کانونCanon iRC1021iF
E000-0000 Error in start-up of fixing assembly
When 1 sec passed after energization of the heater, the detected temperature of the main thermistor is not 5 deg C or more (0 deg C at power on) copyir.ocm Disconnection of main thermistor, disconnection of fixing heater, error in DC controller PCB copyir.ocm – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
E001-0000 Error in overheating of fixing assembly
The status where the detected temperature of the main thermistor is 225 deg C (approx copyir.ocm 0 copyir.ocm84V equivalent) or more is detected for 0 copyir.ocm5 continuous sec or more copyir.ocm Error in main thermistor, error in DC controller PCB copyir.ocm – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
E001-0001 Error in overheating of fixing assembly
The status where the detected temperature of the sub thermistor is 245 deg C (approx copyir.ocm 2 copyir.ocm12V equivalent) or more is detected for 0 copyir.ocm5 continuous sec or more copyir.ocm Error in sub thermistor, error in DC controller PCB copyir.ocm – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
E003-0000 Error in abnormally low temperature of fixing assembly
The status where the detected temperature of the main thermistor is 100 deg C (approx copyir.ocm 2 copyir.ocm60V equivalent) or less is detected for 0 copyir.ocm5 continuous sec or more copyir.ocm Error in low-voltage power supply PCB, disconnection of main thermistor, error in DC controller PCBor 20 msec copyir.ocm – Replacement of low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
E003-0001 Error in abnormally low temperature of fixing assembly
The status where the detected temperature of the sub thermistor is less than 100 deg C (approx copyir.ocm 0 copyir.ocm38V equivalent) is detected 0 copyir.ocm5 continuous sec or more after energization of the heater copyir.ocm Error in sub thermistor, error in DC controller PCB copyir.ocm – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
E004-0000 Error in fixing power supply drive circuit
Cannot detect the zero cross signal for the specified period or more copyir.ocm Error in fixing control circuit block copyir.ocm – Replacement of low-voltage power supply PCB
E012-0000 Error in activation of motor
When 3 copyir.ocm5 sec passed after activation of ETB motor, the cycle of ETB motor speed detection signal does not become its specified value copyir.ocm Error in ETB motor, error in DC controller PCB copyir.ocm – Replacement of ETB motor – Replacement of DC controller PCB
E012-0001 Error in activation of motor
After ETB motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocm Error in ETB motor, error in DC controller PCB – Replacement of ETB motor – Replacement of DC controller PCB
E012-0002 Error in activation of motor Y
When 2 copyir.ocm5 sec passed after activation of the yellow drum motor, the cycle of drum motor speed detection signal does not become its specified value copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0003 Error in activation of motor Y
After the yellow drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0004 Error in activation of motor M
When 2 copyir.ocm5 sec passed after activation of the magenta drum motor, the cycle of drum motor speed detection signal does not become its specified value copyir.ocm Cause Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0005 Error in activation of motor M
After the magenta drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0006 Error in activation of motor C
Description When 2 copyir.ocm5 sec passed after activation of the cyan drum motor, the cycle of the drum motor speed detection signal does not become its specified value copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0007 Error in activation of motor C
After the cyan drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0008 Error in activation of motor Bk
When 2 copyir.ocm5 sec passed after activation of the black drum motor, the cycle of the drum motor speed detection signal does not become its specified value copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E012-0009 Error in activation of motor Bk
After the black drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocm Error in drum motor, error in DC controller PCB copyir.ocm – Replacement of drum motor – Replacement of DC controller PCB
E014-0000 Error in activation of fixing motor
When 2 copyir.ocm5 sec passed after activation of fixing motor, the cycle of the fixing motor speed detection signal does not become its specified value copyir.ocmor more copyir.ocm Error in fixing motor, error in DC controller PCB copyir.ocm – Replacement of fixing motor – Replacement of DC controller PCB
E014-0001 Error in activation of fixing motor
After the fixing motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more copyir.ocmore copyir.ocm Error in fixing motor, error in DC controller PCB copyir.ocm – Replacement of fixing motor – Replacement of DC controller PCB
E015-0000 Failure in developing disengagement
Developing cylinder disengagement mechanism does not function correctly copyir.ocm Developing disengagement mechanism fault, developing disengagement solenoid fault, developing disengagement sensor fault, DC controller PCB fault copyir.ocm Check the developing disengagement mechanism copyir.ocm Replace developing disengagement solenoid copyir.ocm Replace developing disengagement sensor copyir.ocm Replace DC controller PCB copyir.ocm
E020-0000 Error in density sensor
Cannot receive enough light when detecting image density copyir.ocm Dirt on density sensor, error in density sensor, error in DC controller PCB, error in toner cartridge – Replacement of ETB unit – Error in high-voltage joint (Check high-voltage joint for each color, and each joint to high-voltage PCB) – Replacement of DC controller – Replacement of toner cartridge
E024-0000 Toner level sensor failure
Failure output from the toner level sensor (Yellow) copyir.ocm Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault copyir.ocm – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
E024-0001 Toner level sensor failure
Failure output from the toner level sensor (Magenta) copyir.ocm Cause Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault copyir.ocm – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
E024-0002 Toner level sensor failure
Failure output from the toner level sensor (Cyan) copyir.ocm Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault copyir.ocm – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
E024-0003 Toner level sensor failure
Failure output from the toner level sensor (Black) copyir.ocm Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault copyir.ocm – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
E066-0000 Error in environment sensorbly
Failure in environment sensor copyir.ocm Environment sensor fault, DC controller PCB assembly fault copyir.ocm – Replace environment sensor – Replace DC controller PCB
E078-0000 Error in primary transfer estrangement unit
Primary transfer estrangement unit does not function properly copyir.ocm Terminal assembly fault, transfer roller estrangement solenoid fault, EBT unit fault, high-voltage power PCB assembly fault copyir.ocm – Replace ETB estrangement solenoid – Replace ETB unit – Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly)
E100-0000 Error in scanner motor, laser unit, BD
Yellow scanner assembly malfunction copyir.ocm Laser scanner unit fault, DC controller PCB assembly fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E100-0001 Error in scanner motor, laser unit, BD
Magenta scanner assembly malfunction copyir.ocm Laser scanner unit fault, DC controller PCB assembly fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E100-0002 Error in scanner motor, laser unit, BD
Cyan scanner assembly malfunction copyir.ocm Laser scanner unit fault, DC controller PCB assembly fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E100-0003 Error in scanner motor, laser unit, BD
Black scanner assembly malfunction copyir.ocm Laser scanner unit fault, DC controller PCB assembly fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E100-0004 Error in scanner motor, laser unit, BD
Failure output of a magenta BD signal laser scanner unit fault, DC controller PCB fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E100-0005 Error in scanner motor, laser unit, BD
Failure output of a magenta BD signal laser scanner unit fault, DC controller PCB fault copyir.ocm – Replace laser scanner unit – Replace DC controller PCB
E194-0000 Error in CPR sensor
Cannot detect color displacement detection pattern, detected results fall outside the acceptable range copyir.ocm Dirty color displacement detection sensor, color displacement detection sensor fault, DC controller PCB assembly fault, toner cartridge fault copyir.ocm Replace ETB unit – Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly) – Replace DC controller PCB – Replace toner cartridge
E196-0001 Error in DCON ROM
Updating the ROM on the DC controller PCB assembly has been failed copyir.ocm – Replace DC controller PCB
E197-0000 Internal communication error – Replace DC controller PCB – Replace video controller PCB
E198-0000 DC controller memory malfunction
DC controller memory malfunction copyir.ocm DC controller PCB assembly fault copyir.ocm – Replace DC controller PCB assembly
E202-0001 Reader HP sensor fault
Reader HP outward fault copyir.ocm The CCD unit moves backward, but does not move to the home position copyir.ocm – Replace reader HP sensor copyir.ocm – Replace reader motor sensor copyir.ocm – Replace reader unit copyir.ocm
E202-0002 Reader HP sensor fault
Reader HP homeward fault The CCD unit moves forward, but does not move to the home position copyir.ocm – Replace reader HP sensor copyir.ocm – Replace reader motor sensor copyir.ocm – Replace reader unit copyir.ocm
E225-0000 Error in light intensity of the lamp copyir.ocm
Decrease of light intensity of the lamp copyir.ocm Replace reader unit copyir.ocm
E248-0001 EEPROM access error
Error at EEPROM power-on EEPROM data cannot be read at power-on copyir.ocm Replace reader unit copyir.ocm
E248-0002 EEPROM access error
Error in EEPROM writing EEPROM writing cannot be performed copyir.ocm Replace reader unit copyir.ocm
E248-0003 EEPROM access error
Error in EEPROM reading after writing EEPROM reading cannot be performed after writing is performed copyir.ocm Replace reader unit copyir.ocm
E248-0004 EEPROM access error
Error in EEPROM register writing EEPROM register writing cannot be performed copyir.ocm Replace reader unit copyir.ocm
E351-0000 Main controller PCB fault
Internal error of the main controller PCB Main controller PCB fault copyir.ocm – Check the connection of main controller PCB copyir.ocm – Replace main controller PCB copyir.ocm
E719-0000 Communication error of options
Erroneous communication with card reader (serial communication) – Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on) copyir.ocm – A serial communication error has occurred copyir.ocm (The serial communication error cannot be recovered copyir.ocm) – Check the connectors of the card reader and image processor PCB copyir.ocm – Replace the card reader for normal connection copyir.ocm – Replace the image processor PCB copyir.ocm
E719-0002 Communication error of options
Erroneous communication with coin vendor (serial communication) – Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on) copyir.ocm – A serial communication error has occurred copyir.ocm (The serial communication error cannot be recovered copyir.ocm) – Check the connection between the image processor PCB and serial PCB copyir.ocm – Check the connectors of the serial PCB and coin vendor for normal connection copyir.ocm – Replace the serial PCB copyir.ocm – Check the coin vendor copyir.ocm – Replace the image processor PCB copyir.ocm
E744-0001 Language file/boot ROM/USB memory error
Language file version error The language file version does not match Bootable copyir.ocm Download a language file of the correct version copyir.ocm
E744-0002 Language file/boot ROM/USB memory error
Language file size error The language file is longer than the permitted size copyir.ocm Download a language file of the correct version copyir.ocm
E744-0003 Language file/boot ROM/USB memory error
Language file version error The language file version does not match Bootable copyir.ocm Download a language file of the correct version copyir.ocm
E744-0004 Language file/boot ROM/USB memory error
Language file read error Reading of language file is invalid copyir.ocm Download a language file of the correct version copyir.ocm
E804-0000 Error in power supply fan
The fan lock detection signal is input for about 10 sec or longer continuously copyir.ocm Power supply fault, DC controller PCB fault copyir.ocm – Replace the power supply fan – Replace the DC controller PCB
E805-0005 Error in duplexing fan/CPU fan
The duplexing fan lock detection signal is input for about 10 sec or longer continuously copyir.ocm Duplexing fan fault, DC controller PCB fault copyir.ocm – Replace the duplexing fan – Replace the DC controller PCB
E840-0000 Error in pressure release mechanism
Although passing 2 copyir.ocm5 sec from the start of HP control, HP (pressure condition) cannot be controlled copyir.ocm Fixing drive assembly fault, fixing pressure release cam fault copyir.ocm – Replace the fixing drive assembly – Replace the fixing pressure release cam