کیو سرا میتا fsc8600dn
0100 Backup memory device error Defective EEPROM copyir.com Defective main PWB copyir.com
0120 MAC address data error
For data in which the MAC address is invalid copyir.com Defective EEPROM copyir.com Defective engine PWB copyir.com
0150 Backup memory read/write error (engine PWB)
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively copyir.com Mismatch of reading data from 2 locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Improper installation EEPROM copyir.com Defective engine PWB copyir.com Device damage of EEPROM copyir.com
0160 Backup memory data error (engine PWB)
Reading data from EEPROM is abnormal copyir.com Data damage of EEPROM copyir.com
0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters copyir.com Data damage of EEPROM copyir.com Defective PWB copyir.com
0180 Machine number mismatch
Machine number of main and engine does not match copyir.com Data damage of EEPROM copyir.com
0640 Hard disk error
The hard disk cannot be accessed copyir.com Defective connector cable or poor contact in the connector copyir.com Defective hard disk copyir.com Defective main PWB copyir.com
0800 Image processing error
JAM010X is detected twice copyir.com Defective main PWB copyir.com
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed copyir.com The battery is disconnected from the main PWB copyir.com Defective main PWB copyir.comnnec
0970 12 V power down detect
Power is disconnected during sleepingDetection of the temporary blackout during sleeping (24V is off, 23V is on, only the controller software is running) copyir.com Defective power source PWB copyir.com
0980 24 V power down detect
24V disconnection signal is detected for 1 s and 12V disconnection signal is not detected copyir.com Defective power source PWB copyir.com
1000 MP lift motor error
After the MP lift motor is driven, the ON status of MP lift sensors 1 and 2 cannot be detected for 3 s copyir.com Defective MP plate elevation mechanism copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective MP lift motor copyir.com Defective engine PWB copyir.com
1010 Lift motor 1 error
After cassette 1 is inserted, lift sensor 1 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com The lock signal of the motor is detected continuously for 1 s copyir.com This error is detected 5 times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective lift motor 1 copyir.com Defective engine PWB copyir.com
1020 Lift motor 2 error
After cassette 2 is inserted, lift sensor 2 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com The lock signal of the motor is detected continuously for 1 s copyir.com This error is detected 5 times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective lift motor 2 copyir.com Defective engine PWB copyir.com
1030 PF lift motor 1 error (paper feeder)
After cassette 3 is inserted, PF lift sensor 1 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 1 copyir.com Defective PF main PWB copyir.com
0100 Backup memory device error Defective EEPROM copyir.com Defective main PWB copyir.com
0120 MAC address data error
For data in which the MAC address is invalid copyir.com Defective EEPROM copyir.com Defective engine PWB copyir.com
0150 Backup memory read/write error (engine PWB)
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively copyir.com Mismatch of reading data from 2 locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Improper installation EEPROM copyir.com Defective engine PWB copyir.com Device damage of EEPROM copyir.com
0160 Backup memory data error (engine PWB)
Reading data from EEPROM is abnormal copyir.com Data damage of EEPROM copyir.com
0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters copyir.com Data damage of EEPROM copyir.com Defective PWB copyir.com
0180 Machine number mismatch
Machine number of main and engine does not match copyir.com Data damage of EEPROM copyir.com
0640 Hard disk error
The hard disk cannot be accessed copyir.com Defective connector cable or poor contact in the connector copyir.com Defective hard disk copyir.com Defective main PWB copyir.com
0800 Image processing error
JAM010X is detected twice copyir.com Defective main PWB copyir.com
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed copyir.com The battery is disconnected from the main PWB copyir.com Defective main PWB copyir.comnnec
0970 12 V power down detect
Power is disconnected during sleepingDetection of the temporary blackout during sleeping (24V is off, 23V is on, only the controller software is running) copyir.com Defective power source PWB copyir.com
0980 24 V power down detect
24V disconnection signal is detected for 1 s and 12V disconnection signal is not detected copyir.com Defective power source PWB copyir.com
1000 MP lift motor error
After the MP lift motor is driven, the ON status of MP lift sensors 1 and 2 cannot be detected for 3 s copyir.com Defective MP plate elevation mechanism copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective MP lift motor copyir.com Defective engine PWB copyir.com
1010 Lift motor 1 error
After cassette 1 is inserted, lift sensor 1 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com The lock signal of the motor is detected continuously for 1 s copyir.com This error is detected 5 times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective lift motor 1 copyir.com Defective engine PWB copyir.com
1020 Lift motor 2 error
After cassette 2 is inserted, lift sensor 2 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com The lock signal of the motor is detected continuously for 1 s copyir.com This error is detected 5 times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective lift motor 2 copyir.com Defective engine PWB copyir.com
1030 PF lift motor 1 error (paper feeder)
After cassette 3 is inserted, PF lift sensor 1 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 1 copyir.com Defective PF main PWB copyir.com
1040 PF lift motor 2 error (paper feeder)
After cassette 4 is inserted, PF lift sensor 2 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 2 copyir.com Defective PF main PWB copyir.com
1050 SM lift motor error (side multi tray)
[45 ppm/55 ppm model] After cassette 5 is inserted, SM lift sensor does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective SM lift motor copyir.com Defective SM main PWB copyir.com
1060 PF lift motor 1 error (side paper feeder)
After cassette 6 is inserted, PF lift sensor 1 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com *:The software over-current protection monitor signal has been detected for 200ms or longer where LFC is installed Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 1 copyir.com Defective PF main PWB copyir.com
1070 PF lift motor 2 error (side paper feeder)
After cassette 7 is inserted, PF lift sensor 2 does not turn on within 12 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively copyir.com However, the first 1 s after motor is turned on is excluded from detection copyir.com *:The software over-current protection monitor signal has been detected for 200ms or longer where LFC is installed Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 2 copyir.com Defective PF main PWB copyir.com
1100 PF lift motor 1 error (large capacity feeder)
After cassette 3 is inserted, PF lift sensor 1 does not turn on within 23 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 200 ms or more 5 times successively copyir.com However, the first 1 s after PF lift motor 1 is turned on is excluded from detection copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 1 copyir.com Defective PF main PWB copyir.com
1110 PF lift motor 2 error (large capacity feeder)
After cassette 4 is inserted, PF lift sensor 2 does not turn on within 23 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 200 ms or more 5 times successively copyir.com However, the first 1 s after PF lift motor 2 is turned on is excluded from detection Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF lift motor 2 copyir.com Defective PF main PWB copyir.com
1140 SD lift motor error (side deck)
After cassette 5 is inserted, SD lift sensor does not turn on within 30 s copyir.com The lock signal of the motor is detected continuously for 200 ms copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective SD lift motor copyir.com Defective SD main PWB copyir.com
1250 SM multi feed sensor communication error (side multi tray)
A communication error is detected 3 times in succession copyir.com Improper installation side multi tray copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com Defective SM main PWB copyir.com
1350 SM multi feed sensor error (side multi tray)
The SM multi feed sensor has detected multi feeding 5 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective SM multi feed sensor copyir.com Defective SM main PWB copyir.com
1450 SM multi feed sensor backup error (side multi tray)
When writing the data, read and write data does not match 3 times in succession copyir.com Deleting a block has failed three times in a row copyir.com Writing won’t complete in 200 ms after writing has commenced copyir.com Defective connector cable or poor contact in the connector copyir.com Defective SM multi feed sensor copyir.com Defective SM main PWB copyir.com
1800 Paper feeder communication error
A communication error from paper feeder is detected 10 times in succession copyir.com Improper installation paper feeder copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com Defective PF main PWB copyir.com
1810 Side multi tray communication error
A communication error from paper feeder is detected 10 times in succession copyir.com Improper installation side multi tray copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com Defective SM main PWB copyir.com
1820 Side paper feeder communication error
A communication error from paper feeder is detected 10 times in succession copyir.com Improper installation side paper feeder copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com Defective SM main PWB copyir.com Defective PF main PWB copyir.com
1900 Paper feeder EEPROM error
When writing the data, read and write data does not match 3 times in succession copyir.com Defective PF main PWB copyir.com Device damage of EEPROM copyir.com
1910 Side multi tray EEPROM error
When writing the data, read and write data does not match 3 times in succession copyir.com Defective SM main PWB copyir.com Device damage of EEPROM copyir.com
1920 Side paper feeder EEPROM error
When writing the data, read and write data does not match 3 times in succession copyir.com Defective PF main PWB copyir.com Device damage of EEPROM copyir.com
1950 Transfer belt unit EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively copyir.com Mismatch of reading data from 2 locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective transfer belt unit copyir.com
2101 Developer motor K error
After developer motor K is driven, the ready signal does not turn to L within 5 s copyir.com After developer motor K is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective developer motor K copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2103 Developer motor MCY error
After developer motor MCY is driven, the ready signal does not turn to L within 5 s copyir.com After developer motor MCY is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective developer motor MCY copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2201 Drum motor K steady-state error
After drum motor K is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor K copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2202 Drum motor C steady-state error
After drum motor C is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor C copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2203 Drum motor M steady-state error
After drum motor M is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor M copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2204 Drum motor Y steady-state error
After drum motor Y is stabilized, the ready signal is at the H level for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor Y copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2211 Drum motor K startup error
Drum motor K is not stabilized within 5 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor K copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2212 Drum motor C startup error
Drum motor C is not stabilized within 5 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor C copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2213 Drum motor M startup error
Drum motor M is not stabilized within 5 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor M copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2214 Drum motor Y startup error
Drum motor Y is not stabilized within 5 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective drum motor Y copyir.com Defective Motor control PWB copyir.com Defective engine PWB copyir.com
2300 Fuser motor error
After fuser motor is driven, the ready signal does not turn to L within 2 s copyir.com After fuser motor is stabilized, the ready signal is at the H level for 1 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective fuser motor copyir.com Defective engine PWB copyir.com
2500 Paper feed motor error
After paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com After paper feed motor is stabilized, the ready signal is at the H level for 1 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective paper feed motor copyir.com Defective engine PWB copyir.com
2600 PF paper feed motor error (large capacity feeder)
After PF paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF paper feed motor copyir.com Defective PF main PWB copyir.com
2610 PF paper feed motor error (paper feeder)
After PF paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF main PWB copyir.com
2640 SD paper feed motor error (side deck)
After SD paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective SD paper feed motor copyir.com Defective SD main PWB copyir.com
2650 SM paper feed motor error (side multi tray)
After SM paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective SM paper feed motor copyir.com Defective SM main PWB copyir.com
2660 PF paper feed motor error (side large capacity feeder)
After PF paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF paper feed motor copyir.com Defective PF main PWB copyir.com
2670 PF paper feed motor error (side paper feeder)
After PF paper feed motor is driven, the ready signal does not turn to L within 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective PF paper feed motor copyir.com Defective PF main PWB copyir.com
2700 Color release motor error
When the color release motor is driven, the color release sensor does not turn on/off for 5 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective color release motor copyir.com Defective engine PWB copyir.com
2730 Transfer release motor error
When the transfer release motor is driven, the transfer release sensor does not turn on/off for 5 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective transfer release motor copyir.com Defective engine PWB copyir.com
2760 Transfer motor startup error
Transfer motor is not stabilized within 5 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective transfer motor copyir.com Defective engine PWB copyir.com
2770 Transfer skew error
An abnormal value is detected to transfer skew sensor copyir.com Improper installation transfer belt unit copyir.com Defective connector cable or poor contact in the connector copyir.com Defective transfer skew sensor copyir.com Defective engine PWB copyir.com
2780 Transfer skew sensor error
An abnormal value is detected to transfer skew sensor copyir.com Defective connector cable or poor contact in the connector copyir.com Defective transfer skew sensor copyir.com Defective engine PWB copyir.com
2790 Transfer skew motor error
When the transfer skew motor is driven, timeouts (300 ms) were detected twice in a row copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective transfer skew motor copyir.com Defective engine PWB copyir.com
2810 Waste toner motor error
Initialized when an error is constantly observed for 2 s after the waste toner motor is activated copyir.com An error is constantly observed for 2 copyir.com5 s after rebooting copyir.com The lock detect signal won’t be H level three times in a row within 200 ms at 1 copyir.com25 ms cycles after the waste toner motor has been driven copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective waste toner motor copyir.comDefective engine PWB copyir.com
2820 Transfer motor steady-state error
After transfer motor is stabilized, the ready signal is at the H level for 5 s continuously copyir.com The counter value obtained by timer capture is lower than 2200 for 10 times in a row copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective transfer motor copyir.com Defective engine PWB copyir.com
2840 Transfer cleaning motor error
After transfer cleaning motor is driven, the ready signal does not turn to L within 2 s copyir.com After transfer cleaning motor is stabilized, the ready signal is at the H level for 1 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective transfer cleaning motor copyir.com Defective engine PWB copyir.com
2850 Transfer belt motor sensor error
The signal is not received for 100 ms in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective transfer motor copyir.com Defective engine PWB copyir.com
2860 Transfer belt sensor error
The signal is not received for 100 ms in succession copyir.com PWB copyir.com Defective connector cable or poor contact in the connector copyir.com Defective transfer belt sensor copyir.com Defective engine PWB copyir.com
2950 Motor control PWB communication error
A communication error from the motor control PWB is detected 10 times in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor control PWB copyir.com Defective engine PWB copyir.com
4001 Polygon motor K synchronization error
After polygon motor K is driven, the ready signal does not turn to L within 30 s copyir.com The polygon motor speed won’t stabilize within 10 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor K copyir.com Defective engine PWB copyir.com
4002 Polygon motor C synchronization error
After polygon motor C is driven, the ready signal does not turn to L within 30 s copyir.com The polygon motor speed won’t stabilize within 10 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor C copyir.com Defective engine PWB copyir.com
4003 Polygon motor M synchronization error
After polygon motor M is driven, the ready signal does not turn to L within 30 s copyir.com The polygon motor speed won’t stabilize within 10 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor M copyir.com Defective engine PWB copyir.com
4004 Polygon motor Y synchronization error
After polygon motor Y is driven, the ready signal does not turn to L within 30 s copyir.com The polygon motor speed won’t stabilize within 10 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor Y copyir.com Defective engine PWB copyir.com
4011 Polygon motor K steadystate error
After polygon motor K is stabilized, the ready signal is at the H level for 15 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor K copyir.com Defective engine PWB copyir.com
4012 Polygon motor C steadystate error
After polygon motor C is stabilized, the ready signal is at the H level for 15 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor C copyir.com Defective engine PWB copyir.com
4013 Polygon motor M steadystate error
After polygon motor M is stabilized, the ready signal is at the H level for 15 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor M copyir.com Defective engine PWB copyir.com
4014 Polygon motor Y steadystate error
After polygon motor Y is stabilized, the ready signal is at the H level for 15 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective polygon motor Y copyir.com Defective engine PWB copyir.com
4101 BD initialization error K
After polygon motor K is driven, the BD signal is not detected for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB K copyir.com Defective engine PWB copyir.com
4102 BD initialization error C
After polygon motor C is driven, the BD signal is not detected for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB C copyir.com Defective engine PWB copyir.com
4103 BD initialization error M
After polygon motor M is driven, the BD signal is not detected for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB M copyir.com Defective engine PWB copyir.com
4104 BD initialization error Y
After polygon motor Y is driven, the BD signal is not detected for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB Y copyir.com Defective engine PWB copyir.com
4201 BD steady-state error K
The BD signal is not detected copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB K copyir.com Defective engine PWB copyir.com
4202 BD steady-state error C
The BD signal is not detected copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB C copyir.com Defective engine PWB copyir.com
4203 BD steady-state error M
The BD signal is not detected copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB M copyir.com Defective engine PWB copyir.com
4204 BD steady-state error Y
The BD signal is not detected copyir.comector copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PD PWB Y copyir.com Defective engine PWB copyir.com
4300 Polygon motor phase error
ASIC won’t settle in completion of phase adjustment for 2 s after a BD signal is detected copyir.com Defective laser scanner unit copyir.com Defective engine PWB copyir.com
4600 LSU cleaning motor error
After LSU cleaning motor is driven, the ready signal does not turn to L within 2 s copyir.com After LSU cleaning motor is stabilized, the ready signal is at the H level for 1 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective LSU cleaning motor copyir.com Defective engine PWB copyir.com
5101 Main high-voltage error K
Measure the inflowing current when Vpp is varied in 3 steps and verify if the difference of the currents of 0 and step 2 is less than 42 (51 if lower highvoltage board) copyir.com Improper installation charger roller unit K copyir.com Defective connector cable or poor contact in the connector copyir.com Defective high voltage PWB 1 copyir.com Defective engine PWB copyir.com
5102 Main high-voltage error C
Measure the inflowing current when Vpp is varied in 3 steps and verify if the difference of the currents of 0 and step 2 is less than 42 (51 if lower highvoltage board) copyir.com Improper installation charger roller unit C copyir.com Defective connector cable or poor contact in the connector copyir.com Defective high voltage PWB 1 copyir.com Defective engine PWB copyir.com
5103 Main high-voltage error M
Measure the inflowing current when Vpp is varied in 3 steps and verify if the difference of the currents of 0 and step 2 is less than 42 (51 if lower highvoltage board) copyir.com Improper installation charger roller unit M copyir.com Defective connector cable or poor contact in the connector copyir.com Defective high voltage PWB 1 copyir.com Defective engine PWB copyir.com
5104 Main high-voltage error Y
Measure the inflowing current when Vpp is varied in 3 steps and verify if the difference of the currents of 0 and step 2 is less than 42 (51 if lower highvoltage board) copyir.com Improper installation charger roller unit Y copyir.com Defective connector cable or poor contact in the connector copyir.com Defective high voltage PWB 1 copyir.com Defective engine PWB copyir.com
6000 Broken fuser heater wire
Fuser thermistor 1 does not reach 100° C/212 °F even after 60 s during warming up copyir.com The detected temperature of fuser thermistor 1 does not reach the specified temperature (ready indication temperature) for 420 s in warming up after reached to 100° C/212 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Fuser thermostat triggered copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6020 Abnormally high fuser thermistor 1 temperature
Fuser thermistor 1 detects a temperature higher than 240°C/464°F for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Shorted fuser thermistor 1 copyir.com Defective engine PWB copyir.com
6030 Broken fuser thermistor 1 wire
Input from fuser thermistor 1 is 984 or more (A/D value) continuously for 1 s copyir.com Verify if A/D read in the differential output won’t change by 4 or more when it was turned on for 10 seconds in a lowtemperature environment copyir.com Defective connector cable or poor contact in the connector copyir.com Broken fuser thermistor 1 wire copyir.com Fuser thermostat triggered copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6040 Fuser heater error
Input from fuser thermistor 1 is abnormal value continuously for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Broken fuser thermistor 1 wire copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6050 Abnormally low fuser thermistor 1 temperature
Fuser thermistor 1 detects a temperature lower than 100°C/212°F for 1 s after warming up, during ready or during print copyir.com Fuser thermistor 1 detects a temperature lower than 70°C/ 158°F for 1 s during low power mode copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser thermistor 1 copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6120 Abnormally high fuser thermistor 4 temperature
Fuser thermistor 4 detects a temperature higher than 190°C/374°F for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Shorted fuser thermistor 4 copyir.com Defective engine PWB copyir.com
6130 Broken fuser thermistor 4 wire
Input from fuser thermistor 4 is 992 or more (A/D value) continuously for 60 s copyir.com Defective connector cable or poor contact in the connector copyir.com Broken fuser thermistor 4 wire copyir.com Defective fuser IH copyir.com
6150 Abnormally low fuser thermistor 4 temperature
Fuser thermistor 4 detects a temperature lower than 30°C/ 86°F for 1 s after warming up copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser thermistor 4 copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6200 Broken fuser edge heater wire
Fuser thermistor 2 does not reach 100° C/212 °F even after 60 s during warming up copyir.com The detected temperature of fuser thermistor 2 does not reach the specified temperature (ready indication temperature) for 420 s in warming up after reached to 100° C/212 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Fuser thermostat triggered copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6220 Abnormally high fuser thermistor 2 temperature
Fuser thermistor 2 detects a temperature higher than 245°C/473°F for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Shorted fuser thermistor 2 copyir.com Defective engine PWB copyir.com
6230 Broken fuser thermistor 2 wire
The Input signal from the fuser thermistor 2 is 992 or more (A/D value) continuously for 1 s when the temperature at the fuser thermistor 1 is greater than 100°C/212°F during warming up copyir.com Defective connector cable or poor contact in the connector copyir.com Broken fuser thermistor 2 wire copyir.com Fuser thermostat triggered copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6250 Abnormally low fuser thermistor 2 temperature
Fuser thermistor 2 detects a temperature lower than 100°C/212°F for 1 s during ready or print copyir.com Fuser thermistor 2 detects a temperature lower than 50°C/ 122°F for 1 s during warming up copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser thermistor 2 copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6320 Abnormally high fuser thermistor 3 temperature
Fuser thermistor 3 detects a temperature higher than 205°C/401°F for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Shorted fuser thermistor 3 copyir.com Defective engine PWB copyir.com
6330 Broken fuser thermistor 3 wire
Fuser thermistor 3 detects a temperature lower than 20°C/ 68°F continuously for 1 s Defective connector cable or poor contact in the connector copyir.com Broken fuser thermistor 3 wire copyir.com Fuser thermostat triggered copyir.com Defective fuser IH copyir.com Defective engine PWB copyir.com
6600 Fuser belt rotation error
A belt rotating pulse is not received for 1 s copyir.com (Engine CPU) Defective connector cable or poor contact in the connector copyir.com Defective fuser belt sensor copyir.com Defective engine PWB copyir.com
6610 Fuser release motor error
When the fuser release motor is driven, the fuser release sensor does not turn on/off for 5 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of motor copyir.com Defective fuser release motor copyir.com Defective engine PWB copyir.com
6710 Fuser IH PWB CPU reset error
Watch doc timer has been overflowed copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6720 Fuser IH belt rotation error
A belt rotating pulse is not received for 2 s copyir.comtiv Defective connector cable or poor contact in the connector copyir.com Defective fuser belt sensor copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6730 Abnormally high fuser IH PWB temperature 1
The input detect temperature is greater than 105°C/221 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6740 Abnormally high fuser IH PWB temperature 2
The input detect temperature is greater than 105°C/221 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6750 Fuser IH output over-current error
The output current is greater than 90A for 10 ms in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6760 Fuser IH input over-current error
The input current is greater than 20A(100V/120V), 10A(200V) for 100 ms in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6770 Fuser IH low electric power error
The preset power is less than 0 copyir.com6 times of it for 120 ms in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6900 Fuser belt cooling fan error
When the fuser edge fan motor 1 , 2 is driven, alarm signal is detected for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser edge fan motor 1 or 2 copyir.com Defective engine PWB copyir.com
6910 Engine software ready error
The device won’t engage in ready state in 60 minutes after warming-up has began copyir.com Defective engine software copyir.com Defective engine PWB copyir.com
6920 Fuser front fan motor error
When the fuser front fan motor is driven, alarm signal is detected for 5 s continuously Defective connector cable or poor contact in the connector copyir.com Defective fuser front fan motor copyir.com Defective engine PWB copyir.com
6930 Fuser rear fan motor error
When the fuser rear fan motor is driven, alarm signal is detected for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser rear fan motor copyir.com Defective engine PWB copyir.com
6940 IH fan motor error
When the IH fan motor is driven, the alarm signal is detected for 5 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective IH fan motor copyir.com Defective engine PWB copyir.com
6950 Fuser IH PWB communication error
No response is received in 30 ms since a command is sent to IHCPU copyir.com A checksum error is detected 10 times in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com
6960 Current PWB error
Less than 1A is continuously observed for 5 s copyir.com Defective current PWB copyir.com
6990 Fuser power supply incompatibility
Information won’t match between the engine backup and the fuser IH PWB copyir.com Differences in settings after initialization copyir.com Defective fuser IH PWB copyir.com Defective engine PWB copyir.com Data damage of EEPROM copyir.com
7001 Toner motor K error
When the toner motor K is driven, the pulse sensor is not detected for 15 times in 200 ms intervals has occurred in 15 times copyir.com During the toner motor is driven, an event in which TMOT_LOCK turns to H (locked) 5 times has occurred in 15 sets copyir.com Defective connector cable or poor contact in the connector copyir.com Defective screw sensor K copyir.com Defective toner motor K copyir.com Defective engine PWB copyir.com
7002 Toner motor C error
When the toner motor K is driven, the pulse sensor is not detected for 15 times in 200 ms intervals has occurred in 15 times copyir.com During the toner motor is driven, an event in which TMOT_LOCK turns to H (locked) 5 times has occurred in 15 sets copyir.com Defective connector cable or poor contact in the connector copyir.com Defective screw sensor C copyir.com Defective toner motor C copyir.com Defective engine PWB copyir.com
7003 Toner motor M error
When the toner motor K is driven, the pulse sensor is not detected for 15 times in 200 ms intervals has occurred in 15 times copyir.com During the toner motor is driven, an event in which TMOT_LOCK turns to H (locked) 5 times has occurred in 15 sets copyir.com Defective connector cable or poor contact in the connector copyir.com Defective screw sensor M copyir.com Defective toner motor M copyir.com Defective engine PWB copyir.com
7004 Toner motor Y error
When the toner motor K is driven, the pulse sensor is not detected for 15 times in 200 ms intervals has occurred in 15 times copyir.com During the toner motor is driven, an event in which TMOT_LOCK turns to H (locked) 5 times has occurred in 15 sets copyir.com Defective connector cable or poor contact in the connector copyir.com Defective screw sensor Y copyir.com Defective toner motor Y copyir.com Defective engine PWB copyir.com
7101 Toner sensor K error
Sensor output value of 60 or less or 944 or more continued for 3 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective toner sensor K copyir.com Failure of locking the developer waste slot at setup copyir.com Defective engine PWB copyir.com
7102 Toner sensor C error
Sensor output value of 60 or less or 944 or more continued for 3 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective toner sensor C copyir.com Failure of locking the developer waste slot at setup copyir.com Defective engine PWB copyir.com
7103 Toner sensor M error
Sensor output value of 60 or less or 944 or more continued for 3 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective toner sensor M copyir.com Failure of locking the developer waste slot at setup copyir.com Defective engine PWB copyir.com
7104 Toner sensor Y error
Sensor output value of 60 or less or 944 or more continued for 3 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective toner sensor Y copyir.com Failure of locking the developer waste slot at setup copyir.com Defective engine PWB copyir.com
7200 Broken outer temperature sensor 2 wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective outer temperature sensor 2 copyir.com Defective engine PWB copyir.com
7210 Short-circuited outer temperature sensor 2
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective outer temperature sensor 2 copyir.com efective engine PWB copyir.com
7221 Broken LSU thermistor K wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor K copyir.com Defective engine PWB copyir.com
7222 Broken LSU thermistor C wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor C copyir.com Defective engine PWB copyir.com
7223 Broken LSU thermistor M wire The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor M copyir.com Defective engine PWB copyir.com
7224 Broken LSU thermistor Y wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor Y copyir.com Defective engine PWB copyir.com
7231 Short-circuited LSU thermistor K
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor K copyir.com Defective engine PWB copyir.com
7232 Short-circuited LSU thermistor C
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor C copyir.com Defective engine PWB copyir.com
7233 Short-circuited LSU thermistor M
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor M copyir.com Defective engine PWB copyir.com
7234 Short-circuited LSU thermistor Y
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective LSU thermistor Y copyir.com Defective engine PWB copyir.com
7241 Broken developer thermistor K wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor K copyir.com Defective engine PWB copyir.com
7242 Broken developer thermistor C wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor C copyir.com Defective engine PWB copyir.com
7243 Broken developer thermistor M wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor M copyir.com Defective engine PWB copyir.com
7244 Broken developer thermistor Y wire
The sensor input sampling is greater than 230 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor Y copyir.com Defective engine PWB copyir.com
7251 Short-circuited developer thermistor K
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor K copyir.com Defective engine PWB copyir.com
7252 Short-circuited developer thermistor C
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor C copyir.com Defective engine PWB copyir.com
7253 Short-circuited developer thermistor M
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor M copyir.com Defective engine PWB copyir.com
7254 Short-circuited developer thermistor Y wire
The sensor input sampling is less than 69 copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer thermistor Y copyir.com Defective engine PWB
7401 Developer unit K type mismatch error
Absence of the developer unit K is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7402 Developer unit C type mismatch error
Absence of the developer unit C is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7403 Developer unit M type mismatch error
Absence of the developer unit M is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7404 Developer unit Y type mismatch error
Absence of the developer unit Y is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7601 ID sensor 1 error
An abnormal value is detected in the input data to ID sensor 1 copyir.com Dark potential error FrontDarkP and FrontDarkS are greater than 0 copyir.com80V copyir.com Light potential error FrontBrightS is smaller than FrontDarkS copyir.com FrontBrightP is smaller than FrontDarkP + 0 copyir.com5V copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com
7602 ID sensor 2 error
Dark potential error RearDarkP and RearDarkS are greater than 0 copyir.com80V copyir.com Light potential error RearBrightS is smaller than RearDarkS copyir.com RearBrightP is smaller than RearDarkP + 0 copyir.com5V copyir.com Defective connector cable or poor contact in the connector copyir.com Defective engine PWB copyir.com
7800 Broken outer temperature sensor 1 wire
The device did not respond for more than 5 ms during reading, in 5 times copyir.com Defective connector cable or poor contact in the connector copyir.com Defective outer temperature sensor 1 copyir.com Defective engine PWB copyir.com
7901 Drum K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drum PWB K copyir.com
7902 Drum C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drum PWB C copyir.com
7903 Drum M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drum PWB M copyir.com
7904 Drum Y EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drum PWB Y copyir.com
7911 Developer unit K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer unit K copyir.com
7912 Developer unit C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer unit C copyir.com
7913 Developer unit M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer unit M copyir.com
7914 Developer unit Y EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective developer unit Y copyir.com
7941 Laser scanner unit K EEPROM error
Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APC PWB K copyir.com
7942 Laser scanner unit C EEPROM error
Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APC PWB C copyir.com
7943 Laser scanner unit M EEPROM error
Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APC PWB M copyir.com
7944 Laser scanner unit Y EEPROM error
Mismatch of reading data from two locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APC PWB Y copyir.com
8010 Punch motor error 1
When the punch motor is driven, punch home position sensor does not turn on within 200 ms copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective punch home position sensor copyir.com Defective punch motor copyir.com Defective PWB copyir.com
8020 Punch motor error 2
Home position is not obtained in 3 s after home position is initialized or in standby copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective punch motor copyir.com Defective PWB copyir.com
8030 Punch motor error 3
Home position does not turn from On to Off in 50 ms after home position has been initialized copyir.comc? Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective punch motor copyir.com Defective PWB copyir.com
8040 Abnormal simultaneous connection of mailbox
When the mailbox is installed in both the main unit and the finisher copyir.com When the mailbox is installed in both the main unit and the finisher copyir.com
8090 DF paddle motor error
When the DF paddle motor is driven, DF paddle sensor does not turn on within 1 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF paddle sensor copyir.com Defective DF paddle motor copyir.com Defective DF main PWB copyir.com
8100 DF eject release motor error
When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com
8110 DF shift motor 1 error (4000-sheet finisher)
When the DF shift motor 1 is driven, DF shift sensor 1 does not turn on within 160 ms copyir.com Defective connector cable or poor contact in the connector copyir.com Defective DF shift sensor 1 copyir.com Defective DF shift motor 1 copyir.com Defective DF main PWB copyir.com
8120 DF shift motor 2 error (4000-sheet finisher)
When the DF shift motor 2 is driven, DF shift sensor 2 does not turn on within 160 ms copyir.com Defective connector cable or poor contact in the connector copyir.com Defective DF shift sensor 2 copyir.com Defective DF shift motor 2 copyir.com Defective DF main PWB copyir.com
8130 DF shift release motor error (4000-sheet finisher)
When the DF shift release motor is driven, DF shift release sensor does not turn on within 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective DF shift release sensor copyir.com Defective DF shift release motor copyir.com Defective DF main PWB copyir.com
8140 DF tray motor error 1
When the main tray has started ascending, DF tray sensor 1 or DF tray upper surface sensor does not turn on within 20 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective sensor copyir.com Defective DF tray motor copyir.com Defective DF main PWB copyir.com
8150 DF tray motor error 2
When the main tray has descended, DF tray sensor 1 or DF tray upper surface sensor does not turn off within 5 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective sensor copyir.com Defective DF tray motor copyir.com Defective DF main PWB copyir.com
8160 DF tray motor error 3
When the main tray has descended, DF tray sensor 3 does not turn on within 20 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF tray sensor 3 copyir.com Defective DF tray motor copyir.com Defective DF main PWB copyir.com
8170 DF side registration motor 1 error 1
When initial operation, DF side registration sensor 1 does not turn on within 3 s Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF side registration sensor 1 copyir.com Defective DF side registration motor 1 copyir.com Defective DF main PWB copyir.com
8180 DF side registration motor 1 error 2
JAM6810 is detected twice copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF side registration sensor 1 copyir.com Defective DF side registration motor 1 copyir.com Defective DF main PWB copyir.com
8190 DF side registration motor 2 error 1
When initial operation, DF side registration sensor 2 does not turn on within 3 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF side registration sensor 2 copyir.com Defective DF side registration motor 2 copyir.com Defective DF main PWB
8200 DF side registration motor 2 error 2
JAM6910 is detected twice copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF side registration sensor 2 copyir.com Defective DF side registration motor 2 copyir.com Defective DF main PWB copyir.com
8210 DF slide motor error
When initial operation, DF staple sensor does not turn on within 3 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF staple sensor copyir.com Defective DF slide motor copyir.com Defective DF main PWB copyir.com
8230 DF staple motor error 1
Staple JAM (DF) has been detected twice in a row copyir.com (The home position could not be detected in 600 ms since the motor was driven after jam was detected twice copyir.com) Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF staple sensor copyir.com Defective DF staple motor copyir.com Defective DF main PWB copyir.com
8240 DF staple motor error 2
Staple JAM (DF) has been detected twice in a row copyir.com (The second JAM detection condition fullfilled with a lock detection signal maintained 1 V for 500 ms continuously, while the stapler motor was driven copyir.com) Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF staple motor copyir.com Defective DF main PWB copyir.com
8250 DF tray motor error 4
The lock signal of the motor is detected continuously for 10 s copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective DF tray motor copyir.com Defective DF main PWB copyir.com
8300 Center-folding unit communication error (4000-sheet finisher)
Communication with the center- folding unit is not possible copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF set sensor copyir.com Defective PWB copyir.com
8310 CF side registration motor 2 error (4000-sheet finisher)
When initial operation, CF side registration sensor 2 does not turn on within 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF side registration sensor 2 copyir.com Defective CF side registration motor 2 copyir.com Defective CF main PWB copyir.com
8320 CF adjustment motor error (4000-sheet finisher)
When initial operation, CF adjustment sensor does not turn on within 2 copyir.com5 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF adjustment sensor 1, 2 copyir.com Defective CF adjustment motor 1, 2 copyir.com Defective CF main PWB copyir.com
8330 CF blade motor error (4000-sheet finisher)
When initial operation, CF blade sensor does not turn on within 3 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF blade sensor copyir.com Defective CF blade motor copyir.com Defective CF main PWB copyir.com
8340 CF staple motor error 1 (4000-sheet finisher)
Staple JAM (center-folding unit) has been detected twice in a row copyir.com (The home position could not be detected in 600 ms since the motor was driven after jam was detected twice copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF staple sensor copyir.com Defective CF staple motor copyir.com Defective CF main PWB copyir.com
8350 CF side registration motor 1 error (4000-sheet finisher)
When initial operation, CF side registration sensor 1 does not turn on within 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF side registration sensor 1 copyir.com Defective CF side registration motor 1 copyir.com Defective CF main PWB copyir.com
8360 CF main motor error (4000-sheet finisher)
During driving the motor, lock signal is detected for 1 s continuously copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CF main motor copyir.com Defective CF main PWB copyir.com
8370 CF staple motor error 2 (4000-sheet finisher)
Staple JAM (DF) has been detected twice in a row copyir.com (The second JAM detection condition fullfilled with a lock detection signal maintained 1 V for 1000 ms continuously, while the stapler motor was driven copyir.com) Defective connector cable or poor contact in the connector copyir.com Defective CF staple motor copyir.com Defective CF main PWB copyir.com
8410 Punch slide motor error 1
The punch slide sensor won’t turn On when home position has been moved by 30 mm copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective slide sensor copyir.com Defective punch slide motor copyir.com Defective PWB copyir.com
8420 Punch slide motor error 2
In detection of paper edges, the paper edge cannot be detected in 30 mm move copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective punch slide motor copyir.com Defective PWB copyir.com
8430 Punch unit communication error
Communication failed to be established after the punch unit was hooked up copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective PWB copyir.com
8500 Mailbox communication error (4000-sheet finisher)
Communication failed to be established after the mailbox was hooked up copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PWB copyir.com
8510 MB conveying motor error 1 (4000-sheet finisher)
When initial operation, MB home position sensor does not turn on within 5 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective MB home position sensor copyir.com Defective MB conveying motor copyir.com Defective MB main PWB copyir.com
8520 MB conveying motor error 2 (4000-sheet finisher)
When standby operation, MB home position sensor does not turn off within 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective MB home position sensor copyir.com Defective MB conveying motor copyir.com Defective MB main PWB copyir.com
8800 Document finisher main program error Document finisher main program error at power up copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Defective PWB copyir.com
8900 Document finisher backup error
Read and write data does not match 3 times in succession copyir.com Defective connector cable or poor contact in the connector (4000-sheet finisher) copyir.com Defective connector cable or poor contact in the connector (1000-sheet finisher) copyir.com Improper installation EEPROM copyir.com Defective DF main PWB copyir.com
8930 Center-folding unit backup error (4000-sheet finisher)
Read and write data does not match 3 times in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Improper installation EEPROM copyir.com Defective CF main PWB copyir.com
F000 Communication error between main PWB and operation PWB Defective main PWB copyir.com Defective operation PWB copyir.com
F010 Main PWB checksum error Defective main PWB copyir.com
F040 Communication error between main PWB and print engine Defective main PWB copyir.com Defective engine PWB copyir.com
F050 Print engine ROM checksum error Defective engine software copyir.com Defective engine PWB copyir.com
F278 Power supply in drive system error The main power switch was turned off before the machine was shutdown, or a power failure has occurred copyir.com