E1-00    Communication trouble between MCU and E-Sort.
Communication setup error, framing, parity, protocol error    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-10    E-Sort PWB trouble
Communication trouble between MCU and E-Sort    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-11    E-Sort PWB ASIC error
E-Sort PWB ASIC abnormality    An ASIC abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises ASIC peripheral circuit error
E1-12    E-Sort PWB CODEC error
A CODEC error is detected in the E-Sort PWB. Control circuit hung up due to noises CODEC peripheral circuit error    Replace the E-Sort PWB. Check grounding of the machine.
E1-13    E-Sort PWB Flash ROM error
E-Sort PWB Flash ROM abnormality    A Flash ROM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Flash ROM peripheral circuit error
E1-14    E-Sort PWB Work RAM error
E-Sort PWB Work RAM abnormality    A Work RAM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises RAM peripheral circuit error
E1-15    E-Sort PWB Page Memory error
E-Sort PWB Page Memory abnormality    A Page Memory abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Page Memory peripheral circuit error
E1-16    E-Sort PWB SIMM error
E-Sort PWB SIMM abnormality    A SIMM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises SIMM peripheral circuit error
E1-17    E-Sort PWB image rotating RAM error
E-Sort PWB image rotating RAM abnormality    An image rotating RAM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Image rotating RAM peripheral circuit error
E1-80    E-Sort PWB communication trouble (protocol  copyir.com
Communication trouble between MCU and printer PWB (Protocol error  copyir.com    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-81    E-Sort PWB communication trouble (Parity  copyir.com
Communication trouble between MCU and printer E-Sort (Parity error  copyir.com    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-82    E-Sort PWB communication trouble (Overrun  copyir.com
Communication trouble between MCU and E-Sort PWB (Overrun error  copyir.com    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-84    E-Sort PWB communication trouble (Framing  copyir.com
Communication trouble between MCU and E-Sort PWB (Framing error  copyir.com    E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E1-88    E-Sort PWB communication trouble (Time-out  copyir.com
Communication trouble between MCU and E-Sort PWB (Time-out error  copyir.com    E-Sort PWB connector disconnection E-Sort PWB and MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
E7-03    LSU trouble
After the polygon motor becomes active, BD signal (HSYNC  copyir.com from the LSU is not detected at the specified times (41 +- 10 times within 20msec  copyir.com.    LSU connector disconnection or LSU’s inside harness disconnection or breakage Polygon motor rotation abnormality Improper positioning of the laser home position sensor in the LSU. Laser power voltage failure Laser emitting diode abnormality MCU PWB abnormality
E7-04    CCD white level trouble
CCD white reference level which is read during the copy lamp lighting is abnormal.    Flat cable installation failure to CCD unit Dirt on the mirror, lens, and reference white plate Copy lamp lighting failure CCD unit installation failure CCD unit abnormality MCU PWB abnormality
E7-05    CCD black level trouble
CCD black level which is read while the copy lamp is off is abnormal.    Flat cable installation failure CCD unit abnormality MCU PWB abnormality
F1-06    Shifter motor trouble
The home position is not detected within 1 sec after shifter motor drive.    The shifter home position sensor is defective. The shifter motor is defective. The shifter motor periphery circuit is defective. The condition of the MCU PWB JP4 is wrong. The assembly of the shifter motor unit is improper.
F2-04    CRUM data read trouble
Communication error between CRUM PWB and MCU PWB    CRUM PWB data error MCU PWB error MCU PWB EEPROM error Disconnection between CRUM (toner cartridge  copyir.com and MCU PWB
F5-02    Copy lamp error
Copy lamp voltage detection error    Power unit trouble Copy lamp trouble Inverter trouble MCU PWB trouble
F9-00    Communication trouble between MCU and printer PWB (MCU detection  copyir.com
Communication establishment error, framing error, parity error, protocol error    Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
F9-10    Printer PWB trouble
Communication trouble between MCU and printer PWB    Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
F9-80    Printer PWB communication trouble (Protocol  copyir.com
Communication trouble between MCU and printer PWB (Protocol error  copyir.com    Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
F9-81    Printer PWB communication trouble (Parity  copyir.com
Communication trouble between MCU and printer PWB (Parity error  copyir.com    Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
F9-82    Printer PWB communication trouble (Overrun  copyir.com
Communication trouble between MCU and printeu PWB (Overrun error  copyir.com    Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
F9-84    Printer PWB communication trouble (Framing  copyir.com
Communication trouble between MCU and printer PWB (Framing error  copyir.com    Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
F9-88    Printer PWB communication trouble (Time-out  copyir.com
Communication trouble between MCU and printeu PWB (Time-out error  copyir.com    Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
H2-00    Thermistor open detection
Fusing thermistor open    Thermistor defect MCU PWB defect Fusing section connector contact failure Power supply failure Fusing unit not installed
H3-00    Heat roller abnormally high temperature
Fusing temperature of 220 ~ 240°C.    Thermistor defect MCU PWB defect Fusing connector connection failure Power supply failure
H4-00    Heat roller abnormally low temperature
When the temperature does not reach 155°C within 55 sec after turning on the power, or when it falls under 145°C during printing, or when it falls under 100°C during pre-heating    Thermistor failure Heater lamp failure MCU PWB failure Thermostat failure Power supply failure Interlock switch failure
L1-00    Mirror base feed trouble
The mirror home position (MHPS  copyir.com does not turn off though the feed operation is completed during mirror initial operation after turning on the power. The mirror home position (MHPS  copyir.com does not turn off during shading operation. The mirror home position (MHPS  copyir.com does not turn on when the mirror base is returned for the specified time after copy feed is started and SPF scanning position shift is performed.    Mirror unit defect Mirror home position sensor defect MCU PWB defect Scanner wire disconnection
L3-00    Mirror base return trouble
The mirror home position (MHPS  copyir.com does not turn on though the mirror base returning is completed during mirror initial operation after turning on the power. The mirror home position does not turn on when the mirror is returned to the home position during shading. The mirror home position (MHPS  copyir.com does not turn on when the mirror base returning is completed for the specified time (about 6 sec  copyir.com after copy return start.    Mirror unit Mirror home position sensor defect MCU PWB defect Scanner wire disconnection
L4-01    Main motor lock
The main motor encoder pulse is not detected for 400msec.    Main motor defect Harness disconnection between the MCU PWB and the main motor. Control circuit failure
L4-10    Job separator motor trouble
When the home is not detected within 2.5 sec after the job separator tray starts to move upwards.    The job separator upper limit detection sensor is defective. The job separator motor is defective. The job separator motor periphery circuit is defective. The condition of the MCU PWB JP5 is wrong.
L6-10    Polygon motor lock
The lock signal (the specified rotation speed signal  copyir.com is not supplied within the specified time (about 6 sec  copyir.com after starting the polygon motor rotation.    LSU connector disconnection or harness disconnection in the LSU.
L8-01    Zero cross pulse (FW  copyir.com trouble
Zero cross pulse width is shifted by 55Hz +-10% or more.    MCU PWB defect Power supply unit breakdown
U2-04    EEPROM serial communication error
Error in communication with EEPROM    EEPROM failure Installation of uninitialized EEPROM MCU PWB EERPOM access circuit faiure
U2-11    Counter check sum error
Counter check sum value stored in the EEPROM is abnormal.    EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit defect
U2-12    Adjustment value check sum error (EEPROM  copyir.com
Adjustment value data area check sum error    EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit failure
U2-40    CRUM communication error
Toner cartridge CRUM data read error    A toner cartridge of a different destination is installed. EEPROM trouble Check the destination setup. Toner cartridge CRUM PWB trouble MCU PWB trouble CRUM connector disconnection
U3-29    Mirror base home position error
Home position is not detected when starting mirror base shift.    Mirror unit defect Mirror home position sensor defect MCU PWB decfect Scanner wire disconnection
U9-00    Communication trouble between MCU and OPE (OPE detection  copyir.com
Communication setup error, framing, parity, protocol error    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-80    Operation control PWB communication trouble (Protocol  copyir.com
Communication trouble between MCU and the operation control PWB (Protocol error  copyir.com    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-81    Operation control PWB communication trouble (Parity  copyir.com
Communication trouble between MCU and the operation control PWB (Parity error  copyir.com    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-82    Operation control PWB communication trouble (Overrun  copyir.com
Communication trouble between MCU and the operation control PWB (Overrun error  copyir.com    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-84    Operation control PWB communication trouble (Framing  copyir.com
Communication trouble between MCU and the operation control PWB (Framing error  copyir.com    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-88    Operation control PWB communication trouble (Time-out  copyir.com
Communication trouble between MCU and the operation PWB (Time-out error  copyir.com    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U95    Operation control PWB communication error
Communication error between the operation control PWB and the MCU PWB (Detected by the OPE-PWB  copyir.com    Disconnection or reverse connection of the flat cable between the Operation control PWB and the MCU PWB. Operation control PWB trouble MCU PWB trouble Connector trouble of the operation control PWB and the MCU PWB
U99    Operation control PWB communication error
Communication error between the operation control PWB and the MCU PWB (Detected by the OPE-PWB  copyir.com    Disconnection or reverse connection of the flat cable between the Operation control PWB and the MCU PWB. Operation control PWB trouble MCU PWB trouble Connector trouble of the operation control PWB and the MCU PWB

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید