کانون Canon iR Advance C350
E001-A001 Fixing Main Thermistor high temperature detection error
The Fixing Main Thermistor detected 265 deg C or higher for 0 copyir.com1 sec or longer copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A002 Fixing Sub Thermistor (Front) high temperature detection error
The Fixing Sub Thermistor (Front) detected 290 deg C or higher for 0 copyir.com1 sec or longer copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A003 Fixing Sub Thermistor (Rear) high temperature detection error
The Fixing Sub Thermistor (Rear) detected 290 deg C or higher for 0 copyir.com1 sec or longer copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A004 Fixing Main Thermistor high temperature detection error
The Fixing Main Thermistor detected 270 deg C or higher [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A005 Fixing Sub Thermistor (Front) high temperature detection error
The Fixing Sub Thermistor (Front) detected 295 deg C or higher copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A006 Fixing Sub Thermistor (Rear) high temperature detection error
The Fixing Sub Thermistor (Rear) detected 295 deg C or higher copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A001 Fixing Main Thermistor temperature increase detection error
The Fixing Main Thermistor detected a temperature increase of 1 deg C for less than 5 sec from turning ON the main power until start of PI control copyir.com [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A002 Fixing Main Thermistor open circuit detection error
The Fixing Main Thermistor detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control copyir.com [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A003 Fixing Sub Thermistor (Front) open circuit detection error
The Fixing Sub Thermistor (Front) detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control copyir.com [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A004 Fixing Sub Thermistor (Rear) open circuit detection error
The Fixing Sub Thermistor (Rear) detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control copyir.com [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E003-A001 Fixing Main Thermistor low temperature detection error (during printing)
The Fixing Main Thermistor detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E003-A002 Fixing Sub Thermistor (Front) low temperature detection error
The Fixing Sub Thermistor (Front) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRESs
E003-A003 Fixing Sub Thermistor (Rear) low temperature detection error
The Fixing Sub Thermistor (Rear) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E004-0001 Fixing Relay welding detection error
Zero cross interruption was detected although the Fixing Relay was not turned ON copyir.com [Remedy] Replace the Low-voltage Power Supply PCB copyir.com (Unit of replacement: POWER SUPPLY ASSEMBLY) [Caution] Since an electrical trouble due to error in fixing safety circuit relay is the cause of the error, be sure to replace the Low-voltage Power Supply PCB copyir.com
E004-0002 Fixing Main Thermistor and Fixing Sub Thermistor (Rear) disconnection detection error
Connection could not be detected within 0 copyir.com5 sec when power was supplied to the Fixing Heater copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0001 Fixing pressure timeout error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) (Unit of replacement: CABLE, FIXING ASSEMBLY) – Fixing Pressure Release Sensor (PS13) (Unit of replacement: PHOTO INTERRUPTER) – Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0002 Fixing disengagement timeout error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor copyir.com [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) (Unit of replacement: CABLE, FIXING ASSEMBLY) – Fixing Pressure Release Sensor (PS13) (Unit of replacement: PHOTO INTERRUPTER) – Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0003 Fixing pressure retry error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor copyir.com [Remedy] Replace the Fixing Assembly copyir.com (Unit of replacement: Fixing Assembly)
E009-0004 Fixing disengagement retry error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor copyir.com Replace the Fixing Assembly copyir.com (Unit of replacement: Fixing Assembly)
E010-0001 Bk Drum_ITB Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Bk Drum_ITB Motor in the Main Drive Unit copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the Bk Drum_ITB Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E010-0002 Bk Drum_ITB Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Bk Drum_ITB Motor in the Main Drive Unit copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the Bk Drum_ITB Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E010-0003 Bk Drum_ITB Motor error
There was no FG signal input for 300 msec from the startup of the Bk Drum_ITB Motor in the Main Drive Unit copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the Bk Drum_ITB Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0001 CL Drum Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the CL Drum Motor in the Main Drive Unit copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the CL Drum Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0002 CL Drum Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the CL Drum Motor in the Main Drive Unit copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the CL Drum Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0003 CL Drum Motor error
There was no FG signal input for 300 msec from the startup of the CL Drum Motor in the Main Drive Unit copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester copyir.com a copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1 copyir.com Replace the CL Drum Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0001 Fixing Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Fixing Motor copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed copyir.com 2 copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped) copyir.com 3 copyir.com Replace the Fixing Assembly copyir.com 4 copyir.com Check the harness between the DC Controller PCB and the Fixing Motor copyir.com 5 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Fixing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0002 Fixing Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Fixing Motor copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed copyir.com 2 copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped) copyir.com 3 copyir.com Replace the Fixing Assembly copyir.com 4 copyir.com Check the harness between the DC Controller PCB and the Fixing Motor copyir.com 5 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Fixing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0003 Fixing Motor error
There was no FG signal input for 300 msec from the startup of the Fixing Motor copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed copyir.com 2 copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped) copyir.com 3 copyir.com Replace the Fixing Assembly copyir.com 4 copyir.com Check the harness between the DC Controller PCB and the Fixing Motor copyir.com 5 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Fixing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01A8 ATR Sensor (Y)output error
The output value of the ATR Sensor (Y) in the Drum Unit (Y) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing copyir.com [Related parts] – ATR Sensor (Y) (UN34) (Unit of replacement: DEVE_UNIT_Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the ATR Sensor (Y) (UN34/J6021) and the Drum Unit Memory PCB (Y) (UN12/J6011) (Unit of replacement: DEVE_UNIT_Y) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01B8 ATR Sensor (Y) output error
a copyir.com The output value of the ATR Sensor (Y) in the Drum Unit (Y) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization copyir.com b copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (Y) in the Drum Unit (Y) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization copyir.com [Related parts] – ATR Sensor (Y) (UN34) (Unit of replacement: DEVE_UNIT_Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the ATR Sensor (Y) (UN34/J6021) and the Drum Unit Memory PCB (Y) (UN12/J6011) (Unit of replacement: DEVE_UNIT_Y) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01C0 Error in take-up of Sealing Member (Y)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (Y) copyir.com [Remedy] Replace the Drum Unit (Y) copyir.com (Unit of replacement: DEVE_UNIT_Y)
E020-01F0 Error in toner density (Y) at communication failure of the Drum Unit Memory PCB (Y)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (Y) was not available, and the output value (SigR) of the ATR Sensor (Y) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times copyir.com [Related parts] – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com
E020-02A8 ATR Sensor (M) output error
The output value of the ATR Sensor (M) in the Drum Unit (M) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing copyir.com [Related parts] – ATR Sensor (M) (UN35) (Unit of replacement: DEVE_UNIT_M) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the ATR Sensor (M) (UN35/J6022) and the Drum Unit Memory PCB (M) (UN13/J6012) (Unit of replacement: DEVE_UNIT_M) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-02B8 ATR Sensor (M) output error
a copyir.com The output value of the ATR Sensor (M) in the Drum Unit (M) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization copyir.com b copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (M) in the Drum Unit (M) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization copyir.com [Related parts] – ATR Sensor (M) (UN35) (Unit of replacement: DEVE_UNIT_M) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the ATR Sensor (M) (UN35/J6022) and the Drum Unit Memory PCB (M) (UN13/J6012) (Unit of replacement: DEVE_UNIT_M) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-02C0 Error in take-up of Sealing Member (M)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (M) copyir.com [Remedy] Replace the Drum Unit (M) copyir.com (Unit of replacement: DEVE_UNIT_M)
E020-02F0 Error in toner density (M) at communication failure of the Drum Unit Memory PCB (M)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (M) was not available, and the output value (SigR) of the ATR Sensor (M) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times copyir.com [Related parts] – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com
E020-03A8 ATR Sensor (C) output error
The output value of the ATR Sensor (C) in the Drum Unit (C) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing copyir.com [Related parts] – ATR Sensor (C) (UN36) (Unit of replacement: DEVE_UNIT_C) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the ATR Sensor (C) (UN36/J6023) and the Drum Unit Memory PCB (C) (UN14/J6013) (Unit of replacement: DEVE_UNIT_C) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (C) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-03B8 ATR Sensor (C) output error
a copyir.com The output value of the ATR Sensor (C) in the Drum Unit (C) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization copyir.com b copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (C) in the Drum Unit (C) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization copyir.com [Related parts] – ATR Sensor (C) (UN36) (Unit of replacement: DEVE_UNIT_C) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the ATR Sensor (C) (UN36/J6023) and the Drum Unit Memory PCB (C) (UN14/J6013) (Unit of replacement: DEVE_UNIT_C) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (C) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-03C0 Error in take-up of Sealing Member (C)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (C) copyir.com [Remedy] Replace the Drum Unit (C) copyir.com (Unit of replacement: DEVE_UNIT_C)
E020-03F0 Error in toner density (C) at communication failure of the Drum Unit Memory PCB (C)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (C) was not available, and the output value (SigR) of the ATR Sensor (C) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times copyir.com [Related parts] – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Y) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com
E020-04A8 ATR Sensor (Bk) output error
The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing copyir.com [Related parts] – ATR Sensor (Bk) (UN37) (Unit of replacement: P-UNIT_BK) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) (Unit of replacement: P-UNIT_BK) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-04B8 ATR Sensor (Bk) output error
a copyir.com The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization copyir.com b copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (Bk) in the Drum Unit (Bk) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization copyir.com [Related parts] – ATR Sensor (Bk) (UN37) (Unit of replacement: P-UNIT_BK) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) (Unit of replacement: P-UNIT_BK) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-04C0 Error in take-up of Sealing Member (Bk)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (Bk) copyir.com Replace the Drum Unit (Bk) copyir.com (Unit of replacement: P-UNIT_BK)
E020-04F0 Error in toner density (Bk) at communication failure of the Drum Unit Memory PCB (Bk)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (Bk) was not available, and the output value (SigR) of the ATR Sensor (Bk) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times copyir.com – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com
E021-0001 Developing Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Developing Motor copyir.com (The detection timing varies depending on the paper feed conditions copyir.com) [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Developing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0002 Developing Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Developing Motor copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Developing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0003 Developing Motor error
There was no FG signal input for 300 msec from the startup of the Developing Motor copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble copyir.com Perform the following in the order while checking whether the error is cleared copyir.com 1 copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand copyir.com a copyir.com If they cannot be rotated, replace the Main Drive Unit copyir.com b copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB copyir.com 2 copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester copyir.com a copyir.com If the measurement value is less than 1 ohm (conduction state), 1 copyir.com Replace the Developing Motor copyir.com 2 copyir.com Replace the DC Controller PCB copyir.com b copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0120 Developing Screw rotation detection error (Y)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (Y) in the Drum Unit (Y) was 0 copyir.com5 V or less copyir.com [Related parts] – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the Drum Unit Relay PCB (Y) (UN08/J6001) and the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (Y) (UN08) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (Y) (UN12) (Unit of replacement: DEVE_UNIT_Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0220 Developing Screw rotation detection error (M)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (M) in the Drum Unit (M) was 0 copyir.com5 V or less copyir.com [Related parts] – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the Drum Unit Relay PCB (M) (UN09/J6002) and the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (M) (UN09) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (M) (UN13) (Unit of replacement: DEVE_UNIT_M) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0320 Developing Screw rotation detection error (C)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (C) in the Drum Unit (C) was 0 copyir.com5 V or less copyir.com [Related parts] – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the Drum Unit Relay PCB (C) (UN10/J6003) and the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (C) (UN10) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (C) (UN14) (Unit of replacement: DEVE_UNIT_C) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0420 Developing Screw rotation detection error (Bk)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (Bk) in the Drum Unit (Bk) was 0 copyir.com5 V or less copyir.com [Related parts] – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the Drum Unit Relay PCB (Bk) (UN11/ J6004) and the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (Bk) (UN11) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (Bk) (UN15) (Unit of replacement: P-UNIT_BK) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0110 Bottle Motor (YM) error (Y)
The Bottle Rotation Sensor (Y) did not detect rotation for 5 times in a row although 0 copyir.com8 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON copyir.com [Related parts] – Toner Container (Y) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (YM) (M09/J6301) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (Y) 1 copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2 copyir.com Relay Connector (3P) to Bottle Rotation Sensor (Y) (PS06/ J5301) (Unit of replacement: CABLE, BOTTLE SENSOR, Y/C) – Bottle Rotation Sensor (Y) (PS06) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (Y) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (YM) and rotating the drive section by hand copyir.com – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0168 No toner detection error (Y)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (Y) copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (Y) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (Y) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Toner Container (Y) [Remedy] Check/replace the related parts copyir.com [Reference] If a user inserts an empty Toner Container (Y) repeatedly, the error may occur copyir.com
E025-0210 Bottle Motor (YM) error (M)
The Bottle Rotation Sensor (M) did not detect rotation for 5 times in a row although 1 copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON copyir.com [Related parts] – Toner Container (M) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (YM) (M09/J6301) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (M) 1 copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2 copyir.com Relay Connector (3P) to Bottle Rotation Sensor (M) (PS07/ J5302) (Unit of replacement: CABLE, BOTTLE SENSOR, M/K) – Bottle Rotation Sensor (M) (PS07) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (M) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (YM) and rotating the drive section by hand copyir.com – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0268 No toner detection error (M)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (M) copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (M) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (M) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Toner Container (M) [Remedy] Check/replace the related parts copyir.com [Reference] If a user inserts an empty Toner Container (M) repeatedly, the error may occur copyir.com
E025-0310 Bottle Motor (CK) error (C)
The Bottle Rotation Sensor (C) did not detect rotation for 5 times in a row although 1 copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (CK) was turned ON copyir.com [Related parts] – Toner Container (C) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (CK) (M10/J6302) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (C) 1 copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2 copyir.com Relay Connector (3P) to Bottle Rotation Sensor (C) (PS08/ J5303) (Unit of replacement: CABLE, BOTTLE SENSOR, Y/C) – Bottle Rotation Sensor (C) (PS08) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (C) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (CK) and rotating the drive section by hand copyir.com – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0368 No toner detection error (C)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (C) copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (C) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (C) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Toner Container (C) [Remedy] Check/replace the related parts copyir.com [Reference] If a user inserts an empty Toner Container (C) repeatedly, the error may occur copyir.com
E025-0410 Bottle Motor (CK) error (Bk)
The Bottle Rotation Sensor (Bk) did not detect rotation for 5 times in a row although 1 copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (CK) was turned ON copyir.com [Related parts] – Toner Container (Bk) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (CK) (M10/J6302) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (Bk) 1 copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2 copyir.com Relay Connector (3P) to Bottle Rotation Sensor (Bk) (PS09/ J5304) (Unit of replacement: CABLE, BOTTLE SENSOR, M/K) – Bottle Rotation Sensor (Bk) (PS09) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (Bk) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (CK) and rotating the drive section by hand copyir.com – When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/ cable copyir.com [Remedy] Check/replace the related parts copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0468 No toner detection error (Bk)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (Bk) copyir.com [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (Bk) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (Bk) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Toner Container (Bk) [Remedy] Check/replace the related parts copyir.com [Reference] If a user inserts an empty Toner Container (Bk) repeatedly, the error may occur copyir.com
E029-5008 Registration Patch Sensor (Front) light intensity error
The background regular reflection output of the Registration Patch Sensor at the front side did not fall within the specified range for 2 consecutive times at initialization copyir.com [Related parts] – Registration Patch Sensor Unit (Front) (UN31) (Unit of replacement: REGISTRATION SENSOR ASSEMBLY) – Registration Patch Sensor Unit (Front) Shutter (Unit of replacement: SHUTTER, REGISTRATION SENSOR) – Registration Shutter Solenoid (SL03) (Unit of replacement: SOLENOID) – Harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB 1 copyir.com Registration Patch Sensor Unit (Front) (UN31/J5603) to Relay Connector (16P) (Unit of replacement: CABLE, REG copyir.com DETECT) 2 copyir.com Relay Connector (16P) to Relay Connector (16P) (Unit of replacement: CABLE CONNECTING ASSEMBLY) 3 copyir.com Relay Connector (16P) to DC Controller PCB (UN04/J170) (Unit of replacement: 2ST TRANS copyir.com H copyir.comV copyir.com CONTACT ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work copyir.com 1 copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection copyir.com 2 copyir.com Visually check that the harness is not caught or open circuit copyir.com 3 copyir.com If there is any error, replace the corresponding harness/cable copyir.com whether the error is cleared copyir.com Check the background regular reflection output value (front) in COPIER (level 2)> DISPLAY> DENS> P-B-P-C copyir.com a copyir.com If the value is less than 10, 1 copyir.com Check if the sensor window of the Registration Patch Sensor Unit (Front) is soiled copyir.com If it is soiled, clean it with a blower copyir.com 2 copyir.com Check that the Registration Patch Sensor Unit (Front) Shutter is properly installed and it is not damaged or deformed copyir.com If it is deformed or damaged, replace the Registration Patch Sensor Unit (Front) copyir.com 3 copyir.com Check the operation of the Registration Shutter Solenoid copyir.com 3-1 copyir.com If the Registration Shutter Solenoid moves, 3-1-1 copyir.com Replace the Registration Patch Sensor Unit (Front) copyir.com 3-1-2 copyir.com Replace the DC Controller PCB copyir.com 3-2 copyir.com If the solenoid does not move, replace the Registration Shutter Solenoid copyir.com b copyir.com If the value is above 250, 1 copyir.com Check the harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB copyir.com 2 copyir.com Replace the harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB copyir.com 3 copyir.com Replace the Registration Patch Sensor Unit (Front) copyir.com 4 copyir.com Replace the DC Controller PCB copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E996-0CA4 Error for collecting sequence jam log (Printer) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com
E996-0CA9 Error for collecting sequence jam log (Printer) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com
E996-0CAB Error for collecting sequence jam log (Printer) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com
E996-0CAD Error for collecting sequence jam log (Printer) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com
E996-0CAE Error for collecting sequence jam log (Printer) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com
E996-0CAF Error for collecting sequence jam log (Finisher) [Remedy] Collect debug log and contact to the sales company copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error copyir.com