ریکوآفشیو Ricoh Aficio SPC240SF
195 Serial Number Error
The serial number stored in the memory (EGB) is not correct ( copyir.com EEPROM defective ( copyir.com EGB replaced without original EEPROM ( copyir.com
202 Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within 5 sec ( copyir.com after turning on or changing speed Polygon motor/driver board harness loose or disconnected ( copyir.com Polygon motor/driver board defective ( copyir.com Laser optics unit defective ( copyir.com IPU (EGB) defective ( copyir.com
203 Polygon motor error 2: OFF timeout
The polygon mirror motor does not leave the READY status within 3 sec ( copyir.com after the polygon motor switched off ( copyir.com Polygon motor/driver board harness loose or disconnected ( copyir.com Polygon motor/driver board defective ( copyir.com Laser optics unit defective ( copyir.com IPU (EGB) defective ( copyir.com
204 Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing ( copyir.com Polygon motor/driver board harness loose or disconnected ( copyir.com Polygon motor/driver board defective ( copyir.com Laser optics unit defective ( copyir.com IPU (EGB) defective ( copyir.com
220 Laser Synchronizing Detection Error: [K]/[Y]
The laser synchronizing detection signal for LDB [K]/[Y] is not output after the LDB unit has turned on while the polygon motor is rotating normally ( copyir.com Disconnected cable from the laser synchronizing detection unit or defective connection ( copyir.com Defective laser synchronizing detector ( copyir.com Defective LDB ( copyir.com Defective EGB ( copyir.com
222 Laser Synchronizing Detection Error: [M]/[C]
The laser synchronizing detection signal for LDB [M]/[C] is not output after the LDB unit has turned on while the polygon motor is rotating normally ( copyir.com Disconnected cable from the laser synchronizing detection unit or defective connection ( copyir.com Defective laser synchronizing detector ( copyir.com Defective LDB ( copyir.com Defective EGB ( copyir.com
240 LD error
The IPU (EGB) detects a problem at the LD unit ( copyir.com Worn-out LD ( copyir.com Disconnected or broken harness of the LD ( copyir.com
300 High voltage power output error
The measured voltage is not correct when the EGB measures each charge output (charge, development, image transfer belt unit, and transfer unit) ( copyir.com Disconnected or defective high voltage harness ( copyir.com Defective high voltage power supply ( copyir.com Defective EGB ( copyir.com
396 Black drum motor error
The LOCK signal error is detected when the EGB monitors the black drum motor state ( copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops ( copyir.com ) Disconnected or defective motor harness ( copyir.com Motor slips due to excessive load ( copyir.com
397 Color drum motor error
The LOCK signal error is detected when the EGB monitors the color drum motor state ( copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops ( copyir.com ) Disconnected or defective motor harness ( copyir.com Motor slips due to excessive load ( copyir.com
445 ITB (Image Transfer Belt) Unit Error
Home Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit initialization has been done ( copyir.com ITB (Image Transfer Belt) Unit: Contact Position Error The ITB contact sensor does not detect the contact position of the ITB for 5 seconds after the ITB unit has moved to the contact position ( copyir.com ITB (Image Transfer Belt) Unit: No-contact Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit has moved to no-contact position ( copyir.com Defective ITB contact motor ( copyir.com Defective ITB contact sensor ( copyir.com Defective ITB unit ( copyir.com
480 Agitator Motor Error
The agitator motor error is detected twice for 10 msec during the initialization at power-on or after the cover is closed ( copyir.com Disconnected or defective harness ( copyir.com Defective agitator motor ( copyir.com
490 ITB (Image Transfer Belt) Unit Set Error
The TM sensor does not detect the reflection from the ITB ( copyir.com No ITB unit in the machine ( copyir.com Dirty TM sensor ( copyir.com
500 Transport/Fusing Motor Error
The LOCK signal error is detected when the EGB monitors the transport/fusing motor state ( copyir.com (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops ( copyir.com ) Disconnected or defective motor harness ( copyir.com Motor slips due to excessive load ( copyir.com
530 LSU Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued ( copyir.com Disconnected or defective motor harness ( copyir.com Defective LSU fan motor ( copyir.com
531 Fusing Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued ( copyir.com Disconnected or defective motor harness ( copyir.com Defective LSU fan motor ( copyir.com
541 Thermistor Error
The thermistor output is less than 0°C for 7 seconds ( copyir.com Disconnected thermistor ( copyir.com Defective harness connection ( copyir.com
542 Print Ready Temperature Error
The heating roller temperature increase during a set time is not correct ( copyir.com The fusing temperature does not reach the print ready temperature within a set time after the fusing lamp has turned on ( copyir.com Defective thermistor ( copyir.com Incorrect power supply input at the main power socket ( copyir.com Defective fusing lamp ( copyir.com
543 High Temperature Detection Error
This SC is issued if one of following conditions occurs: The thermistor (center) detects 255°C or thermistor (end) detects 245°C ( copyir.com The thermistor (center) detects a 3°C increment or more for five seconds at 220°C or more or the thermistor (end) detects a 4°C increment or more for five seconds at 210°C or more ( copyir.com Defective I/O control (EGB) ( copyir.com Defective EGB ( copyir.com
545 Heating Lamp Full-Power Error
The fusing lamp is fully-powered for a certain time while the fusing unit stays in the stand-by mode and is not rotating ( copyir.com Deformed thermistor ( copyir.com Thermistor not in the correct position ( copyir.com Defective fusing lamp ( copyir.com
547 Zero Cross Error
The zero cross signal is not detected for three seconds even though the fusing lamp relay is on after turning on the main power or closing the front door ( copyir.com Defective fusing lamp relay
548 Low Temperature Error
The center thermistor detects 100°C or less for 4 seconds ( copyir.com Defective fusing lamp ( copyir.com Defective thermistor
557 Zero Cross Frequency Error
The detection error occurs ten times consecutively in ten zero cross signal detections ( copyir.com This error is defined when the detected zero cross signal is 17 or less/27 or more for 0 ( copyir.com 2 seconds ( copyir.com Defective fusing lamp relay ( copyir.com Unstable input power source ( copyir.com
559 Consecutive Fusing Jam
The paper jam counter for the fusing unit reaches 3 ( copyir.com The paper jam counter is cleared if the paper is fed correctly ( copyir.com This SC is activated only when this function is enabled with “Engine Maintenance” (default “OFF”) ( copyir.com Defective fusing unit ( copyir.com Defective fusing control ( copyir.com
669 EEPROM Error
An unexpected value exists in the initialization flag of the EEPROM ( copyir.com EEPROM not initialized ( copyir.com Defective EEPROM ( copyir.com
690 GAVD Communication Error
The ID of the GAVD is not identified during initialization ( copyir.com Defective EGB
819 Service Cycle Power
Incorrect combination of EGB and controller board ( copyir.com An unexpected error occurs in the EEPROM on the controller board Controller board defective
823 USB/ Network Device Error
An interface error in the USB connection or NIB connection occurs ( copyir.com Controller board detective
824 EEPROM Error
An EEPROM check error at power-on occurs ( copyir.com Controller board detective
827 On-Board Memory Check Error
An on-board memory check error at power-on occurs ( copyir.com Controller board detective
828 ROM Checksum Error A ROM checksum error at power-on occurs ( copyir.com