ریکو آفشیو Ricoh Aficio MPC7500SP

ایرادات دستگاههای ریکو براساس کد می باشد. شرکت کپی ایران در نظر دارد تمامی سرویس مانوئلها و رفع ایرادات را در اختیار شما عزیزان قرار دهد.

 

 

792-14    50/100 clamp adjustment error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • 50/100 adjustment motor (M702) connector loose, broken, defective • Motor overload • Motor defective • Ring switch HP sensor (S706) connector loose, broken, defective, or sensor defective • Ring switch timing sensor (S707) connector loose, broken, defective, or sensor defective
792-19    Output belt unit rotation error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 800 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 2300 pulses) (1st detection, jam, 2nd detection, SC error)    • Output belt rotation motor (M403) connector loose, broken, defective • Motor overload • Motor defective • Output belt rotation HP sensor (S403) connector loose, broken, defective • Sensor defective
SC101    Exposure lamp error
The white level peak did not reach the prescribed threshold when the white plate was scanned ( copyir.com     • Dirty optics • Dirty white plate • Exposure lamp defective • Exposure lamp does not turn on • Lamp stabilizer defective • High voltage line leak • SIB defective • SBU defective
SC120    Scanner home position error 1
The scanner home position sensor did not detect the home position (did not go OFF) after the scanner moved forward 20 mm ( copyir.com  ( copyir.com     • Scanner motor defective • Scanner HP sensor defective • Harness between scanner motor and SIOB disconnected or broken ( copyir.com  • SIOB defective
SC121    Scanner home position error 2
The scanner home position sensor did not go ON after the scanner moved forward 6 mm and the feeler entered the HP sensor ( copyir.com     • Scanner motor harness loose, broken, defective • Scanner motor defective • Scanner HP sensor disconnected, defective • SIOB defective
SC141    Black level detection error
During AGC the value for black level was not within ±3 of the prescribed value ( copyir.com     • SBU defective • Harness defective • Check harnesses between SBU and IPU • IPU defective • VBCU defective
SC142    White level detection error
During AGC the value for white level was not within -7 of the prescribed value ( copyir.com     • Exposure lamp defective • Harness disconnected, damaged • Dirty exposure glass, optics • Scanner motor, drive assembly defective • SBU board defective
SC144    SBU communication error
When the machine is switched on, or when the machine returns to full operation from the energy save mode, the machine can not access the SBU register, or the SBU register values are abnormal ( copyir.com  Note: The ASIC IDs read during automatic adjustment of the SBU can be displayed with SP4600 ( copyir.com     • SBU harness loose, disconnected, defective • SBU board defective • VBCU defective
SC161    IPU error
Communication error between IPU, SBU, and VBCU ( copyir.com     • Check harness connections between SBU and IPU/VBCU • IPU defective • VBCU defective
SC161-1    An error occurred when the ASIC executed a self-diagnostic report on the BICU ( copyir.com     • Defective BICU • Defective connection between BICU and SBU
SC161-2    The machine detects an error during an access to the Ri ( copyir.com     • Defective BICU board
SC161-3    The IPU fails to configure or initialize the DRAM ( copyir.com     • Defective BICU board
SC165    Illegal Copy Prevention Error
An abnormality was detected with the ICIB board at power on ( copyir.com     • ICIB connected incorrectly • ICIB defective
SC180    Scanner fan lock The fan motor next to the SIOB did not switch on within 10 sec ( copyir.com  after the CPU issued the ON signal ( copyir.com     • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective
SC181    Scanner Fan Error: Lamp Stabilizer
The exposure lamp regulator fan is not rotating ( copyir.com     • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective

SC182    Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating ( copyir.com     • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective
SC185    CIS communication error Error
caused during ASIC register’s automatic initialization on the CIS, or during transmission between the CIS – DF ( copyir.com     • Harness between the CIS – DF is disconnected • CIS defectiver
SC186    CIS LED error
LED on the CIS caused an error • During initializing, the ratio of the average between leading-edge area and rear-edge is out of range (0 ( copyir.com 7 to 1 ( copyir.com 43) ( copyir.com  • During scanning, the shading data peak is under 32 (8 bit) ( copyir.com     • Harness CN210 and CN220 on ADF are disconnected ( copyir.com  • Replace CIS ( copyir.com
SC187    CIS black level error
The black level scanned by CIS is abnormal ( copyir.com  The black level average of R, G or B is not within range (2 to 62) ( copyir.com  0 < Calibrated Black data level < 255(10bit) ( copyir.com     • Turn off the machine ( copyir.com  • Make sure CN210 and CN220 are connected securely ( copyir.com  • Turn on the machine ( copyir.com
SC188    CIS white level error
The shading data peak detected from the CIS is abnormal ( copyir.com     • CIS defective
SC189    CIS gray balance adjustment error The adjustment error occurs during the test after adjusting the gray balance    • CIS defective
SC195    Machine serial number error
The number registered for the machine serial number does not match ( copyir.com     • Confirm the correct serial number of the machine in the specifications • Important: When SC195 occurs, the serial number must be input ( copyir.com  Please contact your technical supervisor ( copyir.com
SC202    Polygon motor error: ON timeout
The polygon mirror motor does not reach the targeted operating speed within the prescribed time    • Harness to polygon motor drive board disconnected, defective • Polygon motor defective • Polygon motor drive board defective • Polygon motor defective ( copyir.com
SC203    Polygon motor error: OFF timeout
The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off ( copyir.com     • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective • Polygon motor defective ( copyir.com
SC204    Polygon motor error: XSCRDY signal error
The polygon motor stopped operating while the LD unit was firing ( copyir.com     • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective
SC210    Laser beam detection error: K (Black)
The laser synchronization sensor failed to detect the beginning and end of the laser beam flash for the designated color onto the polygon mirror while the mirror is rotating at the prescribed number of revolutions ( copyir.com     • Laser synchronization detector sensor connection loose, not connected • Laser synchronization detector sensor defective • LD unit defective • IPU defective • VBCU defective
SC211    Laser beam detection error: Y (Yellow)
The laser synchronization sensor failed to detect the beginning and end of the laser beam flash for the designated color onto the polygon mirror while the mirror is rotating at the prescribed number of revolutions ( copyir.com     • Laser synchronization detector sensor connection loose, not connected • Laser synchronization detector sensor defective • LD unit defective • IPU defective • VBCU defective
SC212    Laser beam detection error: M (Magenta)
The laser synchronization sensor failed to detect the beginning and end of the laser beam flash for the designated color onto the polygon mirror while the mirror is rotating at the prescribed number of revolutions ( copyir.com     • Laser synchronization detector sensor connection loose, not connected • Laser synchronization detector sensor defective • LD unit defective • IPU defective • VBCU defective
SC213    Laser beam detection error: C (Cyan)
The laser synchronization sensor failed to detect the beginning and end of the laser beam flash for the designated color onto the polygon mirror while the mirror is rotating at the prescribed number of revolutions ( copyir.com     • Laser synchronization detector sensor connection loose, not connected • Laser synchronization detector sensor defective • LD unit defective • IPU defective • VBCU defective
SC220    Laser Synchronization Detector Error: K Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 black, or leading edge, even after the laser diode has been firing for 2 sec ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC221    Laser Synchronization Detector Error: K Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0 ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC222    Laser Synchronization Detector Error: Y Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 yellow, leading edge ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC223    Laser Synchronization Detector Error: Y Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for yellow, leading edge for any LD other than LD0 ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC224    Laser Synchronization Detector Error: M Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 magenta, leading edge ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC225    Laser Synchronization Detector Error: M Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for magenta, leading edge for any LD other than LD0 ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC226    Laser Synchronization Detector Error: C Leading Edge: LD0
While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 cyan, leading edge ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC227    Laser Synchronization Detector Error: C Leading Edge (Not LD0)
While the polygon motor is rotating normally, no synchronizing detection signal is output for cyan, leading edgefor any LD other than LD0 ( copyir.com     • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
SC230    FGATE error: Feedback remains HIGH for K write
After the start of timing to create the black image, the PFGATE register of the GAVD did not assert    • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC231    FGATE error: Feedback remains LOW for K write
After the start of timing to create the black image, the PFGATE register of the GAVD did not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC232    FGATE error: Feedback remains HIGH for Y write
After the start of timing to create the yellow image, the PFGATE register of the GAVD did not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC233    FGATE error: Feedback remains LOW for Y write
After the start of timing to create the yellow image, the PFGATE register of the GAVD did not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC234    FGATE error 1: Feedback remains HIGH for M write
After the start of timing to create the magenta image, the PFGATE register of the GAVD did not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC235    FGATE error: Feedback remains LOW for M write
After the start of timing to create the magenta image, the PFGATE register of the GAVD does not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC236    FGATE error 1: Feedback remains HIGH for C write
After the start of timing to create the cyan image, the PFGATE register of the GAVD did not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC237    FGATE error: Feedback remains LOW for C write
After the start of timing to create the cyan image, the PFGATE register of the GAVD does not assert ( copyir.com     • Harness between the VBCU and LDB unit disconnected, loose, or defective ( copyir.com  • LD unit defective • IPU defective • Controller board disconnected, defective • HDD defective
SC240    LD error: K
An error occurred at the LD error terminal of the K, Y, M, or C LD driver after initialization of the LD because the power to the LD was higher or lower than the prescribed limit ( copyir.com     • LD defective due to wear, damage, short circuit • LDB harness disconnected, loose or defective
SC241    LD error: Y
An error occurred at the LD error terminal of the K, Y, M, or C LD driver after initialization of the LD because the power to the LD was higher or lower than the prescribed limit ( copyir.com     • LD defective due to wear, damage, short circuit • LDB harness disconnected, loose or defective
SC242    LD error: M
An error occurred at the LD error terminal of the K, Y, M, or C LD driver after initialization of the LD because the power to the LD was higher or lower than the prescribed limit ( copyir.com     • LD defective due to wear, damage, short circuit • LDB harness disconnected, loose or defective
SC243    LD error: C
An error occurred at the LD error terminal of the K, Y, M, or C LD driver after initialization of the LD because the power to the LD was higher or lower than the prescribed limit ( copyir.com     • LD defective due to wear, damage, short circuit • LDB harness disconnected, loose or defective
SC268    Optical unit sensor error
At power on, one of the two temperature sensors in the optics unit detected a temperature lower than -10°C ( copyir.com  -or- It detected a temperature higher than 80°C ( copyir.com     • Thermistor disconnected (causes extremely low temperature reading) • Thermistor damaged and short circuited (causes extremely high temperature reading) • VBCU defective
SC270    Skew Control Upper Lower Limit: Y
The pulse total for Yellow skew control is not within the prescribed range ( copyir.com     • ITB not installed correctly ( copyir.com  • ITB defective • Optical unit installed incorrectly • Optical unit defective
SC271    Skew Control Upper Lower Limit: M
The pulse total for Magenta skew control is not within the prescribed range ( copyir.com     • ITB not installed correctly ( copyir.com  • ITB defective • Optical unit installed incorrectly • Optical unit defective
SC272    Skew Control Upper Lower Limit: C
The pulse total for Cyan skew control is not within the prescribed range ( copyir.com     • ITB not installed correctly ( copyir.com  • ITB defective • Optical unit installed incorrectly • Optical unit defective
SC285    MUSIC Continuous Failure
The MUSIC adjustment failed after four attempts ( copyir.com     • Fusing belt installed incorrectly • Fusing belt surface scoured, scratched • MUSIC sensors dirty, defective
SC300    Drum charge corona wire error: K
The output of the charge corona wire of the black PCU is abnormal ( copyir.com     • CGB power pack connection loose, broken defective • Check CGB power pack connection to BCU • CGB power pack defective • BCU defective • Replace OPC drum
SC301    AC charge output error: M
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the AC charge for M, C, Y ( copyir.com     • Disconnect the high voltage cable from Terminal C of the multiple high-voltage supply board ( copyir.com  • Attach a voltmeter to the terminal ( copyir.com  • If there is no output from the terminal, replace the high voltage power supply ( copyir.com  -or- • If there is output from the terminal, test the resistance between the high voltage cable and the ground ( copyir.com  If resistance is nearly “0”, check the high-voltage harness for defects and replace it if necessary ( copyir.com  • Test the conductivity between the OPC unit and the ground ( copyir.com  If there is no conductivity between the OPC unit and ground, replace the OPC unit ( copyir.com  • If there is no charge PWM signal, replace the harness and/or VBCU ( copyir.com
SC302    AC charge output error: C
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the AC charge for M, C, Y ( copyir.com     • Disconnect the high voltage cable from Terminal C of the multiple high-voltage supply board ( copyir.com  • Attach a voltmeter to the terminal ( copyir.com  • If there is no output from the terminal, replace the high voltage power supply ( copyir.com  -or- • If there is output from the terminal, test the resistance between the high voltage cable and the ground ( copyir.com  If resistance is nearly “0”, check the high-voltage harness for defects and replace it if necessary ( copyir.com  • Test the conductivity between the OPC unit and the ground ( copyir.com  If there is no conductivity between the OPC unit and ground, replace the OPC unit ( copyir.com  • If there is no charge PWM signal, replace the harness and/or VBCU ( copyir.com
SC303    AC charge output error: Y
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the AC charge for M, C, Y ( copyir.com     • Disconnect the high voltage cable from Terminal C of the multiple high-voltage supply board ( copyir.com  • Attach a voltmeter to the terminal ( copyir.com  • If there is no output from the terminal, replace the high voltage power supply ( copyir.com  -or- • If there is output from the terminal, test the resistance between the high voltage cable and the ground ( copyir.com  If resistance is nearly “0”, check the high-voltage harness for defects and replace it if necessary ( copyir.com  • Test the conductivity between the OPC unit and the ground ( copyir.com  If there is no conductivity between the OPC unit and ground, replace the OPC unit ( copyir.com  • If there is no charge PWM signal, replace the harness and/or VBCU ( copyir.com
SC304    Charge Corona Error: Charge Leak (K PCU)
A abnormal detection signal (H) was detected for longer than 250 ms ( copyir.com     • Turn the machine power off/on • CGB power pack harness connectors loose, broken, defective • Corona wire caps loose, missing • CGB power pack defective • Charge corona unit connectors loose, broken, defective
SC308    Charge Corona Error: Wire Cleaner Error (K PCU)
The charge corona wire cleaner motor remained locked after the motor was switched on, or failed to switch off within the prescribed time after cleaning started ( copyir.com     • Turn the machine power off/on • Motor overloaded due to a physical obstruction • Motor defective
SC313    Charge, development error: M
After the M, C, or Y drum started to rotate, the feedback for the charge unit of the color dropped below 0 ( copyir.com 3V ( copyir.com     • Make sure that the settings of SP2202 are at the defaults ( copyir.com  • Check harness connections between charge roller and transfer power pack ( copyir.com  • Defective charge roller • Defective power pack
SC314    Charge, development error: C
After the M, C, or Y drum started to rotate, the feedback for the charge unit of the color dropped below 0 ( copyir.com 3V ( copyir.com     • Make sure that the settings of SP2202 are at the defaults ( copyir.com  • Check harness connections between charge roller and transfer power pack ( copyir.com  • Defective charge roller • Defective power pack
SC315    Charge, development error: Y
After the M, C, or Y drum started to rotate, the feedback for the charge unit of the color dropped below 0 ( copyir.com 3V ( copyir.com     • Make sure that the settings of SP2202 are at the defaults ( copyir.com  • Check harness connections between charge roller and transfer power pack ( copyir.com  • Defective charge roller • Defective power pack
SC316    Drum Charge Error: K
Drum charge output voltage (Vpp) exceeded 2 ( copyir.com 8 kV ( copyir.com     • Check the connections of the charge unit of the PCU where the problem occurred ( copyir.com  • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
SC317    Drum Charge Error: M
Drum charge output voltage (Vpp) exceeded 2 ( copyir.com 8 kV ( copyir.com     • Check the connections of the charge unit of the PCU where the problem occurred ( copyir.com  • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
SC318    Drum Charge Error: C
Drum charge output voltage (Vpp) exceeded 2 ( copyir.com 8 kV ( copyir.com     • Check the connections of the charge unit of the PCU where the problem occurred ( copyir.com  • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
SC319    Drum Charge Error: Y
Drum charge output voltage (Vpp) exceeded 2 ( copyir.com 8 kV ( copyir.com     • Check the connections of the charge unit of the PCU where the problem occurred ( copyir.com  • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
SC320    Development power pack error: K
This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y ( copyir.com     • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
SC321    Development power pack error: M
This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y ( copyir.com     • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
SC322    Development power pack error: C
This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y ( copyir.com     • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
SC323    Development power pack error: Y
This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y ( copyir.com     • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
SC324    Development motor error: K
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor ( copyir.com     • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
SC325    Development motor error: M
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor ( copyir.com     • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
SC326    Development motor error: C
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor ( copyir.com     • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
SC327    Development motor error: Y
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor ( copyir.com     • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective
SC336    Developer set error: K
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized ( copyir.com     1 ( copyir.com  Open the front door ( copyir.com  2 ( copyir.com  Pull out the film seal from the black, magenta, cyan, or yellow developer bottle ( copyir.com  3 ( copyir.com  Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K ( copyir.com  • SP3801 004 to initialize the TD sensor for M ( copyir.com  • SP3801 005 to initialize the TD sensor for C ( copyir.com  • SP3801 006 to initialize the TD sensor for Y
SC337    Developer set error: M
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized ( copyir.com     1 ( copyir.com  Open the front door ( copyir.com  2 ( copyir.com  Pull out the film seal from the black, magenta, cyan, or yellow developer bottle ( copyir.com  3 ( copyir.com  Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K ( copyir.com  • SP3801 004 to initialize the TD sensor for M ( copyir.com  • SP3801 005 to initialize the TD sensor for C ( copyir.com  • SP3801 006 to initialize the TD sensor for Y
SC338    Developer set error: C
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized ( copyir.com     1 ( copyir.com  Open the front door ( copyir.com  2 ( copyir.com  Pull out the film seal from the black, magenta, cyan, or yellow developer bottle ( copyir.com  3 ( copyir.com  Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K ( copyir.com  • SP3801 004 to initialize the TD sensor for M ( copyir.com  • SP3801 005 to initialize the TD sensor for C ( copyir.com  • SP3801 006 to initialize the TD sensor for Y
SC339    Developer set error: Y
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized ( copyir.com     1 ( copyir.com  Open the front door ( copyir.com  2 ( copyir.com  Pull out the film seal from the black, magenta, cyan, or yellow developer bottle ( copyir.com  3 ( copyir.com  Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K ( copyir.com  • SP3801 004 to initialize the TD sensor for M ( copyir.com  • SP3801 005 to initialize the TD sensor for C ( copyir.com  • SP3801 006 to initialize the TD sensor for Y
SC348    Toner supply motor error
2 sec ( copyir.com  after the motor START signal is output, a LOCK signal cannot be detected ( copyir.com     • Motor harness disconnected, loose, or defective • Toner pump overload • Sub hopper overload • Toner hopper motor defective
SC350    Developer Fill Error: K
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed ( copyir.com     • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see “Handling Problems with Developer Filling” under “PCU” in Section 3 ( copyir.com
SC351    Developer Fill Error: M
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed ( copyir.com     • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see “Handling Problems with Developer Filling” under “PCU” in Section 3 ( copyir.com
SC352    Developer Fill Error: C
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed ( copyir.com     • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see “Handling Problems with Developer Filling” under “PCU” in Section 3 ( copyir.com
SC353    Developer Fill Error: Y
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed ( copyir.com     • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see “Handling Problems with Developer Filling” under “PCU” in Section 3 ( copyir.com
SC356    Toner Supply Error 1: K
The machine detected 10 times that the amount of toner applied to create the black ID sensor pattern on the drum between sheets (SP3101-1 ID Pattern Display – Applied K) was less than the minimum threshold setting (0 ( copyir.com 0 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-1 Tnr Supply Time – Sub Hopper CL: K) exceeded the threshold of 65K ms ( copyir.com     • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
SC357    Toner Supply Error 2: M
The machine detected 10 times that the amount of toner applied to create the magenta ID sensor pattern on the drum between sheets (SP3101-2 ID Pattern Display – Applied M) was less than the minimum threshold setting (0 ( copyir.com 0 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-2 Tnr Supply Time – Sub Hopper CL: M) exceeded the threshold of 65K ms ( copyir.com     • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
SC358    Toner Supply Error 3: C The machine detected 10 times that the amount of toner applied to create the cyan ID sensor pattern on the drum between sheets (SP3101-3 ID Pattern Display – Applied C) was less than the minimum threshold setting (0 ( copyir.com 0 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-3 Tnr Supply Time – Sub Hopper CL: C) exceeded the threshold of 65K ms ( copyir.com     • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
SC359    Toner Supply Error 4: Y
The machine detected 10 times that the amount of toner applied to create the yellow ID sensor pattern on the drum between sheets (SP3101-4 ID Pattern Display – Applied Y) was less than the minimum threshold setting (0 ( copyir.com 0 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-4 Tnr Supply Time – Sub Hopper CL: Y) exceeded the threshold of 65K ms ( copyir.com     • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
SC360    TD sensor (Vt high) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0 ( copyir.com 5V for 10 counts ( copyir.com     • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC361    TD sensor (Vt high) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0 ( copyir.com 5V for 10 counts ( copyir.com     • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC362    TD sensor (Vt high) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0 ( copyir.com 5V for 10 counts ( copyir.com     • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC363    TD sensor (Vt high) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0 ( copyir.com 5V for 10 counts ( copyir.com     • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC364    TD sensor (Vt low) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0 ( copyir.com 5V for 10 counts ( copyir.com     • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC365    TD sensor (Vt low) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0 ( copyir.com 5V for 10 counts ( copyir.com     • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC366    TD sensor (Vt low) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0 ( copyir.com 5V for 10 counts ( copyir.com     • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC367    TD sensor (Vt low) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0 ( copyir.com 5V for 10 counts ( copyir.com     • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC372    TD sensor adjustment error: K
During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2 ( copyir.com 5+-0 ( copyir.com 2V    TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC373    TD sensor adjustment error: M
During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2 ( copyir.com 5+-0 ( copyir.com 2V    TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC374    TD sensor adjustment error: C
During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2 ( copyir.com 5+-0 ( copyir.com 2V    TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC375    TD sensor adjustment error: Y
During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2 ( copyir.com 5+-0 ( copyir.com 2V    TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently ( copyir.com  The PCU must be replaced if the TD sensor is defective ( copyir.com
SC396    Drum motor error: K
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft ( copyir.com  The motor has no traction (due to a bent cleaning blade, for example) ( copyir.com     • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
SC397    Drum motor error: M
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft ( copyir.com  The motor has no traction (due to a bent cleaning blade, for example) ( copyir.com     • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
SC398    Drum motor error: C
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft ( copyir.com  The motor has no traction (due to a bent cleaning blade, for example) ( copyir.com     • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
SC399    Drum motor error: Y
The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft ( copyir.com  The motor has no traction (due to a bent cleaning blade, for example) ( copyir.com     • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective
SC400    ID sensor error: Calibration
Before adjustment Vsg_reg<0 ( copyir.com 5 but Vsg_reg could not be adjusted to the target Vsg_reg = 4 ( copyir.com 0+-0 ( copyir.com 2V during process control ( copyir.com     • ID sensor harness disconnected, loose, defective • ID sensor dirty • ID sensor defective • ITB unit drawer connector dirty
SC402    ID Sensor Pattern Maximum Coverage Error 1: K
The amount of toner applied to create the black ID sensor pattern between sheets (SP3101-1 ID Pattern Display – Applied: K) exceeded the maximum threshold of 0 ( copyir.com 3 mg/cm2 due to an over supply of black toner ( copyir.com     K toner supply unit defective
SC403    ID Sensor Pattern Maximum Coverage Error 2: M
The amount of toner applied to create the magenta ID sensor pattern between sheets (SP3101-2 ID Pattern Display – Applied: M) exceeded the maximum threshold of 0 ( copyir.com 7 mg/cm2 due to an over supply of magenta toner ( copyir.com     • Magenta toner supply unit defective
SC404    ID Sensor Pattern Maximum Coverage Error 3: C
The amount of toner applied to create the cyan ID sensor pattern between sheets (SP3101-3 ID Pattern Display – Applied: C) exceeded the maximum threshold of 0 ( copyir.com 7 mg/cm2 due to an over supply of cyan toner ( copyir.com     • Cyan toner supply unit defective
SC405    ID Sensor Pattern Maximum Coverage Error 4: Y
The amount of toner applied to create the yellow ID sensor pattern between sheets (SP3101-4 ID Pattern Display – Applied: Y) exceeded the maximum threshold of 0 ( copyir.com 7 mg/cm2 due to an over supply of yellow toner ( copyir.com     • Yellow toner supply unit defective
SC406    ID Sensor Pattern Minimum Coverage Error 1: K
The machine detected 10 times that the amount of toner applied to create the black ID sensor pattern on the drum between sheets (SP3101-1 ID Pattern Display – Applied K) was less than the minimum threshold setting (0 ( copyir.com 0 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-1 Tnr Supply Time – Sub Hopper CL: K) was less than or equal to the threshold of 65K ms ( copyir.com     • Toner shield glass dirty • Development unit defective • Image transfer unit defective
SC407    ID Sensor Pattern Minimum Coverage Error 2: M
The machine detected 10 times that the amount of toner applied to create the magenta ID sensor pattern on the drum between sheets (SP3101-2 ID Pattern Display – Applied M) was less than the minimum threshold setting (0 ( copyir.com 2 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-2 Tnr Supply Time – Sub Hopper CL: M) was less than or equal to the threshold of 65K ms ( copyir.com     • Toner shield glass dirty • Development unit defective • Image transfer unit defective
SC408    ID Sensor Pattern Minimum Coverage Error 3: C
The machine detected 10 times that the amount of toner applied to create the cyan ID sensor pattern on the drum between sheets (SP3101-3 ID Pattern Display – Applied C) was less than the minimum threshold setting (0 ( copyir.com 2 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-3 Tnr Supply Time – Sub Hopper CL: C) was less than or equal to the threshold of 65K ms ( copyir.com     • Toner shield glass dirty • Development unit defective • Image transfer unit defective
SC409    ID Sensor Pattern Minimum Coverage Error 4: Y
The machine detected 10 times that the amount of toner applied to create the yellow ID sensor pattern on the drum between sheets (SP3101-4 ID Pattern Display – Applied Y) was less than the minimum threshold setting (0 ( copyir.com 2 mg/cm2) ( copyir.com  Also, the total time for the operation of the sub hopper clutch (SP3251-4 Tnr Supply Time – Sub Hopper CL: Y) was less than or equal to the threshold of 65K ms ( copyir.com     • Toner shield glass dirty • Development unit defective • Image transfer unit defective
SC410    ID sensor error: Development K
Development gamma for black, magenta, cyan, or yellow is not within range (0 ( copyir.com 3 to 6 ( copyir.com 0) ( copyir.com  Process control halts when this SC is issued ( copyir.com     • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
SC411    ID sensor error: Development M
Development gamma for black, magenta, cyan, or yellow is not within range (0 ( copyir.com 3 to 6 ( copyir.com 0) ( copyir.com  Process control halts when this SC is issued ( copyir.com     • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
SC412    ID sensor error: Development C
Development gamma for black, magenta, cyan, or yellow is not within range (0 ( copyir.com 3 to 6 ( copyir.com 0) ( copyir.com  Process control halts when this SC is issued ( copyir.com     • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
SC413    ID sensor error: Development Y
Development gamma for black, magenta, cyan, or yellow is not within range (0 ( copyir.com 3 to 6 ( copyir.com 0) ( copyir.com  Process control halts when this SC is issued ( copyir.com     • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • LD sensor harness loose, broken, defective • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective)
SC414    ID sensor error: Development start voltage K
The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)    • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
SC415    ID sensor error: Development start voltage M
The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)    • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
SC416    ID sensor error: Development start voltage C
The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)    • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
SC417    ID sensor error: Development start voltage Y
The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)    • Toner density abnormal ( copyir.com  Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61) ( copyir.com  • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
SC418    LED error during Vsg adjustment
PWM value: Ifsg>3000 This means the current to the LED of the ID sensor is abnormal ( copyir.com     • ID sensor dirty • ID sensor defective
SC420    Potential sensor error: Vd Adjustment K
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V) ( copyir.com     • Drum potential sensor harness, connector is loose, broken, defective • Drum potential sensor dirty • Drum potential sensor defective • Drum connector, harness loose, broken, defective • Development power pack defective • VBCU defective
SC421    Potential sensor error: Vd Adjustment K
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V) ( copyir.com     • Drum potential sensor harness, connector is loose, broken, defective • Drum potential sensor dirty • Drum potential sensor defective • Drum connector, harness loose, broken, defective • Development power pack defective • VBCU defective
SC422    Potential sensor error: Vd Adjustment M
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V) ( copyir.com     • Drum potential sensor harness, connector is loose, broken, defective • Drum potential sensor dirty • Drum potential sensor defective • Drum connector, harness loose, broken, defective • Development power pack defective • VBCU defective
SC423    Potential sensor error: Vd Adjustment C
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V) ( copyir.com     • Drum potential sensor harness, connector is loose, broken, defective • Drum potential sensor dirty • Drum potential sensor defective • Drum connector, harness loose, broken, defective • Development power pack defective • VBCU defective
SC423    Potential sensor error: Vd Adjustment Y
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V) ( copyir.com     • Drum potential sensor harness, connector is loose, broken, defective • Drum potential sensor dirty • Drum potential sensor defective • Drum connector, harness loose, broken, defective • Development power pack defective • VBCU defective
SC424    Potential sensor error 5: Vl adjustment K
Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns ( copyir.com     • Drum worn • LD unit dirty • Poor drum ground connection
SC425    Potential sensor error 6: Vl adjustment M
Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns ( copyir.com     • Drum worn • LD unit dirty • Poor drum ground connection
SC426    Potential sensor error 7: Vl adjustment C
Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns ( copyir.com     • Drum worn • LD unit dirty • Poor drum ground connection
SC427    Potential sensor error 8: Vl adjustment Y
Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns ( copyir.com     • Drum worn • LD unit dirty • Poor drum ground connection
SC432    Potential sensor error 1: Vr K
Vr > 200V ( copyir.com  The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V ( copyir.com     • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC433    Potential sensor error 2: Vr M
Vr > 200V ( copyir.com  The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V ( copyir.com     • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC434    Potential sensor error 3: Vr C
Vr > 200V ( copyir.com  The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V ( copyir.com     • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC435    Potential sensor error 4: Vr Y
Vr > 200V ( copyir.com  The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V ( copyir.com     • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC436    Potential sensor error: Vd K
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -800)    • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC437    Potential sensor error: Vd M
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -800)    • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC438    Potential sensor error: Vd C
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -800)    • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC439    Potential sensor error: Vd Y
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -800)    • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
SC440    Image transfer power pack error: K
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the power pack for K, M, C, or Y ( copyir.com     • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged
SC441    Image transfer power pack error: M
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the power pack for K, M, C, or Y ( copyir.com     • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged
SC442    Image transfer power pack error: C
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the power pack for K, M, C, or Y ( copyir.com     • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged
SC443    Image transfer power pack error: Y
An interrupt checks the status of the power pack every 10 ms ( copyir.com  This SC is issued if the VBCU detects a short in the power pack for K, M, C, or Y ( copyir.com     • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged
SC445    Image transfer motor error
The control board of the ITB motor belt generated signals that indicate there is problem with the image transfer belt motor ( copyir.com     • ITB motor defective • ITB control board defective • ITB overloaded • Encoder strip on the edge of the ITB damaged ( copyir.com
SC446    ITB lift motor error
The state of the ITB lift sensor does not change its state (switching from off to on or vice versa), even after the ITB lift motor starts rotating ( copyir.com     • ITB lift sensor dirty, disconnected, defective • ITB lift motor disconnected, defective • ITB sensor defective • ITB lift motor defective
SC447    Image transfer roller position error
The machine checks for the presence of the K STC and the checks the status of the K image transfer roller lift sensor after the door is closed ( copyir.com     • Transfer belt release lever down • Lift sensor connector loose, broken, dirty • Lift sensor defective
SC450    Transfer power pack output error
An interrupt checks the status of the power pack every 2 ms ( copyir.com  This SC is issued if the VBCU detects a short in the power pack 250 times at T2 within 500 ms ( copyir.com     • Damaged insulation on the high-voltage supply cable • Damaged insulation around the highvoltage power supply ( copyir.com  • Check SIOB harness connections • SIOB defective
SC452    PTR lift mechanism error
The PTR was not detected at the home position within 2 sec ( copyir.com  after the PTR lift motor turned on ( copyir.com     • PTR HP sensor dirty, disconnected, defective • PTR lift motor disconnected, defective
SC455    PTR motor error
The lock signal from the paper transfer motor was not detected within 1 sec ( copyir.com  after the motor switched on ( copyir.com     • Motor disconnected • PTR shaft locked, needs cleaning, blocked by obstruction • Drive shaft of the ITB locked and overloaded, needs cleaning, or blocked by obstruction • DRB disconnected, defective
SC460    Separation power pack output error
This SC is issued if the VBCU detects a short in the transfer power pack ( copyir.com     • Damaged insulation on the high-voltage supply cable (replace cable) • Damaged insulation around the transfer power pack
SC465    Image Transfer Roller End: K
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life ( copyir.com     • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
SC466    Image Transfer Roller End: M
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life ( copyir.com     • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
SC467    Image Transfer Roller End: C
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life ( copyir.com     • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
SC468    Image Transfer Roller End: Y
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life ( copyir.com     • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
SC472    ITB Bias Roller End
The machine detected an abnormal reading of the resistance of the ITB bias roller because it is near the end of its service life ( copyir.com     • Check the connections between the transfer power pack • Replace image transfer roller • Transfer power pack defective
SC480    Drum cleaning motor error: K
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time ( copyir.com     • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective
SC481    Drum cleaning motor error: M
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time ( copyir.com     • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective
SC482    Drum cleaning motor error: C
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time ( copyir.com     • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective
SC483    Drum cleaning motor error: Y
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time ( copyir.com     • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective
SC484    Used toner bottle full
The toner full sensor has detected that the used toner bottle is full ( copyir.com     • Remove the used toner bottle • Empty the used toner bottle and reinstall it
SC485    Used toner bottle motor error
The lock signal of the used toner bottle motor remains HIGH for more than 600 ms ( copyir.com     • Used toner bottle harness loose, broken, defective • Used toner bottle motor defective
SC487    Used toner bottle set error
The set sensor of the used toner bottle remains LOW for more than 500 ms ( copyir.com  (The sensor goes HIGH when the bottle is installed correctly ( copyir.com )    • Used toner bottle not installed • Remove used toner bottle and reinstall correctly
SC488    Used toner transport lock
Used toner cannot be transported to the used toner bottle ( copyir.com     • Blockage in the line to the used toner bottle
SC490    MUSIC sensor error
One or more of the MUSIC sensors is not functioning normally ( copyir.com     • MUSIC sensor harness loose, broken, defective • Sensor defective
SC495    ITB encoder sensor error
The ITB encoder sensor that reads the encoded strip on the ITB is not functioning properly ( copyir.com     • Sensor dirty • Sensor harness loose, broken, defective • Sensor out of position because installed incorrectly • ITB installed incorrectly
SC496    MUSIC sensor error
The MUSIC sensor detected an abnormal pattern on the ITB because: • ADC exceeded upper or lower limit ( copyir.com  • The pattern used to calculate the amount of skew is abnormal ( copyir.com  • The reading of the pattern exceeded the length of time the LED projected light ( copyir.com  • LED light could not be adjusted correctly ( copyir.com     • ITB installed incorrectly • Inspect ITB belt for damage, replace • MUSIC pattern abnormal; do a forced process control (SP3821) and check the result ( copyir.com  • MUSIC sensor defective or disconnected
SC497    Temperature and humidity sensor error: M PCU
The thermistor output of the temperature and humidity sensor above the M PCU was not within the prescribed range (0 ( copyir.com 5V to 4 ( copyir.com 2V)    • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
SC498    Temperature and humidity sensor error: Toner Bottle
The thermistor output of the temperature and humidity sensor below the used toner bottle was not within the prescribed range (0 ( copyir.com 5V to 4 ( copyir.com 2V)    • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
SC499    ITB encoder sensor error The ITB sensor that reads the encoded film strip on the edge of the image transfer belt is sending is operating correctly ( copyir.com     • ITB encoder sensor dirty • Sensor harness disconnected or damaged • Encoded scale on the edge of the ITB is damaged or dirty • ITB installed incorrectly
SC501    Tray 1 (tandem tray) feed error (Japan Only)
The tray 1 lift sensor does not switch on 10 s after the tray lift motor switches on and starts lifting the bottom plate ( copyir.com  When the tray lowers, the tray lift sensor does not go off within 1 ( copyir.com 5 sec ( copyir.com  The lower limit sensor of the tandem tray does not detect the lower limit within 10 sec ( copyir.com     • Tray lift motor harness disconnected, loose, defective • Paper or other obstacle trapped between tray and motor • Tray lift sensor disconnected, damaged • Lower limit sensor disconnected, damaged • Pick-up solenoid disconnected, blocked by an obstacle
SC502    Tray 2 (paper cassette) feed error (Japan Only)
The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate ( copyir.com  When the tray lowers, the tray lift sensor does not go off within 1 ( copyir.com 5 sec ( copyir.com  The lower limit sensor of the tandem tray does not detect the lower limit within 10 sec ( copyir.com     • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle
SC503    Tray 1 feed error
The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate ( copyir.com  When the tray lowers, the tray lift sensor does not go off within 1 ( copyir.com 5 sec ( copyir.com     • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle
SC504    Tray 2 feed error
The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate ( copyir.com  When the tray lowers, the tray lift sensor does not go off within 1 ( copyir.com 5 sec ( copyir.com     • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle
SC505    Tandem tray rear fence motor error
The return sensor does not switch on within 10 sec ( copyir.com  after the rear fence motor switches on ( copyir.com  The HP sensor does not switch on 10 sec ( copyir.com  after the rear fence motor switches on ( copyir.com  The HP sensor and return sensor switch on at the same time ( copyir.com     • Rear fence motor defective or poor connection • Paper or other obstacle interfering with operation of the sensors • Paper or other obstacle trapped between tray and motor • Motor mechanical overload due to obstruction • Return sensor or HP sensor defective or dirty
SC510    LCT tray error: B473/D350
When the bottom plate is lifted, the upper limit sensor does not come on for 30 sec ( copyir.com  When the bottom plate is lowered, the lower limit sensor does not come on for 30 sec ( copyir.com  After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on ( copyir.com  The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2 ( copyir.com 5 s, and a message prompts user to reset paper ( copyir.com     • Tray lift motor harness, disconnected, loose, or defective • Tray lift motor defective • Lift sensor defective or disconnected • Pick-up solenoid defective or disconnected • Paper end sensor defective
SC515    Duplex jogger motor error 1
When the jogger fence moves to the home position, the jogger fence HP sensor does not switch on even after the jogger motor has moved the jogger fence 153 ( copyir.com 5 mm ( copyir.com     • Jogger fence motor defective or poor connection • Paper or other obstacle interfering with operation of the sensors or motor • Return sensor or HP sensor defective, dirty, or disconnected • Paper or other obstacle has jammed mechanism • HP sensor connector disconnected or defective • HP sensor defective
SC516    Duplex jogger motor error 2
When the jogger fence moves from the home position, the jogger fence HP sensor does not turn off even if the jogger motor has moved the jogger fence 153 ( copyir.com 5 mm ( copyir.com     • Jogger fence motor defective or poor connection • Paper or other obstacle interfering with operation of the sensors or motor • Return sensor or HP sensor defective, dirty, or disconnected • Paper or other obstacle has jammed mechanism • HP sensor connector disconnected or defective • HP sensor defective
SC517    LCIT air assist front fan error
The front air assist fan is not functioning properly ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged, defective
SC518    LCIT air assist rear fan error
The rear air assist fan is not functioning properly ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged, defective
SC530    Fusing cooling fan error
The VBCU did not receive the lock signal 5 seconds after the fusing unit fan switches on ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC531    Fusing Fan Error: Front
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan at the front of the fusing unit near the heat dissipation fins was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC532    Controller fan error
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan that cools the printed circuit boards was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC533    Fusing unit suction fan error
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan that draws air out of the fusing unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC533-1    Fusing exit fan error
The machine detected a fan lock signal 5 times at 1 sec ( copyir.com  intervals ( copyir.com  This indicates that the fan is not operating and the machine stops ( copyir.com     • Fan connection loose, broken, defective • Fan is blocked by an obstruction • Fan motor is defective
SC534    Duplex unit fan error
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan that draws air out of the duplex unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC535    Development Intake Fan Error
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan in the Y development unit was operating    • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC536    Development Intake Fan Error: Y
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan in the development unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC537    Development Intake Fan Error: C
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan in the development unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC538    Development Intake Fan Error: M
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan in the development unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC539    Development Intake Fan Error: K
The lock signal remained HIGH for 5 sec ( copyir.com  while the fan in the development unit was operating ( copyir.com     • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
SC540    Fusing/exit motor error
Motor operation was detected abnormal at power on ( copyir.com     • Check inside the fusing unit for any obstructions • Motor harness loose, broken, defective • Motor or its driver board defective
SC541    Heating roller thermistor (center) error 1
The “floating” (non-contact) thermistor at the center of the heating roller is not operating correction ( copyir.com     • Thermistor harness connection loose, disconnected, defective • Thermistor installed incorrectly • Thermistor defective
SC543    Heating roller thermistor (center) error 2
The thermistor at the center of the heating roller detected an abnormally high temperature (over 250°C)    • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC544    Heating roller thermistor (center) error 3
The thermistor detected a temperature over 260°C ( copyir.com  ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC545    Lamp remains on
After hot roller reaches warm-up temperature, the center fusing lamps in the heating roller remained on at full capacity after reaching the warm-up temperature while the hot roller was not rotating ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • Heating roller thermistor damaged, or out of position • Fusing lamp disconnected, broken
SC546    Heating roller thermistor error (side)
The temperature measured by the heating roller thermistor does not reach 0°C after 50 sec ( copyir.com  and remains over this temperature for 10 readings ( copyir.com     • Loose connection of the heating roller thermistor • Defective heating roller thermistor
SC547    Zero cross error
When the main switch is turned on, the machine checks how many zero-cross signals are generated within 500 ms ( copyir.com  This SC code is issued if the number of zero-cross signals detected is not within specification ( copyir.com  Note: Zero cross signals, generated from an ac power supply, are used to generate a trigger pulses to control the applied power accurately ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • Electrical noise on the power supply line • Fusing relay damaged, replace the AC drive board ( copyir.com
SC549    Heating roller thermistor (center): software error
The thermistor detected a temperature over 250°C 10 times within 1 sec ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC550    Heating roller thermistor 3 (side): hardware error
The thermistor detected a temperature over 260°C ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC551    Pressure roller thermistor error 1
The temperature measured by the pressure roller thermistor did not reach 0°C after 10 attempts ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • Loose connection of the pressure roller thermistor • Thermistor positioned incorrectly • Defective pressure roller thermistor
SC552    Pressure roller thermistor error 2
After the main switch is turned on or the cover is closed, the heating roller temperature did not reach the ready temperature (45°C) within 80 sec ( copyir.com  after the fusing lamp switches on ( copyir.com  -or- If the fusing unit did not reach the reload temperature after 350 sec ( copyir.com     • Pressure roller thermistor harness loose, disconnected, defective • Pressure roller thermistor defectives ( copyir.com
SC553    Pressure roller thermistor (software) error
The thermistor detected a temperature over 220°C 12 times within 1 sec ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC554    Pressure roller thermistor (hardware) error
The thermistor detected a temperature over 230°C ( copyir.com     • Do SP5810 to cancel the SC fusing code • TRIAC short, AC drive board defective • VBCU defective
SC555    Pressure roller fusing lamp remains on
After hot roller reaches warm-up temperature, the pressure roller fusing lamp remained for 300 sec ( copyir.com  while the hot roller is not rotating ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
SC556    Heating roller fusing lamp error
After hot roller reaches warmup temperature, the heating roller fusing lamp (ends) remains for 10 sec ( copyir.com  while the hot roller is not rotating ( copyir.com     • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
SC557    Zero Cross Over Error
At power on the fusing relay was detected as defective ( copyir.com     • Replace the AC drive board ( copyir.com
SC559    Three Successive Paper Jams in Fusing Unit
This SC only occurs if SP1159 is on, and a jam occurred in the fusing unit for three consecutive sheets of paper ( copyir.com  With SP1159 set to “1” the machine operation can be restored only by the service technician ( copyir.com  The paper cooling job time sensor detected paper late for 3 counts ( copyir.com     • Remove the paper that is jammed in the fusing unit ( copyir.com  • Make sure that the fusing unit is clean and has no obstacles in the paper feed path ( copyir.com
SC561    Heating roller non-contact thermistor error 1
The temperature measured by the heating roller thermistor (non-contact) on the end of the heating roller did not reach the prescribed warm-up temperature within 1 sec ( copyir.com     • Loose, broken, damaged connector • Defective thermistor
SC562    Heating roller non-contact thermistor error 2
After the main switch is turned on or the cover is closed, the heating roller temperature does not reach the ready temperature within 100 sec ( copyir.com  after the heater switches on ( copyir.com  -or- The heating roller did not reach the ready temperature within 150 sec ( copyir.com     • Do SP5810 to cancel the SC fusing code • Defective hot roller thermistor • Heating roller disconnected, defective
SC563    Heating roller non-contact thermistor error 3
The thermistor 2 (of the heating roller) detected a temperature over 250°C 10 times within 1 sec ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC564    Heating roller non-contact thermistor error 3
The thermistor detected a temperature over 260°C ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • TRIAC short, AC drive board defective • VBCU defective
SC565    Heating roller fusing lamp on error
After fusing belt reached warm-up temperature, the heating roller fusing lamp remained on for 20 sec ( copyir.com  while the hot roller was not rotating ( copyir.com     • Do SP5810 to cancel the SC fusing code ( copyir.com  • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
SC566    Heating roller non-contact thermistor 3
Thermistor detected a temperature less than 0 degrees more than three times ( copyir.com     • Do SP5810 to cancel the error ( copyir.com  • Hot roller thermistor connector disconnected, loose, broken, or defective ( copyir.com
SC569    Pressure roller lift error 2
Pressure roller lift motor not operating correctly ( copyir.com  (No signal to indicate completion of operation ( copyir.com )    • Pressure roller lift sensor connection loose, broken, damaged • Clean the pressure roller lift sensor • Pressure roller lift harness loose, broken, damage • Pressure roller lift motor blocked by an obstruction • Pressure roller lift motor defective
SC570    Development intake fan error
Fan motor not operating correctly ( copyir.com     • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective
SC571    Ozone exhaust fan (FC) error
The fan of the middle ozone filter box not operating correctly ( copyir.com     • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective
SC572    Ozone exhaust fan (K) error
The fan of the lower ozone filter box not operating correctly ( copyir.com     • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective
SC573    Ozone intake fan error
The ozone filter intake fan not operating correctly ( copyir.com     • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective
SC574    Y thermistor error The thermistor near the Y PCU has short circuited or otherwise not operating correctly ( copyir.com     • Harness loose, broken, defective • Thermistor defective
SC585    Double-feed detection sensor error
The ADC output value of the double-feed sensor LED was not within range (2 to 250) ( copyir.com     • Sensors are covered with paper dust or other matter and require cleaning • Sensor harness connection loose, broken, defective • There is an obstruction between the emitter/receptor sensor pair ( copyir.com  • Sensors defective
SC599    Tray 1 lift motor error
An error was detected in the operation of the lift motor for Tray 1 (tandem tray) ( copyir.com     • Motor harness loose, broken, defective • Motor overload due to an obstruction • Motor defective
SC620    ARDF communication error
A BREAK signal occurs after the machine detects the ARDF, or a communication timeout occurs ( copyir.com     • ARDF disconnected • VBCU board harness disconnected, defective • VBCU board defective • Spurious noise from the power supply line • ARDF defective
SC621    Mailbox-to-Finisher communication error
Communication between the mailbox and finisher is interrupted ( copyir.com  An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed ( copyir.com     • Connection cable between mailbox and finisher disconnected, defective • Finisher main board defective • VBCU defective • PSU defective
SC622    PFB communication error
Communication between the VBCU and PFB was interrupted ( copyir.com  (Communication status is monitored at 30 ms intervals ( copyir.com )    • Connection cable between the VBCU and PFB is disconnected, defective • VBCU defective • PFB defective
SC624    Mailbox-to-copier communication error
Communication between the mailbox and copier is interrupted ( copyir.com  An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed ( copyir.com     • Mailbox cable disconnected, defective • Mailbox main board defective • VBCU defective • PSU defective
SC625    VBCU-DTMB (DMC1) communication error
Communication between the VBCU and DMC (main) was interrupted ( copyir.com  An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed ( copyir.com     • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • PSU defective • VBCU defective • 5V power supply defective
SC626    VBCU-DTMB (DMC2) communication error
Communication between the VBCU and DMC (sub) was interrupted ( copyir.com  An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed ( copyir.com     • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • VBCU defective • PSU defective
SC627    VBCU-DTMB (TMC) communication error
Communication between the VBCU and TMC was interrupted ( copyir.com  An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed ( copyir.com     • DTMB harness loose, broken, defective • DTMB defective • VBCU defective • PSU defective
SC636    SD card error    • There is no expanded authentication module in the machine ( copyir.com  • The SD card is damaged or the authentication module is corrupted ( copyir.com  • There is no DESS module in the machine ( copyir.com
SC641    Engine-Controller Communication Error: No Response
There was no response to a frame sent from the controller board to the engine ( copyir.com     • Cycle the machine off/on ( copyir.com
SC670    Engine start failure
The engine did not respond within 30s after power on, or the engine went down suddenly at power on or during warm up because a communication reset occurred between the VBCU and the controller ( copyir.com     • VBCU installed incorrectly • VBCU defective
SC671    Incorrect board detected
An illegal engine board was detected at power on ( copyir.com     • Replace BICU
SC687    Memory address command error
The VBCU does not receive a memory address command from the controller 120 seconds after paper is in the position for registration ( copyir.com     • Turn the machine power off/on • Check the controller board connections • Controller defective
SC701    ARDF original pickup operation error
Even though the pickup motor is rotating clock-wise, the pickup roller home position sensor cannot detect the position of the pickup roller ( copyir.com     • Pickup roller HP sensor harness loose, disconnected, defective • Pickup roller HP sensor defective • Pickup motor harness loose, disconnected, defective • Pickup motor defective • ARDF control board defective
SC705    ARDF bottom plate lift motor
The bottom plate HP sensor did not detect the home position of the bottom plate after the bottom plate lift motor switches on and lowers the bottom plate ( copyir.com  The bottom plate position sensor does not detect the position of the plate after the lift motor switches on and raises the bottom plate ( copyir.com     • ARDF feed motor disconnected, defective • Bottom plate HP sensor disconnected, defective • ARDF main board defective
SC720    Finisher lower transport motor error
No encoder pulse signal is detected for the transport motor within the prescribed time ( copyir.com  The 1st failure causes an original jam message, and the 2nd failure causes this SC code ( copyir.com     • Lower transport motor disconnected, defective • Finisher connection to transport motor loose, defective • Lower transport motor defective • Finisher main board defective
SC721    Finisher jogger motor error (D373/D374, B830)
The jogger fences move out of the home position but the HP sensor output does not change within the specified number of pulses ( copyir.com  The 1st failure causes an original jam message, and the 2nd failure causes this SC code ( copyir.com     • Jogger HP sensor disconnected, defective • Jogger motor disconnected, defective • Jogger motor overloaded due to obstruction • Finisher main board and jogger motor connection loose, defective • Finisher main board defective
SC723    Finisher feed-out motor (B830)
The stack feed-out belt HP sensor does not activate within the specified time after the stack feedout belt motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Stack feed-out HP sensor disconnected, defective • Feed-out motor disconnected, defective • Finisher main board connection to feed out motor disconnected, defective • Motor overload due to obstruction
SC724    Finisher stapler hammer motor error (B830)
Stapling does not finish within the prescribed time after the staple hammer motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Stapler hammer motor overloaded due to obstruction, jammed staple, number of sheets exceeds limit for stapling • Stapler hammer motor disconnected, defective • Staple hammer motor HP sensor disconnected, defective
SC725    Finisher exit guide plate motor error (D373/D374, B830, B660)
After moving away from the guide plate position sensor, the exit guide is not detected at the home position within the prescribed time ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Guide plate motor disconnected, defective • Guide plate motor overloaded due to obstruction • Guide plate position sensor disconnected, defective
SC726    Shift jogger motor 1 error (D373/D374, B830)
The sides fences do not retract within the prescribed time after the shift jogger motor switches on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code    • Shift jogger motor disconnected, defective • Shift jogger motor overloaded due to obstruction • Shift jogger HP sensor disconnected, defective
SC727    Shift jogger motor 2 error (D373/D374)
The side fences do not retract within the prescribed time after the shift jogger motor switches on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Motor harness disconnected, loose, defective • Motor defective • Motor overload • HP defective
SC728    Shift jogger retraction motor error (D373/D374)
The side fences do not retract within the prescribed time after the retraction motor switches on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Motor harness disconnected, loose, defective • Motor defective • Motor overload • HP defective
SC730    Finisher Tray 1 shift motor error (B830)
The shift roller HP sensor of the upper tray does not activate within the prescribed time after the shift tray starts to move toward or away from the home position ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Shift tray HP sensor of the upper tray disconnected, defective • Shift tray motor of the upper tray is disconnected, defective • Shift tray motor of the upper tray overloaded due to obstruction
SC731    Upper Transport Motor Error (Proof Tray): B830
No encoder pulse signal is detected for the upper transport motor within 600 ms ( copyir.com  The 1st failure causes this SC code ( copyir.com     • Upper transport motor disconnected, defective • Finisher connection to upper transport motor loose, defective • Upper transport motor blocked by an obstruction • Upper transport motor defective • Finisher main board defective
SC732    Shift Tray Exit Motor: 3K Finisher B830
The shift tray exit motor is not operating ( copyir.com     • Motor harness loose, broken, defective • Motor is blocked by an obstruction • Motor defective • Finisher main control board defective
SC733    Stapler Exit Motor: B830
The stapler exit motor is not operating ( copyir.com     • Motor harness loose, broken, defective • Motor is blocked by an obstruction • Motor defective • Finisher main control board defective
SC734    Upper Tray Junction Gate Motor: 3K Finisher B830
The upper tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts ( copyir.com  -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open ( copyir.com     • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
SC735    Staple Junction Gate Motor Error: B830
The staple tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts ( copyir.com  -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open ( copyir.com     • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
SC736    Pre-Stack Junction Gate Motor Error: 3K Finisher B830
The pre-stack junction gate HP sensor did not detect the gate at the home position for within 200 ms after two attempts ( copyir.com  -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open ( copyir.com     • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
SC737    Pre-Stack Transport Motor Error: B830
The pre-stack transport motor is not operating ( copyir.com     • Motor harness loose, broken, defective • Motor is blocked by an obstruction • Motor defective • Finisher main control board defective
SC738    Pre-Stack Junction Gate Release Motor Error: B830
The pre-stack junction gate release HP sensor did not detect the gate at the home position within 200 ms after two attempts ( copyir.com  -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open ( copyir.com     • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
SC740    Finisher corner stapler motor error (B830)
The stapler motor does not switch off within the prescribed time after operating ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Staple jam • Number of sheets in the stack exceeds the limit for stapling • Stapler motor disconnected, defective
SC741    Finisher corner stapler rotation motor error
The stapler does not return to its home position within the specified time after stapling ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Stapler rotation motor disconnected, defective • Stapler rotation motor overloaded due to obstruction • Stapler rotation HP sensor disconnected, defective
SC742    Finisher stapler movement motor error
The stapler HP sensor is not activated within the specified time after the stapler motor turned on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Stapler movement motor disconnected, defective • Stapler movement motor overloaded due to obstruction • Stapler HP sensor disconnected, defective
SC743    Booklet stapler motor error 1
The front stapler unit saddle-stitch motor does not start operation within the specified time ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Front motor disconnected, defective • Front motor overloaded due to obstruction
SC744    Booklet stapler motor error 2
The rear stapler unit saddle-stitch motor does not start operation within the specified time ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Rear motor disconnected, defective • Rear motor overloaded due to obstruction
SC745    Feed-Out Belt Motor Error (D373/B830)
The stack feed-out belt HP sensor does not activate within the specified time after the stack feed-out belt motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     If the motor is operating 1 ( copyir.com  Stack feed-out HP sensor harness loose, broken, defective 2 ( copyir.com  Stack feed-out HP sensor defective If the motor is not operating: 1 ( copyir.com  Feed-out motor blocked by an obstruction 2 ( copyir.com  Feed-out motor harness loose, broken, defective 3 ( copyir.com  Feed-out motor defective 4 ( copyir.com  Booklet finisher main board defective
SC746    Stack Plate Motor Error 1: Front Motor (B830)
The stack plate HP sensor (front) does not activate within 500 ms after the motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     If the motor is operating 1 ( copyir.com  Front stack plate HP sensor harness loose, broken, defective 2 ( copyir.com  Front stack plate HP sensor defective If the motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Booklet finisher main board defective
SC747    Stack Plate Motor Error 2: Center Motor (B830)
The stack plate HP sensor (center) does not activate within 500 ms after the motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     If the motor is operating 1 ( copyir.com  Center stack plate HP sensor harness loose, broken, defective 2 ( copyir.com  Center stack plate HP sensor defective If the motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Booklet finisher main board defective
SC748    Stack Plate Motor Error 3: Rear Motor (B830)
The stack plate HP sensor (rear) does not activate within 500 ms after the motor turns on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code    If the motor is operating 1 ( copyir.com  Rear stack plate HP sensor harness loose, broken, defective 2 ( copyir.com  Rear stack plate HP sensor defective If the motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Booklet finisher main board defective
SC750    Finisher tray 1 (upper tray lift) motor error
The upper tray paper height sensor does not change its status with the specified time after the tray raises or lowers ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Tray lift motor disconnected, defective • Upper tray paper height sensor disconnected, defective • Finisher main board connection to motor loose • Finisher main board defective
SC753    Stacking Roller Motor Error (B830)
The return drive HP sensor did not detect the stacking roller at the HP sensor within 1 sec ( copyir.com  -or- The stacking roller did not leave the home position at the specified time ( copyir.com     If the motor is operating 1 ( copyir.com  Return drive HP sensor harness loose, broken, defective 2 ( copyir.com  Return drive HP sensor defective If the motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Finisher main board defective
SC754    Stacking Roller Drag Motor Error (B830)
The stacking roller drag motor did not turn on ( copyir.com     • Motor harness loose, broken, defective • Motor defective • Finisher control board defective
SC755    Shift Motor Error: 3K Finisher (B830)
The shift tray half-turn sensors: Failed twice to detect the shift tray at the home position at the specified time ( copyir.com  -or- Failed twice to detect that the shift tray had left the home position ( copyir.com     If the motor is operating 1 ( copyir.com  Half-turn sensor 1, 2 harnesses loose, broken, defective 2 ( copyir.com  One of the half-turn sensors defective If the motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Finisher main board defective
SC760    Finisher punch motor error (B830)
The punch HP sensor is not activated within the specified time after the punch motor turned on ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Punch HP sensor disconnected, defective • Punch motor disconnected, defective • Punch motor overload due to obstruction
SC761    Finisher folder plate motor error (D373)
The folder plate moves but is not detected at the home position within the specified time ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     Folder plate HP sensor disconnected, defective Folder plate motor disconnected, defective Folder plate motor overloaded due to obstruction ( copyir.com
SC763    Punch movement motor error
Occurs during operation of the punch unit ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     Motor harness disconnected, loose, defective Motor defective
SC764    Paper position sensor slide motor error
Occurs during operation of the punch unit ( copyir.com  The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     Motor harness disconnected, loose, defective Motor defective
SC765    Fold Unit Bottom Fence Lift Motor Error (D373)
The fold unit bottom fence did not return to the home position within the specified time ( copyir.com     • Fold bottom fence mechanism overloaded due to an obstruction • Fold bottom fence HP sensor connector loose, broken, defective • Fold bottom fence HP sensor defective • Fold bottom fence lift motor connector loose, broken, defective • Fold bottom fence lift motor defective • Main control board defective
SC766    Clamp Roller Retraction Motor (D373) The clamp roller did not return to the home position within the specified time ( copyir.com     • Clamp roller mechanism overloaded due to an obstruction • Clamp roller HP sensor connector loose, broken, defective • Clamp roller HP sensor defective • Clamp roller retraction motor connector loose, broken, defective • Clamp roller retraction motor defective • Main control board defective
SC767    Stack Junction Gate Motor (D373)
The stack junction gate did not return to the home position within the specified time ( copyir.com     • Stack junction mechanism overloaded due to an obstruction • Stack junction gate HP sensor connector loose, broken, defective • Stack junction gate HP sensor defective • Stack junction gate motor connector loose, broken, defective • Stack junction gate motor defective • Main control board defective
SC770    Cover Interposer Lift Motor 1 Error
In the first tray: • The upper limit sensor did not detect the bottom plate within the specified time after the lift motor switched on to lift the bottom plate ( copyir.com  • The lower limit sensor did not direct the bottom plate within the specified time after the lift motor switched on to lower the bottom plate ( copyir.com  Note: In both cases, 1 error count indicates a jam, 2 error counts cause this SC code ( copyir.com     • Lift motor, upper limit sensor, lower limit sensor harnesses, connectors loose, broken, defective • Lift motor defective • Upper limit sensor defective • Lower limit sensor defective
SC771    Cover Interposer Lift Motor 2 Error
In the second tray: • The upper limit sensor did not detect the bottom plate within the specified time after the lift motor switched on to lift the bottom plate ( copyir.com  • The lower limit sensor did not direct the bottom plate within the specified time after the lift motor switched on to lower the bottom plate ( copyir.com  Note: In both cases, 1 error count indicates a jam, 2 error counts cause this SC code ( copyir.com     • Lift motor, upper limit sensor, lower limit sensor harnesses, connectors loose, broken, defective • Lift motor defective • Upper limit sensor defective • Lower limit sensor defective
SC772    Cover Interposer Pickup Motor 1 Error
In the first tray: • While the pick-up roller motor was on, the pick-up roller HP sensor did not detect the pick-up roller at the home position within the specified number of pulses ( copyir.com  • While the pick-up roller motor was on, the pick-up roller HP sensor did not detect the pick-up roller at the home position above the specified number of pulses ( copyir.com  Note: In both cases, 1 error count indicates a jam, 2 error counts cause this SC code ( copyir.com     • The pick-up motor, pick-up roller HP sensor harnesses, connectors were loose, broken, defective • Pick-up motor overload due to an obstruction • Pick-up motor defective • Pick-up roller HP sensor defective
SC773    Cover Interposer Pickup Motor 2 Error
In the second tray: • While the pick-up roller motor was on, the pick-up roller HP sensor did not detect the pick-up roller at the home position within the specified number of pulses ( copyir.com  • While the pick-up roller motor was on, the pick-up roller HP sensor did not detect the pick-up roller at the home position above the specified number of pulses ( copyir.com  Note: In both cases, 1 error count indicates a jam, 2 error counts cause this SC code ( copyir.com     • The pick-up motor, pick-up roller HP sensor harnesses, connectors were loose, broken, defective • Pick-up motor overload due to an obstruction • Pick-up motor defective • Pick-up roller HP sensor defective
SC775    Jogger Top Fence Motor: 3K Finisher B830
The top fence HP sensor detected that: The top fence did not arrive at the home position within the specified number of pulses ( copyir.com  -or- The top fence failed to leave the home position within the specified number of pulses ( copyir.com     If the jogger top fence motor is operating: 1 ( copyir.com  Top fence HP sensor harness loose, broken, defective 2 ( copyir.com  Top fence HP sensor defective If the jogger top fence motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Finisher main board defective
SC776    Jogger Bottom Fence Motor (B830)
The bottom fence HP sensor detected that: The bottom fence did not arrive at the home position at the specified time ( copyir.com  -or- The bottom fence failed to leave the home position at the specified time ( copyir.com     If the jogger bottom fence motor is operating: 1 ( copyir.com  Bottom fence HP sensor harness loose, broken, defective 2 ( copyir.com  Bottom fence HP sensor defective If the jogger bottom fence motor is not operating: 1 ( copyir.com  Motor blocked by an obstruction 2 ( copyir.com  Motor harness loose, broken, defective 3 ( copyir.com  Motor defective 4 ( copyir.com  Finisher main board defective
SC778-1    Horizontal Transport Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC778-2    Top Tray Exit Motor Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC778-3    Top Tray JG Motor Multi Folder (D454)
The top tray JG HP sensor did not detect the top tray junction gate at (or out of) its home position ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Top tray JG HP sensor dirty • Sensor harness or connector loose, broken, defective • Top tray JG motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defectiveC code ( copyir.com
SC778-4    Entrance JG Motor Multi Folder (D454)
The entrance junction gate HP sensor did not detect the entrance junction gate at (or out of) its home position ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Entrance JG HP sensor dirty • Sensor harness or connector loose, broken, defective • Entrance JG motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defectiveC code ( copyir.com
SC779    1st Stopper Motor Error Multi Folder (D454)
The 1st stopper HP sensor did not detect the 1st stopper in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • 1st stopper HP sensor dirty • Sensor harness or connector loose, broken, defective • 1st stopper motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defectiveC code ( copyir.com
SC780    Z-Fold Feed Motor Error
The feed motor that drives the feed rollers and exit rollers in the Z-fold unit is not operating ( copyir.com  The 1st alert signals a jam, the 2nd alert triggers this SC ( copyir.com     • Motor harness loose, broken, defective • Motor blocked by an obstruction • Motor defective
SC781    Z-Fold Lower Stopper Motor Error
The lower stopper failed to leave the home position with the specified number of motor pulses ( copyir.com  Note: The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Lower stopper motor disconnected, defective • Lower stopper motor overloaded due to obstruction • Lower stopper HP sensor disconnected, defective
SC782    Z-fold Upper Stopper Motor
The upper stopper failed to leave the home position with the specified number of motor pulses ( copyir.com  Note: The 1st detection failure causes a jam error, and the 2nd failure causes this SC code ( copyir.com     • Upper stopper motor disconnected, defective • Upper stopper motor overloaded due to obstruction • Upper stopper HP sensor disconnected, defective
SC783-1    2nd Stopper Motor Error Multi Folder (D454)
The 2nd stopper HP sensor did not detect the 2nd stopper in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • 2nd stopper HP sensor dirty • Sensor harness or connector loose, broken, defective • 2nd stopper motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-10    Fold Plate Motor Error Multi Folder (D454)
The fold plate HP sensor did not detect the fold plate in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Fold plate HP sensor dirty • Sensor harness or connector loose, broken, defective • Fold plate motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defectiveard defective
SC783-11    Jogger Fence Motor Multi Folder (D454)
The jogger fence HP sensor did not detect the jogger fence in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Jogger fence HP sensor dirty • Sensor harness or connector loose, broken, defective • Jogger fence motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-12    Positioning Roller Motor Error Multi Folder (D454)
The positioning roller HP sensor did not detect the positioning roller in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Positioning roller HP sensor dirty • Sensor harness or connector loose, broken, defective • Positioning roller motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-13    FM2 Direct-Send JG Motor Multi Folder (D454)
The direct-send JG HP sensor did not detect the direct-send JG in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • FM2 direct-send JG HP sensor dirty • Sensor harness or connector loose, broken, defective • FM2 direct-send JG motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-14    FM6 Pawl Motor Multi Folder (D454)
The FM6 pawl HP sensor did not detect the FM6 pawl in (or out of) its home position ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • FM6 pawl HP sensor dirty • Sensor harness or connector loose, broken, defective • FM6 pawl motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-2    3rd Stopper Motor Error Multi Folder (D454)
The 3rd stopper HP sensor did not detect the 3rd stopper in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • 3rd stopper HP sensor dirty • Sensor harness or connector loose, broken, defective • 3rd stopper motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-3    1st Fold Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC783-4    2nd Fold Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC783-5    Crease Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC783-6    Dynamic Roller Transport Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC783-7    Reg ( copyir.com  Roller Transport Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor ( copyir.com     • Motor harness or connector loose, broken, defective • Motor or motor drive board defective
SC783-8    Dynamic Roller Lift Motor Error Multi Folder (D454)
The dynamic roller HP sensor did not detect the dynamic roller in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Dynamic roller HP sensor dirty • Sensor harness or connector loose, broken, defective • Dynamic roller lift motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC783-9    Registration Roller Release Motor Error Multi Folder (D454)
The registration roller HP sensor did not detect the registration roller in (or out of) its home position within the prescribed time ( copyir.com  The 1st occurrence causes a jam, and the 2nd occurrence causes this SC code ( copyir.com     • Registration roller HP sensor dirty • Sensor harness or connector loose, broken, defective • Registration roller release motor harness or connector loose, broken, defective • Sensor defective • Motor or motor drive board defective
SC784    Z-Fold Timing Sensor Adjustment Error 1
The output voltage light emitted from the sensor changed, but the return input was not sufficient to attain V0 ( copyir.com     • Sensor, mirror dirty from paper dust, other particles • Harness loose, broken, defective • Mirror out of position
SC785    Z-Fold Timing Sensor Adjustment Error 2
The output voltage light emitted from the sensor changed, but the return input was not sufficient to attain V0 ( copyir.com     • Sensor, mirror dirty from paper dust, other particles • Harness loose, broken, defective • Mirror out of position
SC786    Z-Fold Memory Error
Several attempts to write to the Zfold memory failed ( copyir.com     • Turn the machine power off/on • EEPROM on Z-Folder main board defective
SC789    Proof Tray Exit Motor Error Multi Folder (D454)
The motor drive PCB detected an error at the motor due to overload, overheating ( copyir.com  Paper cannot exit at proof tray ( copyir.com     • Motor, motor drive board defective
SC792-1    Junction gate error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 36 pulses) (1 detection, jam, twice detected, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 22 pulses) (1 detection, jam, twice detected, SC error)    • Path JG motor (M201) defective • Motor connector loose, broken, defective • Motor overload • Path JG sensor (S203) connector loose, broken, defective • Sensor (S203) defective
SC792-10    Binder unit runout error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Runout press roller motor (M610) connector loose, broken, defective • Motor defective • Motor overload • Runout roller HP sensor (S614) connector loose, broken, defective • Sensor defective
SC792-11    Clamp thickness error 50-sheet detection sensor (S606) went OFF during pre-bind jogging when a 100- sheet thickness was detected ( copyir.com  (1st detection jam, 2nd detection SC error) -or- 50-sheet detection sensor went OFF at initialization when the clamp moved to the open position ( copyir.com     • 50-sheet detection sensor (S606) connector loose, broken, defective • Sensor defective
SC792-12    Alignment pin error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Alignment pin motor (M602) connector loose, broken, defective • Motor overload • Motor defective • Alignment pin HP sensor (S604) connector loose, broken, defective • Sensor defective
SC792-13    Pre-bind jogger shutter error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Shutter motor (M608) connector loose, broken, defective • Motor overload • Motor defective • Shutter HP sensor (S605) connector loose, broken, defective • Sensor defective
SC792-15    Timing sensor interval error
The bind timing sensor (S702) remained ON or OFF longer than the prescribed time (1500 ms) during initialization or ring binding (1st detection: jam, 2nd detection: SC error)    • Clamp unit motor (M701) connector loose, broken, defective • Motor overload • Motor defective • Bind timing sensor (S702) connector loose, broken, defective • Sensor defective
SC792-16    Clamp unit HP error
At initialization or during ring binding, did not arrive at the home position within the prescribed time (1500 ms) (1st detection: jam, 2nd detection: SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 1500 ms) (1st detection, jam, 2nd detection, SC error)    • Clamp unit motor (M701) connector loose, broken, defective • Motor overload • Motor defective • Clamp unit HP sensor (S701) connector loose, broken, defective • Sensor defective
SC792-17    Spine alignment error
During pin alignment operation, the pin did not reach the up position or return to the home position with the prescribed time (400 ms), and one retry failed within the same time limit ( copyir.com     • Alignment pin motor (M602) connector loose, broken, defective • Motor overload • Motor defective • Alignment pin HP sensor (S604) connector loose, broken, defective, or sensor defective • Alignment pin up sensor (S610) connector loose, broken, defective, or sensor defective • Stack not jogged correctly, or not punched correctly
SC792-18    Binder unit not detected
The binder unit could not be detected at initialization ( copyir.com     • Drawer connector loose, broken, defective • Drawer connector defective
SC792-2    Pre-punch side fence HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 600 pulses) (1st detection, jam, 2nd detection, SC error)    • Side jogger motor (M302) connector loose, broken, defective • Motor overload • Motor defective • Pre-punch jogger HP sensor (S301) connector loose, broken, defective • Sensor (S301) defective
SC792-20    Output belt 1 HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 200 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 2125 pulses) (1st detection, jam, 2nd detection, SC error)    • Output belt 1 motor (M401) connector loose, broken, defective • Motor overload • Motor defective • Output belt 1 HP sensor (S401) connector loose, broken, defective • Sensor defective
SC792-21    Output belt 2 HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 200 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 3130 pulses) (1st detection, jam, 2nd detection, SC error)    • Output belt 2 motor (M402) connector loose, broken, defective • Motor overload • Motor defective • Output belt 2 HP sensor (S402) connector loose, broken, defective • Sensor defective
SC792-22    Stack height error
Stack height sensor remained ON while moving toward the top ( copyir.com  -or- The sensor did not go ON within 6 sec ( copyir.com  after the motor turned on ( copyir.com     • Stacker motor (M501) connector loose, broken, defective • Motor overload • Stack height sensor (S502) connector loose, broken, defective • Sensor defective
SC792-23    Stacker error
Although the stacker was full at the start and end of stacker operation with the stacker full (stacker sensors ON together), no documents were detected (also when documents were leaning) -or- Although the stacker was detected full with the stacker stopped, no documents were detected within 2 sec ( copyir.com  (1st detection jam, 2nd detection SC error)    • Stacker HP sensor (S501) connector loose, broken, defective, or sensor defective • Stacker height HP sensor (S502) connector loose, broken, defective, or sensor defective • Stacker detect sensor (S504) loose, broken, defective, or sensor defective
SC792-3    Pre-punch jogger roller HP error
Detected at HP after the time prescribed to leave the HP had elapsed (more than 36 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 22 pulses) (1st detection, jam, 2nd detection, SC error)    • Jog roller lift motor (M305) connector loose, broken, defective • Motor overload • Motor defective • Jog roller lift HP sensor (S309) connector loose, broken, defective • Sensor defective
SC792-4    Punch defective
One or more of the following occurred: • Punch unit not detected at initialization ( copyir.com  • No motor rotation detected at HP at 30 ms after the DC motor turned on • No encoder pulse detected at HP at 5 ms after the DC motor turned on • Not detected at HP at 400 ms after the DC motor turned on    • Punch motor (M304) connector loose, broken, defective • Motor overload • Motor defective • Punch HP sensor (S302) connector loose, broken, defective, or sensor defective • Punch encoder sensor (S303) connector loose, broken, defective, or sensor defective
SC792-5    Paddle roller HP error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Paddle roller lift motor (M603) connector loose, broken, defective • Motor overload • Motor defective • Paddle roller HP sensor (S602) connector loose, broken, defective • Sensor defective
SC792-6    Jogger fence 1 error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Jog fence 1 motor (M604) connector, loose, broken, defective • Motor defective • Motor overload • Side fence 1 HP sensor (S601) connector, loose, broken, defective • Sensor defective
SC792-7    Jogger fence 2 error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Jog fence 2 motor (M606) connector, loose, broken, defective • Motor defective • Motor overload • Side fence HP sensor 1 (S611) connector loose, broken, defective • Sensor defective
SC792-8    Stack tamper HP error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Stack tamper motor (M607) connector, loose, broken, defective • Motor defective • Motor overload • Stack tamper HP sensor (S612) connector loose, broken, defective • Sensor defective
SC792-9    Pre-bind jogger clamp HP error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)    • Spine clamp motor (M605) connector loose, broken, defective • Motor defective • Motor overload • Clamp HP sensor (S603) connector loose, broken, defective • Sensor defective
SC816    Energy save I/O subsystem error
An error was detected in the signal from the ASIC (controller board) which controls the STR (Suspend to RAM) function ( copyir.com  Note: STR is a feature of this machine that minimizes energy consumption while the machine is in the energy saver mode ( copyir.com     • Reboot the machine ( copyir.com  • Replace the controller board ( copyir.com
SC817    Boot loader error
The boot loader cannot read one of the following: self-diagnostic module, kernel, or one of the files of the root file system, or the check of one of these items on the system SD card failed ( copyir.com     • File or module on the system SD card is corrupted • File or module on the system SD card is illegal • Make sure that the system SD card is the one designed for the machine • Replace controller board ( copyir.com
SC819    Fatal kernel error
Due to a control error, a RAM overflow occurred during system processing ( copyir.com  One of the following messages was displayed on the operation panel ( copyir.com     • System program defective • Controller board defective • Optional board defective • Replace controller firmware
SC821    Self-diagnostic error 1: ASIC
The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate ( copyir.com     • ASIC (controller board defective)
SC822    Self-diagnostic error 2: HDD
SC824    Self-diagnostic error 3: NVRAM
NVRAM device does not exist, NVRAM device is damaged, NVRAM socket damaged    • NVRAM defective • Controller board defective • NVRAM backup battery exhausted • NVRAM socket damaged
SC829    Self-diagnostic error 5: Optional RAM
Verify error for optional RAM ( copyir.com     • Make sure that the resident RAM is installed in the correct slot ( copyir.com  • Make sure the optional RAM is installed in the correct slot (Slot 0)
SC833    Self-diagnostic error 8: Engine I/F ASIC
SC834    Self-diagnostic error 9: Optional Memory RAM DIMM    • Controller defective
SC850    Net I/F error
Duplicate IP addresses ( copyir.com  Illegal IP address ( copyir.com  Driver unstable and cannot be used on the network ( copyir.com     • IP address setting incorrect • Ethernet board defective • Controller board defective
SC858    Data Encryption Error 1 These are errors of the HDD Data Encryption Option D377 ( copyir.com
SC859    Data Encryption Error 2
SC861    HDD re-try failure
At power on with the HDD detected, power supply to the HDD is interrupted, after the HDD is awakened from the sleep mode, the HDD is not ready within 30 s ( copyir.com     Harness between HDD and board disconnected, defective HDD power connector disconnected HDD defective Controller board defective
SC863    HDD data read failure
The data written to the HDD cannot be read normally, due to bad sectors generated during operation ( copyir.com     HDD defective Note: If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM, and the next time the HDD is accessed, these bad sectors will not be accessed for read/write operation ( copyir.com
SC864    HDD data CRC error
During HDD operation, the HDD cannot respond to an CRC error query ( copyir.com  Data transfer did not execute normally while data was being written to the HDD ( copyir.com     HDD defective
SC865    HDD access error
HDD responded to an error during operation for a condition other than those for SC863, 864 ( copyir.com     HDD defective ( copyir.com
SC867    SD card error 2: SD card removed
The SD card in the boot slot when the machine was turned on was removed while the machine was on ( copyir.com     Insert the SD card, then turn the machine off and on ( copyir.com
SC868    SD card error 3: SD card access
An error occurred while an SD card was being used ( copyir.com     • SD card not inserted correctly • SD card defective • Controller board defective
SC870    Address book data error
Address book data on the hard disk was detected as abnormal when it was accessed from either the operation panel or the network ( copyir.com  The address book data cannot be read from the HDD or SD card where it is stored, or the data read from the media is defective ( copyir.com     • Software defective ( copyir.com  • Cycle the machine off/on ( copyir.com  • Replace controller firmware ( copyir.com  • HDD defective
SC874    Delete All error 1: HDD
A data error was detected for the HDD/ NVRAM after the Delete All option was used ( copyir.com  Note: The source of this error is the Data Overwrite Security Unit running from an SD card ( copyir.com     • Turn the main switch off/on and try the operation again ( copyir.com  • Install the Data Overwrite Security Unit again ( copyir.com  ( copyir.com  • HDD defective
SC875    Delete All error 2: Data area
An error occurred while the machine deleted data from the HDD ( copyir.com     • Cycle the machine off/on ( copyir.com  • Try the operation again ( copyir.com
SC901    Mechanical Counter 1 error
Mechanical Counter 1 was not set correctly at power on, or the operator disconnected the counter while machine was operating ( copyir.com     • Mechanical Counter 1 connection loose or defective • Mechanical Counter 1 defective
SC902    Mechanical Counter 2 error
Mechanical Counter 2 was not set correctly at power on, or the operator disconnected the counter while machine was operating ( copyir.com
SC910 … SC914    External controller error
SC919    External controller down
The EAC received an interrupt signal from the FLUTE serial driver during print jobs in progress and the connection between the copier and external controller was broken ( copyir.com     • Switch the machine off and on ( copyir.com
SC925    Net File function error
The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue ( copyir.com  The HDDs are defective and they cannot be debugged or partitioned, so the Scan Router functions (delivery of received faxes, document capture, etc ( copyir.com ), Web services, and other network functions cannot be used ( copyir.com  HDD status codes are displayed below the SC code:  

 

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید