0001    Transport motor malfunction
– The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized      copyir.com
001B    Rack rotation failure
– The rack positioning sensor is in the blocked state when the rack motor remains deenergized      copyir.com
– The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized      copyir.com
– The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning      copyir.com
– The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning      copyir.com
004C    Ozone ventilation fan motor malfunction
– The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started      copyir.com
– The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated      copyir.com
004E    Power supply cooling fan motor malfunction
– The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized      copyir.com
0092    Transfer belt rotation failure
– The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated      copyir.com
0094    2nd image transfer pressure /retraction failure
– The state of the 2nd image transfer retraction position sensor is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive      copyir.com
– The 2nd image transfer retraction position sensor is in the unblocked state even after the lapse of a predetermined period of time during predrive      copyir.com
– The 2nd image transfer retraction position sensor is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started      copyir.com
– The 2nd image transfer retraction position sensor is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started      copyir.com
0300    Polygon motor malfunction
– A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started      copyir.com
– The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized      copyir.com
0310    Laser malfunction
– The SOS signal is not detected within a predetermined period of time after the output of a laser has been started
– The SOS signal is never detected in the image area      copyir.com
0500    Fuser warm-up failure
– The thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed      copyir.com
0502    Thermistor open-circuit failure
– The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started      copyir.com
0503    Thermistor resistance failure
– The heater lamp remains ON for a predetermined consecutive period of time      copyir.com
0510    Abnormally low fuser temperature
– The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time      copyir.com
0520    Abnormally high fuser temperature
– The temperature detected by the thermistor is a predetermined value or higher for a predetermined period of time      copyir.com
0F51    Waste toner full sensor trouble
– Waste toner full sensor detects abnormal situation      copyir.com
13C0    Printer control board malfunction
– Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out      copyir.com
13DD    Backup data error
– The printer determines that EEPROM is yet to be mounted when the main power switch is turned ON      copyir.com
13E2    Flash ROM write error
– Flash ROM writing is found faulty during a check      copyir.com
13F0    Engine control failure
– An undefined malfunction occurs in the engine section (PRCB, etc      copyir.com)      copyir.com
3C00    EEPROM installation error
– Contact the responsible people of EPSON when not returning in power switch OFF/ON      copyir.com
3C10    EEPROM data error
– Contact the responsible people of EPSON when not returning in power switch OFF/ON      copyir.com