195    Serial Number Error
The serial number stored in the memory (EGB) is not correct      copyir.com    EEPROM defective      copyir.com EGB replaced without original EEPROM 1      copyir.com Check the serial number      copyir.com 2      copyir.com If the stored serial number is incorrect, contact your supervisor      copyir.com
202    Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within 5 sec      copyir.com after turning on or changing speed
203    Polygon motor error 2: OFF timeout
The polygon mirror motor does not leave the READY status within 3 sec      copyir.com after the polygon motor switched off      copyir.com
204    Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing      copyir.com    Polygon motor/driver board harness loose or disconnected      copyir.com Polygon motor/driver board defective      copyir.com Laser optics unit defective      copyir.com IPU (EGB) defective 1      copyir.com Replace the interface harness of the laser optics unit      copyir.com 2      copyir.com Replace the laser optics unit      copyir.com 3      copyir.com Replace the EGB (Engine Board)      copyir.com
220    Laser Synchronizing Detection Error: [K]/[Y]
The laser synchronizing detection signal for LDB [K]/[Y] is not output after the LDB unit has turned on while the polygon motor is rotating normally      copyir.com
222    Laser Synchronizing Detection Error: [M]/[C]
The laser synchronizing detection signal for LDB [M]/[C] is not output after the LDB unit has turned on while the polygon motor is rotating normally      copyir.com    Disconnected cable from the laser synchronizing detection unit or defective connection      copyir.com Defective laser synchronizing detector      copyir.com Defective LDB       copyir.com      copyir.com Defective EGB 1      copyir.com Check the connectors      copyir.com 2      copyir.com Replace the laser optics unit      copyir.com 3      copyir.com Replace the EGB      copyir.com
240    LD error
The IPU (EGB) detects a problem at the LD unit      copyir.com    Worn-out LD      copyir.com Disconnected or broken harness of the LD      copyir.com 1      copyir.com Replace the laser optics unit      copyir.com
300    High voltage power output error
The measured voltage is not correct when the EGB measures each charge output (charge, development, image transfer belt unit, and transfer unit)      copyir.com    Disconnected or defective high voltage harness      copyir.com Defective high voltage power supply      copyir.com Defective EGB 1      copyir.com Check or replace the harnesses      copyir.com 2      copyir.com Replace the high voltage power supply board 3      copyir.com Replace the EGB      copyir.com
396    Black drum motor error
The LOCK signal error is detected when the EGB monitors the black drum motor state      copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops      copyir.com)    Disconnected or defective motor harness      copyir.com Motor slips due to excessive load 1      copyir.com Check the harness from the black drum motor      copyir.com Replace it if necessary      copyir.com
397    Color drum motor error
The LOCK signal error is detected when the EGB monitors the color drum motor state      copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops      copyir.com)    Disconnected or defective motor harness      copyir.com Motor slips due to excessive load 1      copyir.com Check the harness from the color drum motor      copyir.com Replace it if necessary      copyir.com
445    ITB (Image Transfer Belt) Unit: Home Position Error
The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit initialization has been done      copyir.com ITB (Image Transfer Belt) Unit: Contact Position Error The ITB contact sensor does not detect the contact position of the ITB for 5 seconds after the ITB unit has moved to the contact position      copyir.com ITB (Image Transfer Belt) Unit: No-contact Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit has moved to no-contact position      copyir.com-    Defective ITB contact motor      copyir.com Defective ITB contact sensor      copyir.com Defective ITB unit 1      copyir.com Replace the ITB contact motor      copyir.com 2      copyir.com Replace the ITB contact sensor      copyir.com 3      copyir.com Replace the ITB unit      copyir.com
480    Agitator Motor Error
The agitator motor error is detected twice for 10 msec during the initialization at power-on or after the cover is closed      copyir.com    Disconnected or defective harness      copyir.com Defective agitator motor 1      copyir.com Check or replace the harness      copyir.com 2      copyir.com Replace the agitator motor      copyir.com
490    ITB (Image Transfer Belt) Unit Set Error
The TM sensor does not detect the reflection from the ITB      copyir.com    No ITB unit in the machine      copyir.com Dirty TM sensor 1      copyir.com Check the installation of the ITB unit      copyir.com 2      copyir.com Clean the TM sensor      copyir.com
500    Transport/Fusing Motor Error
The LOCK signal error is detected when the EGB monitors the transport/fusing motor state      copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops      copyir.com)    Disconnected or defective motor harness      copyir.com Motor slips due to excessive load 1      copyir.com Check the harness from the transport/fusing motor      copyir.com Replace it if necessary      copyir.com
530    LSU Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued      copyir.com    Disconnected or defective motor harness      copyir.com Defective LSU fan motor 1      copyir.com Check or replace the motor harness      copyir.com 2      copyir.com Replace the LSU fan motor      copyir.com
531    Fusing Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued      copyir.com    Disconnected or defective motor harness      copyir.com Defective LSU fan motor 1      copyir.com Check or replace the motor harness      copyir.com 2      copyir.com Replace the fusing fan motor      copyir.comit
541    Thermistor Error
The thermistor output is less than 0°C for 7 seconds      copyir.com    Disconnected thermistor      copyir.com Defective harness connection 1      copyir.com Check the harness connection of the thermistor      copyir.com 2      copyir.com Replace the fusing unit      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
542    Print Ready Temperature Error
The heating roller temperature increase during a set time is not correct      copyir.com The fusing temperature does not reach the print ready temperature within a set time after the fusing lamp has turned on      copyir.com    Defective thermistor      copyir.com Incorrect power supply input at the main power socket      copyir.com Defective fusing lamp 1      copyir.com Check the voltage of the wall outlet      copyir.com 2      copyir.com Replace the fusing unit 3      copyir.com Replace the fusing lamp      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
543    High Temperature Detection Error
This SC is issued if one of following conditions occurs      copyir.com The thermistor (center) detects 255°C or thermistor (end) detects 245°C      copyir.com The thermistor (center) detects a 3°C increment or more for five seconds at 220°C or more or the thermistor (end) detects a 4°C increment or more for five seconds at 210°C or more      copyir.com    Defective I/O control (EGB)      copyir.com Defective EGB 1      copyir.com Replace the EGB      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
545    Heating Lamp Full-Power Error
The fusing lamp is fully-powered for a certain time while the fusing unit stays in the stand-by mode and is not rotating      copyir.com    Deformed thermistor      copyir.com Thermistor not in the correct position      copyir.com Defective fusing lamp 1      copyir.com Replace the fusing unit      copyir.com 2      copyir.com Replace the fusing lamp      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
547    Zero Cross Error
The zero cross signal is not detected for three seconds even though the fusing lamp relay is on after turning on the main power or closing the front door      copyir.com    Defective fusing lamp relay 1      copyir.com Turn the main power switch off and on      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
548    Low Temperature Error
The center thermistor detects 100°C or less for 4 seconds      copyir.com    Defective fusing lamp      copyir.com Defective thermistor 1      copyir.com Replace the fusing unit      copyir.com 2      copyir.com Replace the fusing lamp      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
557    Zero Cross Frequency Error
The detection error occurs ten times consecutively in ten zero cross signal detections      copyir.com This error is defined when the detected zero cross signal is 17 or less/27 or more for 0      copyir.com2 seconds      copyir.com    Defective fusing lamp relay      copyir.com Unstable input power source 1      copyir.com Check the power supply source      copyir.com 2      copyir.com Replace the fusing unit      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.com
559    Consecutive Fusing Jame
The paper jam counter for the fusing unit reaches 3      copyir.com The paper jam counter is cleared if the paper is fed correctly      copyir.com This SC is activated only when this function is enabled with “Engine Maintenance” (default “OFF”)      copyir.com    Defective fusing unit      copyir.com Defective fusing control 1      copyir.com Clear this SC to send a command after a jam removal      copyir.com 2      copyir.com Turn off this function after a jam removal      copyir.com Execute “Engine Maintenance Menu” to recover the machine after completing the recovery procedure      copyir.com Otherwise, the machine continues to issue this SC code and cannot be operated      copyir.comc
669    EEPROM Error
An unexpected value exists in the initialization flag of the EEPROM    EEPROM not initialized      copyir.com Defective EEPROM 1      copyir.com Initialize the EEPROM      copyir.com 2      copyir.com Replace the EEPROM      copyir.com 3      copyir.com Replace the EGB      copyir.com
690    GAVD Communication Error
The ID of the GAVD is not identified during initialization      copyir.com The chip ID of the GAVD cannot be detected by the machine at power-on      copyir.com    Defective EGB 1      copyir.com Replace the EGB      copyir.com
819    Service Cycle Power
Incorrect combination of EGB and controller board      copyir.com An unexpected error occurs in the EEPROM on the controller board      copyir.com    Controller board defective 1      copyir.com Install the correct EGB and controller boards for this machine      copyir.com 2      copyir.com Replace the controller board
823    USB/ Network Device Error
An interface error in the USB connection or NIB connection occurs      copyir.com    Controller board detective 1      copyir.com Replace the controller board      copyir.com
824    EEPROM Error
An EEPROM check error at power-on occurs      copyir.com    Controller board detective 1      copyir.com Replace the controller board      copyir.com
827    On-Board Memory Check Error
An on-board memory check error at power-on occurs      copyir.com    Controller board detective 1      copyir.com Replace the controller board      copyir.com
828    ROM Checksum Error
A ROM checksum error at power-on occurs      copyir.com    1      copyir.com Replace the controller board      copyir.com