کانون Canon iRC3170i
E000-0001 Insufficient temperature rise of the fixing unit at power-on
Delay in temperature rise after poweron The non-contact thermistor fails to reach 50 deg C within 180sec after power-on copyir.ocm Check on connection of the thermistor/thermo switch, Check on a break in the heater, Replace the cover switch, Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0001 Abnormality of the fixing unit
High temperature of the end thermistor is detected copyir.ocm (Hardware) The hardware detects abnormal high temperature of the end thermistor (230 deg C or higher) for 400msec continuously copyir.ocm Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
E001-0002 Abnormality of the fixing unit
High temperature of the non-contact thermistor (Software) Abnormal high temperature (250 deg C or higher) of the non-contact thermistor is detected for 500ms continuously copyir.ocm Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
E001-0003 Abnormality of the fixing unit
High temperature of the end thermistor (Software) Abnormal high temperature (220 deg C or more) of the end thermistor is detected for 500ms continuously copyir.ocm Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
E001-0004 Abnormality of the fixing unit
Large difference in temperature between end and center Difference in temperature (80 deg C or more) between the non-contact thermistor and the end thermistor is detected for 500msec continuously Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
E001-0005 Abnormality of the fixing unit
Foreign matter in the non-contact thermistor At the end of initial multiple rotations, difference in temperature (20 deg C or more) between the non-contact thermistor and the end thermistor is detected for 200msec continuously copyir.ocm Check on remaining paper in the fixing unit, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0006 Abnormality of the fixing unit
A break in the non-contact thermistor film The status that A/D of the non-contact thermistor film is FFh continues for 500msec copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0007 Abnormality of the fixing unit
A short circuit in the non-contact thermistor film The status that A/D of the non-contact thermistor film is 30h or less continues for 500msec copyir.ocm Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0008 Abnormality of the fixing unit
A break in the non-contact thermistor case The status that A/D of the non-contact thermistor case is FFh continues for 500msec copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0009 Abnormality of the fixing unit
A short circuit in the non-contact thermistor case The status that film A/D-case A/D of the non-contact thermistor is 0C or more continues for 700msec copyir.ocm Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0010 Abnormality of the fixing unit
A break in the end thermistor The status that A/D of the contact thermistor case is FFh continues for 500msec Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E001-0011 Abnormality of the fixing unit
A short circuit in the end thermistor The status that A/D of the contact thermistor case is 39h or less continues for 500msec copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0002 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 70 deg C within 180 sec after reaching 50 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0003 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 100 deg C within 180 sec after reaching 70 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0004 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 120 deg C within 180 sec after reaching 100 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0005 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 140 deg C within 180 sec after reaching 120 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0006 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 160 deg C within 180 sec after reaching 140 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0007 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 180 deg C within 180 sec after reaching 160 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0008 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 180 sec after reaching 180 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0101 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 120 deg C within 300 sec after power-on copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E002-0102 Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 300 sec after reaching 120 deg C copyir.ocm Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E003-0001 Low temperature of the fixing unit after standby
Abnormal low temperature (130 deg C or lower) of the non-contact thermistor is detected for 3 copyir.ocm5 sec continuously after standby copyir.ocm Check on connection of the sub thermistor/thermo switch, Replace the fixing unit, Check on a break in the heater, Replace the cover switch, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E004-0001 Error of the protection circuit in the fixing unit
The hardware detects triac short abnormality (1 sec or more) for 400msec continuously while the heater is OFF copyir.ocm Turn OFF and back ON the main power, Check on connection of the thermo switch, Replace the main power supply PCB, Replace the DC controller PCB
E006-0000 Connection error of the fixing unit
The hardware detects non-attachment of the fixing unit for 400msec continuously copyir.ocm A break in the fixing unit presence/ absence signal (FUSER_CNCTX_N) / Disconnection of the connector (The connectors are placed as shown below) DC controller PCB : J316 Fixing unit : J2007, J2008 Relay connector (between DC controller and fixing unit) : J2006 (7 pins) Check on connection of the fixing unit cable, Replace the relay cable, Replace the fixing unit, Replace the DC controller PCB
E008-0001 Life expectancy of the fixing roller
The fixing roller life expectancy counter reaches its upper limit (120,000) copyir.ocm Replace the fixing roller or fixing unit After replacement, enter “0” to the service mode COPIER>COUNTER >MISC>FX-UP-RL
E010-0001 Main motor error
Lock of the motor fails to be detected 2 sec or more after the motor starts to operate copyir.ocm Check on connection of the connector, Replace the motor
E010-0002 Main motor error
After rotation of the motor becomes stable, the motor lock fails (i copyir.ocme copyir.ocm, the motor becomes unstable) for 500msec or more copyir.ocm Check on connection of the connector, Replace the motor
E012-0001 Drum motor error
Lock of the motor fails to be detected 2 sec or more after the motor starts to operate copyir.ocm Check on connection of the connector, Replace the motor
E012-0002 Drum motor error
After rotation of the motor becomes stable, the motor lock fails (i copyir.ocme copyir.ocm, the motor becomes unstable) for 500msec or more copyir.ocm Check on connection of the connector, Replace the motor
E013-0000 ITB waste toner full error
Jobs for 500 images (on a small-size paper basis) have been executed after the ITB waste toner full sensor is turned ON copyir.ocm Replace the waste toner container
E014-0001 Fixing motor error
Lock of the motor fails to be detected 2sec or more after the motor starts to operate copyir.ocm Check on connection of the connector, Replace the motor, Replace the fixing roller
E014-0002 Fixing motor error
After rotation of the motor becomes stable, the motor lock fails (i copyir.ocme copyir.ocm, the motor becomes unstable) for 500msec or more copyir.ocm Check on connection of the connector, Replace the motor, Replace the fixing roller
E020-XX10 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In INIT control of the initial setting, SGNL is less than 62 copyir.ocm Clean the ATR sensor window, Check on attachment of the developing unit, Check on a break in the ATR sensor, Replace the ATR sensor
E020-XX11 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In INIT control of the initial setting, REF is less than 62 copyir.ocm Check on a break in the ATR sensor, Replace the ATR sensor
E020-XX12 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In INIT control of the initial setting, SGNL is 960 or more copyir.ocm Check on a break in the ATR sensor, Check on operation of the shutter, Replace the ATR sensor
E020-XX13 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In INIT control of the initial setting, REF is 960 or more copyir.ocm Check on a break in the ATR sensor, Replace the ATR sensor
E020-XX50 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
When density data is computed using SGNL value and REF value in ATR control, REF becomes 0 due to backup data corruption copyir.ocm Clean the ATR sensor window, Check on attachment of the developing unit, Check on a break in the ATR sensor, Replace the ATR sensor, Replace the DC controller PCB
E020-XX51 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
When density data is computed using SGNL value and REF value in ATR control, the sensitivity coefficient becomes 0 due to backup data corruption copyir.ocm Replace the DC controller PCB
E020-XX81 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
P-SENS-P is less than 255 when a base (drum face) of patch detection is read out copyir.ocm Clean the patch image reading sensor window
E020-XX90 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
A computation result of patch reading in patch detection is less than 16 copyir.ocm Check on attachment of the developing unit, Replace the patch image reading sensor, Replace the developing unit
E020-XX91 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
A computation result of patch reading in patch detection is 1008 or more copyir.ocm Check on toner leak from toner buffer in the developing unit, Replace the patch image reading sensor
E020-XX92 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
A computation result of patch reading in patch detection is less than 42 for Y/M/ C and less than 73 for Bk 3 times in succession copyir.ocm Check on attachment of the developing unit, Replace the patch image reading sensor, Replace the developing unit
E020-XX93 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
A computation result of patch reading in patch detection is 522 or more for Y/M/ C and 543 or more for Bk 3 times in succession copyir.ocm Check on toner leak from toner buffer in the developing unit, Replace the patch image reading sensor
E020-XXA0 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, SGNL is less than 62 copyir.ocm Clean the ATR sensor window, Check on attachment of the developing unit, Check on a break in the ATR sensor, Replace the ATR sensor
E020-XXA1 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, REF is less than 62 copyir.ocm Check on a break in the ATR sensor, Replace the ATR sensor
E020-XXA2 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, SGNL is 960 or more copyir.ocm Check on a break in the ATR sensor, Check on operation of the shutter, Replace the ATR sensor
E020-XXA2 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, SGNL is 960 or more copyir.ocm Check on a break in the ATR sensor, Check on operation of the shutter, Replace the ATR sensor
E020-XXA3 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, REF is 960 or more copyir.ocm Check on a break in the ATR sensor, Replace the ATR sensor
E020-XXA8 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, the detected T/D ratio is upper than its upper limit (13%) 3 times in succession copyir.ocm Check on toner leak from toner buffer in the developing unit, Replace the ATR sensor
E020-XXA9 Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
In ATR control, the detected T/D ratio is lower than its lower limit (3%) 3 times in succession copyir.ocm Check on attachment of the developing unit, Replace the ATR sensor
E021-0001 Developing rotary error
HP of the developing rotary fails to be detected copyir.ocm Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
E021-0002 Developing rotary error
Flag detection timing while the developing rotary rotates is too fast or too late copyir.ocm Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
E021-0003 Developing rotary error
The sensor fails to detect the flag when the developing rotary stops at the developing position copyir.ocm Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
E026-XX01 Toner empty error XX=01:Y XX=02:M XX=03:C XX=04:K
After toner runs out, toner density fails to go back to normal even if toner replacement and toner recovery have been performed 5 times or more in succession copyir.ocm Replace the toner container, Check on a position of the developing shutter
E032-0001 The counter of the NE controller fails to operate copyir.ocm
A break in the count pulse signal is detected copyir.ocm Check on a break in the cable
E045-0001 OHP sensor error
The sampling data measured during initial multiple rotations is lower than the specific level copyir.ocm Replace the OHP sensor
E067-0100 High voltage-related error
The measured current of the primary transfer ATVC is abnormal twice in succession copyir.ocm Check on the primary transfer roller spring, Clean the position where the primary transfer roller contacts, Replace the primary transfer roller, Replace the drum unit Check a value of COPIER> DISPLAY> MISC> DRM-LIFE, and replace the drum unit if the value is near 100 because the drum may have reached its life expectancy copyir.ocm
E067-0110 High voltage-related error
The measured voltage of the primary transfer ATVC is abnormal twice in succession copyir.ocm Turn OFF and back ON the main power
E070-0001 ITB HP detection error
HP of the ITB fails to be detected even after the specific period of time copyir.ocm Abnormality of the HP sensor, Deviation of the belt from its position to either edge, or soiling of the seal Clean the HP detection seal, Clean/Replace the HP sensor
E070-0002 ITB HP detection error
The next HP fails to be detected within the specific period of time after the HP of the ITB is detected copyir.ocm Clean the ITB back side and the drive roller
E070-0003 ITB HP detection error
The next HP is detected earlier than the specific period of time after the HP of the ITB is detected copyir.ocm The ITB is torn due to scratches, and the sensor detects the tear as a HP by mistake copyir.ocm Clean the HP detection seal, Clean/Replace the HP sensor
E100-0001 BD error
Speed lock of the BD speed control fails to be executed 5 sec after the laser scanner motor starts to operate copyir.ocm Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
E100-0002 BD error
The speed lock of the BD speed control fails while rotation of the laser scanner motor is stable copyir.ocm Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
E100-0003 BD error
The phase lock of the BD phase control fails while rotation of the laser scanner motor is stable copyir.ocm Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
E100-0004 BD error
Phase lock of the BD phase control fails to be executed 6 sec after the laser scanner motor starts to operate copyir.ocm Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
E110-0001 Operation error of the laser scanner motor
Speed lock of the FG speed control fails to be executed 5 sec after the laser scanner motor starts to operate copyir.ocm Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
E202-0001 CIS unit HP detection error
The HP sensor fails to be ON after the CIS unit moves backward for a specific distance or more copyir.ocm Disconnect and then connect the connector, Replace the scanner HP sensor, Replace the scanner motor, Replace the reader controller PCB
E202-0002 CIS unit HP detection error
The HP sensor fails to be OFF after the CIS unit moves forward for a specific distance or more copyir.ocm Disconnect and then connect the connector, Replace the scanner HP sensor, Replace the scanner motor, Replace the reader controller PCB
E225-0001 CIS light quantity error
Normal light-up of the lamp fails to be confirmed at the time of power-on and shading correction when a job starts copyir.ocm Disconnect and then connect the connector, Replace the document lamp (xenon tube), Replace the CIS, Replace the inverter PCB, Replace the reader controller PCB
E227-0001 Power supply error in the reader unit
2 4V port is off at power-on copyir.ocm Disconnect and connect the power supply connector, Replace the power supply
E227-0002 Power supply error in the reader unit
24V port is off when a job starts copyir.ocm Disconnect and connect the power supply connector, Replace the power supply
E227-0003 Power supply error in the reader unit
24V port is off when a job terminates copyir.ocm Disconnect and connect the power supply connector, Replace the power supply
E227-0004 Power supply error in the reader unit
24V port is off during a drive under load copyir.ocm Disconnect and connect the power supply connector, Replace the power supply
E243-0000 Control panel unit error
Communication between the main controller and the control panel unit is abnormal copyir.ocm Check on connection between the main controller PCB and the control panel unit
E248-0000 Backup memory error
Check error of the SRAM PCB (at start up) Check on connection of the SRAM PCB, Replace the SRAM PCB
E248-0001 Backup memory error
Reader controller EEPROM error at power-on Replace the reader controller PCB
E248-0002 Backup memory error
Reader controller EEPROM writing error Replace the reader controller PCB
E248-0003 Backup memory error
Reader controller EEPROM reading error after check error writing Replace the reader controller PCB
E315-0008 Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty copyir.ocm Timeout error during encoding (No response after 30sec passed) Check on connection of the image conversion board, Replace the image conversion board
E315-000e Abnormality of image data
Data is corrupt (Abnormality of memory/HDD) Soft decode error Replace the image memory (SDRAM) , Replace the HDD
E315-0010 Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty copyir.ocm Timeout error during decoding Check on connection of the image conversion board, Replace the image conversion board
E315-0025 Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty copyir.ocm Image data transfer error during rotation processing copyir.ocm Check on connection of the image conversion board, Replace the image conversion board
E315-0028 Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty copyir.ocm Timeout error during rotation processing Check on connection of the image conversion board, Replace the image conversion board
E315-0034 Abnormality of image data
ASIC (for scaling processing) on the image conversion PCB is faulty copyir.ocm Image data transfer error during scaling processing Check on connection of the image conversion board, Replace the image conversion board
E315-0036 Abnormality of image data
ASIC (for scaling processing) on the image conversion PCB is faulty copyir.ocm Timeout error during scaling processing Check on connection of the image conversion board, Replace the image conversion board
E351-0000 Main controller PCB error
Communication error of the main controller PCB occurs at start-up copyir.ocm Check on connection between the main controller PCB and the main controller PCB (sub) , Replace the main controller PCB, Replace the main controller PCB (sub)
E400-0001 Feeder communication error
Checksum error Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
E400-0002 Feeder communication error
Reception status error Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
E400-0003 Feeder communication error
Reception interrupt error Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
E490-0001 Model error
Feeder for other model is detected copyir.ocm Connect an appropriate feeder
E500-0001 Finisher communication error
Communication error is detected between the main body and the finisher for specific times and specific period of time copyir.ocm Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB
E503-0002 Finisher internal communication error Finisher-P1
Communication error between the finisher and the saddle unit Check on connection between the saddle stitcher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the saddle stitcher controller PCB
E503-0003 Finisher internal communication error Finisher-P1
Communication error between the finisher and the puncher unit Check on connection between the puncher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the puncher controller PCB
E505-0001 Finisher backup memory error
Data stored in the backup memory is abnormal copyir.ocm Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB
E505-0002 Finisher backup memory error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
Abnormality of puncher unit EEPROM data Check on connection between the puncher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the puncher controller PCB
E514-0001 Stack delivery error Finisher-P1
The HP sensor fails to be ON within 1500ms after the return belt starts to move to its HP copyir.ocm Check on a drive of the stack retaining roller, Replace the return belt U-turn HP sensor (SR5) , Replace the stack delivery motor (M2)
E514-0001 End assist motor error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the end assist motor rotates for a specific period of time copyir.ocm Replace the end assist HP sensor (PI39) , Replace the end assist motor (M39)
E514-0002 Stack delivery error Finisher-P1
The HP sensor fails to be OFF within 1500ms after the return belt starts to move to the belt contact position copyir.ocm Check on a drive of the stack retaining roller, Replace the return belt U-turn HP sensor (SR5) , Replace the stack delivery motor (M2)
E514-0002 End assist motor error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the end assist motor rotates for a specific period of time copyir.ocm Replace the end assist HP sensor (PI39) , Replace the end assist motor (M39)
E519-0001 Gear change motor error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the gear change motor rotates for a specific period of time copyir.ocm Replace the gear change HP sensor (PI49) , Replace the gear change motor (M40)
E519-0002 Gear change motor error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the gear change motor rotates for a specific period of time copyir.ocm Replace the gear change HP sensor (PI49) , Replace the gear change motor (M40)
E530-0001 Rear alignment error Finisher-P1
The HP sensor fails to be ON within 2000ms after the rear adjuster plate starts to move to its HP copyir.ocm Replace the rear adjuster plate HP sensor (SR4) , Replace the rear adjuster plate motor (M4)
E530-0001 Front alignment error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the front jog motor rotates for a specific period of time copyir.ocm Replace the front adjuster plate HP sensor (PI36) , Replace the front adjuster plate motor (M33)
E530-0002 Rear alignment error Finisher-P1
The HP sensor fails to be OFF within 1000ms after the rear adjuster plate starts to move from its HP copyir.ocm Replace the rear adjuster plate HP sensor (SR4) , Replace the rear adjuster plate motor (M4)
E530-0002 Front alignment error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the front job motor rotates for a specific period of time copyir.ocm Replace the front adjuster plate HP sensor (PI36) , Replace the front adjuster plate motor (M33)
E531-0001 Staple error Finisher-P1
The HP sensor fails to be ON within 500ms after the staple motor starts to drive in the reverse direction to recover from a staple jam copyir.ocm Replace the stapling HP sensor (SR18) , Replace the staple motor (M9)
E531-0001 Staple error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the staple motor rotates for a specific period of time copyir.ocm Replace the staple HP sensor (PI50) , Replace the staple motor (M41)
E531-0002 Staple error Finisher-P1
The HP sensor fails to be OFF within 500ms after the staple motor starts to drive copyir.ocm Replace the stapling HP sensor (SR18) , Replace the staple motor (M9)
E531-0002 Staple error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the staple motor rotates for a specific period of time copyir.ocm Replace the staple HP sensor (PI50) , Replace the staple motor (M41)
E532-0001 Staple unit shift error Finisher-P1
The HP sensor fails to be ON within 11000ms after the staple unit starts to move to the stapling HP copyir.ocm Replace the stapler slide HP sensor (SR6) , Replace the stapler slide motor (M8)
E532-0001 Staple unit shift error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the staple shift motor rotates for a specific period of time copyir.ocm Replace the stapler shift HP sensor (PI50) , Replace the stapler shift motor (M35)
E532-0002 Staple unit shift error Finisher-P1
The HP sensor fails to be OFF within 1000ms after the staple unit starts to move from its HP copyir.ocm Replace the stapler slide HP sensor (SR6) , Replace the stapler slide motor (M8)
E532-0002 Staple unit shift error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the stapler shift motor rotates for a specific period of time copyir.ocm Replace the stapler shift HP sensor (PI50) , Replace the stapler shift motor (M35)
E535-0001 Swing error Finisher-P1
The HP sensor fails to be ON within 2000ms after the swing arm starts to move to its HP copyir.ocm Check on operation of the stack delivery motor swing mechanism, Replace the swing cam HP sensor (SR7) , Replace the swing cam motor (M5)
E535-0001 Swing error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the swing motor rotates for a specific period of time copyir.ocm Replace the swing HP sensor (PI35) , Replace the swing motor (M36)
E535-0002 Swing error Finisher-P1
The HP sensor fails to be OFF within 1000ms after the swing arm starts to move from its HP copyir.ocm Check on operation of the stack delivery motor swing mechanism, Replace the swing cam HP sensor (SR7) , Replace the swing cam motor (M5)
E535-0002 Swing error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the swing motor rotates for a specific period of time copyir.ocm Replace the swing HP sensor (PI35) , Replace the swing motor (M36)
E537-0001 Front alignment error Finisher-P1
The HP sensor fails to be ON within 2000ms after the front adjuster plate starts to move to its HP copyir.ocm Replace the front adjuster plate HP sensor (SR3) , Replace the front adjuster plate motor (M3) , Replace the adjuster plate drive belt
E537-0001 Rear alignment error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be OFF after the swing motor rotates for a specific period of time copyir.ocm Replace the rear adjuster plate HP sensor (PI37) , Replace the rear adjuster plate motor (M34)
E537-0002 Front alignment error Finisher-P1
The HP sensor fails to be OFF within 1000ms after the front adjuster plate starts to move from its HP copyir.ocm Replace the front adjuster plate HP sensor (SR3) , Replace the front adjuster plate motor (M3) , Replace the adjuster plate drive belt
E537-0002 Rear alignment error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The HP sensor fails to be ON after the swing motor rotates for a specific period of time copyir.ocm Replace the rear adjuster plate HP sensor (PI37) , Replace the rear adjuster plate motor (M34)
E540-0001 Upper tray up/down error
The upper tray up/down motor clock is abnormal copyir.ocm Replace the shift motor (M37) of the tray 1, Replace the shift area sensor PCB of the tray 1
E540-0002 Stack tray up/down error Finisher-P1
Paper surface detection fails to end within 1000ms copyir.ocm Replace the stack tray top paper sensor (SR9) , Replace the stack tray bottom paper sensor (SR10) , Replace the stack tray upper limit sensor (SR13) , Replace the stack tray lower limit sensor (SR12) , Replace the stack tray shift motor (M7)
E540-0002 Upper tray up/down error
Area is abnormal copyir.ocm Replace the shift motor (M37) of the tray 1, Replace the shift area sensor PCB of the tray 1
E540-0003 Stack tray up/down error Finisher-P1
Encoder lock within 200ms fails to reach 10pulse during paper surface detection copyir.ocm Replace the stack tray top paper sensor (SR9) , Replace the stack tray bottom paper sensor (SR10) , Replace the stack tray upper limit sensor (SR13) , Replace the stack tray lower limit sensor (SR12) , Replace the stack tray shift motor (M7)
E540-0003 Upper tray up/down error
The safety switch is activated copyir.ocm Replace the shift motor (M37) of the tray 1, Replace the shift area sensor PCB of the tray 1
E540-0004 Stack tray up/down error Finisher-P1
Outputs of the top paper sensor, bottom paper sensor, tray upper limit sensor, and tray lower limit sensor have abnormality during paper surface detection copyir.ocm Replace the stack tray top paper sensor (SR9) , Replace the stack tray bottom paper sensor (SR10) , Replace the stack tray upper limit sensor (SR13) , Replace the stack tray lower limit sensor (SR12) , Replace the stack tray shift motor (M7)
E542-0001 Lower tray up/down error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The lower tray up/down motor clock is abnormal copyir.ocm Replace the shift motor (M38) of the tray 2, Replace the shift area sensor PCB of the tray 2
E542-0002 Lower tray up/down error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
Area is abnormal copyir.ocm Replace the shift motor (M38) of the tray 2, Replace the shift area sensor PCB of the tray 2
E542-0003 Lower tray up/down error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The safety switch is activated copyir.ocm Replace the shift motor (M38) of the tray 2, Replace the shift area sensor PCB of the tray 2
E577-0001 Paddle error Finisher-P1
The HP sensor fails to be ON within 1500ms after the paper retaining paddle starts to move to its HP copyir.ocm Replace the paddle HP sensor (SR8) , Replace the paddle motor (M6)
E577-0002 Paddle error Finisher-P1
The HP sensor fails to be OFF within 1000ms after the paper retaining paddle starts to move from its HP copyir.ocm Replace the paddle HP sensor (SR8) , Replace the paddle motor (M6)
E580-0001 Stack tray up/down error
The stack tray fails to reach the stack tray height sensor 4sec copyir.ocm after the stack tray up/down motor starts to move up the tray; or the stack tray fails to come out of the height sensor copyir.ocm Check on overload on the stack tray up/down motor, Replace the stack tray up/down motor (M5), Replace the stack tray paper height sensor (S10) , Replace the stack tray up/down motor clock sensor (S9)
E584-0001 Shutter unit error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The shutter open sensor fails to be OFF (The shutter cannot be closed) copyir.ocm Replace the stack ejection motor (M32) , Replace the shutter open/close clutch (CL31), Replace the shutter HP sensor (PI45)
E584-0002 Shutter unit error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
The shutter open sensor fails to be ON (The shutter cannot be opened) copyir.ocm Replace the stack ejection motor (M32) , Replace the shutter open/close clutch (CL31), Replace the shutter HP sensor (PI45)
E590-0001 Puncher motor error
The puncher HP sensor fails to be detected after the puncher motor is driven for 200ms copyir.ocm Replace the puncher HP sensor, Replace the puncher motor
E590-0002 Puncher motor error
The puncher fails to detect the puncher HP sensor after the puncher motor stops during initial operation copyir.ocm Replace the puncher HP sensor, Replace the puncher motor
E591-0001 Puncher dust sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the puncher dust sensor
E591-0002 Puncher dust sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the puncher dust sensor
E592-0001 Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the end sensor
E592-0002 Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the end sensor
E592-0003 Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the side registration sensor 1
E592-0004 Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the side registration sensor 1
E592-0005 Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the side registration sensor 2
E592-0006 Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the side registration sensor 2
E592-0007 Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the side registration sensor 3
E592-0008 Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the side registration sensor 3
E592-0009 Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal copyir.ocm Replace the side registration sensor 4
E592-000A Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal copyir.ocm Replace the side registration sensor 4
E593-0001 Puncher shift motor error
The HP sensor fails to be OFF copyir.ocm Replace the HP sensor, Replace the puncher shift motor
E593-0002 Puncher shift motor error
The HP sensor fails to be ON copyir.ocm Replace the HP sensor, Replace the puncher shift motor
E5F0-0001 Saddle paper positioning error
The paper positioning plate HP sensor fails to be ON after the paper positioning plate motor is driven for 1 copyir.ocm33 sec copyir.ocm Replace the paper positioning plate motor (M4S), Replace the paper positioning plate HP sensor (PI7S)
E5F0-0002 Saddle paper positioning error
The paper positioning plate HP sensor fails to be OFF after the paper positioning plate motor is driven for 1 sec copyir.ocm Replace the paper positioning plate motor (M4S), Replace the paper positioning plate HP sensor (PI7S)
E5F1-0001 Saddle paper folder error ON copyir.ocm
The number of detection pulses for the paper folder motor clock sensor is below the specific level copyir.ocm Replace the paper folder motor (M2S), Replace the paper folder motor clock sensor (PI4S)
E5F1-0002 Saddle paper folder error ON copyir.ocm
The paper folder HP sensor fails to change after the paper folder motor is driven for 3 sec copyir.ocm Replace the paper folder motor (M2S), Replace the paper folder motor clock sensor (PI4S)
E5F2-0001 Saddle guide error
The guide HP sensor fails to be ON after the guide motor is driven for 0 copyir.ocm455 sec copyir.ocm Replace the guide motor (M3S), Replace the guide HP sensor (PI13S)
E5F2-0002 Saddle guide error
The HP sensor fails to be OFF after the guide motor is driven for 1 sec copyir.ocm Replace the guide motor (M3S), Replace the guide HP sensor (PI13S)
E5F3-0001 Saddle alignment error
The adjuster plate HP sensor fails to be ON after the jog motor is driven for 0 copyir.ocm5 sec copyir.ocm (for 1 copyir.ocm67 sec copyir.ocm during initial operation) Replace the jog motor (M5S), Replace the adjuster plate HP sensor (PI5S)
E5F3-0002 Saddle alignment error
The adjuster plate HP sensor fails to be OFF after the jog motor is driven for 1 sec copyir.ocm Replace the jog motor (M5S), Replace the adjuster plate HP sensor (PI5S)
E5F4-0001 Saddle rear side staple error
The stitching HP sensor fails to be ON after the stitcher motor (rear) rotates in the adverse direction for 0 copyir.ocm5 sec copyir.ocm or more copyir.ocm Replace the stitcher motor (rear, M6S), Replace the stitching HP sensor (rear, MS5S)
E5F4-0002 Saddle rear side staple error
The stitching HP sensor fails to be OFF after the stitcher motor (rear) rotates for 0 copyir.ocm5 sec copyir.ocm or more copyir.ocm Replace the stitcher motor (rear, M6S), Replace the stitching HP sensor (rear, MS5S)
E5F5-0001 Saddle front side staple error
The stitching HP sensor fails to be ON after the stitcher motor (front) rotates in the adverse direction for 0 copyir.ocm5 sec copyir.ocm or more copyir.ocm Replace the stitcher motor (front, M7S), Replace the stitching HP sensor (front, MS7S)
E5F5-0002 Saddle front side staple error
The stitching HP sensor fails to be OFF after the stitcher motor (front) rotates for 0 copyir.ocm5 sec copyir.ocm or more copyir.ocm Replace the stitcher motor (front, M7S), Replace the stitching HP sensor (front, MS7S)
E5F6-0001 Saddle paper push-on error
The paper pressure plate HP sensor fails to be ON after the paper pressure plate motor is driven for 0 copyir.ocm3 sec copyir.ocm or more copyir.ocm Replace the paper pressure plate motor (M8S), Replace the paper pressure plate HP sensor (PI14S)
E5F6-0002 Saddle paper push-on error
The paper pressure plate HP sensor fails to be OFF after the paper pressure plate motor is driven for 80ms or more copyir.ocm Replace the paper pressure plate motor (M8S), Replace the paper pressure plate HP sensor (PI14S)
E5F6-0003 Saddle paper push-on error
The number of detection pulses for the paper pressure plate motor clock sensor is below the specific level copyir.ocm Replace the paper pressure plate motor (M8S), Replace the paper pressure plate motor clock sensor (PI1S)
E5F6-0004 Saddle paper push-on error
The paper pressure plate leading edge sensor fails to be OFF after the paper pressure plate motor is driven for 80ms or more copyir.ocm Replace the paper pressure plate motor (M8S), Replace the paper pressure plate leading edge sensor (PI15S)
E5F6-0005 Saddle paper push-on error
The paper pressure plate leading edge sensor fails to be ON after the paper pressure plate motor is driven for 0 copyir.ocm3 sec copyir.ocm or more copyir.ocm Replace the paper pressure plate motor (M8S), Replace the paper pressure plate leading edge sensor (PI15S)
E5F8-0001 Saddle connector error
Disconnection of the guide HP sensor connector is detected copyir.ocm Disconnect and then connect the guide HP sensor (PI13S) connector
E5F8-0002 Saddle connector error
Disconnection of the paper pressure plate HP sensor connector is detected copyir.ocm Disconnect and then connect the paper pressure plate HP sensor (PI14S) connector
E5F8-0003 Saddle connector error
Disconnection of the paper pressure plate leading edge sensor connector is detected copyir.ocm Disconnect and then connect the paper pressure plate leading edge sensor (PI15S) connector
E5F9-0001 Saddle switch error
Open of the inlet cover is detected for 1 sec copyir.ocm or more after the host machine starts initial rotation/printing while the following sensors detect their covers closed copyir.ocm – Inlet cover sensor (PI9S) – Front cover open/close sensor (PI2S) – Delivery cover sensor (PI3S) Or, the front cover switch (MS2S) or the delivery cover switch (MS3S) is open copyir.ocm Replace the inlet cover switch (MS1S), Replace the front cover switch (MS2S), Replace the delivery cover switch (MS3S)
E5F9-0002 Saddle switch error
Open of the front cover switch is detected for 1 sec copyir.ocm or more after the host machine starts initial rotation/printing while the following sensors detect their covers closed copyir.ocm – Inlet cover sensor (PI9S) – Front cover open/close sensor (PI2S) – Delivery cover sensor (PI3S) Replace the front cover switch (MS2S), Replace the delivery cover switch (MS3S)
E5F9-0003 Saddle switch error
Open of the delivery cover switch is detected for 1 sec copyir.ocm or more after the host machine starts initial rotation/printing while the following sensors detect their covers closed copyir.ocm – Inlet cover sensor (PI9S) – Front cover open/close sensor (PI2S) – Delivery cover sensor (PI3S) – Delivery cover switch (MS3S) Replace the inlet cover switch (MS1S), Replace the front cover switch (MS2S), Replace the delivery cover switch (MS3S)
E601-0000 Abnormality of image memory
Communication error of the image memory (SDRAM) Replace the SDRAM
E602 Hard disk error
E604 The image memory (SDRAM) is faulty/insufficient Add on the SDRAM
E609-0008 Abnormal low temperature of the hard disk
At start-up, temperature of the HDD fails to reach the specific level within a specific period of time copyir.ocm Replace the HDD
E609-0009 Abnormal low temperature of the hard disk
During recovery from sleep mode, temperature of the HDD is below the specific level within the specific period of time copyir.ocm Replace the HDD
E610 Failure in the hard disk cryptographic key
E674 FAX board communication error Check on connection between the FAX board and the main controller PCB, Replace the FAX board, Replace the main controller PCB
E677 Abnormality of the external controller Connect an appropriate controller, Re-install the external controller system
E710-0001 IPC initialization error
The status fails to be ready within 3 sec after the IPC chip starts up copyir.ocm Check on connection of the cable
E711-0001 IPC communication error
Error is set to the error register of the IPC chip 4 times or more within 1 copyir.ocm5 sec Check on connection of the cable, Replace the ADF controller PCB, Replace the reader controller PCB
E711-0002 IPC communication error
Error is detected 4 times or more within 1 copyir.ocm5 sec copyir.ocm after communication between the finisher and the printer stops, and recovery ends in failure copyir.ocm Check on connection of the cable, Replace the finisher controller PCB, Replace the DC controller PCB
E712-0001 Communication error between the ADF and the reader
Communication between the reader and the ADF stops, and the communication cannot recover for 5 sec copyir.ocm or more copyir.ocm Check on connection of the cable, Replace the ADF controller PCB, Replace the reader controller PCB
E713-0000 Communication error between the finisher and the printer
Communication between the finisher and the copier stops copyir.ocm Check on connection of the cable, Replace the finisher controller PCB, Replace the DC controller PCB
E717-0001 Communication error with the NE controller
The NE controller connected before the power is turned off fails to be recognized at power-on copyir.ocm Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E717-0002 Communication error with the NE controller
A break in the IPC, IPC communication fails to recover Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E719-0001 Communication error with the coin vender/card reader
The coin vender connected before the power is turned off fails to be recognized at power-on copyir.ocm Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E719-0002 Communication error with the coin vender/card reader
– A break in the IPC cable connected to the coin vender, IPC communication fails to recover – A break in the paper pickup/delivery signal line – Incorrect connection is detected (Short circuit in Tx and Rx of IPC) Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E719-0011 Communication error with the coin vender/card reader
The card reader connected before the power is turned off fails to be recognized at power-on copyir.ocm Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E719-0012 Communication error with the coin vender/card reader
A break in the IPC cable connected to the card reader, IPC communication fails to recover Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
E730 PDL error Reset PDL, Turn OFF and back ON the main power, Format and re-install the whole system copyir.ocm Replace the main controller PCB
E731 UFR PCB error Check on connection of the UFR PCB, Replace the UFR PCB, Replace the main controller PCB
E732-0001 Reader communication error
DDI-S communication error Check on connection between the reader controller PCB and the main controller PCB, Check on the reader power supply
E733-0000 Printer communication error
The printer fails to be detected at startup copyir.ocm Check on connection between the DC controller PCB and the main controller PCB, Check on the printer power supply
E733-0001 Printer communication error
DDI-P communication error Check on connection between the DC controller PCB and the main controller PCB, Check on the printer power supply
E740-0002 Abnormality of the Ethernet board
Incorrect MAC address is detected at start-up Replace the Ethernet board, Replace the main controller PCB (sub LAN-bar)
E740-0003 Abnormality of the Ethernet board
Incorrect network ID is detected at startup copyir.ocm Replace the Ethernet board, Replace the main controller PCB (sub LAN-bar)
E743-0001 DDI communication error
The reader controller PCB detects communication error between the main controller PCB and the reader controller PCB copyir.ocm Disconnect and then connect the reader communication cable connector, Replace the reader controller PCB, Replace the main controller PCB
E744 Language file/BootROM error Upgrade the version of the Language file
E745 Token ring board error Check on connection of the token ring board, Replace the token ring board
E746-0003 Option board error
The UFR PCB for other model is detected at start-up copyir.ocm Replace with an appropriate UFR PCB
E746-0004 Option board error
The main controller PCB (sub) for other model is detected at start-up copyir.ocm Replace with an appropriate main controller PCB (sub)
E747 Main controller PCB error (Image processing ASIC or memory control/communication control ASIC) Turn OFF and back ON the main power, Replace the main controller PCB (main)
E748 Main controller PCB error Disconnect and then connect the main controller PCB (Sub SJ/PE/R), Replace the main controller PCB (Sub SJ/PE/R), Disconnect and then connect the relay PCB (GU-short), Replace the relay PCB (GU-short), Disconnect and then connect the open interface PCB, Replace the open interface PCB, Replace the main controller PCB (main)
E749-0001 Restart in accordance with a change of the product configuration
The BootROM is replaced with a different type (when the PDL option is installed) Turn OFF and back ON the main power to recover
E803-0001 Door close error
Remote (+24V) OFF is detected soon after the door is closed copyir.ocm Check on connection of the front cover open/close switch (SW3) , Replace the front cover open/close switch
E803-0002 Door close error
Remote (+13V) OFF is detected soon after the door is closed Check on connection of the front cover open/close switch (SW3) , Replace the front cover open/close switch
E804-0004 Controller fan error
Stoppage of the controller fan is detected for 16 sec continuously copyir.ocm Check on connection of the controller fan, Replace the controller fan
E805-0001 Fan error
Lock fails to be detected for 5sec continuously while the exhaust fan (front) is driven copyir.ocm Disconnection of the fan connector copyir.ocm Lock signal fails to be sent due to a fan failure copyir.ocm Check on connection of the exhaust fan (front), Replace the exhaust fan (rear)
E805-0002 Fan error
Lock fails to be detected for 5sec continuously while the exhaust fan (rear) is driven copyir.ocm Disconnection of the fan connector copyir.ocm Lock signal fails to be sent due to a fan failure copyir.ocm Check on connection of the exhaust fan (rear), Replace the exhaust fan (rear)
E805-0003 Fan error
Lock fails to be detected for 5sec continuously while the ITB fan is driven copyir.ocm Disconnection of the fan connector copyir.ocm Lock signal fails to be sent due to a fan failure copyir.ocm Check on connection of the ITB fan, Replace the ITB fan
E805-0004 Fan error
Lock fails to be detected for 5sec continuously while the toner intake fan is driven copyir.ocm Disconnection of the fan connector copyir.ocm Lock signal fails to be sent due to a fan failure copyir.ocm Check on connection of the toner intake fan, Replace the toner intake fan