E001-A001    Fixing Main Thermistor high temperature detection error
The Fixing Main Thermistor detected 265 deg C or higher for 0   copyir.com1 sec or longer   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A002    Fixing Sub Thermistor (Front) high temperature detection error
The Fixing Sub Thermistor (Front) detected 290 deg C or higher for 0   copyir.com1 sec or longer   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A003    Fixing Sub Thermistor (Rear) high temperature detection error
The Fixing Sub Thermistor (Rear) detected 290 deg C or higher for 0   copyir.com1 sec or longer   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A004    Fixing Main Thermistor high temperature detection error
The Fixing Main Thermistor detected 270 deg C or higher    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A005    Fixing Sub Thermistor (Front) high temperature detection error
The Fixing Sub Thermistor (Front) detected 295 deg C or higher   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E001-A006    Fixing Sub Thermistor (Rear) high temperature detection error
The Fixing Sub Thermistor (Rear) detected 295 deg C or higher   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A001    Fixing Main Thermistor temperature increase detection error
The Fixing Main Thermistor detected a temperature increase of 1 deg C for less than 5 sec from turning ON the main power until start of PI control   copyir.com    [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A002    Fixing Main Thermistor open circuit detection error
The Fixing Main Thermistor detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control   copyir.com    [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A003    Fixing Sub Thermistor (Front) open circuit detection error
The Fixing Sub Thermistor (Front) detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control   copyir.com    [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E002-A004    Fixing Sub Thermistor (Rear) open circuit detection error
The Fixing Sub Thermistor (Rear) detected a temperature of 40 deg C or lower for 3 sec or longer from turning ON the main power until start of PI control   copyir.com    [Related parts] – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Fixing Assembly (Unit of replacement: Fixing Assembly) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E003-A001    Fixing Main Thermistor low temperature detection error (during printing)
The Fixing Main Thermistor detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E003-A002    Fixing Sub Thermistor (Front) low temperature detection error
The Fixing Sub Thermistor (Front) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRESs
E003-A003    Fixing Sub Thermistor (Rear) low temperature detection error
The Fixing Sub Thermistor (Rear) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E004-0001    Fixing Relay welding detection error
Zero cross interruption was detected although the Fixing Relay was not turned ON   copyir.com    [Remedy] Replace the Low-voltage Power Supply PCB   copyir.com (Unit of replacement: POWER SUPPLY ASSEMBLY) [Caution] Since an electrical trouble due to error in fixing safety circuit relay is the cause of the error, be sure to replace the Low-voltage Power Supply PCB   copyir.com
E004-0002    Fixing Main Thermistor and Fixing Sub Thermistor (Rear) disconnection detection error
Connection could not be detected within 0   copyir.com5 sec when power was supplied to the Fixing Heater   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0001    Fixing pressure timeout error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) (Unit of replacement: CABLE, FIXING ASSEMBLY) – Fixing Pressure Release Sensor (PS13) (Unit of replacement: PHOTO INTERRUPTER) – Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0002    Fixing disengagement timeout error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor   copyir.com    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK ASSEMBLY) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) (Unit of replacement: CABLE, FIXING ASSEMBLY) – Fixing Pressure Release Sensor (PS13) (Unit of replacement: PHOTO INTERRUPTER) – Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Harness between the Low-voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of replacement: CABLE, POWER SUPPLY) – Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E009-0003    Fixing pressure retry error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor   copyir.com    [Remedy] Replace the Fixing Assembly   copyir.com (Unit of replacement: Fixing Assembly)
E009-0004    Fixing disengagement retry error
Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor   copyir.com    Replace the Fixing Assembly   copyir.com (Unit of replacement: Fixing Assembly)
E010-0001    Bk Drum_ITB Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Bk Drum_ITB Motor in the Main Drive Unit   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the Bk Drum_ITB Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E010-0002    Bk Drum_ITB Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Bk Drum_ITB Motor in the Main Drive Unit   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the Bk Drum_ITB Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E010-0003    Bk Drum_ITB Motor error
There was no FG signal input for 300 msec from the startup of the Bk Drum_ITB Motor in the Main Drive Unit   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the Relay Connector (8P) and the DC Controller PCB (UN04/ J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the Bk Drum_ITB Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0001    CL Drum Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the CL Drum Motor in the Main Drive Unit   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the CL Drum Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0002    CL Drum Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the CL Drum Motor in the Main Drive Unit   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the CL Drum Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E012-0003    CL Drum Motor error
There was no FG signal input for 300 msec from the startup of the CL Drum Motor in the Main Drive Unit   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of replacement: POWER SUPPLY ASSEMBLY) – CL Drum Motor (M01) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the CL Drum Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester   copyir.com a   copyir.com If power is flowing to it (the measurement value is less than 1 ohm), 1   copyir.com Replace the CL Drum Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Low-voltage Power Supply PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0001    Fixing Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Fixing Motor   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed   copyir.com 2   copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped)   copyir.com 3   copyir.com Replace the Fixing Assembly   copyir.com 4   copyir.com Check the harness between the DC Controller PCB and the Fixing Motor   copyir.com 5   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Fixing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0002    Fixing Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Fixing Motor   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed   copyir.com 2   copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped)   copyir.com 3   copyir.com Replace the Fixing Assembly   copyir.com 4   copyir.com Check the harness between the DC Controller PCB and the Fixing Motor   copyir.com 5   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Fixing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E014-0003    Fixing Motor error
There was no FG signal input for 300 msec from the startup of the Fixing Motor   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Fixing Assembly (Unit of replacement: Fixing Assembly) – Idler Gear in the Fixing Assembly (Unit of replacement: GEAR, 29T) – Pressure Roller Gear in the Fixing Assembly (Unit of replacement: GEAR, 24T) – Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE) – Fuse in the DC Controller PCB (UN04/FU1) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Fixing Motor (M04) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check that the Fixing Assembly is pushed into the host machine so the handle is locked and there is no backlash while it is installed   copyir.com 2   copyir.com Remove the Fixing Assembly, and rotate the Idler Gear and the Pressure Roller Gear by hand to check visually that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped)   copyir.com 3   copyir.com Replace the Fixing Assembly   copyir.com 4   copyir.com Check the harness between the DC Controller PCB and the Fixing Motor   copyir.com 5   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Fixing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01A8    ATR Sensor (Y)output error
The output value of the ATR Sensor (Y) in the Drum Unit (Y) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing   copyir.com    [Related parts] – ATR Sensor (Y) (UN34) (Unit of replacement: DEVE_UNIT_Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the ATR Sensor (Y) (UN34/J6021) and the Drum Unit Memory PCB (Y) (UN12/J6011) (Unit of replacement: DEVE_UNIT_Y) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01B8    ATR Sensor (Y) output error
a   copyir.com The output value of the ATR Sensor (Y) in the Drum Unit (Y) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization   copyir.com b   copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (Y) in the Drum Unit (Y) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization   copyir.com    [Related parts] – ATR Sensor (Y) (UN34) (Unit of replacement: DEVE_UNIT_Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the ATR Sensor (Y) (UN34/J6021) and the Drum Unit Memory PCB (Y) (UN12/J6011) (Unit of replacement: DEVE_UNIT_Y) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-01C0    Error in take-up of Sealing Member (Y)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (Y)   copyir.com    [Remedy] Replace the Drum Unit (Y)   copyir.com (Unit of replacement: DEVE_UNIT_Y)
E020-01F0    Error in toner density (Y) at communication failure of the Drum Unit Memory PCB (Y)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (Y) was not available, and the output value (SigR) of the ATR Sensor (Y) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times   copyir.com    [Related parts] – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (Y) (UN08/J6001) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com
E020-02A8    ATR Sensor (M) output error
The output value of the ATR Sensor (M) in the Drum Unit (M) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing   copyir.com    [Related parts] – ATR Sensor (M) (UN35) (Unit of replacement: DEVE_UNIT_M) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the ATR Sensor (M) (UN35/J6022) and the Drum Unit Memory PCB (M) (UN13/J6012) (Unit of replacement: DEVE_UNIT_M) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-02B8    ATR Sensor (M) output error
a   copyir.com The output value of the ATR Sensor (M) in the Drum Unit (M) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization   copyir.com b   copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (M) in the Drum Unit (M) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization   copyir.com    [Related parts] – ATR Sensor (M) (UN35) (Unit of replacement: DEVE_UNIT_M) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the ATR Sensor (M) (UN35/J6022) and the Drum Unit Memory PCB (M) (UN13/J6012) (Unit of replacement: DEVE_UNIT_M) – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-02C0    Error in take-up of Sealing Member (M)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (M)   copyir.com    [Remedy] Replace the Drum Unit (M)   copyir.com (Unit of replacement: DEVE_UNIT_M)
E020-02F0    Error in toner density (M) at communication failure of the Drum Unit Memory PCB (M)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (M) was not available, and the output value (SigR) of the ATR Sensor (M) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times   copyir.com    [Related parts] – Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com
E020-03A8    ATR Sensor (C) output error
The output value of the ATR Sensor (C) in the Drum Unit (C) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing   copyir.com    [Related parts] – ATR Sensor (C) (UN36) (Unit of replacement: DEVE_UNIT_C) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the ATR Sensor (C) (UN36/J6023) and the Drum Unit Memory PCB (C) (UN14/J6013) (Unit of replacement: DEVE_UNIT_C) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (C) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-03B8    ATR Sensor (C) output error
a   copyir.com The output value of the ATR Sensor (C) in the Drum Unit (C) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization   copyir.com b   copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (C) in the Drum Unit (C) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization   copyir.com    [Related parts] – ATR Sensor (C) (UN36) (Unit of replacement: DEVE_UNIT_C) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the ATR Sensor (C) (UN36/J6023) and the Drum Unit Memory PCB (C) (UN14/J6013) (Unit of replacement: DEVE_UNIT_C) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (C) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-03C0    Error in take-up of Sealing Member (C)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (C)   copyir.com    [Remedy] Replace the Drum Unit (C)   copyir.com (Unit of replacement: DEVE_UNIT_C)
E020-03F0    Error in toner density (C) at communication failure of the Drum Unit Memory PCB (C)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (C) was not available, and the output value (SigR) of the ATR Sensor (C) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times   copyir.com    [Related parts] – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Y) (UN10/J6003) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com
E020-04A8    ATR Sensor (Bk) output error
The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 245 or less for 2 consecutive times during printing   copyir.com    [Related parts] – ATR Sensor (Bk) (UN37) (Unit of replacement: P-UNIT_BK) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) (Unit of replacement: P-UNIT_BK) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-04B8    ATR Sensor (Bk) output error
a   copyir.com The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization   copyir.com b   copyir.com The output value did not exceed 140 although the control voltage of the ATR Sensor (Bk) in the Drum Unit (Bk) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization   copyir.com    [Related parts] – ATR Sensor (Bk) (UN37) (Unit of replacement: P-UNIT_BK) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) (Unit of replacement: P-UNIT_BK) – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E020-04C0    Error in take-up of Sealing Member (Bk)
The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (Bk)   copyir.com    Replace the Drum Unit (Bk)   copyir.com (Unit of replacement: P-UNIT_BK)
E020-04F0    Error in toner density (Bk) at communication failure of the Drum Unit Memory PCB (Bk)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (Bk) was not available, and the output value (SigR) of the ATR Sensor (Bk) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times   copyir.com    – Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/J6004) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com
E021-0001    Developing Motor error
It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Developing Motor   copyir.com (The detection timing varies depending on the paper feed conditions   copyir.com)    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Developing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0002    Developing Motor error
The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Developing Motor   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Developing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0003    Developing Motor error
There was no FG signal input for 300 msec from the startup of the Developing Motor   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Harness between the Developing Motor (M03) and the DC Controller PCB (UN04/J142) (Unit of replacement: MAIN DRIVE ASSEMBLY) – Fuse in the DC Controller PCB (UN04/FU4) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Developing Motor (M03) (Unit of replacement: MOTOR, DC) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com [Remedy] It is highly possible that the Developing Motor is not rotating due to overload or an electrical trouble   copyir.com Perform the following in the order while checking whether the error is cleared   copyir.com 1   copyir.com Check whether the gears of the Main Drive Unit can be rotated by hand   copyir.com a   copyir.com If they cannot be rotated, replace the Main Drive Unit   copyir.com b   copyir.com If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB   copyir.com 2   copyir.com Measure the both ends of the fuse in the DC Controller PCB using a tester   copyir.com a   copyir.com If the measurement value is less than 1 ohm (conduction state), 1   copyir.com Replace the Developing Motor   copyir.com 2   copyir.com Replace the DC Controller PCB   copyir.com b   copyir.com If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0120    Developing Screw rotation detection error (Y)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (Y) in the Drum Unit (Y) was 0   copyir.com5 V or less   copyir.com    [Related parts] – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Harness between the Drum Unit Relay PCB (Y) (UN08/J6001) and the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (Y) (UN08) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (Y) (UN12) (Unit of replacement: DEVE_UNIT_Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Y) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0220    Developing Screw rotation detection error (M)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (M) in the Drum Unit (M) was 0   copyir.com5 V or less   copyir.com    [Related parts] – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Harness between the Drum Unit Relay PCB (M) (UN09/J6002) and the DC Controller PCB (UN04/J160) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (M) (UN09) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (M) (UN13) (Unit of replacement: DEVE_UNIT_M) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (M) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0320    Developing Screw rotation detection error (C)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (C) in the Drum Unit (C) was 0   copyir.com5 V or less   copyir.com    [Related parts] – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Harness between the Drum Unit Relay PCB (C) (UN10/J6003) and the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (C) (UN10) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (C) (UN14) (Unit of replacement: DEVE_UNIT_C) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (C) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E021-0420    Developing Screw rotation detection error (Bk)
The difference between the maximum and the minimum of sampling values detected by the ATR Sensor (Bk) in the Drum Unit (Bk) was 0   copyir.com5 V or less   copyir.com    [Related parts] – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Harness between the Drum Unit Relay PCB (Bk) (UN11/ J6004) and the DC Controller PCB (UN04/J162) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Relay PCB (Bk) (UN11) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) – Drum Unit Memory PCB (Bk) (UN15) (Unit of replacement: P-UNIT_BK) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) [Points to note at work] – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com – If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0110    Bottle Motor (YM) error (Y)
The Bottle Rotation Sensor (Y) did not detect rotation for 5 times in a row although 0   copyir.com8 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON   copyir.com    [Related parts] – Toner Container (Y) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (YM) (M09/J6301) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (Y) 1   copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2   copyir.com Relay Connector (3P) to Bottle Rotation Sensor (Y) (PS06/ J5301) (Unit of replacement: CABLE, BOTTLE SENSOR, Y/C) – Bottle Rotation Sensor (Y) (PS06) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (Y) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (YM) and rotating the drive section by hand   copyir.com – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0168    No toner detection error (Y)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (Y)   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (Y) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (Y) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (Y) (Unit of replacement: DEVE_UNIT_Y) – Toner Container (Y) [Remedy] Check/replace the related parts   copyir.com [Reference] If a user inserts an empty Toner Container (Y) repeatedly, the error may occur   copyir.com
E025-0210    Bottle Motor (YM) error (M)
The Bottle Rotation Sensor (M) did not detect rotation for 5 times in a row although 1   copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON   copyir.com    [Related parts] – Toner Container (M) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (YM) (M09/J6301) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (M) 1   copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2   copyir.com Relay Connector (3P) to Bottle Rotation Sensor (M) (PS07/ J5302) (Unit of replacement: CABLE, BOTTLE SENSOR, M/K) – Bottle Rotation Sensor (M) (PS07) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (M) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (YM) and rotating the drive section by hand   copyir.com – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0268    No toner detection error (M)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (M)   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (M) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (M) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) – Toner Container (M) [Remedy] Check/replace the related parts   copyir.com [Reference] If a user inserts an empty Toner Container (M) repeatedly, the error may occur   copyir.com
E025-0310    Bottle Motor (CK) error (C)
The Bottle Rotation Sensor (C) did not detect rotation for 5 times in a row although 1   copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (CK) was turned ON   copyir.com    [Related parts] – Toner Container (C) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (CK) (M10/J6302) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (C) 1   copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2   copyir.com Relay Connector (3P) to Bottle Rotation Sensor (C) (PS08/ J5303) (Unit of replacement: CABLE, BOTTLE SENSOR, Y/C) – Bottle Rotation Sensor (C) (PS08) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (C) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (CK) and rotating the drive section by hand   copyir.com – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0368    No toner detection error (C)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (C)   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (C) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (C) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (C) (Unit of replacement: DEVE_UNIT_C) – Toner Container (C) [Remedy] Check/replace the related parts   copyir.com [Reference] If a user inserts an empty Toner Container (C) repeatedly, the error may occur   copyir.com
E025-0410    Bottle Motor (CK) error (Bk)
The Bottle Rotation Sensor (Bk) did not detect rotation for 5 times in a row although 1   copyir.com5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (CK) was turned ON   copyir.com    [Related parts] – Toner Container (Bk) – Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (CK) (M10/J6302) (Unit of replacement: CABLE, MAIN) – Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (Bk) 1   copyir.com DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2   copyir.com Relay Connector (3P) to Bottle Rotation Sensor (Bk) (PS09/ J5304) (Unit of replacement: CABLE, BOTTLE SENSOR, M/K) – Bottle Rotation Sensor (Bk) (PS09) (Unit of replacement: PHOTO INTERRUPTER) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) – Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) – Hopper Unit (Bk) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] – Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (CK) and rotating the drive section by hand   copyir.com – When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/ cable   copyir.com [Remedy] Check/replace the related parts   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E025-0468    No toner detection error (Bk)
The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (Bk)   copyir.com    [Related parts] – Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) – Hopper Unit (Bk) (Unit of replacement: HOPPER ASSEMBLY) – Toner Bottle Mount Unit (Bk) (Unit of replacement: BOTTLE MOUNT ASSEMBLY) – Drum Unit (Bk) (Unit of replacement: P-UNIT_BK) – Toner Container (Bk) [Remedy] Check/replace the related parts   copyir.com [Reference] If a user inserts an empty Toner Container (Bk) repeatedly, the error may occur   copyir.com
E029-5008    Registration Patch Sensor (Front) light intensity error
The background regular reflection output of the Registration Patch Sensor at the front side did not fall within the specified range for 2 consecutive times at initialization   copyir.com    [Related parts] – Registration Patch Sensor Unit (Front) (UN31) (Unit of replacement: REGISTRATION SENSOR ASSEMBLY) – Registration Patch Sensor Unit (Front) Shutter (Unit of replacement: SHUTTER, REGISTRATION SENSOR) – Registration Shutter Solenoid (SL03) (Unit of replacement: SOLENOID) – Harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB 1   copyir.com Registration Patch Sensor Unit (Front) (UN31/J5603) to Relay Connector (16P) (Unit of replacement: CABLE, REG   copyir.com DETECT) 2   copyir.com Relay Connector (16P) to Relay Connector (16P) (Unit of replacement: CABLE CONNECTING ASSEMBLY) 3   copyir.com Relay Connector (16P) to DC Controller PCB (UN04/J170) (Unit of replacement: 2ST TRANS   copyir.com H   copyir.comV   copyir.com CONTACT ASS’Y) – DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work   copyir.com 1   copyir.com Disconnect and then connect the connector to check that there is no bent pin and cable disconnection   copyir.com 2   copyir.com Visually check that the harness is not caught or open circuit   copyir.com 3   copyir.com If there is any error, replace the corresponding harness/cable   copyir.com whether the error is cleared   copyir.com Check the background regular reflection output value (front) in COPIER (level 2)> DISPLAY> DENS> P-B-P-C   copyir.com a   copyir.com If the value is less than 10, 1   copyir.com Check if the sensor window of the Registration Patch Sensor Unit (Front) is soiled   copyir.com If it is soiled, clean it with a blower   copyir.com 2   copyir.com Check that the Registration Patch Sensor Unit (Front) Shutter is properly installed and it is not damaged or deformed   copyir.com If it is deformed or damaged, replace the Registration Patch Sensor Unit (Front)   copyir.com 3   copyir.com Check the operation of the Registration Shutter Solenoid   copyir.com 3-1   copyir.com If the Registration Shutter Solenoid moves, 3-1-1   copyir.com Replace the Registration Patch Sensor Unit (Front)   copyir.com 3-1-2   copyir.com Replace the DC Controller PCB   copyir.com 3-2   copyir.com If the solenoid does not move, replace the Registration Shutter Solenoid   copyir.com b   copyir.com If the value is above 250, 1   copyir.com Check the harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB   copyir.com 2   copyir.com Replace the harness between the Registration Patch Sensor Unit (Front) and the DC Controller PCB   copyir.com 3   copyir.com Replace the Registration Patch Sensor Unit (Front)   copyir.com 4   copyir.com Replace the DC Controller PCB   copyir.com [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx   copyir.com 2 min) and restore the backup data after the replacement so the data may be able to be protected   copyir.com – Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP – Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E996-0CA4    Error for collecting sequence jam log (Printer)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com
E996-0CA9    Error for collecting sequence jam log (Printer)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com
E996-0CAB    Error for collecting sequence jam log (Printer)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com
E996-0CAD    Error for collecting sequence jam log (Printer)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com
E996-0CAE    Error for collecting sequence jam log (Printer)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com
E996-0CAF    Error for collecting sequence jam log (Finisher)    [Remedy] Collect debug log and contact to the sales company   copyir.com [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error   copyir.com