ریکو آفشیو Ricoh Aficio SPC730DN

ایرادات دستگاههای ریکو براساس کد می باشد. شرکت کپی ایران در نظر دارد تمامی سرویس مانوئلها و رفع ایرادات را در اختیار شما عزیزان قرار دهد.

 

 

 

195-00    S/N input error
Compare the product ID code of the product S/N (11 digits) ( copyir.com     The product ID code of the product S/N (11 digits) does not match
230-01    FGATE: Does not turn ON Bk
GBIO has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time ( copyir.com     Control Board
230-02    FGATE: Does not turn ON C
GBIO has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time ( copyir.com     Control Board
230-03    FGATE: Does not turn ON M
GBIO has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time ( copyir.com     Control Board
230-04    FGATE: Does not turn ON Y
GBIO has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time ( copyir.com     Control Board
231-01    FGATE: Does not turn OFF Bk
GPIO has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time ( copyir.com  * This is an I/O pin ( copyir.com  Such I/O pins can be used for a variety of applications, depending on the setting ( copyir.com     • Control Board • Engine Board
231-02    FGATE: Does not turn OFF C
GPIO has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time ( copyir.com  * This is an I/O pin ( copyir.com  Such I/O pins can be used for a variety of applications, depending on the setting ( copyir.com     • Control Board • Engine Board
231-03    FGATE: Does not turn OFF M
GPIO has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time ( copyir.com  * This is an I/O pin ( copyir.com  Such I/O pins can be used for a variety of applications, depending on the setting ( copyir.com     • Control Board • Engine Board
231-04    FGATE: Does not turn OFF Y
GPIO has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time ( copyir.com  * This is an I/O pin ( copyir.com  Such I/O pins can be used for a variety of applications, depending on the setting ( copyir.com     • Control Board • Engine Board
270-00    Write ASIC communication error
• When the Engine Board could not read the Unique ID of the Writing ASIC properly when starting this machine ( copyir.com  • When an Error bit occurred in the communication between the Engine Board and the Writing ASIC ( copyir.com     The unique ID of the write ASIC was not read normally ( copyir.com
277-01    LEDA communication errore Board Bk
The head type data was read three times in succession    • LED Head error • Harness Error
277-02    LEDA communication errore Board C
The head type data was read three times in succession    • LED Head error • Harness Error
277-03    LEDA communication errore Board M
The head type data was read three times in succession    • LED Head error • Harness Error
277-04    LEDA communication errore Board Y
The head type data was read three times in succession    • LED Head error • Harness Error
332-01    Toner supply feed lock Bk
Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession ( copyir.com  n: The value was set at SP3-131-015 ( copyir.com     • Disconnected or broken Solenoid: Upper cover ( copyir.com  (Failed to open the toner supply shutter) • Disconnection of Toner Supply Clutch • Failed PCDU ( copyir.com  (Toner leak) • Toner clogging
332-02    Toner supply feed lock C
Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession ( copyir.com  n: The value was set at SP3-131-015 ( copyir.com     • Disconnected or broken Solenoid: Upper cover ( copyir.com  (Failed to open the toner supply shutter) • Disconnection of Toner Supply Clutch • Failed PCDU ( copyir.com  (Toner leak) • Toner clogging
332-03    Toner supply feed lock M
Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession ( copyir.com  n: The value was set at SP3-131-015 ( copyir.com     • Disconnected or broken Solenoid: Upper cover ( copyir.com  (Failed to open the toner supply shutter) • Disconnection of Toner Supply Clutch • Failed PCDU ( copyir.com  (Toner leak) • Toner clogging
332-04    Toner supply feed lock Y
Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession ( copyir.com  n: The value was set at SP3-131-015 ( copyir.com     • Disconnected or broken Solenoid: Upper cover ( copyir.com  (Failed to open the toner supply shutter) • Disconnection of Toner Supply Clutch • Failed PCDU ( copyir.com  (Toner leak) • Toner clogging
364-01    Toner End Sensor output count error Bk
The output count from the Toner End Sensor indicates an average of 0 ( copyir.com     – Bad connector contact or connector disconnected/wire broken – Failed TE Sensor
364-02    Toner End Sensor output count error C
The output count from the Toner End Sensor indicates an average of 0 ( copyir.com     – Bad connector contact or connector disconnected/wire broken – Failed TE Sensor
364-03    Toner End Sensor output count error M
The output count from the Toner End Sensor indicates an average of 0 ( copyir.com     – Bad connector contact or connector disconnected/wire broken – Failed TE Sensor
364-04    Toner End Sensor output count error Y
The output count from the Toner End Sensor indicates an average of 0 ( copyir.com     – Bad connector contact or connector disconnected/wire broken – Failed TE Sensor
365-01    Toner End Sensor upper limit sensor error Bk
The Toner End Sensor still indicates that the remaining amount of toner is at the “upper limit”, although 30 g or more toner has been consumed ( copyir.com     – Stained TE Sensor surface – Failed TE Sensor
365-02    Toner End Sensor upper limit sensor error C
The Toner End Sensor still indicates that the remaining amount of toner is at the “upper limit”, although 30 g or more toner has been consumed ( copyir.com     – Stained TE Sensor surface – Failed TE Sensor
365-03    Toner End Sensor upper limit sensor error M
The Toner End Sensor still indicates that the remaining amount of toner is at the “upper limit”, although 30 g or more toner has been consumed ( copyir.com     – Stained TE Sensor surface – Failed TE Sensor
365-04    Toner End Sensor upper limit sensor error Y
The Toner End Sensor still indicates that the remaining amount of toner is at the “upper limit”, although 30 g or more toner has been consumed ( copyir.com     – Stained TE Sensor surface – Failed TE Sensor
370-01    TM(ID) Sensor calibration error (Right)* The specular light output voltage (Vsg_reg) of the Right TM (ID) Sensor cannot be calibrated to a value in the target range ( copyir.com  Upper limit (initially 2 ( copyir.com 97 V) Lower limit (initially 2 ( copyir.com 31V)    – Disconnected TM(ID) Sensor connector/bad contact – Stained TM(ID) Sensor window – Failed TM(ID) Sensor – Image Transfer Belt loosened or out of place
370-02    TM(ID) Sensor calibration error (Left)
The specular light output voltage (Vsg_reg) of the Left TM(ID) Sensor cannot be calibrated to a value in the target range ( copyir.com  Upper limit (initially 2 ( copyir.com 97 V) Lower limit (initially 2 ( copyir.com 31V)    – Disconnected TM(ID) Sensor connector/bad contact – Stained TM(ID) Sensor window – Failed TM(ID) Sensor – Image Transfer Belt loosened or out of place
396-01    Drum Motor: K Error
Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state ( copyir.com  Motor Stop Timing • A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
396-05    Drum Motor: CMY error
Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
441-00    Transfer motor error
Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     • Disconnected connector • Broken signal wire • Excessive motor torque • Torque of the Image Transfer Unit is too large • Torque of the Waste Toner processing system is too large • Failed Paper Exit Full Sensor
442-01    Intermediate transfer contact Sensor error (01: Home position error, 02: Contact error, 03: Non-contact error)
– Home position error: SC442-01 If the home position is not set within the T4 time after turning ON the feed motor and feed clutch, an error results ( copyir.com  – Contact error: SC442-02 If the contact state is not set within the T3 time after turning ON the feed motor and feed clutch, an error results ( copyir.com  – Non-contact error: SC442-03 If the non-contact state is not set within the T3 time after turning ON the feed motor and feed clutch, an error results ( copyir.com  [Error time T3] SP value: 100 to 25500 ms Initial value: 3000 ms Note: Contact/non-contact error judgment [Error time T4] SP value: 100 to 25500 ms Initial value: 3000 ms Note: Home position error judgment ( copyir.com     • High motor load • Failed motor • Disconnected connector • Broken harness wire • PSU: +24 V fuse blown • Failed interlock mechanism • Failed Engine Board
460-00    Separation: Output error
The “HVP_ERR_D output error Sensor signal” is monitored at 20 ms intervals ( copyir.com  If 0 (error) is detected ten times in succession (200 ms), the following causes are suspected:    • Transfer Roller error • High Voltage Power Supply (Separation) error • Damaged HVP connection harness
490-00    Charging/developing: Output error
The “HVP_ERR1: Output error Sensor signal” is monitored at 20 ms intervals ( copyir.com  If 0 (error) is detected ten times in succession (200 ms), the following causes are suspected:    • Failed PCDU • Failed High Voltage Power Supply (Separation) • Damaged HVP connection harness
491-01    Primary/secondary transfer: Output error
The “HVP_ERR2: Output error Sensor signal” is monitored at 20 ms intervals ( copyir.com  If 0 (error) is detected ten times in succession (200 ms) (during bias output), the following causes are suspected:    • Image Transfer Unit error • Transfer Roller error • Damaged HVP connection harness • Noise generated by poor contact of the power supply terminals of the Development Roller
491-02    Disconnected connector: High voltage output error
The “HVP_ERR2: Output error Sensor signal” is monitored at 20 ms intervals ( copyir.com  If 0 (error) is detected ten times in succession (200 ms) (during non-bias output), the following causes are suspected    • HVP Connect harness disconnected • Damaged HVP connection harness
498-00    Temperature/humidity Sensor error
• Temperature Sensor output error: Out of range between 076 V and 2 ( copyir.com 90 V • Humidity Sensor output error: 2 ( copyir.com 4 V or more    – Unmounted Sensor (Unset connector or broken wire) – Failed Sensor
508-00    By-pass bottom plate operation error
The signal from the by-pass bottom plate position Sensor has not changed (that is, the signal has not changed from ON to OFF or vice versa) for two seconds or more after the start of reverse Paper Feed Unit rotation, If the error is detected three times in succession, the appropriate SC number is displayed on the operation panel unit ( copyir.com     – By-pass bottom plate Sensor connector disconnected or other error – By-pass bottom plate Sensor feeler stuck or other error
520-02    Fusing motor error Early Detection
• A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
521-01    Bank 1 motor error (Bank: paper tray unit)
Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
521-02    Bank 2 motor error (Bank: paper tray unit)
Early Detection A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
521-03    Bank 3 motor error (Bank: paper tray unit) Early Detection
A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
530-00    Cooling fan error
The fan motor lock (rotating state) signal is sampled 30 times at 100 ms intervals and the fan goes into an unstable rotating state at least ten times ( copyir.com  (No error detection occurs for two seconds after the start of the fan or after changing the speed ( copyir.com )    – Failed fan motor ( copyir.com  – Disconnected connector ( copyir.com
531-00    Fusing fan error
The fan motor lock (rotating state) signal is sampled 30 times at 100 ms intervals and the fan goes into an unstable rotating state at least ten times ( copyir.com  (No error detection occurs for two seconds after the start of the fan or after changing the speed ( copyir.com )    – Failed fan motor – Disconnected connector
532-00    PSU cooling fan
The fan motor lock (rotating state) signal is sampled 30 times at 100 ms intervals and the fan goes into an unstable rotating state at least ten times ( copyir.com  (No error detection occurs for two seconds after the start of the fan or after changing the speed ( copyir.com )    – Failed fan motor – Disconnected connector
540-00    Paper Feed Unit error
Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating ( copyir.com  Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state ( copyir.com  Motor Stop Timing A command to stop the rotation of the motor has been issued, but the motor is still rotating ( copyir.com     – Disconnected connector – Broken signal wire – Excessive motor torque
541-00    Broken fusing (Center) thermopile wire
At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds ( copyir.com     – Broken thermopile wire – Bad connector contact
542-02    Fusing lamp (Center) thermopile not reloaded 1
The heater (Center) thermopile does not reach 50 deg C 2 ( copyir.com 4 seconds after the start of heat control (during normal startup control) ( copyir.com     • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
542-03    Fusing lamp (Center) thermopile not reloaded 2
The heater (Center) thermistor does not reach the reload temperature 44 seconds after the start of motor rotation ( copyir.com     • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
542-04    Fusing lamp (Center) thermopile not reloaded 3
The heater (Center) thermistor does not reach 100 deg C 5 ( copyir.com 5 seconds after the start of heat control (during low-temperature start up control) ( copyir.com     • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
543-00    Fusing (Center) thermopile high-temperature detected (software)
The temperature is detected to stay at 230 deg C or higher for one second ( copyir.com     • Shorted triac • Failed Engine Board
544-00    Fusing (Center) thermopile high-temperature detected (hardware)
The hardware high-temperature error Sensor flag is detected at 10 ms intervals ( copyir.com     • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error) ( copyir.com
545-00    Fusing (Center) heater stay ON
The fusing (Center) heater stays ON for 5 ( copyir.com 7 seconds or more when in stand-by state (or the fusing roller is not rotating) ( copyir.com     • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
547-01    Zero-crossing error (adhered relay contact)
When the fusing relay is in an OFF state, a “zero-crossing interrupt request” occurs in 50 ms ( copyir.com     Damaged fusing relay (adhered contact)
547-02    Zero-crossing error (bad relay contact)
If a “zero-crossing interrupt request” does not occur when the fusing relay is in an ON state, an error results ( copyir.com     – Damaged fusing relay (open contact) – Failed fusing relay drive circuit – PSU fuse (24VS) blown
547-03    Zero-crossing error (low frequency error)
The number of zero-crossing interrupts does not reach a certain value in 500 ms ( copyir.com     The frequency of the commercial power supply line is unstable ( copyir.com
551-00    Broken fusing (End) thermistor wire
At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds ( copyir.com     – Broken thermistor wire – Bad connector contact
552-02    Fusing (End) thermistor not reloaded 1
The heating (End) thermistor does not reach 80 deg C 7 ( copyir.com 7 seconds after the start of heat control (during normal startup control)    • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
552-03    Fusing (End) thermistor not reloaded 2
The heating (End) thermistor does not reach 80 deg C 7 ( copyir.com 7 seconds after the start of heat control (during normal startup control)    • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
552-04    Fusing (End) thermistor not reloaded 3
The heating (End) thermistor does not reach 80 deg C 7 ( copyir.com 7 seconds after the start of heat control (during normal startup control)    • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
553-00    Fusing (End) thermistor high-temperature detected (software)
The temperature is detected to stay at 230 deg C or higher for one second ( copyir.com     • Shorted triac • Failed Engine Board
554-00    Fusing (End) thermistor high-temperature detected (software)
The hardware high-temperature error Sensor flag is detected at 10 ms intervals ( copyir.com     • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error) ( copyir.com
555-00    Fusing (End) heater stay ON
The fusing (End) heater stays ON for 8 ( copyir.com 6 seconds or more when in stand-by state (or the fusing roller is not rotating) ( copyir.com     • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
557-00    Zero-crossing frequency exceeded
The number of zero-crossing interrupts exceeds a certain value in 500 ms ( copyir.com     The frequency of the commercial power supply line is unstable or noise occurs
559-00    Fusing jam detected 3 times in succession
Fusing jam is detected three times in succession ( copyir.com     Paper is wrapped around the fusing roller ( copyir.com
561-00    Broken pressure (Center) thermistor wire
At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds ( copyir.com     – Broken thermistor wire – Bad connector contact
562-00    Pressure (Center) thermistor not reloaded
The pressure (Center) thermistor does not reach 40 deg C 17 ( copyir.com 8 seconds after the start of heat control (during normal startup control) ( copyir.com     • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
563-00    Pressure (Center) thermistor high-temperature detected (software)
The temperature is detected to stay at 230 deg C or higher for one second ( copyir.com     • Shorted triac • Failed Engine Board
564-00    Pressure (Center) thermistor high-temperature detected (hardware)
The pressure (Center) thermopile temperature becomes 250 or higher ( copyir.com  (The hardware high-temperature error Sensor flag is detected at 10 ms intervals ( copyir.com )    • Damaged triac (shorted) • Failed Engine Board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error) ( copyir.com
571-00    Broken pressure (End) thermistor wire At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds ( copyir.com     – Broken thermistor wire – Bad connector contact
573-00    Pressure (Center) thermistor high-temperature detected (software)
The temperature is detected to stay at 230 deg C or higher for one second ( copyir.com e seconds    • Shorted triac • Failed Engine Board
574-00    Pressure (End) thermistor high
The pressure (Center) thermopile temperature becomes 250 deg C or higher ( copyir.com  (The hardware high)    • Damaged triac (shorted) • Failed Engine Board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error) ( copyir.com
636-01    Expanded authentication module error
If the expanded authentication management is set to “Enabled”, an error is detected when: • There is no external expanded authentication module in the machine; • The SD card or the file of the expanded authentication module is broken;    • There is no external expanded authentication module in the machine ( copyir.com  • The SD card or the file of the expanded authentication module is broken
636-02    IC card error
When the version of the expanded authentication module is not correct ( copyir.com     The version of the expanded authentication module is not correct ( copyir.com
637    Tracking information notification error
When the tracking information is lost ( copyir.com
650    Communication error of the remote service modem
When an error in the communication line of the Cumin-M Embeded RC gate as a modem due to the incorrect Embeded RC gate Cumin modem setting is detected when the power is turned on ( copyir.com
651-00    Incorrect dial-up connection by the remote service modem
When the unexpected error occurs when the Embeded RC gate as a modem Cumin-M tries to call the center with a dial-up connection ( copyir.com
652-00    Remote service ID2 mismatch error
When the ID2 of the individual certificate for the device does not match the ID2 of the NVRAM ( copyir.com     • The controller board has been replaced with the one with which the Embeded RC gate Cumin was installed to the different machine in the past ( copyir.com  • The NVRAM has been replaced with the one that was once used in the different machine ( copyir.com
653-00    Incorrect ID2 for the remote service
When the ID2 stored in the NVRAM has one of the following problems: • The string length is not 17 ( copyir.com  • Includes the characters that cannot be printed ( copyir.com  • All space characters ( copyir.com  • NULL    Replace the NVRAM ( copyir.com
669    EEPROM communication error
An error is notified during EEPOM communication and the printer does not recover after three retries ( copyir.com
670-00    Engine startup error
Case 1: • When the main power is turned on or when the machine is recovering from energy saver mode, the /ENGRDY signal assertion fails ( copyir.com  • After the main power is turned on, the engine does not make the EC response within the specified time ( copyir.com  • After the main power is turned on, the engine does not make the PC response within the specified time ( copyir.com  • Writing of the Rapi driver failed (not recognized by PCI) ( copyir.com  Case 2: After the /ENGRDY signal assertion, an unintended shutdown is detected ( copyir.com     Case 1: • The Engine Board does not start up ( copyir.com  Case 2: The Engine Board is reset at an unintended timing ( copyir.com
672    Controller startup error
• When communication between the controller and the operation panel does not begin normally after the machine is powered on or if communication is interrupted after a normal startup ( copyir.com  • When the controller does not send an attention code (FDH) or attention acknowledge code (FEH) within 15 to 30 seconds after the operation panel is reset ( copyir.com  • After the operation panel issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice ( copyir.com
674-01    Transfer error
An M2P error has occurred ( copyir.com     Defective Controller Board/software
674-02    Transfer error
A PCI error interrupt is generated by the expanded engine ASIC (SELENE,SELENE2)    PCI error
688-00    PRREQ signal not asserted
The print request signal (PRREQ) signal is not asserted within the prescribed time after paper reaches the registration stand-by position,    – Noise – Engine Board error
790-00    Maximum number of banks (paper tray units) exceeded error
When the power is turned ON, the number of mounted paper tray units is detected and the number exceeds three ( copyir.com     The number of mounted paper tray units exceeds the specifications ( copyir.com
816    Error detected by Energy efficient I/O subsystem
When the energy efficient I/O subsystem detects some kind of error ( copyir.com     • Defective energy efficient I/O subsystem • The energy efficient I/O subsystem has found an error in the Controller Board (no response) ( copyir.com  • An error was detected during the preparation for the STR migration ( copyir.com
820-00    Self-diagnostic error: CPU
No interrupt is supposed to occur after the Interrupt 0 is used ( copyir.com     • Defective CPU device • Defective ASIC device
840-00    EEPROM access error
While executing I/O to the EEPROM, an error is detected: • When a read error still occurs even after three attempts; • When a write error has occurred ( copyir.com     EEPROM is defective or has reached its end of life ( copyir.com
841-00    Error in data read from the EEPROM
When mirrored data read from three different regions in the EEPROM differ each other ( copyir.com     For some reason, the data stored in a particular region of the EEPROM has been overwritten ( copyir.com
842-00    Verification error in the Nand-Flash update
When updating the remote ROM and the ROM, SCS encountered an error in writing to the Nand-Flash memory that holds the module data ( copyir.com     Defective Nand-Flash memory ( copyir.com
853-00    Bluetooth device connection error
When a Bluetooth hardware device (USB type) is connected after startup ( copyir.com     A Bluetooth hardware device (USB type) has been connected after startup ( copyir.com
854-00    Bluetooth device removal error
When a Bluetooth hardware device (USB type) is removed after startup ( copyir.com     A Bluetooth hardware device (USB type) has been removed after startup ( copyir.com
855    Wireless LAN card error    Defective wireless LAN card or poor contact
858    Serious encrypted data conversion error    • Data corruption in a USB Flash memory device, etc ( copyir.com  • Communication error caused by electromagnetic noise, etc ( copyir.com  Out-of-order Controller Board
859    HDD conversion error during encrypted data conversion
When the HDD conversion that is performed while updating the data encryption key fails ( copyir.com  While performing conversion, the error is only indicated on the screen and does not generate any SC ( copyir.com  However, a Mode SC is issued after rebooting ( copyir.com     • Check the HDD connection ( copyir.com  • Initialize the HDD ( copyir.com  • Replace the HDD
860-00    Hard disk startup error at power-on
863    HDD data read failure
When the data stored in the HDD cannot be read properly ( copyir.com     A bad sector occurred during operation ( copyir.com
864    HDD data CRC error
When the CRC error reply is returned from the hard disk during HDD operation ( copyir.com     A bad sector occurred during operation ( copyir.com
865    HD access error
When the error reply is returned during HDD operation ( copyir.com     The error reply returned from the HDD was other than SC863 (bad sector) or SC864 (CRC error) ( copyir.com  ((Branch numbers 01 to 23 refer to the generated partition codes, a to v, respectively ( copyir.com )
866-00    SD card authentication error
When a correct license for digital authentication is not found in a SD card application ( copyir.com     The SD card contains the wrong program data ( copyir.com
867    SD card removal detection
When an application SD card is removed from the slot while the application is activated ( copyir.com
868    SD card access error
When an error reply is returned while the SD controller board is in operation ( copyir.com     • Defective SD card • Defective SD controller
870    Address book data error
During startup or machine operation, an error is detected in the handling and the configuration of the address book data ( copyir.com     • Software bug • Incorrect reference to the address book data source (inside the machine, delivery server settings, and LDAP settings) • Inconsistent encryption settings and encryption key (This occurs as a result of a failure to initialize the address book data whenever replacing NVRAM or HDD ( copyir.com ) • The media that stores the address book data-such as SD card or HDD-has been removed, or the machine configuration does not match the application setting ( copyir.com  • Data corruption was detected while accessing the address book data ( copyir.com
872-00    HDD mail received data error
An error is detected in the HDD at machine power-on    • Defective HDD • Power failure while accessing the HDD
873-00    HDD mail transfer error
An error is detected in the HDD at machine power-on ( copyir.com     • Defective HDD • Power failure while accessing the HDD
875    Delete All error (HDD)
An error is detected before executing HDD Erase ( copyir.com
876-00    Log data error An error was detected in the handling and configuration of the log data at power up or during machine operation ( copyir.com
878    TPM system authentication error
881    Management area error
Defective software has been detected ( copyir.com     Abnormal accumulation of authentication information in the software
900    Electronic counter error
The value provided by the electronic total counter is outside the normal range ( copyir.com     • Unexpected NVRAM installed • Defective NVRAM • NVRAM data corruption • Data is stored in an unexpected area due to external causes ( copyir.com  • The count requests made by SRM upon receiving the PRT have not yet been processed ( copyir.com
920    Printer application error
A serious application error that stops the machine from operating is detected ( copyir.com
921    Printer font error
925-00    Net File function error
The Net File storage area on the HDD is not available, or the management file used for handling the Net File data is broken ( copyir.com  As a result, access to the Net File data cannot be continued ( copyir.com     • Defective HDD • HDD inconsistency caused by switching the machine off while writing to HDD • Software bug
990-00    Software performance error
The software attempted to make an unexpected operation ( copyir.com     • Incorrect argument • Incorrect internal parameter • Insufficient working memory • Abnormal performance caused by an error that cannot be detected in normal SC detection due to hardware specifications ( copyir.com
991-00    Software continuity error
The software has attempted to perform an unexpected operation ( copyir.com  (However, the process can continue running if recovery processing is carried out ( copyir.com )    • Incorrect argument • Incorrect internal parameter • Insufficient working memory • May have resulted from an error that cannot be detected by the hardware using normal SC detection ( copyir.com
992-00    Undefined SC error
An error that is not controlled by the system occurred (the error does not come under any other SC code) ( copyir.com     A SC code used in the previous machine was applied erroneously ( copyir.com
995    CPM setting error
The product ID code and product S/N (11 digits) are compared ( copyir.com     The product ID code or product S/N (11 digits) does not match ( copyir.com
997-00    Application function selection error
• The application has not responded to the set command created by SCS within a certain period of time ( copyir.com  • The application selected ended abnormally ( copyir.com     Software bug
998-00    Application start error
• After power on, no application program is registered to the system within a predetermined period of time ( copyir.com  (No application starts or ends normally ( copyir.com ) • Even if they are started, all applications have become unable to be rendered due to an unknown defect ( copyir.com     • Software bug • An option required by the application (RAM, DIMM, board) is not installed properly