2  copyir.com LAN card, Main controller PCB Try replacing the LAN card  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E740-0002    The MAC address has a fault    The LAN card is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connector Is the connection between the LAN card and the main controller PCB normal? NO: Correct the connection  copyir.com 2  copyir.com LAN card, Main controller PCB Try replacing the LAN card  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E740-0003    The LAN card cannot be read    The LAN card is faulty  copyir.com The main controller PCB is faulty  copyir.com    1  copyir.com Connector Is the connection between the LAN card and the main controller PCB normal? NO: Correct the connection  copyir.com 2  copyir.com LAN card, Main controller PCB Try replacing the LAN card  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E741-0000    The PCI bus has a fault    The PCI bus has poor connection  copyir.com The main controller PCB is faulty  copyir.com    Each PCI slot may be disabled in service mode to prevent the error: BOARD>PCI1-OFF through PCI3-OFF  copyir.com 1  copyir.com Board Is the connection between the relay board and the main controller PCB normal? NO: Correct the connection  copyir.com 2  copyir.com Relay board, Main Controller PCB Try replacing the relay board  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the main controller PCB  copyir.com
E743-0000    The reader controller PCB detects a fault in the communication between the main controller PCB and the reader controller PCB    The connector has poor connection  copyir.com The main controller PCB has a fault  copyir.com    1  copyir.com Connector, Main controller PCB Is the connection between the connector J1014 on the main controller PCB and the connector J409 on the reader controller PCB normal? NO: Correct the connection  copyir.com YES: Replace the main controller PCB  copyir.com
E744-0000    The BootROM on the main controller PCB and the system software are for different models or are of different types    The BootROM is not mounted correctly, or a fault occurred during downloading or when downloading the system software  copyir.com    Downloading (system software) Check the types of the BootROM and the system software, and download system software of the correct type  copyir.com
E803-0000    The 24V output from the composite main power supply PCB is absent for 1 sec or more    The wiring is faulty (short circuit, open circuit)  copyir.com The composite power supply PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connectors Are the connectors J204 on the main power supply PCB and the connector J300 on the DC controller PCB connected securely? NO: Connect the connectors securely  copyir.com 2  copyir.com Main power supply PCB Is 24 V supplied by the main power supply PCB (J204) to the DC controller PCB (J300)? (J204-5 <-> J300-5: OVU3, J204-6 <-> J300-6: OVU3, J204-7 <-> J300-7: 24VU3, J204-8 <-> J300-8: 24VU3) NO: Replace the main power supply PCB  copyir.com YES: Replace the DC controller PCB  copyir.com
E805-0001    The clock signal is absent for 5 sec or more after the fan drive signal has been generated  copyir.com The detail codes of the fans in question are as follows:
developing fan (FM1)    The fan wiring is faulty (short circuit, open circuit)  copyir.com The fan is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter  copyir.com 2  copyir.com Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection  copyir.com 3  copyir.com Fan, DC controller PCB Try replacing the fan  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E805-0002    The clock signal is absent for 5 sec or more after the fan drive signal has been generated  copyir.com The detail codes of the fans in question are as follows:
fixing fan (FM2)    The fan wiring is faulty (short circuit, open circuit)  copyir.com The fan is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter  copyir.com 2  copyir.com Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection  copyir.com 3  copyir.com Fan, DC controller PCB Try replacing the fan  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E805-0003    The clock signal is absent for 5 sec or more after the fan drive signal has been generated  copyir.com The detail codes of the fans in question are as follows:
curl reducing fan (FM4)    The fan wiring is faulty (short circuit, open circuit)  copyir.com The fan is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter  copyir.com 2  copyir.com Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection  copyir.com 3  copyir.com Fan, DC controller PCB Try replacing the fan  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E805-0004    The clock signal is absent for 5 sec or more after the fan drive signal has been generated  copyir.com The detail codes of the fans in question are as follows:
curl reducing fan (FM5)    The fan wiring is faulty (short circuit, open circuit)  copyir.com The fan is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter  copyir.com 2  copyir.com Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection  copyir.com 3  copyir.com Fan, DC controller PCB Try replacing the fan  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E805-0005    The clock signal is absent for 5 sec or more after the fan drive signal has been generated  copyir.com The detail codes of the fans in question are as follows:
electrical unit fan (FM3)    The fan wiring is faulty (short circuit, open circuit)  copyir.com The fan is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter  copyir.com 2  copyir.com Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection  copyir.com 3  copyir.com Fan, DC controller PCB Try replacing the fan  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com
E901-0000    The motor ready signal does not arrive within 1  copyir.com3 sec after the pedestal main motor drive signal is generated    The connector has poor connector  copyir.com The pedestal main motor is faulty  copyir.com The main power supply PCB is faulty  copyir.com The pedestal controller PCB is faulty  copyir.com The DC controller PCB is faulty  copyir.com    1  copyir.com Connector Is the wiring between the pedestal controller PCB and the main power supply PCB and between the main power supply PCB and the DC controller PCB normal? NO: Correct the wiring  copyir.com 2  copyir.com Main power supply PCB Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply PCB about 24 V? NO: Replace the main power supply PCB  copyir.com 3  copyir.com Pedestal main motor Try replacing the pedestal main motor  copyir.com Is the problem corrected? YES: End  copyir.com 4  copyir.com Pedestal controller PCB, DC controller PCB Try replacing the pedestal controller PCB  copyir.com Is the problem corrected? YES: End  copyir.com NO: Replace the DC controller PCB  copyir.com