A0-01    Security incompatibility error
When the PCL or the FAX control PWB is installed, it does not match with compatible/incompatible setup of the MCU PWB security  copyir.com    The security compatibility/incompatibility of the installed PCL or FAX control PWB does not match with that of the MCU PWB  copyir.com
E1-00    IMC PWB communication trouble
Communication trouble between MCU and IMC PWB    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E1-10    IMC PWB trouble
IMC PWB hardware abnormality    IMC PWB abnormality
E1-11    IMC PWB ASIC error
ASIC abnormality on IMC PWB    IMC PWB abnormality
E1-12    IMC PWB CODEC IC error
CODEC IC (JBIG chip) abnormality on IMC PWB    IMC PWB abnormality
E1-13    IMC PWB flash ROM error
Flash ROM abnormality on IMC PWB    IMC PWB abnormality
E1-14    IMC PWB expanded memory module (DIMM) error
IMC extended compression memory module (DIMM) installation error  copyir.com IMC extended compression memory module (DIMM) access error  copyir.com    IMC expanded memory module installation trouble  copyir.com IMC expanded memory module trouble  copyir.com IMC expanded memory contact trouble  copyir.com IMC PWB abnormality  copyir.com
E1-15    IMC PWB page memory error /SRAM error
IMC PWB page memory or work SRAM access error    IMC PWB abnormality
E1-16    IMC PWB standard compression memory error
Access error of standard compression memory on IMC PWB    IMC PWB abnormality
E1-17    IMC PWB smoothing IC error
IMC PWB smoothing IC abnormality    IMC PWB abnormality
E1-80    IMC PWB communication trouble (protocol)
Communication trouble between MCU and IMC PWB (Protocol error)    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E1-81    IMC PWB communication trouble (Parity)
Communication trouble between MCU and printer IMC (Parity error)    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E1-82    IMC PWB communication trouble (Overrun)
Communication trouble between MCU and IMC PWB (Overrun error)    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E1-84    IMC PWB communication trouble (Framing)
Communication trouble between MCU and IMC PWB (Framing error)    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E1-88    IMC PWB communication trouble (Time-out)
Communication trouble between MCU and IMC PWB (Time-out error)    IMC PWB connector disconnection  copyir.com Motherboard connector pin breakage  copyir.com IMC PWB ROM defect, data failure  copyir.com
E7-02    LSU trouble
BD signal from LSU is not detected in a constant cycle (Kept OFF or ON)    LSU connector or LSU inside harness trouble or disconnection  copyir.com Polygon motor rotation abnormality  copyir.com Laser does not illuminate  copyir.com MCU PWB failure  copyir.com
E7-10    CCD black level error
CCD black reference plate scan level abnormality when the copy lamp turns off  copyir.com    Flat cable installation failure to CCD unit  copyir.com CCD unit error  copyir.com
E7-11    CCD white level error
Improper CCD white reference plate reading level for copy lamp lighting    Flat cable installation failure to CCD unit  copyir.com Dirt on the mirror, lens, and reference white plate  copyir.com Copy lamp lighting trouble  copyir.com CCD unit abnormality  copyir.com MCU PWB abnormality  copyir.com (Occurred in the RSPF scan position)
E7-12    Shading trouble
White correction is not completed in the specified number of times  copyir.com    Flat cable installation failure to CCD unit  copyir.com Dirt on the mirror, lens, and reference  copyir.com white plate  copyir.com Copy lamp lighting trouble  copyir.com CCD unit abnormality  copyir.com MCU PWB abnormality  copyir.com
EE-EL    Developer adjustment trouble (Over-toned abnormality)
An abnormality occurred in execution of automatic developer adjustment  copyir.com Sample data was detected over-toner  copyir.com    Toner concentration sensor abnormality  copyir.com Toner concentration trouble  copyir.com Developing unit trouble  copyir.com MCU PWB failure  copyir.com
EE-EU    Developer adjustment trouble (Undertoned abnormality)
An abnormality occurred in execution of automatic developer adjustment  copyir.com Sample data was detected under-toner  copyir.com    Toner concentration sensor abnormality  copyir.com Toner concentration trouble  copyir.com Developing unit trouble  copyir.com MCU PWB failure  copyir.com
F1-00    Finisher communication trouble
Communication line test error occurs when power is turned on or after the exit of a simulation mode  copyir.com Error in finisher communication    Connection trouble or disconnection of the connector and harness between the body and the finisher  copyir.com Finisher control PWB trouble  copyir.com Control PWB failure  copyir.com Malfunction by noises  copyir.com
F1-03    Delivery roller lift motor trouble
Paper exit roller lift-up motor operation abnormality    Motor lock  copyir.com Motor rpm abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com
F1-10    Staple motor trouble
Staple motor operation abnormality    Motor lock  copyir.com Motor rpm abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com
F1-15    Tray lift motor trouble
The finisher lift-up motor does not reach the specified position    Lift-up motor abnormality  copyir.com Lift-up motor upper limit sensor abnormality  copyir.com Finisher PWB abnormality  copyir.com
F1-19    Paper alignment motor F trouble
Alignment motor operation abnormality    Motor lock  copyir.com Motor rpm abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com
F1-20    Paper alignment motor R trouble
Alignment motor operation abnormality    Motor lock  copyir.com Motor rpm abnormality  copyir.com Overcurrent to the motor  copyir.com Finisher control PWB trouble  copyir.com
F1-37    RAM data trouble
Backup RAM contents are disturbed    Finisher control PWB trouble  copyir.com Malfunction by noise  copyir.com
F1-50    Incompatible trouble
Speed does not coincide between finisher and main unit    Connection of a finisher incompatible with the machine is detected  copyir.com
F1-95    Paper exit option configuration error
An improper option is installed  copyir.com    Configuration of the paper exit option is improperness  copyir.com
F2-02    Toner supply failure
The value judged from the actual toner supply hysteresis differs greatly from the toner sensor value    Developing unit trouble  copyir.com Toner supply abnormality caused by installation of unpacked toner cartridge  copyir.com
F2-04    Identification error Model error Type error Destination error Data abnormality Misc error
(Identification error) When the CRUM trademark differs  copyir.com When the CRUM company code differs  copyir.com
(Model error) When the boot program model code does not match with the CRUM model information
(Type error) When the CRUM type is other than [Genuine/Conversion/Production rotation]
(Destination error) The destination of the body differs from that of the CRUM
(Data abnormality) The initial check information includes an erroneous value  copyir.com When the max  copyir.com toner supply time is 00  copyir.com When the print hard stop is 00    CRUM chip failure  copyir.com Erroneous TNCA  copyir.com
F2-05    CRUM chip communication error    CRUM chip failure  copyir.com Developing unit contact trouble  copyir.com MCU PWB failure  copyir.com
F2-58    Temperature humidity sensor abnormality
Temperature humidity sensor abnormality    Temperature humidity sensor connector disconnection  copyir.com Short-circuit of the temperature humidity sensor was detected  copyir.com
F5-02    Copy lamp (xenon lamp) error
The copy lamp does not light up    Copy lamp abnormality  copyir.com Copy lamp harness abnormality  copyir.com CCD PWB harness abnormality  copyir.com
F6-00    FAX control PWB communication trouble
Communication trouble between MCU and FAX control PWB    FAX control PWB connector disconnection  copyir.com Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-10    FAX control PWB trouble
FAX control PWB abnormality    FAX control PWB defect
F6-80    FAX control PWB communication trouble (Protocol)
Communication trouble between MCU and FAX control PWB (Protocol error)    FAX control PWB connector disconnection Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-81    FAX control PWB communication trouble (Parity)
Communication trouble between MCU and FAX control PWB (Parity error)    FAX control PWB connector disconnection Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-82    FAX control PWB communication trouble (Overrun)
Communication trouble between MCU and FAX control PWB (Overrun error)    FAX control PWB connector disconnection  copyir.com Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-84    FAX control PWB communication trouble (Framing)
Communication trouble between MCU and FAX control PWB (Framing error)    FAX control PWB connector disconnection  copyir.com Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-88    FAX control PWB communication trouble (Time-out)
Communication trouble between MCU and FAX control PWB (Time-out error)    FAX control PWB connector disconnection  copyir.com Harness trouble between FAX control PWB and MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com FAX control PWB ROM defect/Data failure  copyir.com
F6-96    Combination error between the MCU and the FAX firmware  copyir.com
The version of the FAX firmware is not changed “04  copyir.comxx” or later  copyir.com    The version of the FAX firmware is not proper  copyir.com
F6-99    FAX control PWB destination error
The machine destination setup does not coincide with the FAX control PWB destination setup  copyir.com    The machine destination setup (Sim 26-6) does not coincide with the FAX control PWB setup
F9-00    Printer PWB communication trouble
Communication trouble between MCU and printer PWB    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-10    Printer PWB trouble
Printer PWB abnormality    Printer PWB defect
F9-80    Printer PWB communication trouble (Protocol)
Communication trouble between MCU and printer PWB (Protocol error)    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-81    Printer PWB communication trouble (Parity)
Communication trouble between MCU and printer PWB (Parity error)    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-82    Printer PWB communication trouble (Overrun)
Communication trouble between MCU and printer PWB (Overrun error)    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-84    Printer PWB communication trouble (Framing)
Communication trouble between MCU and printer PWB (Framing error)    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-88    Printer PWB communication trouble (Time-out)
Communication trouble between MCU and printer PWB (Time-out error)    Printer PWB connector disconnection  copyir.com Harness trouble between the printer PWB and the MCU PWB  copyir.com Motherboard connector pin breakage  copyir.com Printer PWB ROM defect/Data failure  copyir.com
F9-96    MCU and PCL PWB communication versions discrepancy error
Incompatible PCL PWB was installed to the copier    Different PCL PWB was installed  copyir.com
F9-99    Printer PWB language error
The machine language setup does not coincide with the PCL board language setup  copyir.com    PCL board connection error  copyir.com SIM setup error  copyir.com
H2-00    Main heater lamp thermistor open hard detection
Main heater lamp thermistor open detection  copyir.com Fusing unit not installed  copyir.com    Main thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com Fusing unit not installed  copyir.com
H2-01    Sub heater lamp thermistor open hard detection
Fusing sub thermistor open detection  copyir.com Fusing unit not installed  copyir.com    Sub thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com Fusing unit not installed  copyir.com
H3-00    Main heater lamp abnormally high temperature hard detection trouble
The fusing main heater thermistor causes abnormally high temperature    Main thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com
H3-01    Sub heater lamp abnormally high temperature hard detection trouble
The fusing sub thermistor causes abnormally high temperature    Sub thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com
H3-10    Main heater lamp abnormally high temperature soft detection trouble
A/D value the fusing main thermistor causes abnormally high temperature (over 230°C)  copyir.com    Main heater lamp thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com
H3-11    Sub heater lamp abnormally high temperature soft detection trouble
A/D value the fusing sub heater lamp thermistor causes abnormally high temperature (over 230°C)  copyir.com    Sub heater lamp thermistor defect  copyir.com Control PWB failure  copyir.com Fusing section connector contact failure  copyir.com
H4-00    Main heater lamp abnormally low temperature detection
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power  copyir.com When the temperature of main heater lamp thermistor falls below 140°C in the standby mode or printing  copyir.com When the temperature of main heater lamp thermistor falls below 50°C in the pre-heat mode  copyir.com    Main heater lamp thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
H4-01    Sub heater lamp abnormally low temperature detection
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power  copyir.com When the temperature of sub heater thermistor falls below 140°C in the standby mode or printing  copyir.com When the temperature of sub heater lamp thermistor falls below 50°C in the pre-heat mode  copyir.com    Sub heater lamp thermistor defect  copyir.com Sub heater lamp failure  copyir.com Sub thermostat failure  copyir.com Control PWB failure  copyir.com
H4-20    Main heater lamp abnormally low temperature detection
The setup temperature (about –25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power  copyir.com A/D value of fusing main thermistor is not reached within the specified temperature  copyir.com (specified temperature : SIM43-1 (600dpi) –25°C )    Main thermistor defect  copyir.com Main heater lamp failure  copyir.com Main thermostat failure  copyir.com Control PWB failure  copyir.com
H4-21    Sub heater lamp abnormally low temperature detection
The setup temperature (about –25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power  copyir.com A/D value of fusing sub thermistor is not reached within the specified temperature (specified temperature : SIM43-1 (600dpi) –25°C )    Sub thermistor defect  copyir.com Sub heater lamp failure  copyir.com Sub thermostat failure  copyir.com Control PWB failure  copyir.com
H5-01    10 times of continuous detection of the lower paper exit sensor (POD1) lead edge jam or the upper paper exit sensor (POD2) lead edge jam or the duplex sensor (PPD2) rear edge jam
After supplying the power, one of the above jams occurs 10 times continuously in printing Counting is started on supplying the power  copyir.com When any one of the above jams occurs, one count is made  copyir.com When paper entry to the POD1 or POD2 is detected, the counter is cleared  copyir.com    A paper jam (paper rounding, etc  copyir.com) near the duplex sensor (PPD2) on the fusing unit is not canceled completely  copyir.com POD1, POD2, PPD2 sensor breakdown or harness connection trouble Fusing unit installation failure
L1-00    Scanner feed trouble
Scanner feed is not completed within the specified time  copyir.com    Mirror unit defect  copyir.com Scanner wire disconnection  copyir.com Origin detection sensor error  copyir.com Mirror motor harness abnormality  copyir.com
L3-00    Scanner return trouble
Scanner return is not completed within the specified time  copyir.com When OC copying with the mirror at the home position, the mirror is not in the home position  copyir.com    Mirror unit defect  copyir.com The scanner wire is disconnected  copyir.com Origin detection sensor error  copyir.com Mirror motor harness abnormality  copyir.com
L4-01    Main motor trouble
The main motor does not rotate  copyir.com The motor lock signal is detected for 1sec or more after the main motor rotates  copyir.com The motor lock signal is detected for 1sec during rotation of the main motor  copyir.com    Main motor defect  copyir.com Main motor connection, harness trouble or disconnection  copyir.com MCU PWB failure  copyir.com
L4-11    Shifter motor trouble
The shifter home position detection signal is not detected when the shifter is operating  copyir.com    Shifter motor trouble or harnes connection trouble and disconnection  copyir.com Shifter home position sensor trouble  copyir.com
L4-31    Fusing fan lock trouble
Fusing fan does not rotate  copyir.com The fusing fan lock signal is detected for 1sec or more  copyir.com    Fusing fan connection trouble, harness disconnection  copyir.com MCU PWB failure  copyir.com
L4-32    Power fan lock trouble
Exhaust/intake fan motor does not rotate  copyir.com The fan lock signal is detected for 1sec or more  copyir.com    Fan connection trouble, harness disconnection  copyir.com MCU PWB failure  copyir.com
L4-33    Paper exit fan lock trouble
Paper exit fan does not rotate  copyir.com The paper exit fan lock signal is detected for 1sec or more  copyir.com    Paper exit fan connection trouble, harness disconnection  copyir.com MCU PWB failure  copyir.com
L6-10    Polygon motor lock trouble
The polygon motor does not rotate  copyir.com The motor lock signal is detected for 6sec or more after the polygon motor rotates  copyir.com The motor lock signal is detected for 1sec during rotation of the polygon motor  copyir.com    Polygon motor unit failure Polygon motor connection, harness trouble or disconnection MCU PWB failure
L8-10    Power abnormality detection trouble
The power status monitoring signal keeps power OFF state after passing the specified time (2sec)  copyir.com    Circuit around the power status monitoring signal (PSSTS) failure  copyir.com
PF-00    PF trouble
The copy inhibit command from RIC is received  copyir.com    Judged by the host  copyir.com
U1-01    FAX battery error
The SRAM backup battery voltage on FAX control PWB falls  copyir.com    The SRAM backup battery voltage on FAX control PWB falls  copyir.com
U1-02    PANEL LOW battery error
The voltage of the panel clock function battery falls  copyir.com    The voltage of the panel clock function battery falls  copyir.com
U2-04    EEPROM communication error
EEPROM communication error    EEPROM defect  copyir.com ICU PWB EEPROM access circuit failure  copyir.com
U2-20    Machine speed code data error
The machine boot speed information is not identical to the model code speed information    EEPROM defect  copyir.com SIM operation error  copyir.com
U7-00    RIC communication trouble
Error in communication with RIC  copyir.com Error in communication test after turning on the power or canceling SIM  copyir.com    Connector harness contact trouble or disconnection  copyir.com RIC control PWB trouble  copyir.com MCU PWB failure  copyir.com Malfunction by noises  copyir.com
U9-00    Operation control PWB communication trouble
Communication trouble between MCU and the operation control PWB    Operation control PWB connector disconnection Harness failure of the operation control PWB and the MCU PWB
U9-80    Operation control PWB communication trouble (Protocol)
Communication trouble between MCU and the operation control PWB (Protocol error)    Operation control PWB connector disconnection  copyir.com Harness failure of the operation control  copyir.com PWB and the MCU PWB  copyir.com
U9-81    Operation control PWB communication trouble (Parity)
Communication trouble between MCU and the operation control PWB (Parity error)    Operation control PWB connector disconnection  copyir.com Harness failure of the operation control PWB and the MCU PWB  copyir.com
U9-82    Operation control PWB communication trouble (Overrun)
Communication trouble between MCU and the operation control PWB (Overrun error)    Operation control PWB connector disconnection  copyir.com Harness failure of the operation control PWB and the MCU PWB  copyir.com
U9-84    Operation control PWB communication trouble (Framing)
Communication trouble between MCU and the operation control PWB (Framing error)    Operation control PWB connector disconnection  copyir.com Harness failure of the operation control PWB and the MCU PWB  copyir.com
U9-88    Operation control PWB communication trouble (Time-out)
Communication trouble between MCU and the operation PWB (Time-out error)    Operation control PWB connector disconnection  copyir.com Harness failure of the operation control PWB and the MCU PWB  copyir.com
U9-99    Operation panel destination error
An error occurred in checking the destination of the operation panel and the main body  copyir.com    Erroneous connection the operation panel unit  copyir.com SIM setup error  copyir.com

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید