ایرادات دستگاهای شارپ براساس کد می باشد شرکت کپی ایران در نظر داردتمامی سرویس منالها و رفع ایرادادت را در اختیار شما عزیزان قرار دهد
A0-30 Machine configuration error IFAX modem PWB is not connected properly FAX modem PWB is broken Wireless LAN PWB is not connected properly Wireless LAN PWB is broken RSPF/SPF is not connected properly RSPF/SPF is broken Check connection of FAX modem PWB Replace FAX modem PWB Check connection of LAN PWB Replace LAN PWB Check connection of RSPF/SPF Replace RSPF/SPF
C1-10 Main charger trouble (BK) The main charger unit (BK, C, M, Y) is not installed properly copyir.com There is an abnormality in the main charger unit (BK, C, M, Y) copyir.com Disconnection of the high voltage PWB connector copyir.com Breakage of the high voltage harness copyir.com DV PWB trouble copyir.com MFP PWB trouble Check the output of the main charger with SIM8-2 copyir.com Check disconnection of the main charger copyir.com/Replace copyir.com Check disconnection of the high voltage PWB copyir.com connector copyir.com /Replace copyir.com Replace the DV PWB copyir.com Replace the MFP PWB copyir.com
E7-01 MFP image data error Image data transfer error in the MFP PWB copyir.com MFP PWB trouble copyir.com Check connection of the connector and the harness of the MFP PWB copyir.com Replace the MFP PWB copyir.com
E7-10 Shading error (Black correction) Abnormality in the CIS black scan level when the copy lamp is turned OFF copyir.com Improper installation of the harness to the CIS unit/ MFP PWB copyir.com Improper installation of the harness to the CIS unit/ AFE PWB copyir.com Improper installation of the harness to the MFP PWB/AFE PWB copyir.com CIS unit abnormality copyir.com AFE PWB abnormality copyir.com MFP PWB abnormality copyir.com Check connection of the harness to the CIS unit/ MFP PWB copyir.com Check connection of the harness to the CIS unit/ AFE PWB copyir.com Check connection of the harness to the AFE PWB/ MFPWB copyir.com Check the CIS unit copyir.com Check the AFE PWB copyir.com Check the MFP PWB copyir.com
E7-11 Shading error (White correction) Abnormality in the CIS white reference plate scan level when the scanner lamp is turned ON copyir.com Improper installation of the harness to the CIS unit/ MFP PWB copyir.com Improper installation of the harness to the CIS unit/ AFE PWB copyir.com Improper installation of the harness to the MFP PWB/AFE PWB copyir.com Dirt on the mirror, lens, and the reference white plate copyir.com Copy lamp lighting trouble copyir.com CIS unit abnormality copyir.com AFE PWB abnormality copyir.com MFP PWB abnormality copyir.com Check connection of the harness to the CIS unit/ MFP PWB copyir.com Check connection of the harness to the CIS unit/ AFE PWB copyir.com Check connection of the harness to the MFP PWBAFE PWB copyir.com Check connection of the harness to the Copy lamp unit copyir.com Clean the mirror, the lens, and the reference white plate copyir.com Check the CIS unit copyir.com Check the AFE PWB copyir.com Check the MFP PWB
E7-14 CIS-ASIC error MFP PWB trouble copyir.com AFE PWB trouble copyir.com MFP PWB trouble copyir.com Improper installation of the harness to the MFP PWB/AFE PWB copyir.com Check the MFP PWB copyir.com Replace the MFP PWB copyir.com Check the AFE PWB copyir.com Replace the AFE PWB copyir.com Check connection of the harness to the AFE PWB/ MFP PWB copyir.com
E7-20 LSU BD(KC) detection error / LSU LD deform error (K) Optical axis shift copyir.com Reduced laser power, lighting error, laser diode trouble copyir.com BD PWB trouble copyir.com Harness and connector trouble between the LD/ BD(KC) PWB and the LSUcnt PWB copyir.com Use SIM61-1 to check the operation of the LSU copyir.com Check the PWB and connection of the harness in the LSU copyir.com Replace the LSU copyir.com
E7-21 LSU LD deform error (C) Reduced laser power, lighting error, laser diode trouble copyir.com Harness and connector trouble between the LD PWB and the LSUcnt PWB copyir.com Use SIM61-1 to check the operation of the LSU copyir.com Check the PWB and connection of the harness in the LSU copyir.com Replace the LSU copyir.com
E7-22 LSU LD deform error (M) Reduced laser power, lighting error, laser diode trouble copyir.com Harness and connector trouble between the LD PWB and the LSU cnt PWB copyir.com Use SIM61-1 to check the operation of the LSU copyir.com Check the PWB and connection of the harness in the LSU copyir.com Replace the LSU copyir.com
E7-23 LSU BD(MY) detection error / LSU LD deform error (K) Optical axis shift copyir.com Reduced laser power, lighting error, laser diode trouble copyir.com Harness and connector trouble between the LD(MY) PWB and the LSU cnt PWB copyir.com Use SIM61-1 to check the operation of the LSU copyir.com Check the PWB and connection of the harness in the LSU copyir.com Replace the LSU copyir.com
E7-28 LSU-MFP connection error Communication error between the CPU in the MFP PWB and the control ASIC copyir.com Improper connection of the communication connector between the MFP PWB and the LSU cnt PWB copyir.com Harness trouble between the MFP PWB and the LSU cnt PWB MFP PWB or LSU cnt PWB trouble Check connection of the connector and the harness between the MFP PWB and the LSU cnt PWB copyir.com Replace the LSU PWB copyir.com Replace the MFP PWB copyir.com
E7-29 LSU ASIC frequency error Oscillation abnormality of the external oscillator and the internal oscillating circuit used in the LSU ASIC copyir.com LSU ASIC abnormality on the LSUcnt PWB copyir.com Check connection of the connector and the harness between the MFP PWB and the LSUcnt PWB copyir.com Replace the MFP PWB copyir.com Replace the LSU copyir.comPWB copyir.com
E7-38 Zoran chip AD adjustment error The voltage on MFPC PWB is not stable The parts on the MFPC PWB are not soldered properly copyir.com Replace the MFPC PWB copyir.com
E7-80 Flex RISC- SCU communication error FlexRISC trouble Check fixation of the MFPC PWB Replace the MFPC PWB copyir.com
E7-91 FAX reception image data error FAX control PWB trouble Image data process abnormality Flash memory contact error Image compression data corruption Control PWB trouble Replace the fax control PWB Sim60-1 to check the read/write operations of the memory Replace the MFPC PWB
E7-93 Copy, image send, FAX, filing, print image data process error Image compression data corruption Image data process abnormality Control PWB trouble Replace the mother board copyir.com Sim60-1 to check the read/write operations of the memory Replace the MFPC PWB
EE-EC Automatic toner density adjustment error (Sampling level 76 – 117/139 – 178) Toner density sensor trouble copyir.com Developing unit trouble copyir.com PCU PWB trouble copyir.com Replace the toner density sensor copyir.com Replace the developing unit copyir.com Replace the PCU PWB copyir.com
EE-EL Automatic toner density adjustment error (Overtoner) Toner density sensor trouble copyir.com Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble copyir.com MFPC PWB trouble copyir.com Replace the toner density sensor copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
EE-EU Automatic toner density adjustment error (Undertoner) Toner density sensor trouble copyir.com Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble copyir.com PCU PWB trouble copyir.com Replace the toner density sensor copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
F2-22 Discharge lamp trouble (K) Contact trouble between the discharge lamp PWB (K) and the MFPC PWB copyir.com Discharge lamp PWB (K) trouble copyir.com MFPC PWB trouble copyir.com Replace the discharge lamp PWB (K) copyir.com Check the harness and the connector copyir.com Replace the MFPC PWB copyir.com
F2-23 Discharge lamp trouble (CMY) Contact trouble between the discharge lamp PWB (C) and the PCU PWB copyir.com Discharge lamp PWB (C) trouble copyir.com MFPC PWB trouble copyir.com Replace the discharge lamp PWB (C) copyir.com Check the harness and the connector copyir.com Replace the MFPC PWB copyir.com
F2-39 Process thermister trouble Process thermister trouble copyir.com Process thermister harness connection trouble copyir.com MFPC PWB trouble Replace the process thermister copyir.com Check connection of the harness and the connector copyir.com Replace the MFPC PWB copyir.com
F2-40 Toner density sensor trouble (BLACK) Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness copyir.com Developing unit trouble copyir.com MFPC PWB trouble Replace the toner density sensor copyir.com Harness and connector connection trouble copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
F2-41 Toner density sensor trouble (CYAN) Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness copyir.com Developing unit trouble copyir.com MFPC PWB trouble Replace the toner density sensor copyir.com Harness and connector connection trouble copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
F2-42 Toner density sensor trouble (MAGENTA) Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness copyir.com Developing unit trouble copyir.com MFPC PWB trouble Replace the toner density sensor copyir.com Harness and connector connection trouble copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
F2-43 Toner density sensor trouble (YELLOW) Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) copyir.com Connection trouble of the connector and the harness copyir.com Developing unit trouble copyir.com MFPC PWB trouble copyir.com Replace the toner density sensor copyir.com Harness and connector connection trouble copyir.com Replace the developing unit copyir.com Replace the MFPC PWB copyir.com
F2-45 K image density sensor trouble K image density sensor sensitivity adjustment trouble copyir.com K image density sensor trouble copyir.com Harness and connector connection trouble copyir.com K image density sensor dirt copyir.com Calibration plate dirt copyir.com Calibration plate solenoid trouble copyir.com MFPC PWB trouble copyir.com Replace the K image density sensor copyir.com Check connection of the connectors and the harness copyir.com Clean the K image density sensor copyir.com Replace the calibration plate copyir.com Replace the calibration plate solenoid copyir.com Replace the PCU PWB copyir.com Use SIM44-2 to adjust the process control sensor sensitivity copyir.com
F2-47 Ozon duct thermister trouble The ozone duct thermister trouble copyir.com Harness and connector connection trouble between the ozone duct thermistor and the MFPC PWB copyir.com MFPC PWB trouble copyir.com Check connection of the connectors and the harness between the ozone duct thermistor and the MFPC PWB copyir.com Replace the MFPC PWB copyir.com
F2-49 LSU thermister trouble The LSU detection temperature is outside of -28C – 78C copyir.com LSU thermister trouble copyir.com Harness and connector connection trouble copyir.com MFP PWB trouble LSU control PWB trouble copyir.com Check connection of the connectors and the harness copyir.com Replace the MFPC PWB copyir.com Replace the LSU copyir.com
F2-50 K drum phase sensor trouble Drum phase sensor trouble copyir.com Harness and connector connection trouble copyir.com Drum drive section trouble copyir.com MFPC PWB trouble Use SIM30-1 to check the operation of “DHPD_K copyir.com” copyir.com Replace the drum phase sensor copyir.com Check connection of the connectors and the harness copyir.com Repair the drum drive section copyir.com Replace the MFPC PWB copyir.com
F2-51 CL drum phase sensor trouble Drum phase sensor trouble copyir.com (DHPCL) Harness and connector connection trouble copyir.com Drum drive section trouble copyir.com MFPC PWB trouble copyir.com Use SIM30-1 to check the operation of “DHPD_CL” copyir.com Replace the drum phase sensor copyir.com Check connection of the connectors and the harness copyir.com Repair the drum drive section copyir.com Replace the MFPC PWB copyir.com
F2-58 Process humidity sensor trouble Process humidity sensor trouble copyir.com Harness and connector connection trouble copyir.com PMFPC PWB trouble copyir.com Replace the process humidity sensor copyir.com Check connection of the connectors and the harness copyir.com Replace the MFPC PWB copyir.com
F2-64 Toner supply operation trouble (BK) Toner motor trouble copyir.com Toner drive clutch trouble copyir.com Toner density sensor trouble copyir.com Connector/harness trouble copyir.com MFPC PWB trouble copyir.com Toner cartridge trouble copyir.com Developing unit trouble copyir.com Replace the toner motor copyir.com Replace the toner drive clutch copyir.com Replace the toner density sensor copyir.com Connector/harness trouble copyir.com Replace the MFPC PWB copyir.com Replace the toner cartridge copyir.com Replace the developing unit copyir.com
F2-65 Toner supply operation trouble (C) Toner motor trouble copyir.com Toner drive clutch trouble copyir.com Toner density sensor trouble copyir.com Connector/harness trouble copyir.com MFPC PWB trouble Toner cartridge trouble copyir.com Developing unit trouble copyir.com Replace the toner motor copyir.com Replace the toner drive clutch copyir.com Replace the toner density sensor copyir.com Connector/harness trouble copyir.com Replace the MFPC PWB copyir.com Replace the toner cartridge copyir.com Replace the developing unit copyir.com
F2-66 Toner supply operation trouble (M) Toner motor trouble copyir.com Toner drive clutch trouble copyir.com Toner density sensor trouble copyir.com Connector/harness trouble copyir.com MFPC PWB trouble Toner cartridge trouble copyir.com Developing unit trouble copyir.com Replace the toner motor copyir.com Replace the toner drive clutch copyir.com Replace the toner density sensor copyir.com Connector/harness trouble copyir.com Replace the MFPC PWB copyir.com Replace the toner cartridge copyir.com Replace the developing unit copyir.com
F2-67 Toner supply operation trouble (Y) Toner motor trouble copyir.com Toner drive clutch trouble copyir.com Replace the toner drive clutch copyir.com Toner density sensor trouble copyir.com Connector/harness trouble copyir.com MFPC PWB trouble Toner cartridge trouble copyir.com Developing unit trouble copyir.com Replace the toner motor copyir.com Replace the toner density sensor copyir.com Connector/harness trouble copyir.com Replace the MFPC PWB copyir.com Replace the toner cartridge copyir.com Replace the developing unit copyir.com
F2-70 Improper toner cartridge detection (BK) An improper toner cartridge is inserted copyir.com (The main unit detects a toner cartridge of a different specification copyir.com) Toner cartridge trouble copyir.com MFPC PWB trouble Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com
F2-71 Improper toner cartridge detection (C) An improper toner cartridge is inserted copyir.com (The main unit detects a toner cartridge of a different specification copyir.com) Toner cartridge trouble copyir.com MFPC PWB trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com
F2-72 Improper toner cartridge detection (M) An improper toner cartridge is inserted copyir.com (The main unit detects a toner cartridge of a different specification copyir.com) Toner cartridge trouble copyir.com MFPC PWB trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com
F2-73 Improper toner cartridge detection (Y) An improper toner cartridge is inserted copyir.com (The main unit detects a toner cartridge of a different specification copyir.com) Toner cartridge trouble copyir.com MFPC PWB trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com
F2-74 Toner cartridge CRUM error (BK) Toner cartridge (CRUM) trouble copyir.com MFPC PWB trouble copyir.com Connector/harness trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com Connector/harness trouble copyir.com
F2-75 Toner cartridge CRUM error (C) Toner cartridge (CRUM) trouble copyir.com MFPC PWB trouble copyir.com Connector/harness trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com Connector/harness trouble copyir.com
F2-76 Toner cartridge CRUM error (M) Toner cartridge (CRUM) trouble copyir.com MFPC PWB trouble copyir.com Connector/harness trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com Connector/harness trouble copyir.com
F2-77 Toner cartridge CRUM error (Y) Toner cartridge (CRUM) trouble copyir.com MFPC PWB trouble copyir.com Connector/harness trouble copyir.com Replace the toner cartridge copyir.com Replace the MFPC PWB copyir.com Connector/harness trouble copyir.com
F3-22 Paper feed tray 2 lift operation trouble LUD1 is not turned ON within the specified time copyir.com C2LUD1sensor trouble Paper feed tray 2 lift unit trouble copyir.com MFPC PWB trouble copyir.com Harness and connector connection trouble copyir.com Check connection of the harness and the connector of C2LUD copyir.com Replace the lift-up unit copyir.com Replace the MFPC PWB copyir.com
F6-00 Controller – FAX communication trouble
MFP – FAX communication establishment error / Framing / Parity / Protocol error FAX control PWB trouble copyir.com FAX control PWB – MFPC PWB connector and harness trouble copyir.com FAX PWB trouble copyir.com FAX PWB trouble copyir.com Replace the FAX control PWB copyir.com Check the connector and the harness between the FAX control PWB and the MFPC PWB copyir.com Check/Replace the FAX PWB (The modem chip is not soldered correctly) copyir.com Check/Replace the FAX PWB (The modem chip is not soldered correctly)
F6-04 FAX MODEM operation trouble copyir.com
FAX control PWB MODEM chip operation trouble FAX MODEM chip operation trouble copyir.com The FAX MODEM chip cannot be accessed copyir.com Replace the FAX control PWB copyir.com Replace the FAX control PWB copyir.com
F6-21 Improper combination of FAX PWB and FAX soft switch
Incompatibility between the FAX PWB and the FAX control PWB information (soft switch) The destination of the FAX PWB installed is improper copyir.com FAX PWB trouble copyir.com Check the destination of the FAX PWB copyir.com Replace the FAX PWB copyir.com
H2-00 Thermister open trouble (TH_UM_AD2) Thermister trouble copyir.com MFPC PWB trouble Connection trouble of the connector and the harness copyir.com Fusing unit not installed copyir.com Replace the thermister copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com
H2-02 Sub thermister open trouble (TH_US) Thermister trouble copyir.com MFPC PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Fusing unit not installed copyir.com Replace the thermister copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com
H2-03 Compensation thermister open trouble (TH_UM_AD1) Thermister trouble copyir.com MFPC PWB trouble Connection trouble of the connector and the harness copyir.com Fusing unit not installed copyir.com Replace the thermister copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com
H3-00 Fusing section high temperature trouble (TH_UM) The fusing temperature exceeds the specified level copyir.com Thermister trouble copyir.com MFPC PWB trouble Connection trouble of the connector and the harness copyir.com Power unit trouble copyir.com Use SIM5-2 to check the flashing operation of the heater lamp copyir.com Use SIM14 to cancel the trouble copyir.com Replace the thermister copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com Replace the power unit copyir.com
H3-02 Fusing section high temperature trouble (TH_US) The fusing temperature exceeds the specified level copyir.com Thermister trouble copyir.com MFPC PWB trouble Connection trouble of the connector and the harness copyir.com Power unit trouble copyir.com Use SIM5-2 to check the flashing operation of the heater lamp copyir.com Use SIM14 to cancel the trouble copyir.com Replace the thermister copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com Replace the power unit copyir.com
H4-00 Fusing section low temperature trouble (TH_UM_AD2) The fusing temperature does not reach the specified level within the specified time from turning ON the power relay copyir.com Thermister trouble copyir.com Heater lamp trouble copyir.com MFPC PWB trouble copyir.com Thermostat trouble copyir.com Connector, harness connection trouble copyir.com Power unit trouble copyir.com Interlock switch trouble copyir.com Replace the thermister copyir.com Replace the heater lamp copyir.com Replace the MFPC PWB copyir.com Replace the thermostat copyir.com Check connection of the connector and the harness copyir.com Replace the power unit copyir.com Replace the interlock switch copyir.com Use SIM5-2 to check the flashing operation of the heater lamp copyir.com Use SIM14 to cancel the trouble copyir.com
H5-01 5 times continuous POD1 not-reach jam A fusing jam is not canceled completely copyir.com (A jam paper remains copyir.com) POD1 sensor trouble copyir.com Fusing unit installation trouble copyir.com Connector, harness connection trouble copyir.com MFPC PWB trouble Replace the POD1 sensor copyir.com Check the installing position of the fusing unit copyir.com Replace the fusing unit copyir.com Check connection of the connector and the harness copyir.com Replace the MFPC PWB copyir.com Use SIM14 to cancel the trouble copyir.com
H7-10 Fusing low temperature recovery trouble (TH_UM_AD2) copyir.com The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature copyir.com Thermister trouble copyir.com Heater lamp trouble copyir.com MFPC PWB trouble Thermostat trouble copyir.com Connector, harness connection trouble copyir.com Power unit trouble copyir.com Interlock switch trouble copyir.com Replace the thermister copyir.com Replace the heater lamp copyir.com Replace the MFPC PWB copyir.com Replace the thermostat copyir.com Check connection of the connector and the harness copyir.com Replace the power unit copyir.com Replace the interlock switch copyir.com Use SIM5-2 to check the flashing operation of the heater lamp copyir.com
L1-00 Scanner feed trouble Scanner feed is not completed within the specified time copyir.com Scanner unit trouble copyir.com MFPC PWB trouble Harness and connector connection trouble copyir.com Scanner home position sensor trouble copyir.com Scanner motor trouble copyir.com Use SIM1-1 to check the scan operation copyir.com Replace the scanner unit copyir.com Replace the MFPC PWB copyir.com Check connection of the connectors and the harness copyir.com Replace the scanner home position sensor copyir.com Replace the scanner motor copyir.com
L3-00 Scanner return trouble Scanner return is not completed within the specified time copyir.com Scanner unit trouble copyir.com MFP PWB trouble Harness and connector connection trouble copyir.com Scanner home position sensor trouble copyir.com Scanner motor trouble copyir.com Use SIM1-1 to check the scan operation copyir.com Replace the scanner unit copyir.com Replace the MFP PWB copyir.com Check connection of the connectors and the harness copyir.com Replace the scanner home position sensor copyir.com Replace the scanner motor copyir.com
L4-02 Paper feed motor trouble
A lock signal is not detected within the specified time in ON operation of the paper feed motor after warming-up or canceling a jam copyir.com Paper feed motor trouble Paper feed motor harness and connector connection trouble MFPC PWB trouble Use SIM6-1 to check the operation of the paper feed motor copyir.com Replace the paper feed motor copyir.com Check connection of the paper feed motor harness and the connector copyir.com Replace theMFPC PWB copyir.com
L4-03 Fusing motor lock trouble The motor lock signal is detected during rotation of the fusing motor copyir.com Fusing motor trouble copyir.com MFPC PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Use Sim6-1 to check the operation of the fusing motor copyir.com Replace the fusing motor copyir.com Replace the MFPC PWB copyir.com Check connection of the connector and the harness copyir.com
L4-04 Developing motor trouble (BLACK) The motor lock signal is detected during rotation of the developing motor copyir.com Developing motor trouble copyir.com Harness and connector connection trouble copyir.com MFPC PWB trouble Developing unit trouble copyir.com Use SIM25-1 to check the operation of the developing motor copyir.com Replace the developing motor copyir.com Check connection of the connectors and the harness copyir.com Replace the MFPC PWB copyir.com Replace the developing motor copyir.com Replace the developing unit copyir.com
L4-06 Transfer unit lift trouble Transfer unit position sensor trouble copyir.com MFPC PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Transfer unit separation clutch operation trouble copyir.com Primary transfer belt unit is not installed copyir.com Use SIM6-3 to check the separating operation of the transfer unit copyir.com Install the primary transfer belt unit copyir.com Replace the transfer unit position sensor copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com Replace the transfer unit separation clutch copyir.com
L4-17 Drum motor lock trouble Drum motor trouble Connection trouble of the connector and the harness between MFPC PWB and the drum motor MFPC PWB trouble Check the operation of the drum motor with SIM 25-01 Check the connection of the connector and the harness between MFPC PWB and the drum motor Replace the drum motor Replace the MFPC PWB
L4-32 Power source cooling fan trouble The fan operation signal is not detected within the specified time in the power cooling fan operation copyir.com Power cooling fan trouble copyir.com MFPC PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Use SIM6-2 to check the rotating operation of the fan copyir.com Replace the power cooling fan copyir.com Replace the MFPC PWB copyir.com Check/replace the connector or the harness copyir.com
L4-34 LSU fan trouble The fan rotation signal is not detected in the specified time during operation of the LSU fan copyir.com Connection trouble of the connector and the harness copyir.com LSU fan trouble copyir.com Replace the MFPC PWB copyir.com Use Sim6-2 to check the operation of the fan copyir.com Check connection of the connector and the harness copyir.com Replace the LSU fan copyir.com Replace the MFPC PWB copyir.com
L4-35 Fusing cooling fan trouble The fan operation signal is not detected within the specified time in the fusing cooling fan operation copyir.com Fusing cooling fan trouble copyir.com MFPC PWB trouble Connection trouble of the connector and the harness copyir.com Use SIM6-2 to check the rotating operation of the fan copyir.com Replace the fusing cooling fan copyir.com Replace the MFPC PWB copyir.com Harness and connector connection trouble copyir.com
L4-40 Ozone fan motor 1 trouble Connection trouble of the connector and the harness between MPFPC PWB and the fan motor copyir.com MFPC PWB trouble FAN motor trouble The fan is not operated by other causes (the power is not supplied) copyir.com Check the fan motor operation with the SIM06-02 copyir.com Check the harness and connector connection between the MFPC PWB and the fan motor copyir.com Replace the fan motor Replace the MFPC PWB copyir.com
L6-10 Polygon motor trouble The motor does not reach the specified rpm in specified time after starting rotation of the polygon motor copyir.com Polygon motor trouble copyir.com LSUcnt PWB trouble copyir.com Connection trouble of the connector and the harness copyir.com Use SIM61-1 to check the operation of the polygon motor copyir.com Check connection of the connectors and the harness copyir.com Replace the polygon motor copyir.com Replace the LSU copyir.com
L8-02 Full wave signal error An abnormality in the full wave signal frequency is detected copyir.com (The frequency is detected as 80Hz or above, or 30Hz or less copyir.com) MFPC PWB trouble copyir.com Power unit trouble copyir.com Connection trouble of the connector and the harness copyir.com Power frequency, waveform abnormality copyir.com Replace the MFPC PWB copyir.com Replace the power unit copyir.com Check connection of the connectors and the harness copyir.com Check the power waveform copyir.com a jam copyir.com
U1-01 Battery trouble 1) Battery life 2) Battery circuit abnormality Check to confirm that the battery voltage is about 2 copyir.com0V or above copyir.com Use SIM13 to cancel the trouble copyir.com
U2-00 MFPC EEPROM read/write error MFPC PWB EEPROM trouble copyir.com EEPROM socket contact trouble copyir.com MFP PWB trouble copyir.com Strong external noises copyir.com Use SIM16 to cancel the error copyir.com Replace the MFP PWB EEPROM copyir.com Replace the MFP PWB copyir.com Check the power environment copyir.com
U2-05 Erroneous detection of account management data EEPROM is broken The device access error/connection error of EEPROM by the noise copyir.com Cancel the error by SIM16
U2-11 MFPC PWB EEPROM counter check sum error MFPC PWB EEPROM trouble copyir.com EEPROM socket contact trouble copyir.com MFPC PWB trouble copyir.com Strong external noises copyir.com Use SIM16 to cancel the error copyir.com Replace the MFPC PWB copyir.com
U5-40 SPF connection trouble Hardware trouble Check the operation of the SPF and the control circuit
U9-00 Communication trouble between the controller and OPU OPU connector connection trouble Harness trouble between OPU PWB and MCU PWB Break connector pin of OPU PWB Lift unit trouble copyir.com Connection trouble of the connector and the harness copyir.com PCU PWB trouble Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
U9-81 OPU communication trouble (parity) OPU connector connection trouble Harness trouble between OPU PWB and MCU PWB Break connector pin of OPU PWB Lift unit trouble copyir.com Connection trouble of the connector and the harness copyir.com PCU PWB trouble Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
U9-82 OPU communication trouble (overrun) Connection error between OPU PWB and MCU PWB / data corruption Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
U9-84 OPU communication trouble (flaming) Connection error between OPU PWB and MCU PWB / data corruption Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
U9-88 OPU communication trouble (timeout) Command size error from MCU to OPU Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
U9-99 OPU language error Command size error from MCU to OPU Check connector connection and harness of OPU PWB and MCU PWB Replace OPU PWB or MCU PWB Check ground point Power off/on
UC-02 IPD ASIC (CPT) error IPD ASIC (CPT) operation error MFPC PWB trouble copyir.com Replace the MFPC PWB copyir.com