E1-00    IMC PWB communication trouble
An abnormality occurs in communication between the MCU PWB and the IMC PWB  copyir.com     IMC PWB-MCU PWB harness abnormality  copyir.com
MCU PWB connector disconnection  copyir.com
IMC PWB ROM defect/data abnormality
E1-10    IMC PWB trouble
An abnormality occurs in the IMC PWB  copyir.com     USB chip error/CODEC error on the IMC PWB  copyir.com
E1-11    IMC ASIC error
An abnormality occurs in the IMC PWB  copyir.com     Abnormality in ASIC on the IMC PWB  copyir.com
E1-13    IMC PWB flash ROM error
An abnormality occurs in the IMC flash ROM  copyir.com     IMC PWB abnormality  copyir.com
E1-16    IMC PWB DIMM memory read/write check error
An installation error occurs in the IMC expansion compression memory module  copyir.com
An error occurs during access to the IMC expansion compression memory  copyir.com     Improper installation of the IMC expansion memory module  copyir.com
IMC expansion memory module abnormality  copyir.com
IMC expansion memory contact abnormality  copyir.com
IMC PWB abnormality  copyir.com
E1-81    Interface error in communication with IMC PWB (Parity)
A parity error occurs in communication between the MCU PWB and the IMC PWB    IMC PWB-MCU PWB harness defect  copyir.com
Improper connection of the MCU PWB connector  copyir.com
IMC PWB ROM defect/data abnormality  copyir.com
E1-82    Interface error in communication with IMC PWB (Overrun)
An overrun error occurs in communication between the MCU PWB and the IMC PWB  copyir.com     IMC PWB-MCU PWB harness defect  copyir.com
Improper connection of the MCU PWB connector  copyir.com
IMC PWB ROM defect/data abnormality  copyir.com
E1-84    Interface error in communication with IMC PWB (Framing)
A framing error occurs in communication between the MCU PWB and the IMC PWB  copyir.com     IMC PWB-MCU PWB harness defect
Improper connection of the MCU PWB connector  copyir.com
IMC PWB ROM defect/data abnormality  copyir.com
E7-01    Duplex model memory error
The memory capacity for the duplex model machine is improper  copyir.com  Insufficient memory capacity  copyir.com     The memory capacity of the MCU PWB is improper  copyir.com
E7-02    LSU trouble
The BD signal from the LSU cannot be detected in a certain cycle  copyir.com  (Always OFF or always ON)    LSU connector or LSU harness defect or disconnection  copyir.com
Polygon motor rotation abnormality  copyir.com
Laser beams are not generated  copyir.com
MCU PWB abnormality  copyir.com
E7-10    Shading trouble (Black correction)
The CCD black scan level is abnormal when the shading    Improper connection of the CCD unit flat cable
CCD unit abnormality  copyir.com
MCU PWB abnormality  copyir.com
E7-11    Shading trouble (White correction)
The CCD white scan level is abnormal when the shading  copyir.com     Improper connection of the CCD unit flat cable
Dirt on the mirror, the lens, and the reference white plate  copyir.com
Copy lamp lighting abnormality  copyir.com
CCD unit abnormality  copyir.com
MCU PWB abnormality(When occurred in the SPF scan position)  copyir.com
Improper installation of the mirror unit  copyir.com
E7-12    Shading trouble
White correction is not completed in the specified number of operations  copyir.com     CCD unit flat cable connection failure  copyir.com
Dirt on mirrors, lenses, and the reference white plate  copyir.com
Copy lamp lighting abnormality  copyir.com
CCD unit abnormality  copyir.com
MCU PWB abnormality   copyir.com
E7-16    Abnormal laser output
When the laser output is stopped, HSYNC is detected  copyir.com     Laser abnormality  copyir.com
MCU PWB abnormality  copyir.com
F2-02    Toner supply abnormality
When toner near end is detected with the toner supply time of 50% or less When the toner supply time exceeds 300%  copyir.com   copyir.com     ATC sensor abnormality
Toner supply abnormality
F2-04    Improper cartridge (destination error, life cycle error)
The destination of the machine differs from that of the CRUM  copyir.com  The life cycle information is other than “Not used (FFh)”  copyir.com     CRUM chip defect  copyir.com
Improper developing unit   copyir.com
F2-40    ATC sensor abnormality
ATC sensor value abnormality    Connector connection trouble
Toner cartridge installation trouble
Sensor breakdown
F5-02    Copy lamp lighting abnormality
The copy lamp does not turn on  copyir.com     Copy lamp abnormality  copyir.com
Copy lamp harness abnormality  copyir.com
CCD PWB harness abnormality  copyir.com
F6-00    FAX board communication trouble
FAX board communication error  copyir.com     No command can be sent from the MCU to the FAX  copyir.com
F6-10    FAX board trouble
FAX board abnormality detection  copyir.com     FAX controller and FAX board memory abnormality  copyir.com
F6-80    FAX board communication trouble (Protocol)
A break error occurs in communication between the MCU and the FAX board  copyir.com     MCU PWB connector connection failure/ Garbled data  copyir.com
F6-81    FAX board communication trouble (Parity)
A parity error occurs in communication  copyir.com  between the MCU and the FAX board  copyir.com     MCU PWB connector connection failure/ Garbled data  copyir.com
F6-82    FAX board communication trouble (Overrun)
An overrun error occurs in communication between the MCU and the FAX board  copyir.com     MCU PWB connector connection failure/ Garbled data
F6-84    FAX board communication trouble (Framing)
A framing error occurs in communication between the MCU and the FAX board  copyir.com     MCU PWB connector connection failure/ Garbled data  copyir.com
F6-88    FAX board communication trouble (Time out)
FAX board communication error  copyir.com     There is no respond command from the FAX for 30sec or more  copyir.com
F6-97    Combination error between the FAX unit and the main unit
Combination error between the FAX unit and the main unit    When this fax unit is installed to the machine that can not install this  copyir.com
F6-99    Machine – FAX language error
Discrepancy of the destination of the machine and the FAX board  copyir.com     The destination of the machine differs from that of the FAX board  copyir.com
When installing to the machine that can install only AR-FX11  copyir.com
F9-00    MX-NB10 communication trouble
MX-NB10 print data reception error  copyir.com     Print data cannot be received from the MX-NB10 for 3 min or more  copyir.com
H2-00    Thermistor open
The thermistor is open  copyir.com  The fusing unit is not installed  copyir.com     Thermistor abnormality  copyir.com
Control PWB abnormality  copyir.com
Fusing section connector disconnection  copyir.com
The fusing unit is not installed  copyir.com
H3-00    Heat roller high temperature detection
The fusing temperature exceeds 240C°  copyir.com     Thermistor abnormality  copyir.com
Control PWB abnormality  copyir.com
Fusing section connector disconnection  copyir.com
H4-00    Heat roller low temperature detection
When the fusing temperature is lower than 150C° after 55sec from the start of warming up  copyir.com
When the warming up complete temperature is not reached in 30sec from reaching 150C°  copyir.com
When the fusing temperature is lower than 100C° after 20sec from ready start  copyir.com
When the fusing temperature is lower than 145C° when printing  copyir.com     Thermistor abnormality  copyir.com
Heater lamp abnormality  copyir.com
Thermostat abnormality  copyir.com
Control PWB abnormality  copyir.com
H5-01    5-time continuous detections of POUT not-reached jam
Paper not-reached jams are detected 5 times or more continuously by the paper exit sensor (POUT)  copyir.com  The jam counter is backed up and used for jobs after turning on the power  copyir.com     A fusing jam is not canceled completely  copyir.com  (A jam paper remains in the machine  copyir.com )
Paper exit sensor trouble or harness connection trouble
Defective installation of the fusing unit  copyir.com
L1-00    Scanner feed trouble
The scanner does not complete feeding in the specified time  copyir.com     Mirror unit abnormality  copyir.com
The scanner wire is disconnected  copyir.com
The origin detection sensor abnormality  copyir.com
Mirror motor harness abnormality  copyir.com
L3-00    Scanner return trouble
The scanner does not complete returning in the specified time  copyir.com
The mirror is not in the home position when OC copying is started with the mirror standby in the home position  copyir.com     Mirror unit abnormality  copyir.com
Scanner wire disconnection  copyir.com
Origin detection sensor abnormality  copyir.com
Mirror motor harness abnormality  copyir.com
L4-01    Main motor lock detection
The main motor does not rotate  copyir.com
The motor lock signal is detected for 1sec or more after rotation of the main motor  copyir.com
The motor lock signal is detected for 1sec during rotation of the main motor  copyir.com     Main motor unit abnormality  copyir.com
Improper connection or disconnection the main motor and the harness  copyir.com
MCU PWB abnormality  copyir.com
L4-11    Shifter motor trouble
The shifter home position detection signal is not detected when initializing the shifter  copyir.com     Shifter motor abnormality, improper connection or disconnection of the harness, shifter home position sensor abnormality  copyir.com
L6-10    Polygon motor lock detection
The polygon motor does not rotate  copyir.com
The motor lock signal is detected for 6sec after rotation of the polygon motor  copyir.com  The motor lock signal is detected for 1sec during rotation of the polygon motor  copyir.com     Polygon motor unit abnormality
Improper connection or disconnection of the polygon motor and the harness  copyir.com
MCU PWB abnormality  copyir.com
L8-01    No full wave signal
The zero cross signal is not detected  copyir.com     Power unit abnormality  copyir.com
MCU PWB abnormality  copyir.com
U1-03    FAX board battery error
FAX board backup battery error  copyir.com     The voltage of the backup battery of SRAM which is installed to the FAX board falls below a certain level  copyir.com
U2-04    EEPROM read/write error (serial communication error)
EEPROM access process error  copyir.com     EEPROM abnormality  copyir.com
U2-11    Counter check sum error (EEPROM)
Check sum error of the counter area in the EEPROM  copyir.com     EEPROM abnormality  copyir.com
U2-40    CRUM chip communication error
An error occurs during communication between the MCU and the CRUM chip  copyir.com     CRUM chip abnormality  copyir.com
Developing unit disconnection  copyir.com
MCU PWB abnormality  copyir.com
U9-00    Panel board communication trouble
Communication trouble with the panel board  copyir.com     No command can be sent from the MCU to the panel  copyir.com
U9-80    Panel board communication trouble (Protocol)
An error occurs in communication between MCU -Panel PWB  copyir.com     MCU PWB – Panel PWB harness trouble/ Garbled data  copyir.com
U9-81    Panel board communication trouble (Parity)
A parity error occurs in communication between the MCU and the Panel PWB  copyir.com     MCU PWB – Panel PWB harness trouble/ Garbled data  copyir.com
U9-82    Panel board communication trouble (Overrun)
An overrun error occurs in communication between the MCU and the panel board  copyir.com     MCU PWB – Panel PWB harness trouble/ Garbled data  copyir.com
U9-84    Panel board communication trouble (Framing)
A framing error occurs in communication between the MCU and the Panel PWB  copyir.com     MCU PWB – Panel PWB harness trouble/ Garbled data  copyir.com
U9-88    Panel board communication trouble (Time out)
A time-out error occurs in communication between the MCU and the Panel PWB  copyir.com     A command is completely sent from the MCU to the panel  copyir.com
U9-99    Panel language error
Language discrepancy error  copyir.com     Discrepancy between the machine language and the panel language  copyir.com