01    The print server card is broken down or is not installed  copyir.com
Print server card connection trouble    The print server card is not installed on the controller  copyir.com  Print server card control PWB trouble
C1-00    MC trouble
Main charger output abnormality (Output open) Trouble signal is outputted from the high voltage transformer  copyir.com     The main charger is not installed properly  copyir.com  The main charger is not assembled properly  copyir.com  Disconnection of connector of high voltage transformer  copyir.com  High voltage harness disconnection or breakage  copyir.com
CE-00    Another communication error occurs  copyir.com     Improper connection of the network cable
CE-02    The specified mail server or FTP server is not found  copyir.com
The specified mail server or the FTP server is not found  copyir.com     Improper connection of the network cable Network setup trouble An error occurs in the SMTP server/ FTP server/ NTS  copyir.com
CE-03    The specified server suspends response during transmission of images  copyir.com
The specified server suspends response during transmission of images  copyir.com     Improper connection of the network cable An error occurs in the SMTP server/ FTP server/ NTS  copyir.com
CE-04    The account name or the password for the FTP server is invalid  copyir.com
The entered account name of the FTP server or the password for authentication is invalid  copyir.com     Improper connection of the network cable Improper registration of the account name or improper password registered in the FTP server as the destination
CE-05    The directory of the FTP server is invalid  copyir.com
The entered directory of the FTP server is invalid  copyir.com     Improper connection of the network cable Check for existence of the directory name in the FTP server registered as the destination  copyir.com
CE-06    The specified mail server (POP3) is not found  copyir.com
The specified mail server (POP3) is not found  copyir.com  POP3 server access error    Improper connection of the network cable Network setup trouble An error occurs in the POP3 server  copyir.com
CE-07    The entered account name of the POP3 server or the password for authentication is invalid  copyir.com
The entered account name of the POP3 server or the password for authentication is invalid  copyir.com  POP3 server authentication check error    Improper connection of the network cable Improper account name or password registered in the POP3 server
CE-08    The specified mail server (POP3) is not found  copyir.com
The specified mail server (POP3) is not found  copyir.com  POP3 server time out error    Improper connection of the network cable An error occurs in the POP3 server  copyir.com
E6-11    CSI shading trouble (White correction)
The CIS white reference plate scan level is abnormal when the lamp is on  copyir.com     Abnormal harness installation to CIS unit Dirt on the white reference plate  copyir.com  CIS lighting error CIS unit installation trouble CIS unit abnormality Scanner PWB abnormality
E6-14    CIS communication trouble
Communication trouble (clock sync) between scanner PWB and CIS-ASIC    Abnormal harness installation to CIS unit CIS unit abnormality Scanner PWB abnormality
E7-01    System data trouble
When in data storage/acquiring of the HDD system area, the HDD responds an error and does not respond for 30sec, it is judged as a trouble  copyir.com     The HDD is not properly installed to the ICU PWB  copyir.com  The HDD does not work for the ICU PWB  copyir.com  ICU PWB abnormality
E7-02    Laser trouble
BD signal from LSU is kept OFF, or ON  copyir.com     The connector of LSU or the harness in LSU is disconnected or broken  copyir.com  The polygon motor does not rotate normally  copyir.com  The laser home position sensor in LSU is shifted  copyir.com  The proper voltage is not supplied to the power line for laser  copyir.com  Laser emitting diode trouble PCU PWB trouble ICU PWB trouble
E7-03    HDD trouble
HDD connection failure If the HDD responds an error or does not respond for 30sec, it is judged as an error  copyir.com  (Other than the system area) Data abnormality in the file management area (when the cluster chain is broken)    HDD is not installed properly to the ICU PWB  copyir.com  HDD does not operate properly in the ICU PWB  copyir.com  ICU PWB trouble
E7-06    Decode error trouble
A decode error occurs during making of an image  copyir.com     Data error during input from PCI to PM  copyir.com  PM trouble Data error during image compression/ transfer  copyir.com  ICU PWB abnormality
E7-10    Shading trouble (Black correction)
CCD black scan level abnormality when the copy lamp is off  copyir.com     Abnormal installation of flat cable to CCD unit  copyir.com  CCD unit abnormality Scanner PWB abnormality
E7-11    Shading trouble (White correction all pixel adjustment)
CCD white reference plate scan level abnormality when the copy lamp is ON  copyir.com     Abnormal installation of flat cable to CCD unit  copyir.com  Dirt on mirror, lens, white reference plate Copy lamp lighting abnormality Abnormal installation of CCD unit CCD unit abnormality Scanner PWB abnormality
E7-14    CCD communication trouble
Communication trouble (clock sync) between scanner PWB and CCD-ASIC    Abnormal installation of harness to CCD unit CCD unit abnormality Scanner PWB abnormality
E7-17    SPF scanning position adjustment trouble (Detected only when executing an adjustment SIM  copyir.com )
The black Mylar which serves as the reference of the SPF scanning position is not detected  copyir.com     Black Mylar installing failure on the SPF side
E7-50    LSU connection trouble
An LSU which does not conform to the machine is installed  copyir.com     LSU connection trouble PCU PWB trouble LSU trouble
E7-60    Controller skating trouble
Occurrence of an error in controller skating check    Discrepancy in the combination of the controller PWB and the ROM
E7-80    Communication trouble (ICU detection) between ICU and scanner
Communication establishment error/ Fleming/Parity/Protocol error    Defective connection of slave unit PWB connector Defective harness between slave unit PWB and ICU PWB Slave unit PWB mother board connector pin breakage
E7-90    Communication trouble (ICU detection) between ICU and PCU
Communication establishment error/ Fleming/Parity/Protocol error    Defective connection of slave unit PWB connector Defective harness between slave unit PWB and ICU PWB Slave unit PWB mother board connector pin breakage
EE-EL    Auto developer adjustment trouble (Over-toner)
The toner concentration output is detected as 1  copyir.com 5V or below in the auto development adjustment  copyir.com     Toner concentration sensor trouble Charging voltage, developing voltage abnormality Insufficient toner concentration Developing unit trouble PCU PWB trouble
EU    Auto developer adjustment trouble (Under-toner)
The toner concentration output is detected as 3  copyir.com 5V or above in the auto development adjustment  copyir.com     Insufficient toner concentration Charging voltage, developing voltage abnormality Insufficient toner concentration Developing unit trouble PCU PWB trouble
F1-00    Finisher communication trouble
Communication cable test error after turning on the power or exiting from SIM  copyir.com  Communication error with the finisher    Improper connection or disconnection of connectors and harness between the machine and the finisher  copyir.com  Finisher control PWB trouble Control PWB (PCU) trouble Malfunction by noises
F1-00    Mail-bin stacker communication trouble
Communication cable test error after turning on the power or exiting from SIM  copyir.com  Communication error with the Mail-bin stacker  copyir.com     Improper connection or disconnection of connector and harness between the machine and the Mail-bin stacker  copyir.com  Mail-bin stacker control PWB trouble Control PWB (PCU) trouble Malfunction by noises
F1-02    Finisher transport motor abnormality
Transport motor drive trouble    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Motor RPM abnormality Overcurrent to the motor Finisher control PWB trouble
F1-02    Mail-bin stacker transport motor abnormality
Transport motor trouble    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Motor rpm abnormality Overcurrent to the motor Mail-bin stacker control PWB trouble
F1-03    Console finisher paddle motor trouble
Paddle motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-06    Console finisher slide motor trouble
Slide motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-08    Finisher staple shift motor trouble
Staple motor drive trouble    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Finisher control PWB trouble
F1-10    Finisher stapler motor trouble
Stapler motor operation abnormality    Motor lock Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-10    Console finisher stapler motor trouble
Stapler motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-11    Finisher bundle exit motor trouble
Bundle exit motor operation abnormality    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Console finisher control PWB trouble
F1-11    Console finisher bundle exit motor trouble
Bundle exit motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-12    Mail-bin stacker gate trouble
Gate operation abnormality    Gate lock Defective connection or disconnection between the PWB and the solenoid  copyir.com  Mail-bin stacker control PWB trouble
F1-15    Finisher lift motor trouble
Lift motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Finisher control PWB trouble
F1-15    Console finisher lift motor trouble
Lift motor operation abnormality    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Upper/lower limit sensor trouble Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-19    Finisher front alignment motor trouble
Front alignment motor operation abnormality    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Finisher control PWB trouble
F1-19    Console finisher front alignment motor trouble
Front alignment motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-20    Finisher rear alignment motor trouble
Rear alignment motor operation abnormality    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Finisher control PWB trouble
F1-20    Console finisher rear alignment motor trouble
Rear alignment motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-30    Console finisher communication trouble
Communication cable test error after turning on the power or exiting from SIM  copyir.com  Communication error with the console finisher    Improper connection or disconnection of connector and harness between the machine and the console finisher  copyir.com  Console finisher control PWB trouble Control PWB (PCU) trouble Malfunction by noises
F1-31    Console finisher fold sensor trouble
Sensor input value abnormality    Sensor breakage harness breakage Console finisher control PWB trouble
F1-32    Communication trouble between the console finisher and the punch unit  copyir.com     Improper connection or disconnection of connector and harness between the console finisher and the punch unit  copyir.com  Console finisher control PWB trouble Control PWB (PCU) trouble Malfunction by noise
F1-33    Console finisher punch side registration motor trouble
Punch side registration motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-34    Console finisher punch motor trouble
Punch motor operation abnormality    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-35    Console finisher punch side registration sensor trouble
Sensor input value abnormality    Sensor breakage Harness disconnection Console finisher control PWB trouble
F1-36    Console finisher punch timing sensor trouble
Sensor input value abnormality    Sensor breakage Harness disconnection Console finisher control PWB trouble
F1-37    Console finisher backup RAM trouble
Backup RAM contents are disturbed  copyir.com     Console finisher control PWB trouble Malfunction by noise
F1-38    Console finisher punch backup RAM trouble
Punch unit backup RAM contents are disturbed  copyir.com     Punch control PWB trouble Malfunction by noise
F1-39    Console finisher punch dust sensor trouble
Punch dust sensor detection trouble    When the punch dust sensor is not normally detected  copyir.com
F1-40    Console finisher punch power interruption trouble
When power interruption of the punch unit is detected    Though 24V is supplied to the punch unit, the punch unit detects power interruption  copyir.com
F1-80    Finisher power abnormality
The 24V power is not supplied to the finisher PWB  copyir.com     Improper connection or disconnection of connector and harness Finisher control PWB trouble Power unit trouble
F1-80    Mail-bin stacker power abnormality
The 24V power is not supplied to the Mail-bin stacker PWB  copyir.com     Improper connection or disconnection of connector and harness Mail-bin stacker control PWB trouble Power unit trouble
F1-81    Console finisher transport motor abnormality
Transport motor trouble    Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
F1-87    Finisher staple rotation motor trouble
Front staple rotation motor trouble    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Home position sensor abnormality Motor rpm abnormality Overcurrent to the motor Finisher control PWB trouble
F2-00    Toner control sensor open/sensor trouble
Toner control sensor output open    Connector harness trouble Connector disconnection Sensor trouble
F2-02    Toner supply abnormality
Toner control sensor output value becomes under-toner too earlier  copyir.com     Connector harness trouble Toner concentration sensor trouble Toner cartridge trouble
F2-04    Improper cartridge (life cycle error, etc  copyir.com )
An improper process cartridge is inserted  copyir.com     IC chip trouble Improper cartridge
F2-05    CRUM error
Communication with IC chip cannot be made  copyir.com     IC chip trouble IC chip contact failure Improper cartridge
F2-39    Process thermistor trouble
Output value abnormality of the temperature sensor of temperature/ humidity sensor    Temperature/humidity sensor abnormality Temperature/humidity sensor harness connection failure PCU PWB trouble
F2-58    Process humidity sensor breakdown
Process humidity sensor open or short    Temperature/humidity sensor harness connection failure Temperature/humidity sensor abnormality PCU PWB trouble
F3-12    Machine no  copyir.com  1 tray lift-up trouble
LUD does not turn ON in the specified time  copyir.com     LUD trouble No  copyir.com  1 tray lift-up trouble Check connection of harness between the PCVU PWB, lift-up unit, and paper feed unit  copyir.com
F3-22    Machine tray 2 lift-up trouble
MCLUD does not turn ON in the specified time  copyir.com     MCLUD trouble No  copyir.com  2 tray lift-up motor trouble Harness disconnection f the PCU PWB, the lift-up unit, and the paper feed unit  copyir.com
F6-00    Communication trouble (ICU detection) between ICU and FAX
Communication establishment error/ Fleming/Parity/Protocol error    Slave unit PWB connector disconnection Harness abnormality between slave unit PWB and ICU PWB  copyir.com  Slave unit PWB mother board connector pin breakage Slave unit ROM abnormality/No ROM/ Reverse insertion of ROM/ROM pin breakable
F6-01    FAX expansion flash memory abnormality (ICU detection)
Flash memory cannot be deleted  copyir.com     Flash memory cannot be deleted  copyir.com
F6-04    FAX modem operation abnormality
FAX PWB modem chip operation abnormality    SW101 in the FAX PWB tries to perform normal operation on the boot side  copyir.com  Modem chip operation abnormality in FAX PWB
F6-20    FAX write protect cancel
The write protect JP is released  copyir.com     The write protect JP is set to “write allow  copyir.com ” FAX interface PWB trouble FAX PWB trouble
F6-21    Combination abnormality of the TEL/ LIU PWB and the FAX soft switch
Combination abnormality of the TEL/ LIU PWB and the FAX PWB information (soft switch) Or the TEL/LIU PWB is not a new one for new MDMC PWB  copyir.com     The destination of the installed TEL/LIU PWB differs  copyir.com  The FAX PWB information (soft switch) differs  copyir.com  TEL/LIU PWB trouble
F6-97    FAX-BOX skating trouble The FAX-BOX PWB is not one for the AR-FX12  copyir.com  (FAX detection)
The FAX-BOX MODEM controller is not one for the AR-FX12  copyir.com     The FAX-BOX Modem controller PWB information (hard detection) is not for the AR-FX12  copyir.com  (The Modem controller PWB for the AR-FX5 or the AR-FX6 is used  copyir.com )
F6-98    Combination error of the FAX-BOX destination information and the machine destination information
Combination error of the FAX-BOX destination information and the machine destination information    Because of improper combination between the destination information stored in the EEPROM on the FAXBOX PWB and that of the machine (set with SIM 26-6)  copyir.com
F7-01    FAX board EEPROM read/write error
EEPROM access error (read/write)    EEPROM trouble FAX PWB EEPROM access circuit trouble
H2    Thermistor open Fusing unit not installed
Thermistor is open  copyir.com  (An input voltage of 2  copyir.com 92V or above is detected  copyir.com ) Fusing unit not installed    Thermistor trouble Control PWB trouble Fusing section connector disconnection AC power trouble Fusing unit not installed
H3    Fusing section high temperature trouble
The fusing temperature exceeds 242°C  copyir.com  (An input voltage of 0  copyir.com 27V or above is detected  copyir.com ) Fusing temperature control is started, and 242°C is detected three or more times continuously in sampling in the specified interval  copyir.com  (Every 300msec)    Thermistor trouble Control PWB trouble Fusing section connector disconnection AC power trouble
H4    Fusing section low temperature trouble
The set temperature is not reached within the specified time (3 min) after turning on the power relay, or the temperature does not reach 80°C within 80 sec  copyir.com  When the heater lamp is not turned off in the specified time (3 min) from starting warm-up, or the temperature does not reach 80°C within 80 sec  copyir.com  After completion of warm-up operation, a temperature 50°C lower than the temperature control level is detected 5 times continuously in sampling in the specified interval  copyir.com  (every 300msec)    Thermistor trouble Heater lamp trouble Control PWB trouble Thermostat trouble AC power trouble Interlock switch trouble
H5-01    5-time continuous POD1 not-reaching jam detection
5-time continuous POD1 not-reaching jam detection    A fusing section jam is not properly removed  copyir.com  (Jam paper remains  copyir.com ) POD1 sensor trouble, or harness disconnection Improper installation of fusing unit
L1-00    Scanner feed trouble
Scanner feed is not completed within the specified time  copyir.com     Scanner unit abnormality Scanner wire disconnection
L3-00    Scanner return trouble
Scanner return is not completed within the specified time  copyir.com     Scanner unit abnormality Scanner wire disconnection
L4-01    Main motor lock detection
The motor lock signal is detected for 1  copyir.com 5sec during rotation of the main motor  copyir.com     main motor trouble Check connection of harness between the PCU PWB and the main motor  copyir.com  Control circuit trouble
L4-02    Drum motor lock detection
The motor lock signal is detected for 1  copyir.com 5sec during rotation of the drum motor  copyir.com     Drum motor trouble Improper connection of harness between the PCU PWB and the drum motor  copyir.com  Control circuit trouble
L4-30    Controller fan motor lock detection
The motor lock signal is detected during rotation of the controller fan motor  copyir.com  The motor lock signal is detected during rotation of the HDD fan motor  copyir.com     Fan motor trouble Improper connection of the harness between the controller PWB and the fan motor  copyir.com  Control circuit trouble
L6-10    Polygon motor lock detection
It is judged that the polygon motor lock signal is not outputted  copyir.com  Lock signal is checked in the interval of 10sec after starting the polygon motor, and it is judged that the polygon motor does not rotate normally  copyir.com     The LSU connector or harness in the LSU is disconnected or broken  copyir.com  Polygon motor trouble
L8-01    No fullwave signal
Full wave signal is not detected  copyir.com     The PCU PWB connector or the power unit harness is disconnected or broken  copyir.com  PCU PWB trouble 12V power source trouble
L8-02    Full wave signal width abnormality
It is judged as full wave signal frequency abnormality  copyir.com  (When the detection cycle is judged as 69Hz or above or 42  copyir.com 5Hz or below)    The connector or harness of the PCU PWB and the power PWB is disconnected  copyir.com  PCU PWB trouble Power unit trouble
PF-00    RIC copy inhibit signal is received  copyir.com
Copy inhibit command from RIM (host) is received  copyir.com     Judged by the host  copyir.com
U1-01    FAX battery abnormality
FAX backup SRAM battery voltage fall    Battery life Battery circuit abnormality
U1-02    RTC read abnormality (common with FAX, on ICU PWB)
The value read from RTC on ICU PWB is [EE]h (abnormal)  copyir.com     RTC circuit abnormality Battery voltage fall Battery circuit abnormality
U2-00    EEPROM read/write error (ICU)
EEPROM write error    EEPROM trouble EEPROM is not initialized  copyir.com  ICU PWB EEPROM access circuit trouble
U2-11    Counter check sum error (ICU)
Counter data area check sum error    EEPROM trouble Control circuit trouble by noise ICU PWB EEPROM access circuit trouble
U2-12    Adjustment value check sum error (ICU)
Adjustment data area check sum error    EEPROM trouble Control circuit trouble by noise ICU PWB EEPROM access circuit trouble
U2-22    SRAM memory check sum error (ICU)
MFPC section SRAM memory check sum error    SRAM trouble Control circuit runaway due to noises ICU PWB SRAM access circuit trouble
U2-23    SRAM memory individual data check sum error (ICU)
Check sum error for every data in the SRAM memory of the MFPC section (Communication management table, sender registration data, etc  copyir.com )    SRAM trouble Control circuit runaway due to noises ICU PWB SRAM access circuit trouble
U2-50    HD section individual data check sum error (ICU)
Check sum error for every individual data in HD of the MFPC section (Onetouch, Group, Program, etc  copyir.com )    HDD write/read error Control circuit runaway due to noises ICU PWB HD access circuit trouble
U2-80    EEPROM read/write error (Scanner)
Scanner EEPROM write error    EEPROM abnormality Scanner PWB EEPROM access circuit abnormality
U2-81    Memory check sum error (Scanner)
Scanner memory check sum error    EEPROM trouble EEPROM which is not initialized is installed  copyir.com  Control circuit freeze by noises Scanner PWB EEPROM access circuit trouble
U2-90    EEPROM read/write error (PCU)
PCU EEPROM write error    EEPROM trouble PCU PWB EEPROM access circuit trouble
U2-91    Memory check sum error (PCU)
PCU memory check sum error    EEPROM trouble EEPROM which is not initialized is installed  copyir.com  EEPROM is not initialized  copyir.com  PCU PWB EEPROM access circuit trouble Hang of control circuit due to noises
U6-00    Desk/LCC communication trouble
Desk/LCC communication error Communication cable test error after turning on the power or exiting SIM  copyir.com     Improper connection or disconnection of connector and harness Desk control PWB trouble Control PWB (PCU) trouble Noise or interference
U6-01    Desk/LCC No  copyir.com  1 tray lift-up trouble    Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor  copyir.com  Desk control PWB trouble Lift-up motor trouble
U6-02    Desk No  copyir.com  2 tray/LCC1 lift-up trouble    Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor  copyir.com  Desk control PWB trouble Lift-up motor trouble
U6-03    Desk No  copyir.com  3 tray/LCC2 lift-up trouble    Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor  copyir.com  Desk control PWB trouble Lift-up motor trouble
U6-10    Desk/LCC transport motor trouble
Desk/LCC transport motor operation trouble    Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor  copyir.com  Motor rpm abnormality Overcurrent to the motor Desk control PWB trouble
U7-00    RIC communication trouble
RIC communication trouble Communication cable test error after turning on the power or exiting SIM  copyir.com     Disconnection of connector and harness RTC control PWB trouble Control PWB (ICU) trouble Noise or interference

پست های مرتبط