A0-01    Security incompatibility error
When the PCL or the FAX board is installed, it does not match with compatible/incompatible setup of the MCU board security  copyir.com     The security compatibility/incompatibility of the installed PCL or FAX board does not match with that of the MCU board  copyir.com
E1-00    MCU-IMC communication trouble
Communication establishment error/ framing/parity/protocol error    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-10    IMC PWB trouble
Communication trouble between MCU and IMC PWB    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-11    IMC board ASIC error
ASIC abnormality on IMC board    IMC board abnormality
E1-12    IMC board CODEC IC error
CODEC IC (JBIG chip) abnormality on IMC board    IMC board abnormality
E1-13    IMC board flash ROM error
Flash ROM abnormality on IMC board    IMC board abnormality
E1-14    IMC board expanded memory module (DIMM) error
IMC extended compression memory module installation error IMC extended compression memory access error    IMC expanded memory module installation trouble IMC expanded memory module trouble IMC expanded memory contact trouble IMC board abnormality
E1-15    IMC board Page Memory error/SRAM error
IMC Page Memory Work SRAM abnormality    IMC board abnormality
E1-16    IMC board compression image store memory error
Access error of IMC standard compression memory    IMC board abnormality
E1-17    IMC board smoothing IC error
IMC smoothing IC abnormality    IMC board abnormality
E1-80    IMC PWB communication trouble (protocol)
Communication trouble between MCU and IMC PWB (Protocol error)    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-81    IMC PWB communication trouble (Parity)
Communication trouble between MCU and printer IMC (Parity error)    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-82    IMC PWB communication trouble (Overrun)
Communication trouble between MCU and IMC PWB (Overrun error)    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-84    IMC PWB communication trouble (Framing)
Communication trouble between MCU and IMC PWB (Framing error)    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E1-88    IMC PWB communication trouble (Timeout)
Communication trouble between MCU and IMC PWB (Time-out error)    IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
E7-02    LSU trouble
BD signal from LSU is not detected in a constant cycle  copyir.com  (Kept OFF or ON)    LSU connector or LSU inside harness trouble or disconnection Polygon motor rotation abnormality Laser does not illuminate  copyir.com  MCU PWB failure
E7-10    Shading trouble (black correction)
CCD black reference plate scan level abnormality when the copy lamp turns off  copyir.com     Flat cable installation failure to CCD unit CCD unit error
E7-11    Shading trouble (white correction)
Improper CCD white reference plate reading level for copy lamp lighting    Flat cable installation failure to CCD unit “Dirt on the mirror, lens, and reference white plate” Copy lamp operation error CCD unit abnormality MCU PWB abnormality (Occurred in the SPF scan position  copyir.com )
E7-12    Shading trouble
White correction is not completed in the specified number of times  copyir.com     Flat cable installation failure to CCD unit “Dirt on the mirror, lens, and reference white plate” Copy lamp lighting trouble CCD unit abnormality MCU PWB abnormality
EE-EL    Developer adjustment trouble (Over-toned abnormality)
An abnormality occurred in execution of automatic developer adjustment  copyir.com  Sample data was detected over-toner  copyir.com     Toner concentration sensor abnormality Toner concentration trouble Developing unit trouble MCU PWB failure
EE-EU    Developer adjustment trouble (Undertoned abnormality)
An abnormality occurred in execution of automatic developer adjustment  copyir.com  Sample data was detected under-toner  copyir.com     Toner concentration sensor abnormality Toner concentration trouble Developing unit trouble MCU PWB failure
F1-00    Finisher communication trouble
Communication line test error occurs when power is turned on or after the exit of a simulation mode  copyir.com  Error in Finisher communication    Connection trouble or disconnection of the connector and harness between the body and the finisher  copyir.com  Finisher control PWB trouble Control PWB failure Malfunction by noises
F1-01    Side guide plated home position error
The side guide plate cannot return to the home position  copyir.com     Side guide plate drive motor abnormality Side guide plate home position sensor abnormality Finisher PWB abnormality
F1-06    Offset motor trouble
When the offset motor of the finisher is driven it does not reach the specified position  copyir.com     Offset motor abnormality Offset motor origin sensor abnormality Finisher PWB abnormality
F1-08    Staple motor error
The staple motor cannot return to the home position  copyir.com     Staple motor abnormality Staple motor home position sensor abnormality Staple unit abnormality Finisher PWB abnormality
F1-11    Rear edge plate home position error
The rear edge plate cannot return to the home position  copyir.com     Rear edge plate drive motor abnormality Side guide plate home position sensor abnormality Finisher PWB abnormality
F1-15    Finisher lift-up motor trouble
The finisher lift-up motor does not reach the specified position  copyir.com     Lift-up motor abnormality Lift-up motor upper limit sensor abnormality Finisher PWB abnormality
F2-02    Toner supply failure
The value judged from the actual toner supply hysteresis differs greatly from the toner sensor value  copyir.com     Developing unit trouble Toner supply abnormality caused by installation of unpacked toner cartridge
F2-04    Identification error
Identification error When the CRUM trademark differs  copyir.com  When the CRUM company code differs  copyir.com     CRUM chip failure Erroneous developing unit
F5-02    Copy lamp lighting abnormality
The copy lamp does not light up  copyir.com     Copy lamp error Copy lamp harness abnormality CCD PWB harness abnormality
F6-00    MCU-FAX communication trouble
Communication establishment error/ framing/parity/protocol error    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-10    FAX control PWB trouble
Communication trouble between MCU and FAX control PWB    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error IC on FAX PWB causes abnormality
F6-80    FAX control PWB communication trouble (Protocol)
Communication trouble between MCU and FAX control PWB (Protocol error)    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-81    FAX control PWB communication trouble (Parity)
Communication trouble between MCU and FAX control PWB (Parity error)    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-82    FAX control PWB communication trouble (Over-run)
Communication trouble between MCU and FAX control PWB (Overrun error)    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-84    FAX control PWB communication trouble (Framing)
Communication trouble between MCU and FAX control PWB (Framing error)    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-88    FAX control PWB communication trouble (Timeout)
Communication trouble between MCU and FAX control PWB (Timeout error)    FAX control PWB connector disconnection Defective harness between FAX control PWB and MCU PWB Motherboard connector pin breakage FAX control PWB ROM error/Data error
F6-99    FAX control PWB destination error
The machine destination setup does not coincide with the FAX board destination setup  copyir.com     The machine destination setup (Sim 26-6) does not coincide with the FAX board setup
F9-00    MCU-PRT communication trouble
Communication establishment error/ framing/parity/protocol error    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-10    Printer PWB trouble
Communication trouble between MCU and printer PWB    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-80    Printer PWB communication trouble (Protocol)
Communication trouble between MCU and printer PWB (Protocol error)    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-81    Printer PWB communication trouble (Parity)
Communication trouble between MCU and printer PWB (Parity error)    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-82    Printer PWB communication trouble (Overrun)
Communication trouble between MCU and printer PWB (Overrun error)    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-84    Printer PWB communication trouble (Framing)
Communication trouble between MCU and printer PWB (Framing error)    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-88    Printer PWB communication trouble (Timeout)
Communication trouble between MCU and printer PWB (Timeout error)    Printer PWB connector disconnection Harness trouble between the printer PWB and the MCU PWB Motherboard connector pin breakage Printer PWB ROM trouble/Data disturbance
F9-99    Machine-PCL board language error
The machine language setup does not coincide with the PCL board language setup  copyir.com     PCL board connection error SIM setup error
H2-00    Main heater lamp thermistor open hard detection
Main heater lamp thermistor open detection Fusing unit not installed    Thermistor defect Control PWB failure Fusing section connector contact failure Fusing unit not installed
H2-01    Sub heater lamp thermistor open hard detection
Sub heater lamp thermistor open detection Fusing unit not installed    Thermistor defect Control PWB failure Fusing section connector contact failure Fusing unit not installed
H3-00    Main heater lamp abnormally high temperature hard detection trouble
The fusing main heater thermistor causes abnormally high temperature  copyir.com     Main heater lamp thermistor defect Control PWB failure Fusing section connector contact failure
H3-01    Sub heater lamp abnormally high temperature hard detection troubl
The fusing sub heater thermistor causes abnormally high temperature  copyir.com     Sub heater lamp Thermistor defect Control PWB failure Fusing section connector contact failure
H3-10    Main heater lamp abnormally high temperature soft detection trouble
A/D value the fusing main heater lamp thermistor causes abnormally high temperature (over 230°C)  copyir.com     Main heater lamp thermistor defect Control PWB failure Fusing section connector contact failure
H3-11    Sub heater lamp abnormally high temperature soft detection trouble
A/D value the fusing sub heater lamp thermistor causes abnormally high temperature (over 230°C)  copyir.com     Sub heater lamp thermistor defect Control PWB failure Fusing section connector contact failure
H4-00    Main heater lamp abnormally low temperature detection
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW  copyir.com  (When the temperature of main heater lamp thermistor falls below 140°C in the standby mode or printing  copyir.com ) Whether temperature of main heater lamp thermistor falls below 50°C in the pre-heat mode  copyir.com     Main heater lamp thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
H4-01    Sub heater lamp abnormally low temperature detection
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW  copyir.com  (When the temperature of sub heater thermistor falls below 140°C in the standby mode or printing  copyir.com ) Whether temperature of sub heater lamp thermistor falls below 50°C in the pre-heat mode  copyir.com     Sub heater lamp thermistor defect Sub heater lamp failure Sub thermostat failure Control PWB failure
H4-20    Main heater lamp abnormally low temperature detection
The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW  copyir.com  (When the temperature falls below 140°C in the standby mode  copyir.com )    Main heater thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
H4-21    Sub heater lamp abnormally low temperature detection
The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW  copyir.com  (When the temperature falls below 140°C in the standby mode  copyir.com )    Sub heater thermistor defect Sub heater lamp failure Sub thermostat failure Control PWB failure
H5-01    10 continuous POD1, POD2 or PPD2 JAM
POD1, POD2, PPD2 JAM was detected 10 continuous times from turning on the power ON  copyir.com     The fusing JAM is not completely removed  copyir.com  (Jam paper remains  copyir.com ) POD1, POD2, PPD2 sensor breakdown or harness connection trouble Fusing unit installation failure
L1-00    Scanner feed trouble
Scanner feed is not completed within the specified time  copyir.com     Mirror unit defect Scanner wire disconnection Origin detection sensor error Mirror motor harness abnormality
L3-00    Scanner return trouble
Scanner return is not completed within the specified time  copyir.com  “When OC copying with the mirror at the home position, the mirror is not in the home position  copyir.com  ”    Mirror unit defect The scanner wire is disconnected  copyir.com  Origin detection sensor error Mirror motor harness abnormality
L4-01    Main motor trouble
The main motor does not rotate  copyir.com  The motor lock signal is detected for 1sec or more after the main motor rotates  copyir.com  The motor lock signal is detected for 1sec during rotation of the main motor  copyir.com     Main motor defect Main motor connection, harness trouble or disconnection MCU PWB failure
L4-11    Shifter motor trouble
The shifter home position detection signal is not detected when the shifter is operating  copyir.com     Shifter motor trouble or harness connection trouble and disconnection Shifter home position sensor trouble
L6-10    Polygon motor lock trouble
The polygon motor does not rotate  copyir.com  The motor lock signal is detected for 6sec or more after the polygon motor rotates  copyir.com  The motor lock signal is detected for 1sec during rotation of the polygon motor  copyir.com     Polygon motor unit failure Polygon motor connection, harness trouble or disconnection MCU PWB failure
L8-10    Power abnormality detection trouble
The power status monitoring signal keeps power OFF state after passing the specified time (2sec)  copyir.com     Circuit around the power status monitoring signal failure  copyir.com
PF-00    RIC communication error
The copy inhibit command from RIC is received  copyir.com     Judged by the host  copyir.com
U1-01    FAX battery error
The SRAM backup battery voltage on FAX PWB falls  copyir.com     The SRAM backup battery voltage on FAX PWB falls  copyir.com
U1-02    PANEL LOW battery error
The voltage of the panel clock function battery falls  copyir.com     The voltage of the panel clock function battery falls  copyir.com
U2-04    EEPROM communication error
MCU PWB EEPROM access circuit failure    EEPROM defective ICU PWB EEPROM access circuit failure
U2-20    Machine speed code data error
The machine (Boot) speed information is not identical to the model code speed information  copyir.com     EEPROM defective SIM operation error
U2-40    CRUM chip communication error
Error in MCU-CRUM chip communication    CRUM chip failure Developing unit contact trouble MCU PWB failure
U7-00    RIC communication trouble
Error in communication with RIC Error in communication test after turning on the power or canceling SIM  copyir.com     Connector harness contact trouble or disconnection RIC control PWB trouble MCU PWB failure Malfunction by noises
U9-00    MCU-OPE communication trouble
Communication establishment error/ framing/parity/protocol error    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-80    Operation control PWB communication trouble (Protocol)
Communication trouble between MCU and the operation control PWB (Protocol error)    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-81    Operation control PWB communication trouble (Parity)
Communication trouble between MCU and the operation control PWB (Parity error)    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-82    Operation control PWB communication trouble (Overrun)
Communication trouble between MCU and the operation control PWB (Overrun error)    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-84    Operation control PWB communication trouble (Framing)
Communication trouble between MCU and the operation control PWB (Framing error)    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-88    Operation control PWB communication trouble (Time-out)
Communication trouble between MCU and the operation PWB (Time-out error)    Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
U9-99    Operation panel destination error
An error occurred in checking the destination of the operation panel and the main body  copyir.com     Erroneous connection the operation panel unit SIM setup error

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید