ریکوRicoh ML325

ایرادات ریکو براساس کد می باشد. شرکت کپی ایران در نظر دارد تمامی سرویس مانوئلها و رفع ایرادات را در اختیار شما عزیزان قرار دهد.

 

 

01    Transfer roller leak error 1
A current leak signal for the transfer roller is detected ( copyir.com  A current feedback signal for the transfer roller is not detected ( copyir.com     • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
101    Exposure Lamp Error
The peak white level is 64/255 digit or less (8 bit) when scanning the white plate ( copyir.com     • Exposure lamp defective • Exposure lamp stabilizer defective • Exposure lamp connector defective • Dirty scanner mirror or scanner mirror out of position • SBU board defective • SBU connector defective • Lens block out of position • Incorrect position or width of white plate scanning (SP4015)
120    Scanner home position error 1
The scanner home position sensor does not detect the off condition during initialization or copying ( copyir.com     • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • BICU board defective
121    Scanner home position error 2
The scanner home position sensor does not detect the on condition during initialization or copying ( copyir.com     • Scanner home position sensor defective • Scanner drive motor defective • Scanner home position sensor connector defective • Scanner drive motor connector defective • BICU board defective
141    Black offset level correction error
The black level cannot be adjusted within the target value during the automatic SBU adjustment ( copyir.com     • SBU board defective
143    SBU white/black level correction error
The automatic SBU adjustment has • Exposure lamp defective failed to correct the black level ( copyir.com  The automatic SBU adjustment has failed to correct the white level twenty times consecutively ( copyir.com     • Exposure lamp defective • Dirty white plate • Incorrect position or width of white plate scanning (SP4015) • BICU board defective • SBU board defective
144    Communication Error between BICU and SBU
The BICU board cannot detect the SBU connect signal ( copyir.com     • The flat cable between the BICU board and the SBU has a poor connection • The flat cable between the BICU board and the SBU is damaged • BICU board defective • SBU defective
145    Automatic SBU adjustment error
During the automatic SBU adjustment, the machine detects that the white level read from the white plate or paper is out of range ( copyir.com (SP4015)
193    Image transfer error
Scanned images are not transferred to the controller memory within 1 minute ( copyir.com     • BICU board defective • Controller board defective
198    Memory address error
The BICU board does not receive memory addresses from the controller board ( copyir.com     • The firmware programs of the engine and the controller do not match ( copyir.com  • BICU board defective • Controller board defective
202    Polygon Motor Error 1: ON Timeout
The machine does not detect the polygon motor lock signal for 10 seconds after the polygon motor has turned on ( copyir.com     • Polygon motor defective • SCRATCH error • I/F harness disconnected or loose
203    Polygon Motor Error 2: OFF Timeout
The machine does not detect the polygon motor unlock signal for 3 seconds after the polygon motor has turned off ( copyir.com     • Polygon motor defective • SCRATCH error • I/F harness disconnected or loose
204    Polygon Motor Error 3: XSCRDY Signal Error
The machine does detect the polygon motor unlock signal for 0 ( copyir.com 2 seconds after the polygon motor has turned on ( copyir.com     • Polygon motor defective • SCRATCH error • I/F harness disconnected or loose
220    Laser synchronization error
The main scan synchronization detector board cannot detect the laser synchronization signal for more than 5 consecutive 100 ms intervals ( copyir.com     • Poor connection between the LD unit and the BICU board • Damaged cable between BICU and LD unit • LD unit out of position • LD unit defective • BICU board defective
230    No laser writing signal (F-GATE) error
The laser-writing signal (F-GATE) fails to turn Low after the laser crosses 5 mm on the drum surface from the laser writing start position ( copyir.com     • BICU board defective • The fax controller or printer controller has a poor connection • Fax controller or printer controller defective
302    Charge roller current leak
A current leak signal for the charge roller is detected ( copyir.com     • Charge roller damaged • High voltage supply board defective • Poor connection of the PCU
390    TD sensor error
The TD sensor outputs less than 0 ( copyir.com 2 V or more than 4 ( copyir.com 0 V 10 times consecutively during copying ( copyir.com     • TD sensor abnormal • Poor connection of the PCU
391    Development bias leak
A development bias leak signal is detected ( copyir.com     • Poor connection of the PCU • High voltage supply board defective
392    TD sensor initial setting error
TD sensor initial setting is not performed correctly ( copyir.com     • ID sensor defective • No developer • Drum does not turn • Development roller does not turn • Poor connection of the PCU • The voltage is not applied to charge roller
402    Transfer roller leak error 2
A current leak signal for the transfer roller is detected ( copyir.com  A current feedback signal for the transfer roller is not detected ( copyir.com     • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
411    Discharge leak error
High-voltage power supply board detects the 50% or more of PWM duty for 0 ( copyir.com 2 seconds ( copyir.com     • Discharge plate defective • High-voltage power supply board defective
490    Toner supply motor: Excess current error
The machine detects the current of 1A or more supplied to the toner supply motor for 0 ( copyir.com 2 seconds ( copyir.com     • Toner supply motor short circuit
500    Main motor lock
A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal ( copyir.com     • Too much load on the drive mechanism • Main motor defective
501    Tray 1 lift motor malfunction
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds ( copyir.com     • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
502    Tray 2 lift motor malfunction
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds ( copyir.com     • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
503    Tray 3 lift motor malfunction (optional paper tray units)
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds ( copyir.com     • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
504    Tray 4 lift motor malfunction (optional two-tray paper tray unit)
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds ( copyir.com     • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
506    Paper feed motor lock (optional paper tray unit)
A motor lock signal is not detected for more than 1 ( copyir.com 5 s or the lock signal is not detected for more than 1 ( copyir.com 0 s during rotation ( copyir.com     • Paper feed motor defective • Too much load on the drive mechanism
541    Fusing thermistor open (center)
The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on ( copyir.com     • Fusing thermistor defective or out of position • Power supply board defective • Loose connectors
542    Fusing temperature warm-up error (center)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively ( copyir.com  The fusing temperature is not detected in 25 or 35 seconds ( copyir.com     • Fusing thermistor defective or out of position • Fusing lamp open • Power supply board defective
543    Fusing overheat error (center)
The fusing temperature is over 230°C for 1 second (detected by the thermistor) ( copyir.com     • Fusing thermistor defective • Power supply board defective
544    Fusing overheat error (center) 2
The fusing temperature is over 250°C for 1 second (detected by the fusing temperature monitor circuit) ( copyir.com     • Fusing thermistor defective • Power supply board defective
545    Fusing lamp overheat error (center)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 12 consecutive seconds ( copyir.com     • Fusing thermistor defective or out of position • Power supply board defective
546    Unstable fusing temperature (center)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times ( copyir.com     • Thermistor defective or out of position • Power supply unit defective
547    Zero cross signal malfunction
The relay terminal of the fusing unit is melted, zero cross signals are not detected within 3 seconds after the main power switch is turned on, or detected zero cross signals are 44 times or less ( copyir.com     • Discharge plate defective • High-voltage supply board defective • BICU defective
551    Fusing thermistor open (rear)
The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on ( copyir.com     • Fusing thermistor defective or out of position • Power supply board defective • Loose connectors
552    Fusing temperature warm-up error (rear)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively ( copyir.com  The fusing temperature is not detected in 25 or 35 seconds ( copyir.com     • Fusing thermistor defective or out of position • Fusing lamp open • Power supply board defective
553    Fusing overheat error (rear)
The fusing temperature is over 230°C for 1 second (detected by the thermistor) ( copyir.com     • Fusing thermistor defective • Power supply board defective
555    Fusing lamp overheat error (rear)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds ( copyir.com     • Fusing thermistor defective or out of position • Power supply board defective
556    Unstable fusing temperature (rear)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times ( copyir.com     • Thermistor defective or out of position • Power supply unit defective
557    Zero cross frequency error
When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs ( copyir.com     • Noise (High frequency)
559    Jam error detected 3 times in succession
• The exit sensor and the duplex sensor detect a paper jam 3 times in succession • This condition can occur when SP 1159 1 is set to ‘on’ ( copyir.com  The default is ‘off’ ( copyir.com     Paper jams can occur for the following reasons ( copyir.com  • Dampness • Paper curl • Incorrect paper setting in the paper tray • Stripper pawls coming apart
590    Left exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds ( copyir.com     • Loose connection of the exhaust fan motor • Too much load on the motor drive
591    Rear exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds ( copyir.com     • Loose connection of the exhaust fan motor • Too much load on the motor drive
620    Communication error between BICU and ARDF
The BICU does not receive a response from the ARDF main board for 4 seconds or more ( copyir.com  The BICU receives a break signal from the ARDF main board ( copyir.com     • Poor connection between the BICU and ARDF main board (DF connector) • ARDF main board defective • BICU defective
621    ARDF connection error
An incorrect ARDF (an ARDF for some other copier) is detected ( copyir.com  (for Basic and GDI machines) An ARDF (including the correct ARDF) is installed while the copier is in the energy saver mode ( copyir.com  (for GDI machine only)    • ARDF incorrect (The other ARDF is installed on the D010 ( copyir.com ) • The connector of the ARDF is removed while the machine is in the energy saver mode ( copyir.com
632    Accounting error
An error is detected during the communication with the MF accounting device ( copyir.com     • Accounting device defective • Loose connection
634    Accounting RAM error
An error is detected in the RAM that saves the information on the MF accounting ( copyir.com     • Accounting device defective
635    Accounting battery error
An error is detected in the battery that is in the MF accounting device ( copyir.com     • Accounting device defective
692    Controller board communication abnormal
Communication error between the printer part of the controller board and BICU ( copyir.com     • The connector is abnormal between the controller board and the BICU board ( copyir.com
694    Controller board communication abnormal
Communication error between the scanner part of the controller board and BICU ( copyir.com     • The connector is abnormal between the controller board and the BICU board ( copyir.com
740    Finisher corner stapler motor error
The stapler HP sensor does not detect “ON”/”OFF” signal even the stapler motor rotates from the “OFF”/”ON” position for 0 ( copyir.com 6 seconds ( copyir.com  The stapler HP sensor does not detect “ON” when a stapling job is commanded or the stapler unit moves ( copyir.com     • Staple jam • Motor overload • Defective stapler motor
742    Finisher stapler movement motor error
The stapler unit HP sensor does not detect “OFF” signal even the stapler moves from the “ON” position for 0 ( copyir.com 35 seconds ( copyir.com  The stapler HP sensor does not detect “ON” signal even the stapler moves from the “OFF” position for 5 ( copyir.com 5 seconds ( copyir.com     • Motor overload • Loose connection of the stapler unit home position sensor • Loose connection of the stapler movement motor • Defective stapler unit home position sensor • Defective stapler movement motor
750    Output tray motor error
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code ( copyir.com  • The machine does not detect correctly the position of the output tray when the output tray motor starts to rotate ( copyir.com     • Output tray motor defective • Loose connection • Motor overload • Upper limit sensor and/ or stack near limit sensor defective
760    ARDF gate abnormal 1
The ARDF Gate signal line between the ARDF main board and the BICU is disconnected ( copyir.com     • ARDF main board defective • Input/output board defective • Poor connection (ARDF Gate line) between the ARDF main board and the BICU ( copyir.com
761    ARDF gate abnormal 2
The FGATE signal is not issued from the ARDF within 30 seconds after the ARDF starts feeding ( copyir.com     • ARDF connector defective • SBU board defective
762    ARDF gate abnormal 3
The FGATE signal is not terminated by the ARDF within 60 seconds after the ARDF starts feeding ( copyir.com     • ARDF connector defective • SBU board defective
792    Finisher error
The machine does not recognize the finisher, but recognizes the bridge unit ( copyir.com     • Defective connector • Defective harness • Incorrect installation
793    Front jogger motor error
• The machine does not detect that the front jogger HP sensor is OFF for 40 ms after the front jogger fence moved ( copyir.com  • The machine does not detect that the front jogger fence HP sensor is ON for 830 ms after the front jogger fence returned to its home position ( copyir.com     • Defective front jogger motor • Disconnected connector • Overload to front jogger motor • Defective front jogger fence HP sensor
794    Rear jogger motor error
• The machine does not detect that the rear jogger HP sensor is OFF for 40 ms after the rear jogger fence moved ( copyir.com  • The machine does not detect that the rear jogger fence HP sensor is ON for 830 ms after the rear jogger fence returned to its home position ( copyir.com     • Defective rear jogger motor • Disconnected connector • Overload to rear jogger motor • Defective rear jogger fence HP sensor
795    Pick-up roller HP sensor error
• The pick-up roller HP sensor does not turn off for 650 msec after the pick-up roller has lifted down ( copyir.com  • The pick-up roller HP sensor does not turn on for 650 msec after the pick-up roller has lifted up ( copyir.com     • Disconnected harness • Defective pick-up roller contact motor • Defective pick-up roller HP sensor
796    Transport belt solenoid error
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code ( copyir.com  • The machine does not detect that the belt lift sensor is ON at initializing after the paper transport motor has rotated ( copyir.com     • Disconnected harness • Defective paper transport motor • Belt lift sensor defective
797    EEPROM data error
The job data is not transferred to the EEPROM ( copyir.com     • Defective EEPROM on the control board
901    Mechanical total counter
The mechanical total counter does not work properly ( copyir.com     • Mechanical total counter defective • BICU defective • Disconnected mechanical total counter
903    Engine total counter error
The checksum of the total counter is not correct ( copyir.com     • NVRAM on the BICU defective
928    Memory error
The machine detects a discrepancy in the write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode) ( copyir.com     • Memory defective • BICU defective • Poor connection between BICU and memory
929    IMAC hardware error
IMAC error is registered when the GDI controller starts IMAC ( copyir.com  Memory job does not complete after the GDI controller has started IMAC ( copyir.com     • IMAC defective • IPU defective
954    Printer application program error
The printer status does not become ready when the printer application program is necessary for image processing ( copyir.com     • Application program defective
955    Image transfer error
The controller is not able to transfer images when the engine needs them ( copyir.com     • Application program defective
964    Status error (laser optics housing unit)
The optics-housing unit does not become ready within 17 seconds after the request ( copyir.com     • Software defective
981    NVRAM error
The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i ( copyir.com e ( copyir.com  during actual use) ( copyir.com     • NVRAM defective • Poor connection between BICU and NVRAM • NVRAM is not connected • BICU defective
982    Localization error
The localization settings in the nonvolatile ROM and RAM are different (SP5807) ( copyir.com     • First machine start after the NVRAM is replaced • Incorrect localization setting • NVRAM defective
984    Print image transfer error
Print images are not transferred ( copyir.com     • Controller defective • BICU board defective • Poor connection between controller and BICU