0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem copyir.com Defective FAX control PWB copyir.com
0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted copyir.com Defective fax software copyir.com Defective FAX control PWB copyir.com
0100 Backup memory device error Defective flash memory copyir.com Defective control PWB copyir.com Defective flash memory copyir.com Defective control PWB copyir.com
0120 MAC address data error Defective flash memory copyir.com
0130 Backup memory read/write error Defective flash memory copyir.com Defective control PWB
0140 Backup memory data error Defective flash memory copyir.com Defective control PWB copyir.com
0150 Control PWB EEPROM error
Detecting control PWB EEPROM (U17) communication error copyir.com Improper installation control PWB EEPROM (U17) copyir.com Defective control PWB copyir.com
0170 Billing counting error Defective control PWB copyir.com Data damage of control PWB EEPROM (U17) copyir.com
0180 Machine number mismatch
Machine number of main and engine does not match copyir.com The main PWB or the engine PWB were exchanged copyir.com Data damage of control PWB EEPROM (U17) copyir.com
0420 Paper feeder communication error
Communication error between control PWB and optional paper feeder copyir.com Improper installation paper feeder copyir.com Defective harness between control PWB (YC30) and paper feeder interface connector, or improper connector insertion copyir.com Defective control PWB copyir.com Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion copyir.com Defective PF mainPWB copyir.com
0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB copyir.com Defective fax software copyir.com Defective FAX control PWB copyir.com
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed copyir.com Defective control PWB copyir.com The battery is disconnected from the control PWB copyir.com
0870 FAX control PWB to control PWB high capacity data transfer problem
High-capacity data transfer between the FAX control PWB and the control PWB of the machine was not normally performed even if the data transfer was retried the specified times copyir.com Improper installation FAX control PWB copyir.com Defective FAX control PWB or control PWB copyir.com
0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB copyir.com Defective FAX control PWB copyir.com
2000 Main motor error
The main motor ready input is not given for 2 s during the main motor is ON copyir.com Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion copyir.com Defective drive transmission system of the main motor copyir.com Defective main motor copyir.com Defective control PWB copyir.com
2610 PF paper feed motor error (paper feeder)
The PF paper feed motor of cassette 2 ready input is not given for 2 s during the PF paper feed motor is ON copyir.com Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion copyir.com Defective PF paper feed motor drive transmission system copyir.com Defective PF main motor copyir.com Defective control PWB copyir.com
2620 PF paper feed motor error (Paper feeder)
The PF paper feed motor of cassette 3 ready input is not given for 2 s during the PF paper feed motor is ON copyir.com Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion copyir.com Defective PF paper feed motor drive transmission system copyir.com Defective PF main motor copyir.com Defective control PWB copyir.com
3100 ISU home position errorr copyir.com Defective FFC between CCD PWB (YC1) and control PWB (YC8) copyir.com Defective FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC insertion copyir.com Defective home position sensor copyir.com Defective harness between ISU motor and scanner PWB (YC104), or improper connector insertion copyir.com Defective ISU motor copyir.com
3200 Exposure lamp error
The exposure lamp is not turned on copyir.com Defective FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC insertion copyir.com Defective FFC between CCD PWB (YC1) and control PWB (YC8) copyir.com Defective harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector insertion copyir.com Defective harness between LED drive PWB (YC2) and exposure lamp, or improper connector insertion copyir.com Defective exposure lamp copyir.comsensor copyir.com Defective LED drive PWB copyir.com Defective control PWB copyir.com
3300 AGC error
After AGC, correct input is not obtained at CCD copyir.com Defective FFC between CCD PWB (YC1) and control PWB (YC8) copyir.com Defective exposure lamp copyir.comsensor copyir.com Defective CCD PWB copyir.com Defective control PWB copyir.com
3500 CPU – ASIC (CCD PWB) communication error
An error code is detected copyir.com Defective FFC between CCD PWB (YC1) and control PWB (YC8) copyir.com Defective CCD PWB copyir.com Defective control PWB copyir.com
4000 Polygon motor (laser scanner unit) error
The polygon motor ready input is not given for 6 s during the polygon motor is ON copyir.com Defective harness between polygon motor and control PWB (YC10), or improper connector insertion copyir.com Defective laser scanner unit copyir.com Defective control PWB copyir.com
4200 BD error (laser scanner unit) error BD sensor does not detect laser beam due to condensation on the polygon mirror copyir.com Defective laser scanner unit copyir.com Defective control PWB copyir.com
4700 VIDEO ASIC device error
Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Defective connector cable or poor contact in the connector copyir.com Defective control PWB copyir.com
6000 Broken Fuser heater wire
The fuser temperature does not rise after the Fuser heater has been turned on copyir.com Poor contact in the fuser thermistor connector terminals copyir.com Poor contact in the Fuser heater connector terminals copyir.com Fuser thermistor installed incorrectly copyir.com Fuser thermal cutout triggered copyir.com Fuser heater installed incorrectly copyir.com Broken Fuser heater wire copyir.com
6020 Abnormally high fuser thermistor temperature
Fuser thermistor detects abnormally temperature copyir.com When the temperature of a fuser thermistor detects 195 °C or more at the time of heater OFF and 155 °C or more copyir.com Shorted fuser thermistor copyir.com Defective control PWB copyir.com
6030 Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D value) copyir.com Poor contact in the fuser thermistor connector terminals copyir.com Broken fuser thermistor wire copyir.com Fuser thermistor installed incorrectly copyir.com Fuser thermal cutout triggered copyir.com Fuser heater installed incorrectly copyir.com Broken Fuser heater wire copyir.com
6400 Zero cross signal error
The zero cross signal does not reach the control PWB for specified time copyir.com Defective harness between high voltage PWB (CN202) and control PWB (YC23), or improper connector insertion copyir.com Defective connection between power source PWB (YC103) and high voltage PWB (CN201) copyir.com Defective power source PWB copyir.com Defective control PWB copyir.com
7990 Waste toner full
The waste toner sensor has detected that the waste toner reservoir (drum unit) is full copyir.com Waste toner reservoir (drum unit) is full copyir.com Defective waste toner sensor copyir.com Defective control PWB copyir.com
F000 Control PWB – Operation panel PWB communication error Defective harness between operation panel PWB (YC1) and control PWB (YC7), or improper connector insertion copyir.com motor is ON copyir.com Defective operation panel PWB copyir.com Defective control PWB copyir.com
F020 Control PWB RAM checksum error Defective main memory (RAM) on the control PWB copyir.com Defective expanded memory (DIMM) copyir.com
F040 Control PWB engine communication error
A communication error is detected copyir.com Defective control PWB copyir.com
F041 Control PWB – scanner PWB communication error
A communication error is detected copyir.com Defective control PWB or scanner PWB copyir.com
F050 Control PWB engine checksum error Some error may have occurred when downloading the firmware of the control PWB copyir.com Defective control PWB copyir.com